Notice ID: 26e6e3769a50418b8b41b4b4a9111e3cSources SoughtArchived
6515--NX EQ Water Purification Systems: RO: HEMO: Portable (VA-26-00041965)
Archived on April 20, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:59 PM EST
- Posted
- February 5, 2026
- Notice type
- Sources Sought
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- SAC FREDERICK (36C10X)
- Place of performance
- Enterprise-wide https://www.va.gov/opal/sac/index.asp
- Last updated
- Nov 3, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C10X26Q0057
- Notice ID
- 26e6e3769a50418b8b41b4b4a9111e3c
Description
DESCRIPTION The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Evoqua Water Technologies, LLC EON® Water Purification Systems: RO: HEMO: Portable product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award. The Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Request for Information (RFI) in accordance with the FAR 10.001to determine the availability and technical capabilities of qualified sources. The period of performance will consist of a base of 12-months with four 12-month option periods from the date of award. The SAC in conjunction with VHA is seeking a qualified source to manufacture the Evoqua Water Technologies, LLC EON® Water Purification Systems: RO: HEMO: Portable on an agency wide basis. VA intends to award a Brand Name single award Requirements contract for this requirement IAW with FAR 16.503. Vendors will be required to deliver the Evoqua Water Technologies, LLC EON® Water Purification Systems: RO: HEMO: Portable to VA medical centers and facilities throughout the United States. The anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1250 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 SCOPE The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Evoqua Water Technologies, LLC EON® Water Purification Systems: RO: HEMO: Portable product line as a candidate for a VA-wide (otherwise referred to as national ) contract. Water Purification Systems: RO: HEMO: Portable are compact reverse osmosis (RO) hemodialysis water purification systems designed to produce ultra-pure dialysis grade water that meets current ANSI/AAMI/ISO standards for hemodialysis, and are compact, lightweight, portable systems (e.g., mounted on wheels) with integrated handles allowing for rapid relocation and set-up in multiple clinical environments. These systems are specifically engineered for very high-water volumes and strict contaminant limits required in hemodialysis, where even trace amounts of certain substances (such as aluminum, chloramines, or endotoxin) can cause serious patient harm. Portable hemodialysis RO systems typically include pretreatment (e.g., sediment and carbon filtration for particulate removal and chloramine/chlorine reduction), one or more semi permeable RO membranes, a high pressure pump to drive water across the membrane at pressures exceeding the osmotic gradient, and associated controls, monitors, and alarms. The RO membrane is permeable to water but largely impermeable to dissolved salts, organic molecules, microorganisms, and particulates, producing permeate (product water) that is then supplied to the hemodialysis machine via appropriate medical grade tubing and connectors. Compared with general purpose RO units, hemodialysis RO systems incorporate tighter performance specifications, continuous monitoring (e.g., conductivity, pressure), and disinfection capabilities to achieve and maintain very low levels of ions, bacteria, and endotoxin. Given patient exposure to hundreds of liters of water during a single hemodialysis session (as dialysate and substitution fluid), product water quality must be verified regularly through chemical and microbiological testing, using limits and action levels defined in applicable AAMI/ISO standards. Facilities typically incorporate upstream pretreatment to address local water characteristics (e.g., hardness, particulates, chloramines) before RO, and may add downstream ultrafiltration or endotoxin retentive filters to further control microbiological contaminants. Periodic disinfection of the RO system and distribution tubing is essential to control biofilm, and any deviation from specified water quality requires prompt investigation and corrective action. The following Contract Line Items are being considered: Contract Line Items Manufacturer Part Number Description 0001 Evoqua Water Technologies, LLC W3T578348 EON® Portable Reverse Osmosis (RO) Water Purification System (Includes: Disinfection Bottle, Manual, Hose Kit, Product Hose Assembly, AAMI Kit, Quick Reference Guide, Dialysis Machine Connection Hose, Feed Inlet Hose, Leak Detector, Insulation, and a 1-year Warranty) 