Description

01/09/2024 - AMENDMENT 0001 - The purpose of this amendment is to change the site visit date from January 12th, 2024 at 1300 (MT) to January 19th at 1300 (MT) / 1400 (CT) due to concerns with weather conditions and COVID community levels. There are no other changes. The due date for offers is not extended. PROJECT NAME: PUMP HOUSE STABILIZATION DESCRIPTION OF WORK: WORK FOR THIS PROJECT CONSISTS OF STABILIZE THE BESSEY NURSERY PUMP HOUSE USING PUSH PIERS OR EQUIVALENT, TO PREVENT THE BUILDING FROM MOVING. THERE ARE 3 EXISTING WATERLINES THAT RUN OUT THE SOUTH AND EAST SIDE OF THE BUILDING ALONG WITH ELECTRICAL LINES. LOCATION: THIS PROJECT IS LOCATED ON THE BESSEY NURSERY COMPLEX ON THE NEBRASKA NATIONAL FORESTS AND GRASSLANDS LOCATED TWO (2) MILES WEST OF HALSEY, NEBRASKA. (THOMAS COUNTY, NE) PRE-PROPOSAL SITE VISIT SCHEDULED? YES, SEE SECTION L. SEND PROPOSALS TO WESTLEY.BISSON@USDA.GOV. DO NOT MAIL PROPOSALS. *REMEMBER TO INCLUDE THE COMPLETED J.3 EXPERIENCE QUESTIONNAIRE WITH YOUR PROPOSAL

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

No documents available.

Lifecycle

Solicitation:1240LT24Q0020
  1. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. 3×
    SolicitationCurrentJan 5, 2024

