6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
Cancelled on SAM.gov (notice posted August 10, 2026). Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 8:00 AM PDT
- Posted
- August 10, 2026
- Notice type
- Combined Synopsis/Solicitation
- NAICS
- 339113: Surgical Appliance and Supplies Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262)
- Place of performance
- VA San Diego Healthcare System Jennifer Moreno Medical Center
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C26226Q0944
- Notice ID
- d690d0e6e88b4394b0fe6fcf01dd8732
Description
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (12)
- Download
D.10 SALIENT CHARACTERISTICS SHEET - VASD CEILING PATIENT LIFTS.pdf
251 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.9 VASD INFECTION RISK CONTROL ASSESSMENT - VASD CEILING PATIENT LIFTS.pdf
358 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.8 VASD 6 MONTH ASBESTOS REINSPECTION - VASD CEILING PATIENT LIFTS.pdf
1.7 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.7 VASD 3-YEAR ASBESTOS INSPECTION 12.06.2023 PART 4 OF 4 - VASD CEILING PATIENT LIFTS.pdf
16 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.6 VASD 3-YEAR ASBESTOS INSPECTION 12.06.2023 PART 3 OF 4 - VASD CEILING PATIENT LIFTS.pdf
20 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.5 VASD 3-YEAR ASBESTOS INSPECTION 12.06.2023 PART 2 OF 4 - VASD CEILING PATIENT LIFTS.pdf
20 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.4 VASD 3-YEAR ASBESTOS INSPECTION 12.06.2023 PART 1 OF 4 - VASD CEILING PATIENT LIFTS.pdf
19 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.3 VASD MAP BLDG 1 AND 11 - VASD CEILING PATIENT LIFTS.pdf
830 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.2 VASD FLOOR PLANS - VASD CEILING PATIENT LIFTS.pdf
67 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
D.1 WAGE DETERMINATION RATE SCA 2015-5635 REV. 30.pdf
131 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
S02 RFQ 36C26226Q09VASD Ceiling Mounted Patient Lifts Including Installation and Removal of Existing Ceiling Lifts.pdf
866 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
36C26226Q0944.docx
22 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
- 2Version 2Combined Synopsis/SolicitationCancelledArchivedCurrent
6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
- 5Version 5Award NoticeArchived
Type changed from Combined Synopsis/Solicitation to Award Notice
Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
Other notices for this solicitation
- Combined SynopsisRelated noticeJul 15, 2026
6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
- Combined SynopsisRelated noticeJul 15, 2026
6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
- Combined SynopsisCancelled on SAM.govRelated noticeAug 10, 2026
6530--VA San Diego Ceiling Mounted Patient Lifts with Installation and Removal of Existing Patient Lifts
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Patient safety lifts The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts. All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Salient characteristics (QTY 21) Patient Safety Lifts All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021 xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better 4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1) | 78% | Market Research | 09/10/2026 |
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) San Diego Healthcare System is seeking sources capable of providing medical grade bed covers equivalent to Stryker IsoTour. The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Statement of Work: Bed Covers Introduction: The purpose of this Statement of Work (SOW) is to establish a firm fixed-price Blanket Purchase Agreement (BPA) to procure bed covers equivalent to Stryker IsoTour covers for base plus four option years. This requirement is intended to streamline the acquisition of these specific components to ensure the continued operational readiness of medical equipment. Scope of Work: The contractor shall provide the necessary parts as specified in the technical requirements section of this SOW. This is a BPA intended for recurring requirements; the government will issue individual delivery orders against this agreement as need arises during the period of performance. Period of Performance: The BPA shall remain in effect for a base period of one (1) year from the date of establishment, with four (4) optional one-year renewal terms, subject to government funding and performance evaluation. Base: 1/1/2027 12/31/2027 Option Year 1 (OY1): 1/1/2028 12/31/2028 Option Year 2 (OY2): 1/1/2029 12/31/2029 Option Year 3 (OY3): 1/1/2030 12/31/2030 Option Year 4 (OY4): 