0002 Evoqua Water Technologies, LLC W3T579396 ROVER ALX® Dialysis Water Transport System 0003 Evoqua Water Technologies, LLC W3T645898 Kit, Rover ALX®, RPZ, Valve, BF 0004 Evoqua Water Technologies, LLC W3T577765 Kit, Filter, ENX®, Replacement, EON®, 0.005M 0005 Evoqua Water Technologies, LLC W2T912087 Filter, Carbon Block 0006 Evoqua Water Technologies, LLC W2T913468 Filter, 1 Micron, 9 7/8 0007 Evoqua Water Technologies, LLC W2T913469 Filter, 5 Micron, 9 7/8 0008 Evoqua Water Technologies, LLC W2T913106 O-Ring, Pre-Filter, 9 7/8 0009 Evoqua Water Technologies, LLC W2T913384 O-Ring, Filter Housing, Buna 0010 Evoqua Water Technologies, LLC W3T578043 Kit, Hose Product, EON® Portable RO Machine TO Dialysis Machine 0011 Evoqua Water Technologies, LLC W3T574825 Kit, Hose, EON® 0012 Evoqua Water Technologies, LLC W3T572513 Y Coupling 0013 Evoqua Water Technologies, LLC W3T577915 Feed Hose Assembly 0014 Evoqua Water Technologies, LLC W3T578716 Product Hose Assembly 0015 Evoqua Water Technologies, LLC W2T921493 Connection Tubing Insulation 0016 Evoqua Water Technologies, LLC W2T934418 Cleaner, LiquiClean 113, 1Gal., Low pH, Liquid 0017 Evoqua Water Technologies, LLC W2T912365 Cleaner, LiquiClean 515 ,1Gal., High pH, Liquid 0018 Evoqua Water Technologies, LLC W2T912235 MINNCARE HD Disinfectant (4 Quarts) 0019 Evoqua Water Technologies, LLC W2T912238 MINNCARE HD Disinfectant Residual Test Strips 0020 Evoqua Water Technologies, LLC W2T914602 pH Test Strips 0021 Evoqua Water Technologies, LLC W2T915706 Hardness Test Kit 0022 Evoqua Water Technologies, LLC W3T578279 Silt Density Index (SDI) Test Kit 0023 Evoqua Water Technologies, LLC W2T915707 Total Chlorine Test Kit 0024 Evoqua Water Technologies, LLC 0025 Evoqua Water Technologies, LLC W3T572488 Water Test Kit, AAMI Standards 0026 Evoqua Water Technologies, LLC W3T578873 Kit, Chemical Bottle, EON® 0027 Evoqua Water Technologies, LLC W3T577803 Collection Assist Device 0028 Evoqua Water Technologies, LLC W3T577740 Float Switch, LS1 0029 Evoqua Water Technologies, LLC W2T912283 Fuse, 1.5A, FB 0030 Evoqua Water Technologies, LLC W2T912284 Fuse, 2.5A, FB 0031 Evoqua Water Technologies, LLC W2T912285 PSI Transducer 0032 Evoqua Water Technologies, LLC W2T922255 Sensor, Surface Leak Detector w/ Cable 0033 Evoqua Water Technologies, LLC W3TSP7028 Preventative Maintenance Service Agreement, Semi Annual. (Water samples not included. Includes additional filters needed monthly). Price is Annual Per Unit. Within CONUS. Locations outside CONUS subject to additional fees) *NOTE: At a minimum, Semi-Annual PM required to remain eligible for Extended Annual Warranty (CLINs X038 & X039) 0034 Evoqua Water Technologies, LLC W3TSP5222 Preventative Maintenance Service Agreement, Quarterly. (Water samples not included. Includes additional filters that are needed each month. Price is Annual Per Unit. Within CONUS. Locations outside CONUS subject to additional fees.) 0035 Evoqua Water Technologies, LLC W3TSP5217 Preventative Maintenance Service Agreement, Monthly. (Price is Annual Per Unit. Water samples not included. Within CONUS. Locations outside CONUS subject to additional fees.) 0036 Evoqua Water Technologies, LLC W3TSP7119 AAMI Water Samples, Product Water, Annual (Per Device; Must be done in conjunction with Preventative Maintenance Service Agreement). 0037 Evoqua Water Technologies, LLC W3TSP4959 Microbiology Water Samples, Quarterly (Per Device; CFU and LAL water samples. Must be done in conjunction with Quarterly Preventative Maintenance Service Agreement). 0038 Evoqua Water Technologies, LLC W3TSP7066 Microbiology Water Samples, Monthly (Per Device; CFU and LAL water samples. Must be done in conjunction with Monthly Preventative Maintenance Service Agreement). 0039 Evoqua Water Technologies, LLC W3TSP3048 Extended Annual Warranty Coverage (0-3 years old) (Price is annual per device. Within CONUS only. Requires Minimum Bi-Annual Preventative Maintenance Service Agreement. Existing devices are eligible for extended warranty coverage but must be assessed by Evoqua Service Technician and may require repairs prior to eligibility.) 0040 Evoqua Water Technologies, LLC W3TSP3049 Extended Annual Warranty Coverage (4-6 years old) (Price is annual per device. Within CONUS only. Requires Minimum Bi-Annual Preventative Maintenance Service Agreement. Existing devices are eligible for extended warranty coverage but must be assessed by Evoqua Service Technician and may require repairs prior to eligibility. Devices older than 7 years are supported, but are not subject to extended warranties and repairs on these devices will be billed separately) 0041 Evoqua Water Technologies, LLC W3TSP7110 Training, Technical, Onsite, EON® Portable RO, 1 Day, 8 MAX 0042 Evoqua Water Technologies, LLC W3TSP7109 Training, Clinical, Onsite, EON® Portable RO, 1/2 Day, 8 MAX 0043 Evoqua Water Technologies, LLC W3TSP4148 System Installation, Onsite (Per Device; Start up & Install of EON® Portable RO. Includes drawing initial AAMI sample and basic operators in service.) The Department of Veterans Affairs (VA) is seeking vendors who can provide the Evoqua Water Technologies, LLC EON® Portable RO Water Purification System as listed above which meet all the following minimum technical requirements. