GovChime
Notice ID: 9fa6862e760c43959e227ae6a99fb77aSpecial Notice

12444122Q0129 Myers Grinder Pumps and Rail Packages

Archived. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM UTC−04:00
Posted
September 14, 2022
Notice type
Special Notice
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
333914: Measuring, Dispensing, and Other Pumping Equipment Manufacturing
Agency
Department of AgricultureFOREST SERVICE

Notice details

Office
USDA FOREST SERVICE
Place of performance
Bedford, IN, 47421
Last updated
Dec 4, 2025

Identifiers

Solicitation number
12444122Q0129
Notice ID
9fa6862e760c43959e227ae6a99fb77a

Description

NAICS Code: 333914 Solicitation: 12444122Q0129 The U.S. Forest Service, under the authority of the FAR Subpart 13.5 authority of 41 U.S.C. 1901; (modified FAR 6.302-1), intends to issue a firm fixed price, sole source purchase order to STRAEFFER PUMP & SUPPLY for Lift Station Pumps and Rail System Supplies as listed. The Hoosier National Forest is requesting to order replacement sewage pumps and rail systems for the lift stations at Hardin Ridge Recreation Area. The existing pumps are mounted on a now-obsolete rail system that makes it difficult to pull the pumps for preventive maintenance and cleaning. As a result, some of the pumps have failed. The Forest has two spare pumps in storage, which will be used to replace the failed ones. This supply order will replenish our stock of spare pumps and allow us to furnish materials to retrofit two duplex lift stations with newer rails. The items requested are: Five (5) Myers WG20-21-20 Grinder Pumps Four (4) Myers SRA-125-CV Rail Packages Four (4) Myers TRS-100 Top Rail Support Plates Four (4) Myers IGB-100 Intermediate Guide Brackets Only Myers brand pumps and rail systems will meet the needs of the Forest. All lift stations in the system use Myers systems. Using components from a different manufacturer would increase the complexity of maintenance and require us to store spare parts that are incompatible with the rest of the system. The Myers brand is widely used within Region 9 and there are multiple contractors local to Southern Indiana with experience installing and repairing Myers systems. NO SOLICITATION OR REQUEST FOR QUOTE IS AVAILABLE. Contractor selected is capable of supplying the requirements because of their experience within this supply need and have the necessary products to adequately provide these supplies. Contractor selected also has explicit and intimate knowledge of the specific project for which those supplies are required. Notwithstanding, interested parties who believes they are capable of meeting Forest Service requirements as stated herein may submit a response that shows clear and convincing evidence that competition would be advantageous to the Government in future procurements. This notice is not a request for competitive proposals or a solicitation of offers. A determination not to compete the proposed Purchase Order based upon the responses is solely within the discretion of the Government. All questions should be directed to David Easter via email to david.easter@usda.gov no later than 11:59 am CST 5 calendar days after the date of this announcement. Telephone inquiries are discouraged.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:12444122Q0129
  1. Special NoticeCurrentSep 14, 2022