1/1/2031 12/31/2031 Deliverables: The chart below is estimated quantities for base and all option years; quantities are not a contractual statement of precise quantities that the Government will order. The quantities given are estimated only, and no guarantee of their accuracy is either given or implied. The Government will only pay for quantities that are actually ordered per each delivery order and for which the services are fulfilled. Item Description Base Estimated Quantity OY1 Estimated Quantity OY2 Estimated Quantity OY3 Estimated Quantity OY4 Estimated Quantity Top Covers Equivalent to Stryker IsoTour 63 63 251 63 63 Bottom Covers Equivalent to Stryker IsoTour 63 63 251 63 63 Salient Characteristics: NOTE: All parts must be new, unused, and in their original manufacturer packaging. No refurbished or third-party alternative parts will be accepted. VAAR 852.212-71 Gray Market and Counterfeit Items clause applies on this acquisition. No remanufacturers or gray market items will be acceptable. The contractor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other signed documents from the OEM. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contains the signature of an authorized official for the manufacturer. If the offerors fail to provide a signed letter from the OEM (unless the contractor is the OEM), your quote will not be evaluated for award. If you are the OEM, state so in your quote response. Bed covers shall not void or adversely affect any existing manufacturer warranties applicable to the Stryker Model 2872 IsoTour Gel Support Surface. The contractor shall provide documentation demonstrating compatibility with the OEM mattress system and that use of the replacement cover will not negatively impact warranty coverage. Bed covers shall be fully compatible with the Stryker Model 2872 IsoTour Gel Support Surface and shall fit the existing mattress without modification to the mattress or stretcher system. Bed covers must be medical grade. Bed covers must be fluid-resistant or fluid proof. Bed covers shall permit normal use of all existing mattress attachment mechanisms. Top covers shall be designed to fit IsoTour Gel Support Surface mattresses measuring 78.75" (200 cm) L x 35.5" (90.2 cm) W x and 9.5" (24.1 cm) H. Bottom covers shall be designed to fit mattresses measuring 84.25 (213.9 cm) in L x 35.5" (90.2 cm) W and shall securely interface with the corresponding top cover to maintain intended mattress function and patient support. Schedule: Deliverables shall be provided upon the issuance of a BPA delivery order. The contractor shall provide the following: Order Acknowledgement: Within two (2) business days of receiving the order. Shipping Notification: Including tracking numbers and expected delivery dates. The following delivery addresses are applicable, and the vendor will be instructed where to deliver order. Place of Performance: The contractor will be instructed where to deliver each delivery order. VA San Diego Healthcare System 3350 La Jolla Village Drive San Diego, CA 92161 Delivery hours 7am-3pm M-F, Federal holidays excepted VA Off-Site Warehouse 9755 Birch Canyon Pl, Ste 100 San Diego, CA 92126 Delivery hours: 7am-3pm M-F, Federal holidays excepted Federal Holidays: New Year s Day January 1 Martin Luther King s Birthday 3rd Monday in January Presidents Day 3rd Monday in February Memorial Day Last Monday in May Juneteenth Day June 19 Independence Day July 4 Labor Day 1st Monday in September Columbus Day 2nd Monday in October Veterans Day November 11 Thanksgiving Day 4th Thursday in November Christmas Day December 25th The President of the United States of America may declare additional days as a Federal holiday, and if so, this holiday will automatically be added to the list above. When a holiday falls on a Sunday, the following Monday shall be observed as a Federal holiday. When a holiday falls on a Saturday, the preceding Friday shall be observed as a Federal Holiday. Quality Assurance and Inspection: The government reserves the right to inspect all delivered items. Any parts that arrive damaged, incorrect, or fail to meet the OEM specifications defined in Section 3.0 will be rejected and returned at the vendor's expense. Replacement parts must be provided within ten (10) business days of the rejection notice. Special Instructions Invoicing: Invoices shall be submitted electronically via Tungsten or the designated government payment system, referencing the specific purchase order numbers, which shall be provided on each delivery order. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, November 20, 2026, by 10 AM Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. | 77% | Market Research | 11/20/2026 |