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero. Vendors shall provide descriptive literature which will be used to thoroughly evaluate each proposal to determine the extent to which it meets the Minimum Technical Requirements (MTRs) listed in the Combined Synopsis/Solicitation Notice. Vendors are required to complete the highlighted area on the MTRs Chart located on the Combined Synopsis/Solicitation document listing the location where compliance to the MTRs can be found. The chart must be included with the vendor s submission. Offers which do not include this complete chart will not be considered for award. CLIN 0001 applies to MTRs 1-9: CLIN 0002 applies to MTR 8: CLINs 0001 and 0032-0042 apply to MTR 9: MTR # Minimum Technical Requirements MTR Literature Map MTR 1 Must be FDA cleared as a portable reverse osmosis (RO) water purification system to produce AAMI certified (ANSI/AAMI 13959) purified water for hemodialysis treatments FDA Ltr (K200670) dtd 4/16/2020; EON Brochure Pages #1, 2; EON Data Sheet Pages #1, 2; EON Operation and Maintenance Manual Pages #8, 12, 13 MTR 2 Must have an Integrated Endotoxin Removal Ultrafilter with quick connect fittings to produce ultrapure dialysate per ANSI/AAMI 11663 EON ENX Filter Data Sheet Pages #1, 2; EON Brochure Page #2; EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #55, 111 MTR 3 Must be equipped with Heat ForwardTM technology and offer multiple internal heat disinfection methods/processes with optional chemical disinfection EON Brochure Page #2; EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #12, 15, 48-52, 70-75, 73, 93 MTR 4 Must have built-in and/or remote sensor for leak detection with automated user alert or shutdown EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #23, 25, 27, 36, 99, 101, 115, 126 MTR 5 Must monitor RO feed water pressure, RO feed water quality, pump outlet pressure, product water pressure, product water temperature, product water quality, and membrane performance (percent rejection) with associated user alarms/alerts EON Operation and Maintenance Manual Pages #88, 89, 100 MTR 6 Must have an LCD touch screen user interface EON Brochure Page #2; EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #29-37, 114 MTR 7 Must support data logging with the capability to retrieve / download basic patient treatment and system data EON Brochure Page #2; EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #27, 54, 55, 91 MTR 8 Must be portable and compatible with the ROVER ALX® Transport System ROVER ALX Brochure Page #2; EON Brochure Page #2; EON Data Sheet Page #1; EON Operation and Maintenance Manual Pages #1, 8, 12, 13 MTR 9 Must include standard one year warranty, offer options for an extended warranty, annual preventative maintenance services, training, and water testing Warranty and Service Parts Inclusion List; Open Market Quote dated 2026-01-27 For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the MTRs specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the MTRs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? If applicable, vendors are requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company SAM Unique Entity Identifier (UEI) / CAGE Code Business Size Manufacturer or Distributor If the distributor, provide manufacturer s full name, business size and address. Country of Origin designation for all products. Ability to provide uninterrupted supply of products on a national scale. Technical Literature that clearly shows product(s) meet the identified minimum technical requirements and page numbers where each minimum technical requirement is met. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter Certified by OEM with a current date. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. Contractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C10X26Q0057.docx
31 KBAdded in Sources Sought version 3Posted
Lifecycle
- 3Version 3Sources SoughtArchivedCurrent
6515--NX EQ Water Purification Systems: RO: HEMO: Portable (VA-26-00041965)
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
