GovChime
Notice ID: 66dc39315fd0db9e885567e77361c86eCombined Synopsis/Solicitation

Elevator Mainenance at Keechelus and Cle Elum Dams

Archived on August 31, 2019. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM UTC−08:00
Posted
August 15, 2019
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Agency
Department of the InteriorBUREAU OF RECLAMATION

Notice details

Office
DENVER FED CENTER
Place of performance
Cle Elum, WA, 98922
PSC
J: MAINT, REPAIR, REBUILD EQUIPMENT
Last updated
Jan 23, 2026

Identifiers

Solicitation number
14R1719Q0023
Notice ID
66dc39315fd0db9e885567e77361c86e

Description

The purpose of this modification is to: 1. Extend the solicitation due date to Aug 16, 2019 at 12:00 pm/PT. 2. Add an optional site visit. SITE VISIT: Site Visit is planned for Aug 13, 2019 at 10:00 pm/PT. If you plan to attend, send an email to tmest@usbr.gov no later than Aug 09, 2019, 12:00 pm/PT. Email shall include the following information: Name of Company: Name of Person(s) Attending: DUNS Number of Company: Phone Number: After site visit please email all questing to tmest@usbr.gov no later than Aug 14, 2019 4:30 pm/PT. Answers will be posted in FBO, under the solicitation number 14R1719Q0023 by Aug 15, 2019, 4:30 pm/PT. All other terms and conditions remain the same. ********************************************************************* The purpose of amendment 1 is to post answers to questions submitted as a result of the solicitation. This does not extend the response due date. Question 1: 6a. " It talks about the State Contractors license as required by Washington. ... but then it states, " The elevator inspector shall also possess a 30 day temp Operating Permit after approving the elevator for temporary use." Can you please clarify. Does this mean we are to have the state inspector involved every 30 days? Our Mechanics are only doing service and the contract is calling out quarterly service, not monthly. We also don't issue Operating Permits, that is done by the State. Unless I am mistaken, and it is run differently through your facility. Answer 1: No state inspector or inspections are needed every 30 days. We have a state operating permit for the units, we need to keep it valid by performing the quarterly and annual inspections. Our staff does the monthly work on the units. Question 2: 6b. What kind of certification are you requiring? The Washington elevator license covers the rack and pinion style conveyances. Our mechanics have experience servicing them throughout their careers, however, the manufacturer will not certify 3rd party mechanics to service their equipment specifically. Their equipment can be serviced off of their maintenance manual. Can you please clarify what the requirements are for the qualifications? Answer 2: Elevator license is required. The contactor must be able to display their abilities by documented servicing of similar rack and pinion elevators. Please provide documented experience servicing rack and pinion elevators. Knowledge only, of these units does not equal experience replacing the safety devices and certifying them. ********************************************************************* The purpose amendment 2 is to: 1. Extend the solicitation until Aug 20, 2019 at 1:00pm PT. 2. Change CLINS 0020, 0050, 0070, 090, 0110 from four (4) Quarterly PMs to three (3) Quarterly PMs. The CLIN changes read as follows: CLIN0020: Base Year: Three (3) quarterly PMs for two rack and pinion elevators. Travel cost for three trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 6 Each at $_______ for a total of $_______. CLIN0050: Option Year 1: Three (3) quarterly PMs for two rack and pinion elevators. Travel cost for three trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 6 Each at $_______ for a total of $_______. CLIN0070: Option Year 2: Three (3) quarterly PMs for two rack and pinion elevators. Travel cost for three trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 6 Each at $_______ for a total of $_______. CLIN0090: Option Year 3: Three (3) quarterly PMs for two rack and pinion elevators. Travel cost for three trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 6 Each at $_______ for a total of $_______. CLIN0110: Option Year 4: Three (3) quarterly PMs for two rack and pinion elevators. Travel cost for three trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 6 Each at $_______ for a total of $_______. 