Po HHSF223201111677PSCILOG INC.
Overview
Award facts
- Period of performance
- Sep 7, 2011 to Nov 30, 2011
- Ended
- Modifications
- 0
- Latest action Aug 18, 2011
- Contract type
- Po
- PIID HHSF223201111677P
Description of requirement
THIS IS A PURCHASE OF A MICRO SCALE TANGENTIAL FLOW FILTRATION (TFF) SYSTEM. ITEM # 1: TFF SYSTEM WITH CONDUCTIVITY CONTROL AND DOCUMENTATION. SYSTEM CONTAINS PERISTALTIC HEAD (MAX 600 RPM MOTOR FLOW RANGE) MOUNTED WITH TWO PUMP HEADS (USING MASTERFLEX THIN-WALLED TUBING SIZES 13, 14, 16, 17,&25).ITEM # 2: PRE-CALIBRATED DISPOSABLE PRESSURE IN-LINE SENSORS, MAX 60 PSI MAXIMUM FLOW OF UP TO 2 0 LITERS/MIN WITH LEUR-LOCK FITTINGS. TO FIT A RANGE OF CHOICE OF TUBING.ITEM # 3: PRE-CALIBRATED DISPOSABLE CONDUCTIVITY TEMPERATURE IN-LINE SENSORS PACK OF 5 EACH SENSOR HAS 4-ELECTRODE DESIGN GOLD CELL VOLUME 80 UL LUER-LOCK CONNECTOR MAX 60 PSI MAXIMUM FLOW OF UP TO 2 0 LITERS/MIN.GENERAL REQUIREMENTS:THE TANGENTIAL FLOW FILTRATION (TFF) SYSTEM MUST INCLUDE A STIRRER, A BALANCE, AND A BACKFLOW MONITOR ALL TO WORK IN AN INTEGRATED MANNER WITH THE PUMP SYSTEM IN A COLD OPERATING CONDITION IN ORDER TO BE ABLE TO CONTROL THE TFF PROCESS AND TO STOP PRECISELY WHEN THE VOLUME OF THE FILTRATION IS REDUCED TO SPECIFIED LEVEL. THE PRESSURE AND CONDUCTIVITY SENSORS MUST BE PRE-CALIBRATED TO ALLOW THE SYSTEM TO BE OPERATIONAL FOR USE OUT OF THE BOX WITHOUT REQUIRING CALIBRATIONS.SPECIFICATIONS&TECHNICAL REQUIREMENTS FOR THE MICROBIOREACTOR SYSTEM*THE TFF SYSTEM SHOULD BE OPERABLE IN COLD ROOM CONDITIONS.*THE TFF SHOULD BE VERSATILE TO HANDLE FERMENTATION BROTHS OF 100 ML TO SEVERAL L OF VOLUME, EVEN IF AN ADDITIONAL PUMP HEAD IS REQUIRED TO BE USED.*THE TFF SYSTEM SHOULD HAVE A VERY LOW HOLD UP VOLUME, PREFERABLY LESS THAN A FEW MILLILITERS.*THE TFF SYSTEM SHOULD ACCEPT FILTRATION CARTRIDGES TO A WIDE RANGE OF SIEVE SIZE FROM 5 KD TO 100 KD AND THE RESIN OF THE FILTRATION CARTRIDGES SHOULD BE VERY LOW PROTEIN BINDING TYPE.*THE TFF SYSTEM SHOULD PREFERABLY BE OF OPEN ARCHITECTURE TO ACCEPT MEMBRANES FROM ANY MANUFACTURER FOR TANGENTIAL FLOW FILTRATION. *THE STANDARD SYSTEM SHOULD INCLUDE A STIRRER, A BALANCE AND, IF REQUIRED, A BACKFLOW MONITOR ALL TO WORK IN AN INTEGRATED MANNER WITH THE PUMP SYSTEM IN A COLD OPERATING CONDITION IN ORDER TO BE ABLE TO CONTROL THE TFF PROCESS AND TO STOP PRECISELY WHEN THE VOLUME OF THE FILTRATION IS REDUCED TO SPECIFIED LEVEL. THE BACKFLOW MONITOR IS NEEDED TO CONTROL THE SYSTEM BASED ON TRANSMEMBRANE PRESSURE. *THE PRESSURE SENSORS (RANGE OF AT LEAST 0 TO 50 PSI) AND CONDUCTIVITY SENSORS (RANGE OF AT LEAST 1 MICRO S/CM TO 150MS/CM) SHOULD ALLOW A RANGE OF VALUES TO CONTROL FLOW PARAMETERS BASED ON THE LEVEL OF PRESSURE AND CONDUCTIVITY VALUES DECIDED BY THE USER. *THE CONDUCTIVITY SENSOR SHOULD COMMUNICATE WITH THE CONTROL UNIT EITHER VIA A CONDUCTIVITY MONITOR OR DIRECTLY TO BE ABLE TO CONTROL THE FLOW AND TO STOP PRECISELY WHEN SET CONDUCTIVITY IS REACHED TO HELP ACHIEVE BEST BUFFER EXCHANGES.*THE TFF SYSTEM SHOULD EMPLOY PRE-CALIBRATED PRESSURE AND CONDUCTIVITY SENSORS SO THAT THE SYSTEM IS READY TO USE OUT OF BOX NOT REQUIRING CALIBRATIONS.*THE TFF SHOULD BE OPERABLE IN A SEMI-AUTOMATED WAY.*ABILITY TO DELIVER THE EQUIPMENT IN A REASONABLE TIMEFRAME (WITHIN 60 DAYS OF CONTRACT AWARD).
