GovChime
Notice ID: facdb7abbd7b452bbec8c82072d3fa57Combined Synopsis/SolicitationArchived

Z--WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

Archived on March 28, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 PM MDT
Posted
March 11, 2026
Notice type
Combined Synopsis/Solicitation
NAICS
332321: Metal Window and Door Manufacturing
Agency
Department of the InteriorBUREAU OF RECLAMATION

Notice details

Office
GREAT PLAINS REGIONAL OFFICE
Last updated
Nov 3, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
140R6026Q0011
Notice ID
facdb7abbd7b452bbec8c82072d3fa57

Description

WAREHOUSE OVERHEAD DOORS FOR LOCATIONS IN PLATTE AND NATRONA COUNTIES.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (11)

  • Sol_140R6026Q0011_Amd_0004.pdf

    227 KBAdded in Combined Synopsis/Solicitation version 6Posted
    Download
  • Q___A_-_AMDMNT_NO__00004_0004.pdf

    49 KBAdded in Combined Synopsis/Solicitation version 6Posted
    Download
  • Sol_140R6026Q0011_Amd_0003.pdf

    202 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • PWS_Roll_up_Doors_AMDMNT_00003_0003.pdf

    252 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Sol_140R6026Q0011_Amd_0002.pdf

    202 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Pictures_0002.pdf

    2.2 MBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Sol_140R6026Q0011_Amd_0001.pdf

    202 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • Pictures_0001.pdf

    1.7 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • Sol_140R6026Q0011.pdf

    259 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • Performance_Work_statement_Roll_up_doors_11_18_2025.pdf

    232 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 140R6026Q0011_pkg.pdf

    386 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

    Notice 94e737aeb9ca411c832b02ce27455303 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    Z--WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

