GovChime
Notice ID: baa2b5c8604d4688b18c6a3d9dd550c4Award NoticeAwarded

Z--STORMCAT CBM ORPHAN WELL PLUGGING

Awarded on May 25, 2021. Full description on SAM.gov.

Awarded tounder 140L6221P0041 (source: SAM.gov award notice)• $90.2K

Overview

Posted
May 25, 2021
Notice type
Award Notice
NAICS
213112: Support Activities for Oil and Gas Operations
Agency
Department of the Interior

Notice details

Last updated
Sep 9, 2025
Award date
May 25, 2021
Award amount (SAM.gov award notice)
$90.2K

Identifiers

Solicitation number
140L6221Q0013
Notice ID
baa2b5c8604d4688b18c6a3d9dd550c4
Award number (PIID)
140L6221P0041

Description

STORMCAT CBM ORPHAN WELL PLUGGING

Full description on SAM.gov

Award Overview

Award Number

140L6221P0041

Award Amount (SAM.gov award notice)

$90.2K

Award Date

May 25, 2021

Awardee

Awardee UEI

Z8NTC3D1KR64

Original Solicitation

Notice ID: baa2b5c8604d4688b18c6a3d9dd550c4

Posted Date: May 25, 2021

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

1
  • 140LL027C0004
    WYODAK ENERGY SERVICES, LLC
    Department of the InteriorNAICS 213112
    $410.8KSigned Nov 12, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:140L6221Q0013
  1. Combined Synopsis
  2. Awarded

This opportunity has been awarded.

  1. 2×
    Combined SynopsisMar 29, 2021

    Z--STORMCAT CBM ORPHAN WELL PLUGGING

    Notice 50e342ec79e544a2b2932ecd211f91e1 on SAM.gov

  2. AwardedCurrentMay 25, 2021

    Z--STORMCAT CBM ORPHAN WELL PLUGGING

    Notice baa2b5c8604d4688b18c6a3d9dd550c4 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Monitoring Well Plugging Phase III Ford Ranch Orphan
84%
AwardedOpen
E-Seal Technology from Los Alamos National Laboratory offers a transformative answer to the world’s aging wells. E-Seal is a liquid sealant that flows like water until an applied electric field steers its engineered micelles directly into the sub-millimeter cracks where cement and polymer treatments physically cannot reach, then transforms into a durable, jammed plug that holds even after the power is switched off. With an estimated tenfold cost advantage over current sealants, the ability to mitigate galvanic corrosion of well casings, and an AI-guided control system that adjusts voltage in real time as the seal forms, E-Seal stands as the first intelligent, actively steered wellbore repair platform built for the leak pathways that define modern well failure. Overview E-Seal begins as a low-viscosity, water-like fluid carrying specially engineered surfactant micelles and stabilized colloidal particles. When an electric field is applied across the target zone, three electrokinetic forces act in concert: Electrophoresis pulls the charged micelles toward the fracture, electro-osmosis drives bulk fluid flow into tight constrictions, and dielectrophoresis uses non-uniform field gradients to push larger micelle clusters into the narrowest gaps. As the micelles concentrate inside the crack, the dispersion transitions from a flowing liquid into a jammed, high-viscosity network that bridges the fracture wall-to-wall and resists pressure-driven flow even after the field is removed. Technology Description At the molecular scale, surfactant molecules in the E-Seal fluid self-assemble into micelles above the critical micelle concentration, and cement surfaces in downhole brine naturally develop an electrical double layer that interacts with these approaching charged carriers. In high-salinity brines containing divalent cations such as calcium and magnesium, the double layer compresses, inter-particle repulsion drops and micelles aggregate and adsorb onto the cement face; silica or alumina nanoparticles then reinforce the network as physical anchoring points, producing a mechanically robust plug that maintains low permeability over time. Optional additives further tune the sealant to site conditions. Trivalent cations of lanthanum and cerium raise ionic strength, accelerate micelle aggregation and can react with carbonate species in carbonate-bearing brines to precipitate low-solubility mineral phases as a secondary plugging mechanism. Crosslinked polyacrylamide derivatives, sodium polyacrylate and sulfonated polyacrylamide gel particles also can be incorporated to reinforce the seal through polymer crosslinking or by swelling on contact with the leaking fluid. Layered on top of the chemistry is an AI/ML-based real-time control pipeline that monitors sealing progress and dynamically recommends voltage adjustments as conditions evolve in the wellbore, positioning E-Seal as an actively steered rather than passively injected treatment. The applied potential difference carries a second benefit beyond transport: It helps mitigate galvanic corrosion of the well casing, addressing a long-standing integrity concern in parallel with the primary sealing function. Because the underlying transport mechanism is electrokinetic rather than pressure-driven, the same chemistry is well suited to micron-scale defects in any cementitious, porous or fractured medium, including concrete infrastructure, dams, tunnels, underground vaults, waste containment structures, clay and bentonite engineered barrier systems, repository backfill, corroded metallic interfaces, leaky caprocks, fault damage zones, abandoned mine workings and underground storage caverns. Advantages Reaches sub-millimeter microfractures and microannuli that cement squeeze jobs cannot penetrate because of particle bridging at the fracture mouth Maintains sealing performance under the high temperatures, high pressures, and aggressive brine chemistries where polymer and resin sealants typically break down Delivers an estimated tenfold cost advantage over contemporary sealing approaches Mitigates galvanic corrosion of well casings as a built-in secondary benefit of the applied electric field Uses an AI-guided control system that tracks sealing progress and adjusts voltage dynamically for a smarter, more reliable repair Applies broadly beyond wellbores to concrete, containment, and subsurface infrastructure wherever micron-scale leak paths drive failure Market Applications Oil and Gas Recovery (legacy well plugging and abandonment, sustained casing pressure remediation, methane leak compliance) Geothermal Energy (well integrity repair, asset life extension for high-cost geothermal wells) Carbon Capture (caprock and wellbore integrity for long-term CO2 containment) Critical Infrastructure (dams, tunnels, underground vaults, reservoirs) Mining and Subsurface Storage (abandoned mine workings, underground storage caverns, fault zones) S-197080 U.S. Patent pending LA-UR-26-25954 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
38%
Special Notice10/01/2026
The Bureau of Land Management has a need to plug and abandon 11 wells in Grand County, Utah that have been placed into orphan status with no identifiable responsible party. In accordance with the requirement of 43 CFR 3162.3-4 (a) (b) and per Section XII of the Bureau of Land Management Onshore Oil and Gas Order No. 1, III., XII., A., B., these wells must be plugged and abandoned (P&A), the locations cleaned up, and the surface reclaimed.
95%
AwardedOpen
MONITOR WELL PLUGGING PHASE 2
90%
AwardedOpen
FEDERAL 1-8 OIL WELL PLUGGING AND RECLAMATION
90%
AwardedOpen

Additional Details

Solicitation Number

140L6221Q0013

Archive Date

Jun 9, 2021

Office Address

CHEYENNE, WY, 82009