GovChime
Notice ID: ce31cc1ec36641bdbd8a9e494aa296e6Consolidate/(Substantially) BundleAwardedArchived

FUEL TANK INTEGRITY TESTING

Awarded on June 25, 2026. Full description on SAM.gov.

Overview

Posted
June 11, 2026
Notice type
Consolidate/(Substantially) Bundle
NAICS
541990: All Other Professional, Scientific, and Technical Services
Agency
Department of Homeland SecurityUS COAST GUARD

Notice details

Office
BASE CAPE COD(00052)
PSC
H291: EQUIPMENT AND MATERIALS TESTING- FUELS, LUBRICANTS, OILS, AND WAXES
Last updated
Oct 29, 2026
First published
Last updated on SAM.gov
Award date
Jun 25, 2026
Award amount (SAM.gov award notice)
Not specified

Identifiers

Solicitation number
31125PR260000720
Notice ID
ce31cc1ec36641bdbd8a9e494aa296e6

Description

1.1 SCOPE: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to perform external inspections of aboveground fuel tanks, and potassium sodium tanks.  Internal inspections and tank wall thickness measurements shall be included in inspection for three (3) tanks – one (1) 30,000 gallon JP-8 tank, and two (2) 15,000 gallon JP-8 tanks located adjacent to taxiway delta.    Contractor shall provide a detailed report of conditions found to include estimates for repairs. All work located at USCG Base Cape Cod in Bourne, MA 02542.  

1.1.2 REQUIRED WORK: This list should not be considered complete. It represents the general items needed to complete the contract requirements. Base Cape Cod manages six (6) above ground tanks that are greater than or equal to 6,000 gallons, that are used for the storage of fuel products.  Three (3) above ground tanks, used for the storage of gasoline, are located adjacent to Coast Guard Base Cape Cod’s (BCC) Mini Mart.  Two (2) of the tanks adjacent to BCC’s Mini-Mart have a 10,000 gallon capacity the third tank has a 6,000 gallon capacity.  Three (3) above ground tanks, used to store JP-8 (aviation fuel), are located adjacent to Taxiway Delta behind building 3170.  Two (2) of the tanks adjacent to Taxiway Delta have a 15,000 gallon capacity, the third tank has 30,000 gallon capacity. Base Cape Cod also manages two 5,000 gallon potassium sodium tanks located behind building 124. Inspect the tanks in accordance with Steel Tank Institute (STI) SP001 and complete the STI SP001 AST record. Perform wall thickness testing, and internal inspection IAW API 653.  Wall thickness testing, and internal inspection to only be completed on 30,000-gallon tank, and two (2) 15,000-gallon tanks located adjacent to taxiway delta.   Drafting a report on the condition of the tanks including any observed deterioration, the results of tests, and predictions of the expected service life remaining.

1.1.3 TANK INSPECTION SCHEDULE: Work shall be completed over a four (4) year period. Year 1; Inspect 30,000 gallon tank adjacent to taxiway delta Year 2, Inspect two (2) 15,000 gallon tanks adjacent to taxiway delta Year 3, Inspect two (2) 10,000 gallon tank adjacent to CGEX Year 4, Inspect 5,000 gallon tank adjunct to CGEX & (2) 5,000 gallon Potassium Sodium Tanks

SEE SOW FOR FULL DETAILS

Full description on SAM.gov

Award Overview

Award Number

31125PR260000720

Award Amount (SAM.gov award notice)

Not specified

Award Date

Jun 25, 2026

Awardee

Not specified

Original Solicitation

Notice ID: ce31cc1ec36641bdbd8a9e494aa296e6

Posted Date: Jun 11, 2026

Original Response Deadline: Not specified

Contract Details

Contract data not yet available

Contract details typically appear within 2-4 weeks after award; DoD awards are published about 90 days after signature.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (3)

  • DEI CLAUSE FOR SOLICITATIONS.docx

    15 KBAdded in Consolidate/(Substantially) Bundle version 3Posted
    Download
  • SF1449-21 SOLICITATION.pdf

    1009 KBAdded in Consolidate/(Substantially) Bundle version 3Posted
    Download
  • Tank Integrity Testing Statement of Work.doc

    137 KBAdded in Consolidate/(Substantially) Bundle version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Intent to BundleArchivedCurrent

    FUEL TANK INTEGRITY TESTING

    Notice ce31cc1ec36641bdbd8a9e494aa296e6 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

31125PR260000720

Archive Date

Jul 11, 2026

Office Address