3. Question #1 What is the part number for the safety device? Answer #1 The part is from the company Alimak Hek, Part number is 0163976-127. Question #2 Can we provide our own weights, or do we need to use the Governments: If we use the Governments, do we need to pay? How much? This would be abnormal. Answer #2 You can bring your own weights but there are weights at the facilities for your use. There is no charge for this use. The cost in the Government Furnished Property table is only for reference as to the values of the weights. 4. This Amendment also incorporates the following: 1. FAR Provision 52.204-24, Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment. (AUG 2019) is hereby added to the solicitation. 2. FAR Clause 52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment. (AUG 2019) is hereby added to the solicitation. Note: Third Party: If you have given a copy of this solicitation to someone else, please forward this amendment accordingly. All other terms and conditions remain the same. ********************************************************************* This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers are being requested and a written solicitation will not be issued. Solicitation number 140R1719Q0023 is issued as a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 19-03 dated 07/12/2019. This is a total small business set-aside under NAICS 811310 with an associated small business size standard of $7.5 Million. The Bureau of Reclamation intends to award a Firm Fixed Price Purchase Order, for the acquisition for annual Cat-5 Inspections and quarterly preventive maintenance (PM), for two elevators. One at Keechelus Dam and the other at Cle Elum Dam in Washington State: CLIN0010: Base Year: Five Year or Category 5, ("Cat 5") Inspection for two rack and pinion elevators. Travel will in in conjunction with one of the quarterly PMs in CLIN 0020. This is a Firm Fixed Price line item. (Per attached PWS. 2 Each at $______ for a total of $________. CLIN0020: Base Year: Four (4) quarterly PMs for two rack and pinion elevators. Travel cost for four trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 8 Each at $______ for a total of $______. CLIN 0030: Base Year: Furnish and Install Safety Device pursuant to attached PWS $_________. CLIN 0040: Option Year 1: Annual Inspection of two rack and pinion elevators. Travel will be in conjunction with one of the quarterly PMs in CLIN 0050. This is a Firm Fixed Priced line item. (Per attached PWS). 2 Each at $________ for a total of $_______. CLIN0050: Option Year 1: Four (4) quarterly PMs for two rack and pinion elevators. Travel cost for four trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 8 Each at $______ for a total of $______. CLIN 0060: Option Year 2: Annual Inspection of two rack and pinion elevators. Travel will be in conjunction with one of the quarterly PMs in CLIN 0070. This is a Firm Fixed Priced line item. (Per attached PWS). 2 Each at $________ for a total of $_______. CLIN0070: Option Year 2: Four (4) quarterly PMs for two rack and pinion elevators. Travel cost for four trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 8 Each at $______ for a total of $______. CLIN 0080: Option Year 3: Annual Inspection of two rack and pinion elevators. Travel will be in conjunction with one of the quarterly PMs in CLIN 0090. This is a Firm Fixed Priced line item. (Per attached PWS). 2 Each at $________ for a total of $_______. CLIN0090: Option Year 3: Four (4) quarterly PMs for two rack and pinion elevators. Travel cost for four trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 8 Each at $______ for a total of $______. CLIN 0100: Option Year 4: Annual Inspection of two rack and pinion elevators. Travel will be in conjunction with one of the quarterly PMs in CLIN 0110. This is a Firm Fixed Priced line item. (Per attached PWS). 2 Each at $________ for a total of $_______. CLIN0110: Option Year 4: Four (4) quarterly PMs for two rack and pinion elevators. Travel cost for four trips pursuant to GSA per diem travel rates will be incorporated into the total price for the Quarterly PM. This is a Firm Fixed Priced line item. (Per attached PWS.). 8 Each at $______ for a total of $______. Written, signed quotes on a company letterhead with contact information are due no later than August 8, 2019 by mail to or in person at Bureau of Reclamation, PO Box 620, Grand Coulee, WA 99133, or by electronic mail to tmest@usbr.gov. For information regarding this Request for Quotation, please contact Terry L. Mest, Contract Specialist at 509-633-9327 or Malena Sanderlin, Contracting Officer at msanderlin@usbr.gov or 509-633-9515. The full combined synopsis solicitation is attached.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