This amendment incorporates GSAM Clause 552.238-120 Economic Price Adjustment – Federal Supply Schedule Contracts (Tailored) (Sep 2024), updates Responsibility Evaluation dated October 2025, and updates the Signature Authority form dated August 2025. | 75% | Combined Synopsis | 03/26/2023 |
See document 36C24126Q0535_1. | 69% | Market Research | 09/07/2026 |
Patient Lifts & Slings for In Home Use This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10G27R0002 is issued as a request for proposal (RFP) for Patient Lifts and Slings (for in home use) as a uniform preferred product for Veterans, service members, and their families, who have earned through their military service to the United States. VHA accomplishes its mission by delivering patient-centered, personalized services that help Veterans readjust to civilian life and enhance their well-being. The Department of Veteran Affairs (VA) Veteran Health Administration (VHA), Prosthetic and Sensory Aids Service (PSAS) has a need for Hydraulic Patient Lifts and Battery Powered Patient Lifts with Slings which are assistive devices that allows ability for caregivers to transfer Veterans between a bed, a chair or other similar resting places. The purpose of this acquisition is to establish a supply source that will provide the contracted items to be utilized by Veterans Affairs Medical Centers (VAMCs). The objective is to ensure availability and consistency of products for nationwide usage and to obtain volume-based, standardized pricing. Standardization provides Veterans with high-quality continuity of healthcare and gives the VA concentrated buying power. This standardization initiative is in accordance with VHA Directive 1761.1. The Government seeks to establish an Indefinite Delivery Indefinite Quantity (IDIQ) contract(s) with a period of performance of one (1) base year and four (4), one (1) year options. The requirement is solicited as a partial set aside for small business concerns for the Battery Powered Patient Lifts portion of the acquisition and Full and Open competition for the Hydraulic Patient Lifts portion of the acquisition. The associated North American Industry Classification System (NAICS) code for the procurement of these items is 339113 with a small business size standard of 800 employees. Please identify your business size in your response based upon this standard. The government will only establish award(s) with the Offeror(s) that meets all requirements of the solicitation. The award(s) resulting from this solicitation will be made based on the best overall proposal that is determined to be the most beneficial to the Government (i.e., best value). Place of Performance: Multiple locations throughout the continental US, Hawaii and all US Territories; delivery location(s) will be defined per each order. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. All vendors must be registered in the System for Award Management (SAM) database https://sam.gov. This acquisition is being conducted in accordance with the procedures in Federal Acquisition Regulation (FAR) Part 12 Acquisition of Commercial Products and Commercial Services in conjunction with FAR Part 15 Contracting by Negotiation, FAR Part 16.504 Indefinite-quantity Contracts, and FAR Part 16.505 Ordering. Proposals must be submitted in accordance with the instructions provided under Federal Acquisition Regulation (FAR) 52.212-1 Instructions to Offerors Commercial Items. The proposal must be submitted no later than December 15, 2026, 12 PM EST unless this date is changed via a formal solicitation amendment. The contractor shall submit an electronic (email) copy of the proposal to both Noel Echevarria, Contract Specialist at Noel.Echevarria@va.gov and Brian Love, Contracting Officer at Brian.Love@va.gov. The Government is not responsible for confirming receipt. Any proposal received after the specified date and time will be unresponsive and shall receive no further consideration. In accordance with FAR 52.212-1(c), Offerors are responsible for submitting offers and any modifications or revisions to the Government office designated in the solicitation by the time specified in the solicitation. These e-mail addresses identified for the Contract Specialist and Contracting Officer are the Government office designated in the solicitation as defined in FAR 52.212-1(c)(1) for timely receipt of proposals. Exceptions for late receipt of electronic submissions are specifically outlined in FAR 52.212-1(c)(2). | 68% | Solicitation | 12/15/2026 |
Additional Details
Solicitation Number
36C26226Q0944
Archive Date
Sep 11, 2026
Office Address