Cummins Generator Diesel Genset
Awarded on December 3, 2025. Full description on SAM.gov.
Overview
- Posted
- December 5, 2025
- Notice type
- Award Notice
- Set-aside
- No Set aside used
- NAICS
- 335312: Motor and Generator Manufacturing
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- AIR EDUCATION AND TRAINING COMMAND.FA3029 71 FTW CVC
- Place of performance
- Enid, Oklahoma, 73705
- PSC
- 6115: GENERATORS AND GENERATOR SETS, ELECTRICAL
- Last updated
- Aug 21, 2026
- Award date
- Dec 3, 2025
- Award amount (SAM.gov award notice)
- $57.8K
Identifiers
- Solicitation number
- 207084-BK
- Notice ID
- 9d91eeb957724ebea9dbab6fe899bfdd
- Award number (PIID)
- 20242
Description
ASRC Federal Field LLC, (AFFS) on behalf of the government would like to propose a synopsis/solicitation for a Firm Fix Price commercial item.
AFFS intends to utilize this Request for Quotation (RFQ), under solicitation number 207084-BK, to award a FFP Low Cost/Technically Acceptable contract.
The Description of generator is list as follows:
1 EA: C60D6C Diesel Genset, 60Hz, 60kW
H268-2 Extension - Oil Drain
F253-2 Larger Battery Rack
A322-2 Packing - Skid, Poly Bag
L050-2 Literature - English
L028-2 Genset Warranty - 2 Years Base
H706-2 Engine Oil
E154-2 Coolant Heater, Extreme Cold Ambient
H487-2 Engine Oil Heater - 120 Volts AC, Single Phase
H669-2 Engine Coolant - 50% Antifreeze, 50% Water Mixture
E089-2 Extension - Coolant Drain
H527-2 Warning - Low Coolant Level
E125-2 Engine Cooling - Radiator, High Ambient Air Temperature, Ship Fitted
BB89-2 Battery Charger - 6 Amp, Regulated
A333-2 Battery Charging Alternator
D041-2 Engine Air Cleaner - Normal Duty
A422-2 Engine Starter - 12 Volt DC Motor
A366-2 Engine Governor - Electronic, Isochronous
3840 Circuit Breaker or Terminal Box (Position C) - None
3250 Circuit Breaker or Terminal Box (Position B) - None
KX30-2 Circuit Breaker, Location A, 125A - 400A, 3P, LSI, 600 Volts AC, 100%, UL
KV03-2 Load Connection - Single
H536-2 Control Display Language - English
K796-2 Stop Switch - Emergency
H012-2 Gauge - Oil Pressure
H700-2 PowerCommand 1.1 Controller
H609-2 Control Mounting - Left Facing
C318-2 Switch - Fuel Tank, Rupture Basin
C314-2 5 Gallon Lockable Spill Containment Fuel Fill Box
C312-2 Mechanical Fuel Gauge
C310-2 Low Fuel Level Switch, 40%
C127-2 Fuel Water Separator
C303-2 Fuel Tank - Regional, Dual Wall, Sub Base, 48 Hour Minimum
F179-2 Skidbase - Housing Ready
F252-2 Enclosure - Wind Load 180 MPH, ASCE7-10
P176-2 Enclosure Color - Green, Aluminum
F231-2 Aluminum Sound Attenuated Level 1 Enclosure, with Exhaust System
BB87-2 Alternator - 60Hz, Reconnect, Full Output, 105C, 40C Ambient, Increased
Motor Starting (IMS)
R098-2 Voltage - 120/208, 3 Phase, Wye, 4 Wire
B240-2 Exciter/Reg - Torque Match
L193-2 NFPA 110 Type 10 Level 1 Capable
L090-2 Listing - UL 2200
L169-2 Emission Certification, EPA, Tier 3, NSPS CI Stationary Emergency
A331-2 Duty Rating - Standby Power (ESP)
Install-US-Stat U.S. EPA, Stationary Emergency Application
1 EA: CBLC, Bypass Transfer Switch-Power Command:
150A/225A/260/300/400/600A 1 $17,845.41
A050-7 Packing-Wooden Crate
G012-7 Transfer Switch Warranty - 2 Year Comprehensive
M076-7 Standard Customer I/O
M033-7 Genset Starting Battery-12VDC
R021-7 Voltage-208 Volts AC
C109-7 PC80 Control
A044-7 Frequency-60 Hz
A078-7 Transfer Mode-Delayed Transition
A091-7 System - 3 Phase, 4-Wire (Solid or Switched Neutral)
A029-7 Poles-4
B002-7 Cabinet-Type 3R
A035-7 Application-Utility to Genset
A046-7 Listing-UL 1008/CSA Certification
Delivery charges will need to be included in quote.
All interest offerors will need to be sent via email to betty.kliewer.ctr@us.af.mil NLT 11/11/25 at 11:00AM CST. No late entries will be excepted.
Attached are forms that will need to be completed before an award will be made.
Award Overview
Award Number
20242
Award Amount (SAM.gov award notice)
$57.8K
Award Date
Dec 3, 2025
Awardee
Awardee UEI
DTSXKA2BGMD9
Awardee CAGE Code
15434
Awardee Address
Columbus, IN 47201, UNITED STATES
Original Solicitation
Notice ID: 9d91eeb957724ebea9dbab6fe899bfdd
Posted Date: Dec 5, 2025
Original Response Deadline: Not specified
Contract Details
Contract data not yet available
Contract details typically appear within 2-4 weeks after award; DoD awards are published about 90 days after signature.
Contacts
Contracting Officer
Primary Contact
Documents
Showing 3 of 3 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Combined Synopsis/Solicitation | DEPT OF THE AIR FORCE | Dec 5, 2025 | 82.26 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE AIR FORCE | Dec 5, 2025 | 290.01 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE AIR FORCE | Dec 5, 2025 | 371.14 KB |
Lifecycle
207084-BK- Combined Synopsis
- Awarded
This opportunity has been awarded.
- Combined SynopsisOct 29, 2025
Cummins Generator Diesel Genset
- AwardedCurrentDec 5, 2025
Cummins Generator Diesel Genset
Similar Opportunities
Additional Details
Solicitation Number
207084-BK
Archive Date
Dec 18, 2025
Office Address