Notice ID: 41e7e402216d4047b9baf2b82dfd8e68Solicitation
Repair Power Plant Boilers- FCI La Tuna
Archived on September 19, 2024. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:00 AM UTC−07:00
- Posted
- September 4, 2024
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of JusticeFEDERAL PRISON SYSTEM / BUREAU OF PRISONS
Notice details
- Office
- FAO
- Place of performance
- Anthony, TX, 79821
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- 15BFA024B00000019
- Notice ID
- 41e7e402216d4047b9baf2b82dfd8e68
Description
9/4/2024- Bid Abstract added - Amendment 00001- Incorporate Pre-Bid Meeting Minutes and responses to received questions. Solicitation The Federal Bureau of Prisons (FBOP) is issuing solicitation 15BFA024B00000019 for the award of a firm-fixed-price construction contract for a project entitled Repair Power Plant Boilers at the Federal Medical Center (FCI LA TUNA), located in Anthony, Texas. FCI LA TUNA is a federal correctional facility located at 8500 Doniphan Drive, Anthony, TX 79821. The project consists of the following: 1. The work site includes the Main Power Plant to FCI La Tuna, which is a United States federal prison for male inmates located in Anthony, Texas. The requirement includes the removal of existing and install new of following for two boilers: boiler burners, gas lines, wiring, and control system. See the Statement of Work/Specifications attachment included with the solicitation posting for the complete requirements of the work. The performance period for the project will be 260 Calendar Days from issuance of the notice to proceed. The NAICS code for this requirement is 238220 with a corresponding small business size standard of $19 million. Pursuant to Federal Acquisition Regulation (FAR) 36.204, the estimated magnitude of the project lies between $250,000.00 and $500,000.00.. (NOTE: This range is one of 8 available ranges from FAR 36.204 and is not meant to imply that the project has necessarily been estimated/budgeted to the maximum of the selected range. It merely conveys that the estimate/budget lies somewhere within that range.) The solicitation will be distributed solely through the Contract Opportunity website at https://www.sam.gov. Hard copies of the solicitation will not be made available. The website provides download instructions. The "Sensitive /Secure package Upload" option will be selected for this procurement. All secure/locked documents uploaded, to include the solicitation, will require an active SAM vendor registration to obtain access. In addition, only those vendors who have been issued a valid Marketing Partner Identification Number (MPIN) from www.sam.gov will be granted access. If your firm does not have the NAICS code listed in www.sam.gov required for this solicitation, an email may be forwarded to your firm requesting an explanation as to why your firm should be granted access. If you encounter problems accessing these documents, please contact the Federal Service Desk at 866-606-8220. All future information about this solicitation, including any amendments, will also be distributed solely through this website. Interested parties are responsible for continuously monitoring this website to ensure that they have the most recent information about this proposed contract action. IMPORTANT: Any contractor interested in obtaining a contract award with the Federal Bureau of Prisons must be registered in https://www.sam.gov. In order to qualify for award, your business size metrics information entered in your www.sam.gov SAM registration must be less than or equal to the size standard specified above. Each bidder's www.sam.gov registration will be reviewed by the Government to confirm that your business size meets the small business size standard requirement. All bidders are urged to double check their www.sam.gov registration and update as necessary, including the size metrics information. This is a 100 percent small business set-aside. You must be registered in www.sam.gov as a small business for the applicable NAICS code (see FAR provision 52.219-1 in the Representations & Certifications section of your www.sam.gov registration).
