GovChime
AWARDDELIVERY ORDERSmall business

Delivery order GSP0610GZ5018WESTON EID INC

Overview

Award facts

Net obligations
$93.98K
$93,980of $93.98K potential value
Period of performance
Dec 21, 2009 to Dec 18, 2011
Ended
Modifications
1
Latest action Dec 21, 2009
Contract type
Delivery order
PIID GSP0610GZ5018

Description of requirement

RECOVERY. TAS::47 4543::TAS ROBERT A. YOUNG FEDERAL BUILDING, 1222 SPRUCE, ST. LOUIS, MO 63103 - RAY ARRA BLAST STUDY - IMO00090 PROVIDE BLAST MITIGATION ANALYSIS FOR THE RAY BUILDING IN ACCORDANCE WITH ATTACHED SCOPES OF WORK FOR THE BLAST & PROGRESSIVE COLLAPSE MITIGATION ANALYSIS. ALTHOUGH THE ATTACHED SCOPE OF WORK REFERENCES BOTH BLAST AND PROGRESSIVE COLLAPSE MITIGATION, ONLY A BLAST STUDY IS BEING REQUIRED AT THIS TIME. THE RAY BUILDING IS LOCATED IMMEDIATELY ADJACENT TO TWO STREETS WITH LIMITED SETBACK, AND IS ALSO CLOSE TO AN ELEVATED HIGHWAY AND RAILROAD TRACKS. A CHILD CARE CENTER IS LOCATED ON THE FIRST FLOOR, WITH AN ELEVATED OUTDOOR PLAYDECK. THE MAIN TEN STORY PORTION OF THE BUILDING IS FULLY OCCUPIED, AND THE WINDOWS IN THE OCCUPIED PORTION OF THE BUILDING CURRENTLY HAVE A DAYLIGHT APPLICATION OF BLAST FILM WITH A STRUCTURAL SILICONE BEAD. THE WINDOWS IN THE UNOCCUPIED TOWER PORTION DO NOT HAVE A BLAST FILM TREATMENT. ALL OF THE EXISTING WINDOWS ARE SINGLE GLAZED WITH ALUMINUM FRAMES. AN OPTION IS CURRENTLY BEING DEVELOPED FOR REPLACEMENT OF ALL WINDOWS IN THE BUILDING WITH ENERGY EFFICIENT WINDOWS WITH A MORE HISTORICALLY APPROPRIATE APPEARANCE. THE BLAST MITIGATION ANALYSIS / WINDOW VUNERABILITY ASSESSMENT (AKA BLAST STUDY) SHALL INCLUDE: DETERMINATION OF THE LEVEL OF PROTECTION PROVIDED BY THE CURRENT BLAST FILM EXISTING WINDOW RETROFITS: UP TO THREE RECOMMENDED TREATMENTS AND ESTIMATED COSTS TO REACH A MINIMUM LEVEL 3 OF PROTECTION IN ALL OCCUPIED AREAS, WITH A MINIMUM LEVEL 2 PROTECTION FOR THE CHILD CARE CENTER. REPLACEMENT WINDOW UPGRADES: TWO TO THREE RECOMMENDED TREATMENTS AND ESTIMATED ASSOCIATED COSTS TO BE INCORPORATED INTO ANY WINDOW REPLACEMENTS TO ACHIEVE A MINIMUM LEVEL 3 OF PROTECTION IN ALL OCCUPIED AREAS, WITH A MINIMUM LEVEL 2 PROTECTION FOR THE CHILD CARE CENTER. SYSTEMS TO BE CONSIDERED SHALL INCLUDE BUT NOT BE LIMITED TO INTERNAL CATCH SYSTEMS, AND LAMINATED GLASS, INSULATING GLASS UNITS, NEW FRAMES, A SECONDARY INTERIOR BLAST RESISTANT WINDOW AND/OR BLAST CURTAINS/SHIELDS. STUDY SHALL CONSIDER THE RELATIVE IMPACT OF VARIOUS BLAST TREATMENTS ON TENANT DISRUPTION AND CONSTRUCTABILITY, LENGTH OF CONSTRUCTION, INTERIOR AND EXTERIOR APPEARANCE OF THE WINDOWS, AND IMPACT ON QUALITY OF VIEWS AND DAYLIGHTING. THE AE PERFORMING THE BLAST STUDY IS REQUIRED TO COORDINATE FINDINGS WITH THE AE DESIGNING THE REPLACEMENT WINDOWS, TEAM FOUR IN ASSOCIATION WITH WISS JANEY ELSTNER.

Dates and value

Award date
Signed on Dec 18, 2009
Potential end of performance
Dec 17, 2011
Current value
$93,980Base and exercised options
Potential value (if all options are exercised)
$93,980
Parent contract vehicle
GS06P04GYD0002 (IDC, multiple award) — 15 orders recorded under it

Obligations by fiscal year of action

  • FY2010: $93,980

Total across 1 fiscal year: $93,980

Source: Federal Procurement Data System contract actions as published by SAM.gov and USAspending.gov; latest action recorded Dec 21, 2009. View on USAspending · Recipient on SAM.gov

Recipient

LocationLAKE SAINT LOUIS, MO
UEIRYCNE36ZCBR7
Business sizeSmall businessSize at award, per the contracting officer
Parent companyWESTON EID INC

Agency and place

Awarding and funding

Awarded by
  1. General Services Administration
  2. Public Buildings Service
  3. GSA/PUBLIC BUILDINGS SERVICE

Place of performance

Place of performance
Saint Louis, Saint Louis City, Missouri 63103-1024
Congressional district (place of performance)
MO-01As reported at the time of the action

Classification and competition

Classification

Product or service (PSC)
C215A/E PROD ENG SVCS (INCL DESIGN-CONT (service)

Competition

Extent competed
Full and open competitionA
Solicitation procedures
Subject to multiple award fair opportunityMAFO
Set-aside
Small business set aside - totalSBA
Contract pricing
Firm fixed priceJ
Offers received
1

Contract details

Cost Accounting Standards clause
Not applicable exempt from CASX
Service Contract Act labor standards
No
Commercial procedures
Commercial item procedures not usedD
Government-furnished property
Transaction does not use GFE/GFPN
Bundled requirement
Not a bundled requirementD
Consolidated requirement
No
Undefinitized action (terms not final)
No
Multi-year contract
No
Performance-based service acquisition
No - service where PBA is not used.N

Transaction history

Modification history

Base award
Dec 18, 2009Base obligation at award: $93,980
Latest action
Dec 21, 2009 — Other administrative actionModification PA01; administrative: no change in scope or value
Actions by type
  • Base award1
  • Other administrative action1
2 actions recorded, Dec 18, 2009 to Dec 21, 2009; each action counted once.

All contract data

All contract data

Every other field reported for this award, as of its latest reported action

Competition

Local area set-aside
No
Simplified procedures for commercial items
No
A-76 (FAIR Act) action
No

Pricing and financing

Paid by purchase card
No

Socio-economic and policy

EPA-designated product
Not requiredE
Clinger-Cohen Act planning (IT)
No

Structure

Award or IDV
Award
Award type
Delivery orderC
Parent vehicle type
IDCB
Parent vehicle: multiple or single award
Multiple awardM
Parent vehicle agency
Public Buildings Service4740
Awarding agency code
4700
Awarding sub-tier code
4740
Contracting office code
GZ000
Transactions recorded under this award key
2