Dates and value
- Award date
- Signed on Aug 18, 2011
- Potential end of performance
- Nov 29, 2011
Source: Federal Procurement Data System contract actions as published by SAM.gov and USAspending.gov; latest action recorded Aug 18, 2011. View on USAspending · Recipient on SAM.gov
Recipient
Business types and certifications
As represented in SAM.gov at the time of the action.
Subcontracting network
The prime, the subcontractors on this award, and their own subcontractors.
Agency and place
Awarding and funding
- Awarded by
- Department of Health and Human Services
- Food And Drug Administration
- DEPT OF HHS/FOOD AND DRUG ADMINISTRATION
- Funded by
- Department of Health and Human Services
- Food And Drug Administration
- DEPT OF HHS/FOOD AND DRUG ADMINISTRATION
Place of performance
- Place of performance
- Middleton, Dane County, Wisconsin 53562-2562
- Congressional district (place of performance)
- WI-02As reported at the time of the action
Classification and competition
Classification
- Product or service (PSC)
- 6640LABORATORY EQUIPMENT AND SUPPLIES (product)
Competition
- Extent competed
- Competed under SAPF
- Solicitation procedures
- Simplified acquisitionSP1
- Set-aside
- No set-aside used
- Contract pricing
- Firm fixed priceJ
- Offers received
- 3
Contract details
- Subcontracting plan
- Plan not requiredB
- Government-furnished property
- Transaction does not use GFE/GFPN
- Bundled requirement
- Not a bundled requirementD
- Consolidated requirement
- No
- Undefinitized action (terms not final)
- No
Linked notices
Notice | Notice ID | Type | Link | Posted |
|---|---|---|---|---|
Transaction history
Modification history
- Base award
- Aug 18, 2011Base obligation at award: $15,994
- Latest action
- Aug 18, 2011 — Base awardModification 0; obligation change +$15,994
- Actions by type
- Base award1
Similar awards
PIID | Match | Awardee |
|---|---|---|
All contract data
All contract data
Every other field reported for this award, as of its latest reported action
Competition
- Evaluation preference
- No preference used
- Simplified procedures for commercial items
- No
Pricing and financing
- Paid by purchase card
- No
- Latest action: change in base and exercised options
- $15,994
- Latest action: change in base and all options
- $15,994
Socio-economic and policy
- Recovered materials and sustainability
- No clauses included and no sustainability incluC
- EPA-designated product
- Not requiredE
Place and origin
- Domestic or foreign entity
- U.S. owned businessA
- Place of manufacture
- Mfg in U.S.D
Structure
- Award or IDV
- Award
- Award type
- PoB
- Awarding agency code
- 7500
- Awarding sub-tier code
- 7524
- Contracting office code
- 00223
- Transactions recorded under this award key
- 1
Funding
- Funding agency code
- 7500
- Funding sub-tier code
- 7524
- Funding office code
- 00223