1.0 DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable. The EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal Fujifilm® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States. The associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission. Submissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: Alanna.Wilson@va.gov Anthony.Zibolski@va.gov Email responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. 2.0 SCOPE OF WORK Scanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacture Part Number Description 0001 Sonosite L22916 Transducer, L12-3 0002 Sonosite L23117 Transducer, C10-3 0003 Sonosite L23119 Transducer, C5-1 0004 Sonosite L23120 Transducer, L15-4 0005 Sonosite L23121 Transducer, IC10-3 0006 Sonosite L23972 Transducer, L19-5 0007 Sonosite L24087 Transducer, P5-1 0008 Sonosite L25100 Sonosite PX Ultrasound System 0009 Sonosite L25110 Sonosite PX Stand 0010 Sonosite L25200 Printer, B and W Hybrid Graphic, SONY UP-X898MD 0011 Sonosite L27766 T8-3 ULT-2020 Ultrasound Leakage Tester Kit 0012 Sonosite L28354 Sonosite LX Ultrasound System 0013 Sonosite L29076 Sonosite ECG Module 0014 Sonosite L29465 Transducer, T8-3 12 Months - Standard Coverage Warranty 0015 Sonosite L29671 Transducer, P11-3 0016 Sonosite L30229 Transducer, T8-3 POCUS Bundle -12 Months - Standard Coverage Warranty 0017 Sonosite L30257 Transducer, L13-6 0018 Sonosite L31500 Sonosite ST Ultrasound System 0019 Sonosite L33270 Transducer, UHF46-20 MHz Ultra High-Frequency -12 Months - Standard Coverage Warranty 0020 Sonosite P31199 Steep Needle Profiling, Sonosite ST 0021 Sonosite P31440 Sonosite Voice Assist -12 Months - Standard Coverage Warranty 0022 Sonosite P31987 Small Basket 0023 Sonosite P31988 Large Basket 0024 Sonosite P32357 - Sonosite PIV Assist Sonosite PIV Assist 0025 Sonosite P32441-SVCCON Point of Sale Warranty Plus (2 years), PX System 0026 Sonosite P32442-SVCCON Point of Sale Warranty Plus (2 years), LX System 0027 Sonosite P32443-SVCCON Point of Sale Warranty Plus (2 years), ST System 0028 Sonosite P32444-SVCCON Point of Sale Warranty Plus (2 years), PX/LX/ST/MT Transducers (Not applicable for the T8-3 or UHF46x Transducers) 0029 Sonosite Sonosite Institute for Point-of-Care Ultrasound Exclusive access to over 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included) Respondents should identify a complete solution including associated accessories, as required for full functionality. The following Salient Characteristics (SCs) are being considered: CLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9 CLINs 0014, 0016, 0019, 0021 apply to the following SC 10 CLINs 0026-0028 apply to the following SC 12 CLIN 0029 applies to the following SC 11 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Multiple configurations of the devices Literature Review SC 2 Must have High-quality image resolution1280 x 1024 pixels or higher Literature Review SC 3 Must have multiple Doppler modes to include color, and continuous Wave Literature Review SC 4 Must have 120V and Battery powered capability Literature Review SC 5 Must have a Phased Array Probe with a low frequency range of between 1-5 MHz Literature Review SC 6 Must have Endocavitary Probe with a frequency range between 2-12.5 MHz Literature Review SC 7 Must have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe Literature Review SC 8 Must have Linear Probe with a frequency range greater than 12 MHz Literature Review SC 9 Must have needle visualization enhancement Literature Review SC 10 Must have a minimum one-year warranty Literature Review SC 11 Must provide Operator training Literature Review SC 12 Must provide Extended Service and Support plan Literature Review SC 13 Must be FDA approved FDA Letter SC 14 Must have Intraoperative system capable of interfacing with VA Electronic Health Record System Literature Review For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above. The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number. In addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors: Safety The device will be assessed for patient safety features, including, but not limited to, the following areas: Infection control Thermal injuries Probe maintenance Battery failure procedures Design Design features and functions of the offered device will be evaluated. Areas include but are not limited to the following: Durability of the system and the probes Display screens usability Barcode software to ID patients and physicians Low-Profile wheelbase to assist getting closer to patient Cordless charging station Number of Transducer ports Simplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use) Performance The device will be evaluated for its ability to perform its intended function. Areas