Showing 1 of 1 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationBUREAU OF RECLAMATIONAug 15, 2019-

Lifecycle

Solicitation:14R1719Q0023
  1. Combined Synopsis
  1. 4×
    Combined SynopsisCurrentJul 26, 2019

    Elevator Mainenance at Keechelus and Cle Elum Dams

    Notice 66dc39315fd0db9e885567e77361c86e on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-SolicitationOpen
PURPOSE: The purpose of the sources sought is to identify available authorized businesses to provide the requirement for a Crane Load Test at Fairchild AFB. This sources sought notice is for informational and planning purposes only. Pricing information is not being requested at this time. It does not constitute a solicitation and is not to be considered as a commitment by the Government. REQUIREMENT: This notice is issued by the U.S. Air Force, 92d Contracting Squadron, Fairchild AFB, WA. This sources sought is seeking to identify responsible potential sources to test the cranes rated capacity to 125% for the MXS squadron on Fairchild AFB. The Crane Load Test must meet the specifications in accordance with the attached Statement of Work. ANTICIPATED NAICS/SIZE STANDARD: This requirement falls under the NAICS Code of is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, a size standard of $12.5. SUBMISSION OF INFORMATION: All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought notice. A responsible potential sources shall have registered with the System for Award Management (SAM). The response should be no more than five pages providing the following information: Specifications of the MXS Crane Load Test Business name, address, CAGE code Size and socioeconomic classification based on NAICS size standard If claiming a specific small business category, provide supporting documentation Point of contact including email and phone number Please respond to this request by 19 November 2026 at 10:00 AM Pacific Time
-Market Research11/19/2026
AMENDMENT 0001 is to respond to questions received from vendors by Oct. 29, 2026 at 5:00 pm EDT. This Amendment needs to signed and returned with your quote. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C26027Q0091 is issued as a Request for Quotation (RFQ) for removal of approximately 3,200 gallons of E85 gasoline by pumping out tank and disposal/recycling of station in accordance with the Statement of Work at the Southern Oregon Rehab Center & Clinics in White City, OR. This acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov.
-Combined Synopsis11/04/2026
This sources sought notice is for INFORMATIONAL PURPOSES ONLY. This is NOT a request for proposal, quotations, or bids. The Department of the Interior, Interior Region 10 – California Great Basin, requests responses from Small Business, 8(a), Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZONE, and/or Women Owned Small Business (WOSB), and Indian Small Business Economic Enterprise (ISBEE) contractors interested in providing annual inspections of cranes and hoisting equipment under a Firm Fixed Price purchase order for the equipment shown below: Location Manufacturer Description and Hoist Capacity Shasta Dam Star Iron and Steel Gantry: 125 Ton Main, 25 Ton Aux Cyclops Iron Bridge: 17 Ton Tower Crane Shasta Power Plant Lakeside Bridge A: 125 Ton Main, 25 Ton Auxiliary Lakeside Bridge B: 125 Ton Main, 25 Ton Auxiliary General Electric Gantry: 7 Ton Tail Bay Stop Log Crane Wemco / Yale Bridge: Machine Shop 5 Ton Crane Keswick Dam Judson Pacific Gantry: 40 Ton Main Penstock Crane Judson Pacific Bridge: 7.5 Ton Main Spillway Crane Kone Fish Trap Hoist Keswick Power Plant Cyclopes Iron Bridge: 115 Ton Main, 25 Ton Auxiliary Advanced / R&M Bridge: Machine Shop 10 Ton Moffet Gantry: 11 Ton Tail Bay Stop Log Spring Creek Power Plant Star Iron and Steel Bridge: 150 Ton Main, 25 Ton Auxiliary Shepard Niles Monorail: 6 Ton Stop Log Hoist JF Carr Power Plant Star Iron and Steel Bridge: 150 Ton Main, 25 Ton Auxiliary Yale Monorail: 4 Ton Stop Log Hoist Trinity Power Plant Star Iron and Steel Bridge: 150 Ton Main, 25 Ton Auxiliary Wright Monorail: 4 Ton Stop Log Hoist Trinity Dam Ederer Bridge: 25 Ton SMC Mobile Crane Grove TMS700E 60 Ton The North American Industry Classification System (NAICS) code for this requirement is 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance which has an associated small business size standard of $12.5 million. All organizations interested in providing these services should respond to this announcement by 10:00 AM PST on Monday, January 12, 2026. Responses to this sources sought announcement shall be in writing and sent via email to Sarah Anaya, Contract Specialist at sanaya@usbr.gov. Please include notice number 140R2026Q0019 in your response. Responses should include the following information: 1. Name of organization and address including zip code, Point of Contact including phone number and email address, and the organization’s UEID number. 2. Confirmation of organization’s active System for Award (SAM) registration with expiration date. 3. Business size and classification to include any designations as Certified Small Business, HUBZone Certified Small Business Concern, Section 8(a) contractor, Service-Disabled Veteran Owned Small Business, Small Disadvantaged Business, Women Owned Small Business, Indian Small Business Economic Enterprise, or Small Business Concern. 4. Number of years of experience in this type of service. 5. Provide references for a minimum of two (2), but no more than five (5) similar requirements completed within the past five (5) years from the date of this announcement which demonstrates experience in providing all services included in this requirement. 6. Your company’s intent to submit a quote should a solicitation be issued.
-Market Research01/12/2026
THIS NOTICE OF INTENT IS NOT A REQUEST FOR QUOTES. A DETERMINATION NOT TO COMPETE THE PROPOSED PROCUREMENT BASED UPON RESPONSES TO THIS NOTICE IS SOLELY WITHIN THE DISCRETION OF THE GOVERNMENT. The Puget Sound Naval Shipyard and Intermediate Maintenance Facility (PSNS & IMF) Contracting Office (Code 400), hereby provides notice of its intent to award a sole-source firm fixed service contract to Tacoma Hydraulics, Inc. (CAGE: 762R3). The contract is expected to be awarded under FAR RFO 6.103-2(b). A Justification and Approval for Other Than Full and Open Competition has been prepared. The period of performance shall be the 25 November 2026 - 6 December 2026. INTENT TO SOLE SOURCE – Refurbishment of two Elwell Parker R334 Main Lift Cylinders. Services include all reconditioning required to restore the equipment to function as intended. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES; no solicitation or RFQ will be forthcoming. However, interested parties may identify their interest and capability to respond to this requirement no later than 28 October 2026, 0900 PST. Interested parties are encouraged to furnish information by email only with subject line stating - RESPONSE TO INTENT TO SOLE SOURCE FOR N4523A27Q5705 - ELPAR CYLINDER REPAIR A determination to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. PSNS and IMF Contracting Office (Code 400) will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) in order to be eligible for award. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Contract Specialist, Isaiah Fontenot by email at isaiah.m.fontenot.civ@us.navy.mil and Contracting Officer, Amanpreet Johal at amanpreet.s.johal2.civ@us.navy.mil. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements.
-Special Notice10/28/2026

Additional Details

Solicitation Number

14R1719Q0023

Archive Date

Aug 31, 2019

Office Address

DENVER, CO, 80225