GovChime
Archived

6515--NX EQ Monitors_Physio_Neurology_Intraop_EEG

Overview

Response deadline
12:00 PM EDT
Posted
March 26, 2026
Notice type
Sources Sought
NAICS
334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
SAC FREDERICK (36C10X)
Place of performance
Enterprise-wide
Last updated
Nov 1, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C10X26Q0066
Notice ID
4a9679336a6c4475bb70127b2e4c85f0

Description

1.0 DESCRIPTION The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Electroencephalography (EEG): Electroencephalographic product line as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as national ) Non-Expendable Equipment (NX) Requirements contract award. The Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with Revolutionary FAR Overhaul (RFO) 10.001 to determine the availability and technical capabilities of qualified sources. The SAC in conjunction with VHA is seeking a qualified source to provide Natus®, Inc brand name or equal Electroencephalography (EEG): Electroencephalographic systems and components on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW RFO 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Electroencephalography (EEG): Electroencephalographic systems and components to VA medical centers and facilities throughout the United States. The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The RFO Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation in response to this solicitation and at the time of award. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 SCOPE Electroencephalography uses electrodes placed on a patient's scalp to measure, amplify, filter, and record the electrical signals (EEG signals) generated by the brain and subsequently display the acquired patient data in digital wave forms. There are three Neuroiagnostic procedures that Electroencephalographic systems are used for, Electroencephalography (EEG), Intraoperative Monitoring (IONM), Long-Term Monitoring (LTM). The first Neurodiagnostic procedure, EEG is used in areas such Outpatient Labs, Inpatient Wards, and ICU settings. It observes and diagnoses a range of neurologic conditions, including epilepsy. It can also be employed to evaluate psychiatric disorders and differentiate them from neurologic conditions. IONM has the capability to monitor the functional integrity of neural structures during surgeries such as Carotid Endarterectomy, Corticography, Brain Mapping, Stimulation, Aneurysm Clipping, and the effects of anesthesia on the brain during these procedures. LTM is the collection of EEG data over a period of time. These recordings include Ambulatory EEG (aEEG), which is used for recording at the Veteran s residence. Continuous EEG (cEEG) is used for inpatient video monitoring greater than 2 hours. Prolonged EEG (pEEG) monitoring is used for outpatient video monitoring greater than 2 hours. Video EEG (vEEG) is an elective EEG admission for prolonged video EEG recording which is performed in an Epilepsy Monitoring Unit (EMU). An EMU is a specialized inpatient unit designed to evaluate, diagnose, and treat seizures. The ability to record and monitor non-invasive scalp electrode EEG, intracranial EEG (Grid and Strip), and invasive stereotactic depth electrodes (sEEG) is the gold standard using state-of-the art continuous video electroencephalogram (vEEG) monitoring technology. The following Contract Line Items are being considered: Contract Line Items Manufacture Part Number Description Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4 0001 NATUS INC PK1204HD EEG/Sleep Acq Desktop with IP PTZ 1080p HD Color/BW Camera on ErgoJust Cart 10 10 10 10 10 0002 NATUS INC UPS-NA-EJ Medical Grade UPS with Isolation - 110V ErqoJust Cart 10 10 10 10 10 0003 NATUS INC PK1274 Natus Brain Monitor Amplifier 10 10 10 10 10 0004 NATUS INC PK1102 LED Photic Stimulator. 10 10 10 10 10 0005 NATUS INC 23431 Natus Brain Monitor BB Holster/Arm Cart Kit 10 10 10 10 10 0006 NATUS INC AMB-MON- VIDWIFl-10 Ambulatory Monitoring Package with Tablet, Software NW 10, Single IP Wi-Fi Camera Kit - 11 10 10 10 10 10 0007 NATUS INC PK1108T-FHD EEG/Sleep Tech Room Acquisition Desktop with Ceiling Mount 1080p HD IP PTZ Camera 10 10 10 10 10 0008 NATUS INC UPS-NA Medical Grade UPS with Isolation (North America 5-15R HG pluQ) 10 10 10 10 10 0009 NATUS INC PK1072-NTB-9 EMU40EX with new Natus Base (Requires NW 9.x or newer) 10 10 10 10 10 0010 NATUS INC 10368 EMU40 / Brain Monitor Wall Mount Kit 10 10 10 10 10 0011 NATUS INC PK1058 Small-form Factor Computer (NeuroWorks/SleepWorks not Included) 10 10 10 10 10 0012 NATUS INC LC105-10 NeuroWorks 10.x Nurse Station Software 10 10 10 10 10 0013 NATUS INC PK1014 Review/Monitoring Desktop (NeuroWorks software not included) 10 10 10 10 10 0014  LC102-10 NeuroWorks 10.x Review Software      0015 NATUS INC PK1103 LED Photic Stimulator with Stand 10 10 10 10 10 0016 NATUS INC PSG-WALL- PTZHD-SDX-10 PTZ Video, SDx amp, SleepWorks 10, no Sensor Kit SleepWorks