GovChime

HIGH RESOLUTION X-RAY DETECTOR

Overview

Response deadline
3:00 PM UTC−04:00
Posted
August 24, 2021
Notice type
Combined Synopsis/Solicitation
Agency
Department of CommerceNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

Notice details

Office
DEPT OF COMMERCE NIST
Place of performance
Gaithersburg, 20899
Last updated
Sep 25, 2026

Identifiers

Solicitation number
1333ND21QNB680434
Notice ID
f03d59a8fd694316b1d9e1b98029687e

Description

Amendment II: The purpose of this Amendment is to extend the due date/time for quotations due to the fact no quotations were received. The due date/time for quotations is hereby extended as follows: From: August 23, 2021 @ 12pm EST To: August 27, 27, 2021 at 3pm EST All other terms and conditions remain unchanged. Amendment I: The purpose of this Amendment is to address vendor questions received in regard to the requirements. See below: Question: Can you please confirm the kV required for the source/tube? Answer: To clarify, we do not need an x-ray source or tube. We already have a device called EBIT that produces X-ray from highly charged ions. We require an x-ray detector that can be used to observe the broad spectrum of X-ray emissions from our EBIT device. The operation of the EBIT is variable, producing X-rays with energies from 0.2 keV to 10 keV, depending on the electron beam energy selected. Question: Do you require a probe, if so what length? Answer: The detector must be mountable within the vacuum chamber. No specific probe is required, but details must be provided for mounting the detector and its integrated heat sink. NIST will use the mounting information to make the appropriate adapter to the EBIT device. Question: Is this a modular design to be mounted inside the vacuum chamber? Answer: The detector and its integrated heat sink will be mounted as close as possible to the aperture from which X-ray is emitted by the EBIT. It seems clear that the detector and heat sink must be modular. To get as close as possible to this x-ray emission aperture, the detector/heatsink package must be mountable within the vacuum fitting for the viewport, which is on a 4.5” Conflat flange. Question: How do you intend to mount the detector? Answer: The detector along with its heat sink must have mounting features, which NIST will use to fasten it to an alignment structure designed to optimize light collection from the EBIT. Mechanical details of the detector mounting mechanism must be provided so that NIST can build the adapter. All other terms and conditions remain unchanged. HIGH RESOLUTION X-RAY DETECTOR per the requirements as set forth in the attached combined synopsis/solicitation. See attachment for complete details.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Joni L. Laster

Secondary Contact

Patrick K Staines

Documents

No documents available.

Lifecycle

Solicitation:1333ND21QNB680434
  1. Combined Synopsis
  1. 4×
    Combined SynopsisCurrentAug 10, 2021

    HIGH RESOLUTION X-RAY DETECTOR

    Notice f03d59a8fd694316b1d9e1b98029687e on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

1333ND21QNB680434

Archive Date

Sep 11, 2021

Office Address

GAITHERSBURG, MD, 20899