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
15BFA024B00000019- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Pre-SolicitationJul 8, 2024
Repair Power Plant Boilers- FCI La Tuna- Pre-Solicitation Notice
- 3×SolicitationCurrentJul 25, 2024
Repair Power Plant Boilers- FCI La Tuna
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Replace powerhoues hot water tanks at FCI Marion in accordance with the statement of work. A site visit will be held November 10, 2026 at 9:00 AM CST at the powerhouse located at FCI Marion 4500 Prison Road Marion, IL 62959. Vendors who plan to attend the site visit must submit the attached Criminal History Check Form to John Jordan, Facilities Manager by 12:00 PM CST by Thursday, November 5, 2026 for clearance. Email: Jxjojordan@bop.gov. Phone: 618-964-2098. All questions are due to Tammie Johnson, Contracting Officer by COB November 17, 2026. Email: t8johnson@bop.gov. | - | Pre-Solicitation | 11/30/2026 |
Replace powerhouse hot water tanks in accordance with the SOW. A site visit will be held November 10, 2026 at 9:00 AM CST at the powerhouse located at FCI Marion 4500 Prison Road Marion, IL 62959. Vendors who plan to attend the site visit must submit the attached Criminal History Check Form to John Jordan, Facilities Manager by 12:00 PM CST by Thursday, November 5, 2026 for clearance. Email: Jxjojordan@bop.gov. Phone: 618-964-2098. All questions are due to Tammie Johnson, Contracting Officer by COB November 17, 2026. Email: t8johnson@bop.gov. | - | Solicitation | 11/30/2026 |
| - | Awarded | Open | |
| - | Sole Source / J&A | Open | |
THIS IS A SOURCES SOUGHT NOTICE FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION, REQUEST FOR PROPOSAL (RFP), OR INVITATION FOR BID (IFB). A SYNOPSIS OF PROPOSED CONTRACT ACTION WILL BE POSTED AT A LATER DATE WHICH WILL PROVIDE INSTRUCTIONS FOR BIDDERS TO RESPOND TO THIS OPPORTUNITY.PLEASE DO NOT RESPOND TO THIS NOTICE IF YOU ARE NOT SERIOUSLY INTERESTED AND IF YOU DO NOT PERFORM THIS REQUIREMENT. IT WILL DELAY THE POSTING OF THE SOLICITATION DUE TO FURTHER MARKET RESEARCH THAT WILL BE REQUIRED. The Federal Bureau of Prisons (FBOP) is conducting market research to determine the availability and capability of qualified contractors to perform a design-build construction project at FCI El Reno, Oklahoma. Responses will be used to assist in determining the appropriate acquisition strategy and potential socioeconomic set-aside determination. The Government anticipates issuing a solicitation following completion of market research. Responses must be received no later than 2:00 PM Central Time (CT) on November 17, 2026. Project Location: FCI El Reno, 4205 Highway 66 West, El Reno, OK 73036 NAICS Code: 238220 - Plumbing, Heating, and Air Conditioning Contractors; Small Business Size Standard: $19.0 Million Project Description The Federal Bureau of Prisons anticipates issuing a Firm-Fixed-Price Design-Build Construction Contract for the replacement and modernization of HVAC systems serving five (5) inmate housing facilities at FCI El Reno. The project consists of providing all design, engineering, labor, supervision, materials, equipment, testing, commissioning, and incidental work required to replace aging direct expansion (DX) cooling systems with a modern chilled-water system serving Housing Units A, B, C, D, and the Special Housing Unit (SHU). Work includes removal and disposal of ten (10) existing DX condensing units and associated equipment; design and installation of ten (10) new air-cooled packaged chillers; installation of ten (10) new chilled-water cooling coils; construction of five (5) chiller equipment pads and five (5) temporary chiller landing pads; installation of chilled-water piping systems; electrical distribution modifications and upgrades; installation of five (5) temporary cooling connection stations and five (5) temporary shore-power connection stations; BAS/DDC controls integration; contractor-provided temporary cooling services during phased construction; and all testing, adjusting, balancing (TAB), commissioning, startup, training, and closeout activities. Work will be performed within an occupied, secure federal correctional institution and will require strict compliance with institutional security requirements. Submission Instructions Interested contractors shall complete the attached questionnaire and submit it via email to Jose Dominguez at jdominguez@bop.gov. Responses must be received no later than 2:00 PM Central Time (CT) on November 17, 2026. Vendors are also encouraged to add their name to the Interested Vendors List in SAM.gov. | - | Market Research | 11/17/2026 |
Additional Details
Solicitation Number
15BFA024B00000019
Archive Date
Sep 19, 2024
Office Address