GovChime
Notice ID: 6e65e45b2ff44dc39fff929572b064f8Award NoticeAwarded

Z--REPLACE ROLLING GRILLES SYSTEM (OPAL BEACH)

Awarded on June 11, 2024. Full description on SAM.gov.

Awarded tounder 140P5224P0066 (source: SAM.gov award notice)• $74.0K

Overview

Posted
June 11, 2024
Notice type
Award Notice
NAICS
238290: Other Building Equipment Contractors
Agency
Department of the Interior

Notice details

Place of performance
STATE HWY 399 SANTA ROSA AREA, Navarre, FL
Last updated
Sep 9, 2025
Award date
Jun 11, 2024
Award amount (SAM.gov award notice)
$74.0K

Identifiers

Solicitation number
140P5224Q0031
Notice ID
6e65e45b2ff44dc39fff929572b064f8
Award number (PIID)
140P5224P0066

Description

Upward Coiling ROLLING GRILLES Systems, Six (6) Each MODEL 671: Overhead Door Corp, 5-1" W x 8'3" H CURTAIN: Straight lattice, Stainless 304 #4 OPERATION: Manual, Pushup, right hand COUNTER-BALANCE SHAFT: solid 1" drive shaft with corrosion inhibitive baked on coating, stainless-steel spindles with torsion springs and spring adjusters. BOTTOM BAR: double angle #4 type 304 Stainless Steel BRACKET: Stainless 304 #4 BEARINGS: Heavy-Duty (permanently lubricated ball or roller, corrosion inhibitive zirconium treatment) OPERATION: Manual, Pushup, right hand GUIDES: Stainless 304 #4, Structural Angle, High Usage Guides MOUNTING: Concrete, Face Mount Z guides, Lintel - Concrete header HOODS: Stainless 304 #4, Fascia Material - Stainless 304 #4 INSTALALTION by certified technicians. Firm-Fixed Price includes removal/disposal of existing grille systems (construction debris). Acquisition conducted IAW FAR PART 13 - SIMPLIFIED ACQUISITION PROCEDURES and PART 36 - CONSTRUCTION (as applicable). BASIS OF AWARD: Best Value considering price and other factors (readily discernible value indicators) based upon comparative evaluation of offers. Award made to 3rd lowest price among 11 quotations or offers received in response to solicitation.

Full description on SAM.gov

Award Overview

Award Number

140P5224P0066

Award Amount (SAM.gov award notice)

$74.0K

Award Date

Jun 11, 2024

Awardee

Awardee UEI

NTHFTYXSNH94

Original Solicitation

Notice ID: 6e65e45b2ff44dc39fff929572b064f8

Posted Date: Jun 11, 2024

Original Response Deadline: Not specified

Contacts

Documents

No documents available.

Lifecycle

Solicitation:140P5224Q0031
  1. Solicitation
  2. Awarded

This opportunity has been awarded.

  1. SolicitationMay 9, 2024

    REPLACE ROLLING GRILLES SYSTEM (OPAL BEACH)

    Notice 606cfe83eb2b4950aa59c2e72fb8e3f6 on SAM.gov

  2. AwardedCurrentJun 11, 2024

    Z--REPLACE ROLLING GRILLES SYSTEM (OPAL BEACH)

