GovChime
Notice ID: 55f17727630340bf8529cfcf412f439fCombined Synopsis/SolicitationArchived

AIRFIELD LEAKING TRANSFORMER

Archived on August 30, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
August 4, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Agency
Department of Homeland SecurityUS COAST GUARD

Notice details

Office
BASE CAPE COD(00052)
Place of performance
Buzzards Bay, Massachusetts, 02542
PSC
J061: MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
31125260000817
Notice ID
55f17727630340bf8529cfcf412f439f

Description

SCOPE: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to remove and dispose of existing airfield lighting transformers and replace with refurbished, certified, and warrantied transformers (Fig. 1-11) at the U.S. Coast Guard, Base Cape Cod, on Joint Base Cape Cod, Buzzards Bay, MA, 02542. 1.1.1 Existing transformers: Contractors shall verify transformer specifications. 1) Transformer 413 (Fig. 1-3), adjacent to building 614 and runway 23. MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 ½, 65° RISE, serial number 74ZD743004, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % IMP. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 – SWITCH POSITION 2.4, VOLTAGE 7200 – SWITCH POSITION 7.2, VOLTAGE 7970 – SWITCH POSITION 7.9. Replace transformers in kind, or equal. 2) Transformer 523 (Fig. 4-6), adjacent to building 614 and runway 14, MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 ½, 65° rise, serial number 73ZE858030, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % imp. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 – SWITCH POSITION 2.4, VOLTAGE 7200 – SWITCH POSITION 7.2, VOLTAGE 7970 – SWITCH POSITION 7.9. Replace transformers in kind, or equal. 3) Transformer 138613 (Fig. 7-9), adjacent to hangar 3181 and taxiway Delta, Manufacturer ABB Jefferson City, MO, Style F25E017L67, Serial # 11JC573270001, KVA 1000/1120, AT CONTINUOUS RISE °C 55/65, MFG DATE JULY-2011, HIGH VOLTAGE 4160GRDY/2400, HV BIL KV 60, HV MTL AL, 5 IMPEDANCE 5.80, LOW VOLTAGE 480Y/277, LV BIL KV 30, LV MTL AL, GALLONS OIL 329, TOTAL WEIGHT IN POUNDS 7466. Replace transformers in kind, or equal. 1) Transformer 575 (Fig. 10-12), adjacent to building 195 and runway 5, Manufacturer Southeastern Transformer Co, Dunn, NC, single phase, 60 hertz, KVA 15, % imp. 3.6, serial number 1019102, volts 12470GRDY/7200-240/120. Replace transformers in kind, or equal. SEE UPDATED SOW FOR FULL REQUIREMENTS

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (5)

  • SOW Replace (4) Airfield Transformers .pdf

    651 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • 20260206_080225.jpg

    2.2 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • 20260206_080243.jpg

    1.2 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • Transformer_Standard Form 1449 - Solicitation_Contract_Order for Commercial Products and Commercial Services.pdf

    802 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • DBA WAGES BARNSTABLE COUNTY.txt

    55 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    AIRFIELD LEAKING TRANSFORMER

    Notice 7bfe13e4701c4726bbf86a26da59aed4 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    AIRFIELD LEAKING TRANSFORMER

    Notice ba62a298454d4d88a1c3722b5e06b67d on SAM.gov

  3. 4
    Version 4Combined Synopsis/SolicitationArchivedCurrent

    AIRFIELD LEAKING TRANSFORMER

    Notice 55f17727630340bf8529cfcf412f439f on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

31125260000817

Archive Date

Aug 30, 2026

Office Address