Notice ID: 2bc9edacd2ca45b791425bb57ece4bfdJustificationAwarded
36--HEATPULSE FLOWMETERS
Awarded on August 9, 2024. Full description on SAM.gov.
Overview
- Posted
- August 9, 2024
- Notice type
- Justification
- Agency
- Department of the InteriorUS GEOLOGICAL SURVEY
Notice details
- Office
- OFC OF ACQUISITION GRANTS-DENVER
- Last updated
- Sep 9, 2025
- Award date
- Aug 9, 2024
- Award amount (SAM.gov award notice)
- Not specified
Identifiers
- Solicitation number
- 140G0224Q0163
- Notice ID
- 2bc9edacd2ca45b791425bb57ece4bfd
Description
HEATPULSE FLOWMETERS THIS IS NOT A REQUEST FOR QUOTE. THIS IS A NOTICE OF THE GOVERNMENT'S INTENT TO ISSUE A SOLE SOURCE AWARD. This Notice is to announce that the U.S. Department of the Interior (DOI), U.S. Geological Survey (USGS), Ohio-Kentucky-Indiana Water Science Center; Indianapolis, IN is proposing to negotiate a contract with Rapid Creek Research, on a sole source basis. This requirement is for the purchase of Two (2) Cypress Heat Pulse Horizontal Groundwater Flowmeter System, installation, support, and monitoring for 12 months. The proposed action is for products/services for which the Government intends to solicit and negotiate with only one source under the authority FAR 13.106-1(b)(1). The reason justifying this sole source procurement is that the Government believes only one responsible source can provide the products/services that will satisfy the agency's requirement. U.S. Geological Survey (USGS), Ohio-Kentucky-Indiana Water Science Center; Indianapolis, IN requires the Rapid Creek Research (RCR) heat-pulse flowmeter (HPFM) as it is the only technology capable of making high-frequency measurement of groundwater flow rate and direction using solar-only power. The heat-pulse flowmeters must be capable of operating with either grid power or only solar power, interfacing with Campbell data loggers, and be accurate and durable for long-term deployment in a standard monitoring well. The flowmeter system shall allow for recording of raw and processed data that can be transmitted by telemetry to a database that displays and allows access to high frequency data in real time. The instrument can be used with various telemetry options including cellular data modem and transmission to satellite communication systems. In the event of interruptions in telemetry the instrument should be capable of storing data internally for up to 30 days. The instrument shall display current data being collected on a laptop computer and allow downloading of stored data. The following salient characteristics are provided: Specifications/Description medium: fresh, sea, or polluted water measurement principle: heat pulse with measurement of thermal plume response measure temperature of probe thermistors: excitation and 24 bit A:D measurement on board within probe (n=8) temperature measurement accuracy and resolution: 0.1 C accuracy and 0.001 C resolution range of calibrated flow s: 0.2 ft/day to 100 ft/day (0.1 m/day to 30 m/day) velocity accuracy: 10% direction accuracy: 10 degrees maintain heater setpoint amps: digital input using digital potentiometer under remote program control measure heater amps: analog output to datalogger heater control: digital port switched from datalogger topside board communication: communicate with CR1000(X) over RS485 topside board temperature: digital temperature fault reporting: open or short thermistor, ADC out of range, bad ADC external noise probe memory: serial number, calibration coefficients and date probe board temperature, relative humidity: digital sensor digital compass on probe board: optional cable and connectors: marine grade 12 conductor communication: Campbell Scientific Loggernet, SDI-12, Modbus RS485 Probe Diameter: 1.75 in (4.45 cm); polyester packer allows use in screened monitoring wells 2 in to 4 in (5.1 cm to 10.2 cm) Probe Length: 19.7 in (50 cm) including packer Controller Box: 20 in (50.8 cm) x 18 in (45.7 cm) x 9 in (22.9 cm) fiberglass reinforces polyester, NEMA 12/13 Power: 12-26 VDC, typically with 84 amp-hr AGM battery and 90 watt solar panel, depending on solar availability This is a sole source notice published for informational purposes only and not a request for competitive quotes. Therefore, no solicitation document exists for this requirement. However, all responsible parties interested in responding to this notice are invited to submit a capability statement by the time and date specified in this notice that provides sufficient details for consideration by the Government, via email to: ldwilliams@usgs.gov. The determination not to compete the contract based on the responses to this notice is solely within the discretion of the Government. Phone calls will not be accepted in response to this notice. All information submitted should support the offeror's capability to provide the services required and shall be furnished at no cost or obligation to the Government. Responses must be in writing and must provide clear and concise documentation indicating an offeror's bona fide capability to provide these services. Verbal responses are not acceptable and will not be considered. The Government reserves the right to cancel this requirement.
Award Overview
Award Number
140G0224P0227
Award Amount (SAM.gov award notice)
Not specified
Award Date
Aug 9, 2024
Awardee
Not specified
Original Solicitation
Notice ID: 2bc9edacd2ca45b791425bb57ece4bfd
Posted Date: Aug 9, 2024
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $22.3KSigned Mar 20, 2025
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
140G0224Q0163- Awarded
This opportunity has been awarded.
- Special NoticeJul 19, 2024
36--HEATPULSE FLOWMETERS
- Sole Source / J&ACurrentAug 9, 2024
36--HEATPULSE FLOWMETERS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
140G0224Q0163
Archive Date
Sep 8, 2024
Office Address
DENVER, CO, 80225