GovChime
Notice ID: 283c54a2d83c41dab940d945ea786f0cSolicitation

Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation

Active, responses due . Full description on SAM.gov.

Description

The US Army Corps of Engineers, Walla Walla District is seeking sources to provide personnel, materials, supplies, equipment, transportation, supervision and other items and services for the following: Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation. This project involves pickup, blasting, weld inspection, weld repair (if needed), painting and delivery of twelve draft tube bulkheads.

Full description on SAM.gov

Overview

Agency:
Department of WarDepartment of the Army
Office:US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION NORTHWESTERN.ENDIST WALLA WALLA.US ARMY ENGINEER DISTRICT WALLA WAL
Posted:October 16, 2026
NAICS:332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
Last Updated:Oct 21, 2026
First published:
Last updated on SAM.gov:
PSC:J056: MAINT/REPAIR/REBUILD OF EQUIPMENT- CONSTRUCTION AND BUILDING MATERIALS
Set-Aside:Small Business Set Aside - Total
Type:Solicitation
Place of Performance:Not specified

Award Overview

Possible prior contracts

Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).

Contacts

Contracting Officer

Primary Contact

Documents

Files (6)

  • Solicitation - W912EF27QA002.pdf

    3.2 MBAdded in Solicitation version 3Posted
    Download
  • 27QA002_PWS_DWA Skeleton Bay Draft Tube Bulkhead Rehabilitation.pdf

    338 KBAdded in Solicitation version 3Posted
    Download
  • Drawings.pdf

    1.7 MBAdded in Solicitation version 3Posted
    Download
  • Supplemental Drawings.pdf

    3.1 MBAdded in Solicitation version 3Posted
    Download
  • DWA Skeleton Bay Draft Tube Bulkhead JA Fully Signed 1_Redacted.pdf

    134 KBAdded in Solicitation version 3Posted
    Download
  • Sources Sought - DWA Unit 4 Bulkhead Rehab.pdf

    474 KBAdded in Sources Sought version 2Posted
    Download

Lifecycle

  1. 1
    Version 1Sources Sought

    Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation

    Notice 019cbe7c51934cbd87f35dc4e9386a1f on SAM.gov

  2. 2
    Version 2Solicitation

    Type changed from Sources Sought to Solicitation

    Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation

    Notice f659d97d59054813871cdc69e16f80c0 on SAM.gov

  3. 3
    Version 3SolicitationCurrent

    Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation

    Notice 283c54a2d83c41dab940d945ea786f0c on SAM.gov

Similar Opportunities

Title
Phase
Agency
NAICS
Set Aside
Posted
Deadline
Location
Salient Characteristics: Thermion 71000-4.8 VS Feeder Assembly Part Description: 71000-4.8 VS Feeder Assembly 4.8 with VS Technology With Lubricating System Manufacturer: Thermion Associated System: Precision Arc 4.8 Twin Wire Arc Spray System 1. General Overview The Thermion 71000-4.8 VS Feeder Assembly is a core component of the Precision Arc 4.8 high-production twin wire metalizing system. It is specifically designed to feed large-diameter spray wires (such as zinc, aluminum, and zinc/aluminum alloys) smoothly and consistently in ultra-high production, industrial, and field environments. 2. Essential Physical and Design Characteristics ? Modular Construction: Features a in. plug-and-play in. factory-built design, allowing for quick, toolless connections. Each fitting is uniquely keyed to eliminate connection errors. ? Detachable and Portable: The feeder can be detached from its standard cart mount, making it suitable for use in highly confined spaces and small entrance areas(down to 24 inches). ? Heavy-Duty Components: Constructed with heavy-duty, high-temperature machine components designed to withstand harsh shop or field environments.? Ergonomics and Safety: Includes an exclusive ergonomic handle design to reduce operator fatigue and a non-latching trigger that acts as a dead-man switch for instant emergency shutdown. 3. Essential Functional and Performance Characteristics ? Wire Compatibility: Capable of running 3/16 in. (4.8 mm) diameter spray wires, yielding extremely high deposition rates (e.g., up to 190 lbs./hr. for Zinc). Change-over kits can adapt the system for other sizes like 1/8 in., 3/32 in., 2mm, or 1/16 in.. ? VS Technology (Arc Voltage Drive / Variable Speed): Utilizes automated wire feed control technology to automatically adjust wire feed speed, maintain a perfect arc, eliminate arc shorting, and prevent coating defects caused by sputtering. ? Lubricating System / Friction Reduction: Equipped with advanced, long-life wire drive assemblies featuring sealed roller bearings and roller bearing inlet guides. This low-friction mechanism mitigates drag on the wires as they enter the feeder, ensuring a smooth, non-slip feed without dry-friction binding. ?Integrated Wire Straighteners: Heavy-duty wire straighteners are built into the drive assembly. These self-adjusting mechanisms remove the helix or kinks from spooled wire, ensuring flawless delivery to the spray head. ? Remote Control Accessibility: Features remote amperage and voltage meters with integrated control mechanisms located directly at the feeder, allowing operators to make adjustments without returning to the main power supply. 4. System Compatibility and Operating Requirements ? Power Supply: Designed to integrate with a 650 Amp, 100% duty cycle power supply (such as the Thermion DIM-650). ? Control Box Compatibility: Pairs with Thermions modular control boxes (e.g.,71097-ASSY). ? Air Consumption: Requires 90-110 psi at 60 cfm (using a 1/2 in. IPS/NPT connection) for optimal atomization and functionality.
Combined Synopsis332812Total Small Business Set-Aside08/05/202608/13/2026-
Commercial Laser Engraver
Combined Synopsis332812Total Small Business Set-Aside03/18/202603/25/2026-
Centrifugal Filtration System
Combined Synopsis332812Total Small Business Set-Aside02/19/202602/26/2026-
The purpose of this Amendment is to answer RFIs and attach additional drawings. See RFI responses and drawings attached. The due date is not extended in this amendment.
Solicitation332312Total Small Business Set-Aside07/17/202607/27/2026-
The purpose of this Amendment is to answer RFIs and attach additional drawings. See RFI responses and drawings attached. The due date is not extended in this amendment.
Solicitation332312Total Small Business Set-Aside07/17/202607/27/2026-

Additional Details

Solicitation Number

W912EF27QA002

Archive Date

Dec 30, 2026

Office Address

WALLA WALLA, WA, 99362-1876