    Pump House Stabilization

    Notice 754c569136ba49e2844feaf5b7891a2a on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Login at https://piee.eb.mil and search for 'N4008526R0235' to obtain more details.*
52%
Solicitation09/03/2026
47%
AwardedOpen
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes only solicitation; quotes are being requested and a separate written solicitation will not be issued. The U.S. Fish & Wildlife Service, San Luis National Wildlife Refuge, Region 8, needs contractor rehabilitation of its fire protection and domestic water systems to restore life-safety compliance, operational reliability, and compliance with NFPA, California Building/Plumbing/Electrical Codes, AWWA, and ASSE standards. The construction magnitude is estimated to be between $200,000.00 to $225,000.00. The office is located - San Luis National Wildlife Refuge Visitor Center, located at 8975 Wolfsen Road, Los Banos, California 93635, approximately 10 miles west of the City of Los Banos, California. The anticipated performance period shall be completed within 180 days of Notice to Proceed (NTP) being issued. Wage Rates: General Wage Rate Decision Number: CA20260005 (01/02/2026) State: California County: Del Norte, Humboldt, Lake and Mendocino Counties in California This Request for Proposal (RFP) is a TOTAL SMALL BUSINESS SET ASIDE and is conducted under the procedures of FAR Parts 12 and 13, incorporating provisions and clauses in effect through Federal Acquisition Circular 2024-03. The NAICS code is 238220 and the small business size standard is $19.0m. Instructions to offeror: All responsible small business sources shall review all documentation and submit a proposal, which shall be considered by the agency. The contractor MUST show within the bid relevant experience by demonstrating the ability to successfully complete as follows; all state and local law; provides appropriate licenses and certified within the state of California for handling of Water system repairs; Sprinkler System with replacement/installation, replace restroom components and disposal. Offerors shall submit Bids electronically via email in accordance with the instructions below. Failure to submit all required documents may result in the proposal being determined non-responsive. Furthermore, read the entity¿s solicitation packet with statement of work (SOW) and attachments for additional details to create bid with technical approach to the standard Award that will be made as a firm-fixed-price contract. The basis of contract will be on technical approach and Price, as acceptability for this requirement below. Award of the contract will be made to a responsible source pursuant to FAR subpart 9.1. Please submit your proposal with solicitation document (showing unit and total price) on company letterhead; Pricing Form; SAM.gov UEI code; point of contact phone number and e- mail address. Refer to FAR provision 52.212-1 Instructions to Offerors ¿ Commercial Items for additional submission guidance and include a copy of FAR provision 52.212-3 Offeror Representations and Certifications -- Commercial Items with applicable sections completed. Bonds: A bid bond is required. Contractors are reminded that any amount awarded over $35,000 requires submission of a Payment Bond. Any amount over $150,000.00 requires both payment and performance bonds. Bonds are due no later than 10 calendar days after award. Due to the project magnitude, both payment and performance bonds will be required. Format for Proposals: 1.Proposals shall be 8 ½¿x 11¿ 2.A page is defined as one face of a sheet of paper containing information 3.Typing shall not be less than 12 pitches (Times New Roman/Ariel/Etc.), 1-inch border, no artistic script fonts for readability 4.Elaborate formats, bindings or color presentations are not desired or required Any and all questions shall be submitted via email only; no verbal questions will be accepted. Please be sure to include the solicitation number in your proposal and in the subject line of any email submitted. E-Mail Submission for Questions & Proposals: terrence_anderson@fws.gov Site Visit: 9:00 AM PST - Tuesday, November 10, 2026 Question Deadline Date: 9:00 AM PST Monday, November 16, 2026 Proposal/Bid Due: 1:00 pm PST Monday, November 30, 2026 Solicitation Package: ¿SF1449 - Solicitation ¿Pricing Form ¿Clauses & Provisions (Terms and Conditions) Wage Rate Determination ¿Statement of Work (SOW) ¿Four (4) Attachments In order to have a quote considered for award, respondent must be registered at the System for Award Management (SAM) website (https://www.sam.gov ) as an active vendor by the time an award decision is necessary.
47%
Combined Synopsis11/30/2026
Construct and install two maintenance pads to house all condensing units and provide single line as built drawings, install a two sided screen block at the front of the building matching the existing CMU block color and style, use solid and vented CMU blocks to ensure sufficient airflow around all condensing units, and build screen block walls two rows higher than the condensing units; the contractor shall supply a weatherproof 120V maintenance receptacle for each pad, core drill the existing wall of Building 119, install a 3 inch PVC pipe sealed with acoustical seal to maintain ICD 705 compliance per Tech Spec 1.5.1, install insulation on all line sets entering Building 119, run all electrical from Room 119s electrical mechanical room using panel EDH 1 3 rated at 480/277V and 800 amps, tie all new HVAC systems to the existing generator for backup power, surface mount electrical conduits in Room 119 and the exterior HVAC yard, run conduits underground to each maintenance pad, and supply a weatherproof disconnect for each condensing unit; the contractor shall install new cassette type HVAC systems in Rooms 112, 113, 114, and 132 using the existing suspended ceiling grid with added support, provide a 1 ton HVAC system with a separate controller for Room 112, provide 2 ton HVAC systems with separate controllers for Rooms 113 and 114, and provide a 4 ton HVAC system with a separate controller for Room 132; all design and construction shall comply with the current International Building Code, UFC standards, all applicable public laws, executive orders, CFR requirements, DOD instructions and directives, Nellis ID2 standards, and Clark County, Nevada, and federal codes and laws, and any discrepancies between codes or standards and contract documents shall be immediately reported to the Contracting Officer, with the more stringent requirement applying unless otherwise directed. 26 WPS request this HVAC installation and testing be accomplish within, 160 days, period of performance. Proposals will be evaluated using lowest price, technically acceptable. A site visit will take place on 8/4/2026 at 0830 AM PDT, meeting in front of building 119 main entrance. Please ensure your base pass request has been submitted to me by 2PM PDT on 7/24/2026 if you do not have base access to Nellis AFB to ensure you have access by the date of the site visit. Proposals are due by 8/18/2026 at 2:00 PDT. Answers will be provided via a solicitation amendment.
47%
Solicitation08/20/2026
*****Amend 0003 - The purpose of Amend 0003 is to revise the requirement removing temporary cooling and to extend the quote due date to 7 July 2026 at 10:00 AM EDT.***** *****Amend 0002 - The purpose of Amend 0002 is to include Attach 8 - RFIs with Answers and Attach 9 - Attachment to RFI Answers. The quote due date is extended to 24 June 2026 at 10:00 am EDT. ***** *****Amend 0001 - The purpose of Amend 0001 is to incorporate photos from the Site Visit as Attach 7 - Site Visit Photos. ***** The 911th Airlift Wing, Air Reserve Station (ARS) has a project to replace the chiller in Building 418 in Coraopolis, PA. Solicitation FA671226Q0010 is issued as a Request for Quote (RFQ). ***This is the re-release of FA671226Q0003.*** The solicitation document, with the incorporated clauses and provisions, will be issued in accordance with the Federal Acquisition Regulation (FAR) Parts 12 and 36 and will be incorporated in the awarded firm-fixed price contract. Interested vendors should reference the solicitation documents for all terms and conditions. All interested and eligible parties are responsible for monitoring this website to ensure they have the most current information (i.e. Amendments) for the solicitation. No paper solicitation will be available. Procurement is solicitation as a one hundred percent (100%) Small Business set-aside. The solicitation will result in a Firm-Fixed Price (FFP) contract. The North American Industry Classification System (NAICS) code is 238220 with a small business size standard of $19 Million. The magnitude of construction for this procurement is estimated to be between $250,000 and $500,000. Site Visit: An organized site visit will be held at the project location. See solicitation for details. In order to attend the site visit, you are required to pre-register. Attendance at the site visit will be limited to no more than two (2) representatives per company. The site visit will be held for the purpose of providing contractors with the opportunity to familiarize themselves with the site which may be helpful in the preparation of offers. Attendance at the site visit is not mandatory for offer submission; however, failure to visit the site will not relieve or mitigate the successful contractors responsibility and obligation to fully comply with the terms, conditions, and specifications contained and/or referenced in this document. Telephone requests for information will not be accepted or returned. In order to submit an offer on this project, your company must be registered in the System for Award Management (SAM) and maintain an active registration. Please see the attached solicitation and supporting documents.
47%
Combined Synopsis07/07/2026

Additional Details

Solicitation Number

1240LT24Q0020

Archive Date

Feb 10, 2024

Office Address

Ogden, UT, 844012310