include but are not limited to: Capabilities to support multiple medical services Batter run time Provided Installation Needle guidance system Quality/Construction/Training Extended Warranty Training Secure Data encryption HIPPAA/GDPR compliant Meets ANSI/AAMI ES6061 Electromechanical safety standards Responses to this Sources Sought Notice shall include the following: Full name and address of company. SAM Unique Entity Identifier (UEI). Business Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)). Manufacturer or Distributor: If distributor, provide the full name, business size and address of the manufacturer. If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. Country of Origin designation for all products proposed. Describe the firm s ability to provide uninterrupted supply of products on a national scale. Technical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met. Does respondent offer an annual service plan, Yes or No? If Yes: Describe what the plan covers? Identify whether the plan covers software updates, parts repair/replacement, or both Provide literature or other documentation describing the service plan. Identify whether service is provided by the OEM or a subcontractor. Identify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns. Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted. Identify any federal contract vehicles held by your firm through which your firm can provide this equipment. Are there any further standards or criteria VA should consider in a procurement action for this equipment? Are the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language. Any additional information the Government should know prior to issuing a solicitation. Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis. | 98% | Market Research | 10/19/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | 80% | Combined Synopsis | 12/01/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with FAR part 12. This announcement constitutes the only solicitation. Proposals are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0004 is issued as a Request for Proposals (RFP) for Image-Guided Surgical Navigation Systems. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A - PRICE COST SCHEDULE_NX EQ Image-Guided Surgical Navigation System for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide NX EQ Image-Guided Surgical Navigation Systems that meet the salient characteristics listed in ATTACHMENT B PRODUCT DESCRIPTION. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | 80% | Combined Synopsis | 11/05/2026 |
Sources Sought Notice Sources Sought Notice DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO) is issuing this Sources Sought Notice in accordance with FAR 10.002(b)(2) as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Ultrasound Therapy Systems: Tissue Ablation. The EPO in conjunction with VHA is seeking a qualified source to supply brand name, brand-name-or-equal, or sole-source specification for Ultrasound Therapy Systems: Tissue Ablation and associated equipment on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the required products to VA medical centers and facilities throughout the United States. The period of performance is for a base of 12-months with four 12-month option periods. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 and the associated size standard is 1,250 Employees. The FAR Provision found at 52.204-7(b)(1) requires that an offeror be registered in SAM when submitting an offer or quotation and at time of award. All respondents should have the appropriate NAICS code reflected in SAM. SDVOSB/VOSB respondents should maintain current certification in the SBA Veteran Small Business Certification program, as applicable. Submissions for this sources sought shall be submitted by email no later than September 30, 2026, at 9:00 am ET to: Michael.Andrews6@va.gov. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. SCOPE OF WORK Ultrasonic Aspirators are surgical devices designed to fragment and remove soft tissue, bone, and tumors from various parts of the body. They are used during procedures in which surgical blades or blunt dissection instruments might damage surrounding healthy tissue or for cases in which a surgical laser would eradicate a lesion, leaving no specimen for pathological evaluation. Ultrasonic aspirators utilize mechanical vibration at ultrasonic frequencies for tissue removal while also providing suction and/or irrigation to the surgical site. