GovChime
Notice ID: 9d990341238542caa8e445a1273fea04Award NoticeAwardedArchived

FCC Terre Haute FS Cooler Replacement FCI

Awarded on August 6, 2026. The description is published on SAM.gov: Full description on SAM.gov.

Awarded tounder 15B41826P00000175 (source: SAM.gov award notice)• $94.0K

Overview

Posted
August 7, 2026
Notice type
Award Notice
Set-aside
Small Business Set Aside - Total
NAICS
423740: Refrigeration Equipment and Supplies Merchant Wholesalers
Agency
Department of JusticeFEDERAL PRISON SYSTEM / BUREAU OF PRISONS

Notice details

Office
USP TERRE HAUTE
Place of performance
Terre Haute, Indiana, 47802
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Aug 6, 2026
Award amount (SAM.gov award notice)
$94.0K

Identifiers

Solicitation number
15B41826P00000175
Notice ID
9d990341238542caa8e445a1273fea04
Award number (PIID)
15B41826P00000175

Description

No description in the SAM.gov data feed for this notice.

Full description on SAM.gov

Award Overview

Award Number

15B41826P00000175

Award Amount (SAM.gov award notice)

$94.0K

Award Date

Aug 6, 2026

Awardee

Awardee UEI

PGHSUHK2EGL1

Awardee CAGE Code

565X1

Awardee Address

Evansville, IN 47713, UNITED STATES

Line Item Number

71

Original Solicitation

Notice ID: 9d990341238542caa8e445a1273fea04

Posted Date: Aug 7, 2026

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (3)

  • Questions from vendors.docx

    17 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • RFQ 15B41826Q00000029.pdf

    258 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • Combined Synopsis Solicitation FS Cooler Parts.docx

