GovChime
Notice ID: 5af279c064bc4bbdab82ba136888fa1bCombined Synopsis/SolicitationArchived

HVAC Replacement at USCG STA Washington

Archived on May 15, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
April 23, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of Homeland SecurityUS COAST GUARD

Notice details

Office
BASE NATIONAL CAPITAL REGION(000G8)
Place of performance
Bolling AFB, District of Columbia, 20032
PSC
N041: INSTALLATION OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
30252PR260000011
Notice ID
5af279c064bc4bbdab82ba136888fa1b

Description

HVAC replacemet in accordance with the Attached SOW, to include:

a. Determine heat load calculations for the HVAC system using installed ducting system.  Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.

b. Remove and dispose of the current outdoor and indoor units.  Unit will not have refrigerant in it.

c. Replace wiring and conduit from existing service disconnects to new pieces of equipment.  Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.

d. Replace all thermostat control wiring inside and outside with new UV rated wire.  Provide and replace existing thermostat to match the system function.   

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (3)

  • 30252PR260000011 STA Washington HVAC Load Test - 1442.pdf

    774 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • SOW - STA Washington HVAC.pdf

    54 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • FAR Clauses.pdf

    370 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    HVAC Replacement at USCG STA Washington

    Notice 5af279c064bc4bbdab82ba136888fa1b on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

30252PR260000011

Archive Date

May 15, 2026

Office Address

WASHINGTON, DC, 20593