    Notice 14db8b2b19c34aabb3b6c3577a0406b4 on SAM.gov

  3. 3
    Version 3Combined Synopsis/SolicitationArchived

    Z--WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

    Notice 9a7ae7e55a814fffb1dfe964a70c3ec6 on SAM.gov

  4. 4
    Version 4Combined Synopsis/SolicitationArchived

    Z--WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

    Notice 06c29004a25843eb93a9d5e82c404428 on SAM.gov

  5. 6
    Version 6Combined Synopsis/SolicitationArchivedCurrent

    Z--WY - WAREHOUSE ROLL-UP AND SECTIONAL OVERHEAD DOOR

    Notice facdb7abbd7b452bbec8c82072d3fa57 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Solicitation Amendment 0002 for DK Boom spray rig for flat-bed truck
-Combined Synopsis11/13/2026
STATEMENT OF WORK / REQUEST FOR QUOTE A. INTRODUCTION: 1. The Federal Bureau of Prisons (FBOP), FCC Lompoc, 3901 Klein Blvd., Lompoc, CA 93436, is seeking quotes from qualified vendors for the supply and delivery of nine (9) complete fire escape door assemblies, including doors, frames, and all required hardware. The doors are for a prison facility application and must meet all relevant local, state, and federal fire and life safety codes. 2. "Equal or Better" Product Substitution: Proposals must meet or exceed the specified product quality. If an alternative product or component is offered, the vendor must submit all technical documentation, certifications, and test results for consideration. 3. Government's Right of Final Technical Acceptance: The government retains the sole and final authority to determine technical acceptance for all submitted products, based on the provided documentation and compliance with stated standards. B. SCOPE OF WORK: 1. The vendor shall provide all materials as specified below. All components must be new, U.L. Listed or labeled by a recognized testing agency acceptable to the Authority Having Jurisdiction (AHJ) and conform to the standards referenced herein. C. TECHNICAL SPECIFICATIONS: TABLE 1: COMPONENTS: All units shall be identical unless otherwise noted. Component Requirement Quantity 9 Complete Door Assemblies Door Size 36" wide x 80" high x 2" thick Door Material Hollow Metal Door, minimum 12 Gauge galvanneal steel Core Ribbed and Insulated (mineral core for fire rating is acceptable/preferred) Fire Rating Rating must be compatible with the wall's fire resistance rating, typically 75% of the wall's rating. See required fire rating for correctional facilities on Table 2 Handing 4 Left Hand Outswing, 5 Right Hand Outswing. Frame Material Minimum 12 Gauge galvanneal steel, fire-rated and labeled Frame Type Knock-down (KD) for drywall/unit masonry or welded for masonry. Frames are to be prepared for 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer. Finish Factory primed for field painting TABLE 2: FIRE RATING: The complete door assembly (door, frame, and all hardware) shall be 90 minutes fire rated. This rating must be compatible with the fire-resistance rating of the specific wall assembly in which the door will be installed, as dictated by the building's fire safety plan and local code requirements. Category Requirement Description Applicable Standards & Agencies Listing & Labeling All components must be listed and labeled by a recognized third-party testing agency acceptable to the Authority Having Jurisdiction (AHJ). Underwriters Laboratories (UL), Intertek (WH), Factory Mutual (FM) Testing Standard Assemblies shall be tested under positive pressure conditions. NFPA 252, ANSI/UL 10C Labeling Visibility A permanent, legible fire rating label must be affixed to both the door and the frame and remain visible after installation for inspection purposes. N/A Code Compliance Vendor must confirm that all components, when installed as an assembly, comply with relevant building and safety codes for correctional facilities (Group I-3 Occupancies, IBC). NFPA 80 (Standard for Fire Doors and Other Opening Protectives) International Building Code (IBC) TABLE 3: HARDWARE SPECIFICATIONS: All hardware must be "listed" or "labeled" for use on a fire-rated assembly, compatible with the specified fire rating, and factory-prepped for ANSI/BHMA Grade 1 standards. Item Requirement Quantity per Door Notes Hinges Heavy-duty steel ball bearing hinges, UL Listed 3 Exit Device Panic Hardware/Fire Exit Hardware (rim or mortise type) self-latching 1 set Must be a crossbar or touch bar device, operable with an applied force of 15 lbs or less. Locking Must be openable from the egress side at all times without special knowledge or tools. Keyed access from the exterior is permitted. 1 set 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer. Door Closer Heavy-duty, adjustable, surface-mounted, UL Listed 1 unit Must be self-closing and ensure positive latching. Seals Smoke and draft control gasketing/seals 1 set Required for a complete smoke-rated assembly. Threshold [Specify if required, e.g., 1/2" beveled aluminum, non-combustible] 1 unit (if required) D. CODE AND STANDARD REQUIREMENTS: 1. All supplied materials and the complete assembly must comply with the latest editions of the following codes and standards (or local equivalents as adopted by the AHJ): NFPA 80: Standard for Fire Doors and Other Opening Protectives NFPA 101: Life Safety Code International Building Code (IBC) International Fire Code (IFC) OSHA requirements for exit routes UL 10C or NFPA 252: Standard for positive pressure fire testing of door assemblies UL 1784: Standard for Air Leakage Tests of Door Assemblies (if smoke rating is required) 2. Vendors must confirm that all components, when installed as an assembly, will bear a permanent, legible label from a recognized third-party testing agency (e.g., UL, Intertek/WH, FM). E. SUBMISSION REQUIREMENTS: 1. Itemized pricing for doors, frames, hardware, and any included accessories. 2. Proposed lead time for manufacturing and delivery to FCC Lompoc 3. Confirmation of compliance with all referenced codes and standards. 4. Cut sheets/product data for all proposed items. F. DELIVERY OF MATERIALS: 1. Deliveries shipped directly to FCC LOMPOC can only be received between 7:30 a.m. and 2:00 p.m., Monday through Friday, excluding Federal Holidays. 2. POC: Mr. Fernando Pena, BOP Engineering Technician, FXPena@bop.gov, or 805-735-2771 3. FBOP will be responsible for receiving or signing deliveries. 4. FCC LOMPOC will provide resources for loading and unloading materials or equipment upon arrival.
-Combined Synopsis11/16/2026
Proposed procurement for NSN 5340014107057 CLEVIS,ROD END: Line 0001 Qty 38 UI EA Deliver To: By: 0113 DAYS ADO This Solicitation may result in an Automated IDC (Indefinite Delivery Contract). The term of the contract/order will be one year or until the aggregate total of orders placed against the contract/order reach 350000.00. The estimated number of orders per year is 1. The Guaranteed Minimum quantity will be 5. Items will be shipped to various CONUS and OCONUS (via consolidation and containerization point) DLA Depots. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Digitized drawings and Military Specifications and Standards may be retrieved, or ordered, electronically. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.
-Combined Synopsis11/23/2026
THIS SOLICITATION AND ANY SUBSEQUENT AMENDMENTS WILL BE POSTED TO THE SAM WEBSITE: SAM.GOV ELECTRONIC SUBMISSION OF QUOTES IS AVAILABLE THROUGH THE SAM WEBSITE. To be considered for award, if the contractor (awardee) is required to implement NIST SP 800-171, the contractor (awardee) shall have a current assessment as detailed in DFARS 252.204-7019 (I.E., not more than 3 years old unless a lesser time is specified in the solicitation) **Items deemed to be Commercial Off The Shelf (COTS) are exempt from NIST SP 800-171 requirement. Must identify and provide information to contracting officer on bid during solicitation period** Please read the contract in its entirety. If you are able to provide a quote be sure to provide the following information in the sections provided below: Page 1 BLK 17a. Provide Contractor's info and cage code. Section A. A1 – 1. Enter The Contractor's POC Section B. – Enter your Quote and any other info we should know. Please quote FOB Destination BREMERTON, WA. Section B. K21 – Check the appropriate box and provide the Manufacturer’s Name, Address and the Country of Manufacturing Section F. – Provide the Lead Time and/or Delivery Date. Section K. - 52.204-24 (d)(1) and (2) Check the applicable boxes Section K. - 52.209-11 (b)(1) and (2) Check the applicable boxes Page 1 - Read box 28 and sign boxes 30 a, b, and c. Return the signed and filled out solicitation with your quote by SUNDAY, 28 SEPTEMBER 2025 7AM FOR YOUR BID TO BE DEEMED RESPONSIVE A SIGNED AND COMPLETED SOLICITATION MUST BE SUBMITTED VIA EMAIL. EMAIL: karl.lindley@dla.mil Please be advised that all communications regarding this requirement are governed by the Procurement Integrity Act. In accordance with FAR 3.104, no proprietary bid information, pricing data, or source selection-sensitive metrics may be exchanged or solicited outside of authorized contracting channels. Thank you for your cooperation in maintaining a fair and ethical procurement process."
-Solicitation11/09/2026
Proposed procurement for NSN 5999014355968 CONTACT ASSEMBLY,ELECT: Line 0001 Qty 652 UI EA Deliver To: DLA DISTRIBUTION WARNER ROBINS By: 0408 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: DLA DISTRIBUTION WARNER ROBINS By: 0210 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.
-Combined Synopsis11/16/2026

Additional Details

Solicitation Number

140R6026Q0011

Archive Date

Mar 28, 2026

Office Address

BILLINGS, MT, 59101