    15 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchived

    FCC Terre Haute FS Cooler Replacement FCI

    Notice ab93312146b140ebbb88ccb638608ed1 on SAM.gov

  2. 5
    Version 5Award NoticeArchivedCurrent

    Type changed from Combined Synopsis/Solicitation to Award Notice

    FCC Terre Haute FS Cooler Replacement FCI

    Notice 9d990341238542caa8e445a1273fea04 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
44%
Combined Synopsis10/20/2026
Page 2 of 2 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide brand name or Equal Leer Combo Indoor Walk-in Coolers and Freezer for the Captain James A. Lovell Federal Health, North Chicago, IL 60064-3048. Salient Characteristics Walk-In Coolers And Freezer: Dimensions And Basic Description Leer Combo Indoor Walk-in: 44' 6 3/4" x 31' 7" x 8' 6" Freezer (-10°) (5 1/2" Wood Rail Polyurethane) 15' 3" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 14' 1 7/8" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 15' 1 7/8" x 31' 7" x 8' 6" ** Freezer (-10°) panels 24" x 26.5"X 20.75" x 8'6 COLUMN WRAP (3 SIDED) 24" X 26" X 20.75" X 8'6 COLUMN WRAP (3 SIDED) Lag down Ceiling with Ceiling Hangers Included U.L. Flame Spread Rated, U.L. Electric Listed - NSF Listed 2009 EISA COMPLIANT Floor(s) Freezer (-10°) 24 Ga Stainless Steel 5 1/4" SUPER Floor with ADT Overlay Cooler (35°) Cooler (35°) Floorless with Wood Screed and Cove Molding Finishes 26 Ga Stucco White Interior Wall and Ceiling 26 Ga Stucco White Exterior Wall 26 Ga Stucco Galv Exterior Ceiling and Floor Doors (HD1) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD2) Door Freezer (-10°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD3) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall Accessories INCLUDES UL Labels Vapor Proof Light Kason 1277 Hinge Heated Vent Dial Flush Thermometer Exterior Ramp(36" Depth) Heated Frame Heated Plug Inside Release Push Handle 1092 Door Closer Standard Switch Strike Brushed Chrome Support Wheel REFRIG - SYSTEM 1 CCH0100LCBCZA0000 CU208/3 LT10HP HFC CP SCL STD FS PT Refrigerant Type : R448A REFRIG - SYSTEM 1 CEM0300BS6EMAB0000 UC208-230/1 EL 2F HFC STD 2EC ST Refrigerant Type : R448A REFRIG WARRANTY SYSTEM 1 4 YR EXT.COMP WARRANTY 10 HP SCROLL REFRIG - SYSTEM 2 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 2 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A Intelligent WARRANTY SYSTEM 2 4 YR EXT.COMP WARRANTY 3 HP SCROLL REFRIG - SYSTEM 3 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 3 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A REFRIG IG WARRANTY SYSTEM 3 4 YR EXT.COMP WARRANTY 3 HP SCROLL Submit responses to the Contracting Officer, Jennifer Mead, at Jennifer.Mead@va.gov no later than 10:00 a.m. (Central Standard Time), 6 October 2026. RFQ - 36C25226Q0721 shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. Each submittal shall also include the following business information: SAM UEI Organization Name Organization Address Point of Contact (including name, title, addresses, telephone number, fax number and Email address) Business size Socio-economic status ( IF SDVOSB or VOSB provide SDVOSB or VOSB CVE verification) Open Market or GSA/ FSS The NAICS Code 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
44%
Market Research10/06/2026
Page 2 of 2 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide brand name or Equal Leer Combo Indoor Walk-in Coolers and Freezer for the Captain James A. Lovell Federal Health, North Chicago, IL 60064-3048. Salient Characteristics Walk-In Coolers And Freezer: Dimensions And Basic Description Leer Combo Indoor Walk-in: 44' 6 3/4" x 31' 7" x 8' 6" Freezer (-10°) (5 1/2" Wood Rail Polyurethane) 15' 3" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 14' 1 7/8" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 15' 1 7/8" x 31' 7" x 8' 6" ** Freezer (-10°) panels 24" x 26.5"X 20.75" x 8'6 COLUMN WRAP (3 SIDED) 24" X 26" X 20.75" X 8'6 COLUMN WRAP (3 SIDED) Lag down Ceiling with Ceiling Hangers Included U.L. Flame Spread Rated, U.L. Electric Listed - NSF Listed 2009 EISA COMPLIANT Floor(s) Freezer (-10°) 24 Ga Stainless Steel 5 1/4" SUPER Floor with ADT Overlay Cooler (35°) Cooler (35°) Floorless with Wood Screed and Cove Molding Finishes 26 Ga Stucco White Interior Wall and Ceiling 26 Ga Stucco White Exterior Wall 26 Ga Stucco Galv Exterior Ceiling and Floor Doors (HD1) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD2) Door Freezer (-10°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD3) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall Accessories INCLUDES UL Labels Vapor Proof Light Kason 1277 Hinge Heated Vent Dial Flush Thermometer Exterior Ramp(36" Depth) Heated Frame Heated Plug Inside Release Push Handle 1092 Door Closer Standard Switch Strike Brushed Chrome Support Wheel REFRIG - SYSTEM 1 CCH0100LCBCZA0000 CU208/3 LT10HP HFC CP SCL STD FS PT Refrigerant Type : R448A REFRIG - SYSTEM 1 CEM0300BS6EMAB0000 UC208-230/1 EL 2F HFC STD 2EC ST Refrigerant Type : R448A REFRIG WARRANTY SYSTEM 1 4 YR EXT.COMP WARRANTY 10 HP SCROLL REFRIG - SYSTEM 2 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 2 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A Intelligent WARRANTY SYSTEM 2 4 YR EXT.COMP WARRANTY 3 HP SCROLL REFRIG - SYSTEM 3 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 3 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A REFRIG IG WARRANTY SYSTEM 3 4 YR EXT.COMP WARRANTY 3 HP SCROLL Submit responses to the Contracting Officer, Jennifer Mead, at Jennifer.Mead@va.gov no later than 10:00 a.m. (Central Standard Time), 6 October 2026. RFQ - 36C25226Q0721 shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. Each submittal shall also include the following business information: SAM UEI Organization Name Organization Address Point of Contact (including name, title, addresses, telephone number, fax number and Email address) Business size Socio-economic status ( IF SDVOSB or VOSB provide SDVOSB or VOSB CVE verification) Open Market or GSA/ FSS The NAICS Code 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
44%
Market Research10/06/2026
Spot Cooler Parts
44%
Combined Synopsis07/20/2026
Walk-In Cooler
40%
Combined Synopsis01/28/2026

Additional Details

Solicitation Number

15B41826P00000175

Archive Date

Aug 21, 2026

Office Address

TERRE HAUTE, IN, 47802