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacturer Part Number Description 0001 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0002 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0003 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0004 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0005 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) 0006 Integra LifeSciences C7136 CUSA Clarity 36kHz Sterilization Tray 0007 Integra LifeSciences C7602 CUSA CLARITY 36kHz TORQUE WRENCH (5-PACK) 0008 Integra LifeSciences C7300 CUSA CLARITY QUICK CONNECT TUBING SET (5-PACK) 0009 Integra LifeSciences C7005 CUSA Clarity Contamination Guard 0010 Integra LifeSciences C7550 CUSA Clarity Specimen Trap 0011 Integra LifeSciences C7123 CUSA Clarity 23kHz Sterilization Tray 0012 Integra LifeSciences C7623 CUSA Clarity 23kHz Sterilizable Torque Base EACH1 0013 Integra LifeSciences C7601 CUSA Clarity 23kHz Torque Wrench (5-Pack) 0014 Integra LifeSciences C7502 CUSA Clarity 23kHz Handpiece Cleaning Brush 0015 Integra LifeSciences C7523 CUSA CLARITY 23kHz CEM NOSECONE (5 PACK) 0016 Integra LifeSciences C7401S CUSA Clarity 23kHz Standard Tip (5-pack) 0017 Integra LifeSciences C7405S CUSA Clarity 23kHz MacroTip (5-Pack) 0018 Integra LifeSciences C7418S CUSA Clarity 23kHz Tough Tissue Tip (5-pack) 0019 Integra LifeSciences C7420S CUSA Clarity 23kHz Bone Tip (5-pack) 0020 Integra LifeSciences C7002 CUSA Clarity Footswitch 0021 Integra LifeSciences C7421S CUSA Clarity 23kHz Single-Sided Bone Tip (5-Pack) 0022 Integra LifeSciences C7404LS Clarity 23kHz Extended Laparoscopic Tip, 5-Pack 0023 Integra LifeSciences C7636 CUSA Clarity 36kHz Sterilizable Torque Base EACH1 0024 Integra LifeSciences C7523X CUSA Clarity 23kHz Expanded CEM Nosecone - 5 Pack 0025 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0026 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0027 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0028 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0029 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) The Department of Veterans Affairs (VA) is seeking vendors who can provide Cusa Clarity Ultrasonic Aspirator System, Ultrasound Therapy Systems: Tissue Ablation or equal commodities that meet the salient characteristics below. Vendors may provide any product solution or configuration that meets the requirement. For each offered product, the response should include descriptive literature demonstrating how the product meets or exceeds each salient characteristic. The following salient characteristics apply to the products identified below unless otherwise noted in the Product Description: CLIN s 0001 apply to the following SC s: SC1, SC2, SC3, SC4, SC5, SC6 CLIN s 0003-CLIN s 0029 apply to the following SC: SC7 SC # SALIENT CHARACTERISTICS Apply to CLIN # METHOD OF EVALUATION 1 Console includes a visual display that provides real-time feedback on ultrasonic power/amplitude, irrigation rate, and aspiration level, with numerical or graphical indicators. 0001 Literature Review 2 Provides combined ultrasonic fragmentation/emulsification, irrigation, and aspiration functions for soft and hard (including bone) tissue. 0001 Literature Review 3 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 4 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 5 System supports at least two ultrasonic handpieces with distinct operating frequencies (e.g., one high-frequency for fine, selective work and one lower-frequency/high-amplitude for efficient debulking of tougher tissue). 0001 Literature Review 6 System provides continuous irrigation from standard sterile saline or lactated Ringer s bags to the distal tip of the handpiece and aspiration of irrigation fluid, fragmented tissue, and debris to standard canisters via vacuum tubing. 0001 Literature Review 7 Reusable handpieces and components are compatible with standard hospital sterilization processes, including pre-vacuum steam sterilization cycles with manufacturer-specified dry times (e.g., 40 minute dry cycle) 0003-0029 Literature Review Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does the plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor is requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company UEI / CAGE Code / SAM registration information Business Size Manufacturer or Distributor If distributor, provide full name, business size, and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale Technical literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter certified by OEM with a current date. Although not required, vendors responding to this Sources Sought are highly encouraged to submit a Capabilities Statement. | 80% | Market Research | 09/30/2026 |
NX EQ Image Guided Surgical Navigation System | 77% | Market Research | 09/18/2026 |
Additional Details
Solicitation Number
36C10X26Q0057
Archive Date
Apr 20, 2026
Office Address