    12444122Q0129 Myers Grinder Pumps and Rail Packages

    Notice 9fa6862e760c43959e227ae6a99fb77a on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Two (2) R2PD-45 special power-drive reels and one (1) 850-foot RPT2-SP-8 Teflon tubing bundle
-Combined Synopsis11/17/2026
PLEASE SEE ATTACHED SOLICITATION.
-Solicitation11/04/2026
This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the information in Federal Acquisition Regulation (FAR) Part 13 using Simplified Acquisition Procedures (SAP). This announcement constitutes the only solicitation; a written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This combined synopsis/solicitation will be posted to the System for Award Management at https://sam.gov/ and/or Procurement Integrated Enterprise Environment (PIEE) at https://piee.eb.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. The RFQ number is N5005427Q0018. This solicitation documents and incorporates provisions and clauses in effect though FAC 2026-01 and the DFARS Change notice 20260507. The Mid-Atlantic Regional Maintenance Center (MARMC) requests responses from qualified sources capable of providing the Impeller Pump that are identified in the attached Statement of Work (SOW). All parts shall be new. No refurbished or used parts will be accepted.
-Combined Synopsis11/05/2026
SOLICITATION # FA813227Q0004_ SERFILCO PUMPS FOR PLATING SHOPThe Air Force Sustainment Centers Maintenance Contracting Branch (AFSC/PZIMC) at Tinker Air Force Base, Oklahoma, intends to award a Firm Fixed Price (FFP) contract for SERFILCO PUMPS FOR PLATING SHOP. ****************PLEASE SEE CSS AND ATTACHED DOCUMENTS FOR FURTHER DETAILS AND INSTRUCTIONS**************
-Combined Synopsis11/09/2026
** NOTE **: The below questions and answers regarding the Publications and Packaging CDRL portions of the solicitation are posted here for your reference: Packaging - Attachment 15 Question(s) 1. Section F calls out preserving all exterior unpainted metal surfaces in accordance with MIL-STD-2073 and coating said surfaces with preservative MIL-PRF-16173, Grade 1. In MIL-PRF-53051D, Section 3.10, it states that CARC paint shall not be applied to surfaces greater than 400F which means our metallic exhaust guard would not be painted. Is this coating able to be applied to surfaces greater than 400F? Additionally, is there a reason that preservative MIL-PRF-16173, Grade 1 is not listed in MIL-PRF-53051D anywhere? 2. Is there a MIL, ISO, FDA or some other standard that the corrosion preventative coating for food handling machinery and equipment must meet? Additionally, why is this not a requirement for the Type II - Pump Assembly, Water in MIL-PRF-53051D? The SPI calls out a preservative that can be used on bare metal when the item is in storage to prevent corrosion. I’m not sure where MIL-PRF-53051D is coming from, it maybe from the PD, which would be engineering and could be focusing on the inside of the pump. If the contractor wants to use a different preservative on non-metal, it will need to be from MIL-STD-2073, Appendix J and that preservative would need to meet the functionality of MIL-PRF-016173. 3. As far as the packaging preservative goes, these systems are painted with Chemical Agent Resistant Coating (CARC) which has anti-corrosive properties already in it as called out in MIL-PRF-53051D which is the MIL-PRF that these systems are manufactured too. Additionally, they are required based on the solicitation to be delivered in heat treated wooden crates. Is the packaging team stating that the preservative needs to be applied to the wooden crate or the exterior of the unit? The internals of the pump system are already cast aluminum and stainless steel which are inherently corrosion resistant.” I’m not seeing where MIL-PRF-53051D was listed in packaging. I reviewed the pkg contract language and CDRLs and didn’t see where it was mentioned. Did the contractor see that in the Purchase Description? If so, that would be an engineering question to answer. As far as the wooden crate, it needs to follow heat treatment requirements per DOD 4140.65M and the requirements of the International Standards for Phytosanitary Measures 15 (ISPM), Regulation of Wood Packaging Material as laid out in Section D of the contract. *** Amendment 0005 is issued to extend the proposal due date out to 16 Oct 2026, change the FOB point from Origin to Destination for the production CLINs, revise the Section C Statement of Work (SOW) to remove references to Provisioning, Publications, and Technical Manuals, revise the list of addenda and attachments in Section J, remove select CDRLs and attachments as required, add a CDRL for a Commercial Off-the Shelf (COTS) Operator's Manual in Section J for government review prior to approval, and add/delete or update any clauses or provisions as required (especially due to the revolutionary FAR overhaul). *** Amendment 0004 is issued to extend the proposal due date out to 05 Dec 2025 *** *** Amendment 0003 is issued to extend the proposal due date out to 21 Nov 2025 *** *** Amendment 0002 is issued to extend the proposal due date out to 31 Oct 2025 *** *** Amendment 0001 is issued to extend the proposal due date out to 10 Oct 2025 *** Item: Pumping Assembly, Water NSN: 4320-01-691-1630 P/N: M53051-2-2 (CAGE 81349, Government) Qty: 14 each basic, 14 each option Packaging: Military A FOB: Destination Contract Type: Definitive contract with 100% option for 365 days Notes: This procurement is established as a 100% Total Small Business SetAside. First Article Testing (FAT) is required (provision for FAT waiver is allowed) and Government approval must be obtained prior to manufacturing the production quantity. Part number M53051-2-2 (Water Pump, 600 GPM) is built utilizing the standards listed in MIL-PRF-53051D (dated 20 Apr 2022). A copy of the MIL-PRF is attached in the Pre-Solicitation notice for this opportunity. The solicitation includes a Statement of Work (SOW) in Section C, with a list of packaging data, safety/security and hazardous material data required by the Government. These details are listed on the solicitation as narratives, Contract Data Requirements List (CDRLs) and attachments. There are 7 CDRLs and 7 attachments that support the CDRLs. Thoroughly review the solicitation document and amendments for all requirements prior to submitting your proposal. ***** Contact the Contract Specialist to obtain all of the CDRL and attachment documentation via the DoD Safe Site. *****
-Solicitation10/16/2026

Additional Details

Solicitation Number

12444122Q0129

Archive Date

Not specified

Office Address

SAINT PAUL, MN, 55108