GovChime
Notice ID: 41ddd9de05734db58c907a69086f235eSources Sought

EMERGENCY REPLACE COOLING TOWER - FCC ALLENWOOD

Archived on September 9, 2026. Original response deadline: . Full description on SAM.gov.

Description

THIS IS A SOURCES SOUGHT NOTICE. THIS NOTICE IS ISSUED FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION OR INVITATION FOR OFFERORS TO SUBMIT QUALIFICATION DOCUMENTS OR PROPOSALS. SHOULD THIS REQUIREMENT MOVE FORWARD, A SYNOPSIS OF THE PROPOSED CONTRACT ACTION WILL BE POSTED AT A LATER DATE PROVIDING INSTRUCTIONS FOR OFFERORS TO RESPOND TO THIS OPPORTUNITY.

Please only respond to this sources sought notice if you are seriously interested and if your company is capable of performing the corresponding work required.

The Federal Bureau of Prisons (FBOP), Federal Correctional Complex (FCC) Lompoc anticipates the issuance of a solicitation for the award of a firm-fixed-price construction contract for a project titled Emergency Replace Cooling Tower at FCC Allenwood located at 824 Main Access Rd, Allenwood, PA.

The Federal Bureau of Prisons (FBOP), FCC Allenwood, located at 824 Main Access Rd, Allenwood, PA, seeks to award a single contract to a qualified and licensed contractor to provide all labor, materials, and engineering services replace the cooling tower at FCC Allenwood’s Powerhouse.

1. Contractor qualified technicians to demolish and properly dispose:

a. One (1) existing three-cell Evapco AT-12-964A cooling tower.

1. Isolate and drain down existing tower.

2. Disconnect piping and perform lock-out of existing electrical.

3. Demo and dispose of all material.

2. Contractor qualified technicians to furnish and install:

a. One (1) three-cell cooling tower with slow/fast speed fans that tie into our

existing motor control buckets. The new unit shall be of similar make, model, and

capacity of those being removed.

b. Modify power and control wiring as required for use with new tower. All

controls to be tied into the Automated Logic control system.

c. Install new piping and valves outside of the building, to include new insulated

jacketing and heat tracing.

d. The cooling tower is to be installed on the existing concrete foundation. If the

existing concrete foundation and/or structural steel are not adequate for the new

tower, the contractor shall be responsible for sizing and installation/modifications

of a new foundation to accommodate the tower.

3. Contractor to perform factory authorized startup, staff training, and the following warranties:

a. Provide one-year labor and equipment warranty from time of start-up.

b. Provide five-year fan/motor drive system manufacturer warranty.

Please note that the attached Statement of Work is subject to change.  The attachments included with the solicitation will provide complete requirements for this project.  The solicitation will be posted at a later date.

Access to attachments will require an active vendor registration at SAM.gov as well as your Marketing Partner Identification Number (MPIN) associated with your SAM registration.  You will need to request access, to the controlled document(s), and receive approval prior to being able to view the files.  If you encounter problems requesting access to these documents, please refer to the Help section on SAM.gov or contact the Federal Service Desk at 866-606-8220.

The North American Industrial Classification System (NAICS) code applicable to this requirement is 238220 (Plumbing, Heating, and Air Conditioning Contractors) with a corresponding small business size standard of $19.0 million average annual receipts for the firms preceding three fiscal years. The estimated magnitude of this project lies between $1,000,000 and $5,000,000.

Interested bidders must be registered in the System for Award Management (SAM) at https://sam.gov.

The FBOP is seeking small business contractors for this project. Your business size metrics information entered in your SAM registration must be less than or equal to the small business size standard specified above to qualify as a small business. Interested small business contractors are requested to respond to this notice by adding their names to the Interested Vendors List for this posting on the SAM website at https://sam.gov. You must be logged in to your vendor account in order to access the Interested Vendors List. Please add your business name only if you are interested in submitting a bid as a Prime contractor and are capable and eligible to compete for and perform this project.

This notice is intended only for those who would be entering into a Prime contract with the FBOP for the entirety of the project. The FBOP does not award subcontracts. Subcontracts (if applicable/necessary) are the responsibility of the Prime contractor. The FBOP has no privity of contract with subcontractors.

Interested parties are also requested to complete the attached Market Research Questionnaire and return the completed document to csmith14@bop.gov.

The synopsis of proposed contract action will include further instructions for responding to this opportunity. Interested bidders are advised to continuously monitor www.sam.gov for all future updates.

Full description on SAM.gov

Overview

Agency:
Department of JusticeFEDERAL PRISON SYSTEM / BUREAU OF PRISONS
Office:FAO
Posted:August 18, 2026
NAICS:238220: Plumbing, Heating, and Air-Conditioning Contractors
Last Updated:Oct 25, 2026
First published:
Last updated on SAM.gov:
PSC:Not specified
Set-Aside:Small Business Set Aside - Total
Type:Sources Sought
Place of Performance:Allenwood, Pennsylvania, 17810

Award Overview

Possible prior contracts

Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).

Contacts

Contracting Officer

Primary Contact

Documents

Files (3)

  • 10. Drawings.pdf

    5.8 MBAdded in Sources Sought version 3Posted
    Requires SAM.gov sign-in
  • Market Research Questionnaire.pdf

    264 KBAdded in Sources Sought version 3Posted
    Download
  • 6. SOW (Approved).pdf

    158 KBAdded in Sources Sought version 3Posted
    Requires SAM.gov sign-in

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    EMERGENCY REPLACE COOLING TOWER - FCC ALLENWOOD

    Notice 41ddd9de05734db58c907a69086f235e on SAM.gov

Similar Opportunities

Title
Phase
Agency
NAICS
Set Aside
Posted
Deadline
Location

Additional Details

Solicitation Number

15B20126PR000450

Archive Date

Sep 9, 2026

Office Address

GRAND PRAIRIE, TX, 75051