Sandpoint Ranger District HVAC Preventative Maintenance
Archived on December 4, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:30 PM UTC−08:00
- Posted
- November 14, 2025
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of AgricultureFOREST SERVICE
Notice details
- Office
- USDA-FS, CSA INTERMOUNTAIN 1
- Place of performance
- Idaho, 83864
- PSC
- J041: MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
- Last updated
- Aug 21, 2026
Identifiers
- Solicitation number
- 1284LL26Q0010
- Notice ID
- 7624fcfc54b64cbda9a404b6ee3019b0
Description
This requirement is for the Contractor to provide all labor to complete maintenance and repair services on the Heating, Ventilation, Air Conditioning (HVAC) and refrigeration systems at the Sandpoint Ranger District building, to include the geothermal loops. Contractor will be required to complete all Quarterly, Semi-Annual, and Annual preventative maintenance, providing all incidentals and materials. The Contractor shall submit a service report to the Contracting Officer’s Representative (COR) at the completion of each service visit and with the service report, the Contractor shall include corrective maintenance required.
Sandpoint Ranger District HVAC Preventative Maintenance - Amendment 1
The purpose of this amendment is for the following purposes:
1) Added a bullet point under the Quarterly Requirements for the Energy Recovery Ventilator (ERV) to inspect all components and ensure proper functioning of duct heater.
2) Deletion of all references to Variable Refrigerant Flow Fan Coils as there are none in the system at this location.
3) Deletion of all references to Branch Selector Boxes as there are none in the system at this location.
4) Clarification that exhaust fans are specific to the HVAC system.
5) Clarification that the Contractor will be responsible for ensuring proper replacement of any belts per manufacturer specifications.
6) Clarification that there is only one ductless mini-split system.
All changes are indicated with a vertical line in the left margin of the "a. 1284LL26Q0010_CSS_Amend1.docx" and "b. Sandpoint HVAC PWS.docx" documents. No changes were made to any other documents.
The hour and date for receipt of quotes has been extended to November 19, 2025 at 4:30 pm Pacific Time.
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Showing 9 of 9 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 669.75 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 71.51 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 82.58 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 6.9 MB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 366.27 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 118.87 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 85.04 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 78.17 KB | |||
| Combined Synopsis/Solicitation | FOREST SERVICE | Nov 14, 2025 | 88.2 KB |
Lifecycle
1284LL26Q0010- Combined Synopsis
- 2×Combined SynopsisCurrentOct 31, 2025
Sandpoint Ranger District HVAC Preventative Maintenance
Similar Opportunities
Additional Details
Solicitation Number
1284LL26Q0010
Archive Date
Dec 4, 2025
Office Address
Ogden, UT, 844012310