    Notice 6e65e45b2ff44dc39fff929572b064f8 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Amendment 0002: Extend Bid due date to May 13,2026 2:00 PM CT. 1. Consider a quote for materials only. No. The Government will not consider a materials-only quote for this requirement. The solicitation is for a complete firm-fixed-price generator replacement, including all labor, materials, tools, equipment, supervision, removal of existing equipment, installation, electrical integration, commissioning, load testing, training, and closeout documentation. Offerors must submit a complete turnkey quote that satisfies the full Statement of Work. Materials-only pricing will not be considered responsive to the solicitation. All other terms and conditions of the solicitation and Statement of Work remain unchanged. 2. Please advise if replacing the roof structure and new generator exhaust shall be included in the SOW as an alternate. The existing generator roof/cover structure is not identified in the Statement of Work for replacement. The Government does not intend to add replacement of the roof/cover structure as an alternate at this time. The existing roof/cover structure is bolted to the supporting steel posts and can be temporarily unbolted and removed, if necessary, to allow removal of the existing generator and installation of the new generator. The contractor shall field-verify existing conditions and determine the means and methods necessary to perform the work. If the contractor determines that temporary removal of the existing roof/cover structure is necessary, the contractor shall include temporary removal and reinstallation of the existing roof/cover structure in its price. If temporarily removed, the existing roof/cover structure shall be protected from damage and reinstalled in its current configuration unless otherwise directed by written solicitation amendment. Replacement of the roof/cover structure is not included in the current scope. The new generator exhaust shall be provided and installed in accordance with the generator manufacturer¿s requirements, applicable codes, and the Statement of Work. The contractor may reuse existing exhaust routing/components only if compatible with the new generator, manufacturer requirements, and applicable code. Any required exhaust modifications necessary for a complete, operational, code-compliant installation shall be included in the contractor¿s price. 3. Is there a requirement to replace the wire from the building electrical panel to the transfer switch? Replacement of the existing wire from the building electrical panel to the transfer switch is not included in the Statement of Work. The existing underground/building feeder route is located within the historic site context and is not intended to be removed, replaced, or re-routed under this contract. The contractor shall not disturb historic ground or replace the existing building-to-transfer-switch wiring unless specifically directed by written solicitation amendment. The contractor remains responsible for making the required exterior equipment connections, terminations, grounding/bonding, and code-compliant installation of the new generator and automatic transfer switch using the existing service conditions provided. Any work shall be limited to the generator/ATS replacement scope identified in the Statement of Work. 4. Sherwin-Williams is asking what the exact color number is that the end-user is looking for, if they have a specific manufacturer's color in mind. The contractor should submit actual color samples or manufacturer color documentation for review before ordering. The color needs to be reviewed in context with the Melrose setting and existing site conditions before final approval. Of the colors listed, Bottle Green 6007, Moss Green 6005, and Pine Green 6028 appear to be the closest options for consideration. Emerald Green 6001 appears less appropriate based on the name and general color tone, but final determination should be based on actual samples. The Government is not identifying a specific manufacturer¿s color at this time. Final color approval should remain subject to COR review of submitted color samples/documentation prior to ordering.
-Combined Synopsis05/13/2026
Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Revolutionary FAR Overhaul (RFO) (FAR) subpart 12.2, Solicitation, Evaluation, and Award as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01 (eff. 03/13/2026) FAR Deviation JAN 2026 (eff. 01/22/2026) VAAR DEVIATION FEB 2026 (eff. 03/17/2026) VAAM Alert 26-02 (eff. 10/28/2025) Acquisition Policy Flash 26-26 eff. 03/17/2026) 4. This solicitation is for Roll Up Door Replacement and the solicitation number is 36C25627Q0092. This solicitation is a 100% SDVOSB set-aside, and the Government anticipates awarding a firm-fixed price contract from this solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 238290, with a small business size standard of $22M. The FSC/PSC is N099 Installation Of Equipment- Misc. The Central Arkansas Veterans Healthcare System is seeking to purchase the service for isolation Valves installed for steam and condensate lines IAW with attached statement of work. All interested companies shall provide quotations for the following: Supplies/Services: See Section B.2, Cost/Price Schedule Place of Performance/Place of Delivery Address: Eugene J. Towbin Healthcare Center Central Arkansas Veterans Healthcare System 2200 Fort Roots Drive North Little Rock, AR 72114 Site visit is scheduled for November 06, 2026, time 10am . Location of site visit is stated in attached SOW. POC is Justin Harper, Justin.Harper2@va.gov All questions are due by November 10, 2026 3PM CST. All quoters shall submit the following: Quotes should be emailed to joseph.warren@va.gov and received no later than 3:00 PM CST, November 18, 2026. Email subject line shall include, RFQ 36C25627Q0092 Roll Up Door Replacement . Quotes shall be submitted IAW Provision 52.212-1 Instruction to Offerors. Point of Contact Joseph Warren Contracting Officer joseph.warren@va.gov
-Combined Synopsis11/20/2026
This is a combined synopsis/solicitation for commercial services prepared in accordance with FAR Subpart 12.6. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is issued as a Request for Quote (RFQ).
-Combined Synopsis11/06/2026
AMENDMENT 0003. Updated Statement of Work - correction of French Drain lineal feet. Page 6 STRI Replace Plumbing, Mold Remediation, HVAC Installation, and Crawlspace Encapsulation
-Combined Synopsis05/29/2026
FY26 Replace Backflow Preventers at the Natchez National Historical Park Amendment 002: ****REVISED STATEMENT OF WORK **** 02.02.26
-Combined Synopsis02/05/2026

Additional Details

Solicitation Number

140P5224Q0031

Archive Date

Jun 26, 2024

Office Address

TUPELO, MS, 38804