GovChime

REPLACE CONTROLS FOR EXISTING SOLAR FIELD

Overview

Response deadline
2:00 PM UTC−07:00
Posted
December 28, 2020
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Agency
Department of JusticeFEDERAL PRISON SYSTEM / BUREAU OF PRISONS

Notice details

Office
FCI ENGLEWOOD
Place of performance
Littleton, CO, 80123
Last updated
Dec 4, 2025

Identifiers

Solicitation number
15B40321Q00000006
Notice ID
88cb6857bb8c48d699400f615d7f8c04

Description

FCI Englewood is seeking REPLACEMENT CONTROLS FOR AN EXISTING SOLAR FIELD: The existing solar water heating system controllers consists of a series of parabolic troughs used to heat water that feed into the FCI Englewood Domestic Hot Water system through heat exchangers. The working fluid inside the solar collectors is a 40% propylene glycol/60% water mixture, circulated through the array with a 5 HP pump. A heat exchanger inside the storage tank transfers heat energy from the array to the non-potable water inside the tank. This project shall include layout, supply, and installation of replacement master and local controllers and integration into the existing Johnson Controls Metasys DDC system while maintaining the existing instrumentation and infrastructure in place. ****Closing date extended**** THIS REQUEST CLOSE DATE HAS BEEN CHANGED TO 12/30/2020 at 2:00PM (MST). Modified to add attachments, modified to answer questions and ***ADD SITE VISIT QUESTION: Is there any possibility of a site walk to look over the existing controls and the solar array? ANSWER: A site visit has been scheduled for Tuesday December 22nd at 10 am please contact email Mr. White at jx7white@bop.gov by 12-21-2020 if you wish to attend. QUESTION: Would it be possible to re-use the existing conduit runs for signal wires or would all new conduit be needed? ANSWER: Yes, you can re-use the existing conduit. QUESTION: Is there an I/O list available? ANSWER: All information regarding Input/Output was in the SOW and attached reference materials. QUESTION: Will the selected contractor be able to access the program for the existing control system up award? ANSWER: Yes QUESTION: What historian (data storage) capacity (days/weeks/months) is required for the new system? ANSWER: Minimum of 30 days QUESTION: Is remote access to the control system and interface via cellular devices desired or prohibited? ANSWER: Remote access is prohibited.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:15B40321Q00000006
  1. Combined Synopsis
  1. 6×
    Combined SynopsisCurrentNov 19, 2020

    REPLACE CONTROLS FOR EXISTING SOLAR FIELD

    Notice 88cb6857bb8c48d699400f615d7f8c04 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

15B40321Q00000006

Archive Date

Jan 14, 2021

Office Address

LITTLETON, CO, 80123