HVAC Replacement at USCG STA Washington
Archived on May 15, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM EDT
- Posted
- April 23, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Homeland SecurityUS COAST GUARD
Notice details
- Office
- BASE NATIONAL CAPITAL REGION(000G8)
- Place of performance
- Bolling AFB, District of Columbia, 20032
- PSC
- N041: INSTALLATION OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
- Last updated
- Oct 31, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 30252PR260000011
- Notice ID
- 5af279c064bc4bbdab82ba136888fa1b
Description
HVAC replacemet in accordance with the Attached SOW, to include:
a. Determine heat load calculations for the HVAC system using installed ducting system. Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.
b. Remove and dispose of the current outdoor and indoor units. Unit will not have refrigerant in it.
c. Replace wiring and conduit from existing service disconnects to new pieces of equipment. Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.
d. Replace all thermostat control wiring inside and outside with new UV rated wire. Provide and replace existing thermostat to match the system function.
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (3)
- Download
30252PR260000011 STA Washington HVAC Load Test - 1442.pdf
774 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
SOW - STA Washington HVAC.pdf
54 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
FAR Clauses.pdf
370 KBAdded in Combined Synopsis/Solicitation version 3Posted