Sys with Wall Mounted 1080p 10 10 10 10 10 0017 NATUS INC PSG-CEIL-PTZHD- SDX-10 SleepWorks System with Ceiling Mounted1080p PTZ Video,SDx amp, SleepWorks 10, no Sensor Kit 10 10 10 10 10 0018 NATUS INC PSG-WALL-PTZ- FHD-NDX-10 SleepWorks system Wall mount 1080p PTZ, Embla NDx, PC, 24" LCD, SleepWorks V10.x, Rpt Ed. 10 10 10 10 10 0019 NATUS INC PSG-CEIL-PTZ- FHD-NDX-10 SleepWorks system Ceiling mount 1080p PTZ, Embla NDx, PC, 24" LCD, SleepWorks V10.x, Rpt Ed 10 10 10 10 10 0020 NATUS INC 2929 Persyst Continuous/ Long-term Monitoring (Persyste) 10 10 10 10 10 0021 NATUS INC 105075XL 24in FP Monitor 40 40 40 40 40 0022 NATUS INC LC101-10 NeuroWorks 10.x Acquisition Software with Spike / Event and Hiqh Res Video 40 40 40 40 40 0023 NATUS INC REPORT-EDITOR MS Word Report Editor for Neuroworks/Sleepworks 10 10 10 10 10 0024 NATUS INC 10193 Extended Video Monitoring Controllers 30 30 30 30 30 0025 NATUS INC NO-ISO Isolation Transformer Not Included. 30 30 30 30 30 0026 NATUS INC 24252 Sleep Supplies Starter Kit with Single Use Supplies for Embla DX Series Amplifiers 10 10 10 10 10 0027 NATUS INC SVC808BM01 Xitek BIoMed Trg @natus 10 10 10 10 10 0028 NATUS INC 48354 Logitech Wireless Keyboard and mouse for Trex HDM Case (English) 40 40 40 40 40 0029 NATUS INC 48355 Hand Cart for Trex HDM Ez-Case 10 10 10 10 10 0030 NATUS INC 4244014 Prem Intercom Sys W/Recording 10 10 10 10 10 0031 NATUS INC 015968 Star Tech Pcle Gigabit NIC 10 10 10 10 10 0032 NATUS INC SVC800INSTALl_INC Installation Included 40 40 40 40 40 0033 NATUS INC SVC800TRAIN_INC Training Included 40 40 40 40 40 0034 NATUS INC EEG Monitoring System 1 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Billable On Site Support - Labor, Travel & expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0035 NATUS INC EEG Monitoring System 1 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0036 NATUS INC EEG Monitoring System 1 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation), 1 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0037 NATUS INC Ambulatory Monitoring System 1 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0038 NATUS INC Ambulatory Monitoring System 1 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0039 NATUS INC Ambulatory Monitoring System 1 Year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0040 NATUS INC NDx Sleep Works System 1 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0041 NATUS INC NDx Sleep Works System 1 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0042 NATUS INC NDx Sleep Works System 1 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0043 NATUS INC SDx Sleep Works Basic Care Service Coverage Benefits One Year only. Coverage Dates: TBD (1 year after installation). One Year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0044 NATUS INC SDx Sleep Works System 1 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0045 NATUS INC SDx Sleep Works System 1 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 1 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0046 NATUS INC EEG Monitoring System 5 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Billable On Site Support - Labor, Travel & expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0047 NATUS INC EEG Monitoring System 5 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0048 NATUS INC EEG Monitoring System 5 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation), 5 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0049 NATUS INC Ambulatory Monitoring System 5 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0050 NATUS INC Ambulatory Monitoring System 5 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0051 NATUS INC Ambulatory Monitoring System 5 Year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0052 NATUS INC NDx Sleep Works System 5 year Basic Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0053 NATUS INC NDx Sleep Works System 5 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0054 NATUS INC NDx Sleep Works System 5 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0055 NATUS INC SDx Sleep Works Basic System 5 year Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Billable On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and Billable Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0056 NATUS INC SDx Sleep Works System 5 year Flex Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, 2 Visits / Year / Per Facility On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Billable Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available), and 16 Hours / Year / Per Facility Professional Services (Remote Support Only). All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 0057 NATUS INC SDx Sleep Works System 5 year Advance Care Service Coverage Benefits. Coverage Dates: TBD (1 year after installation). 5 year only, Unlimited On Site Support - Labor, Travel & Expenses, Priority Technical Support Phone Queue with PIN Access, Service Parts Replacement/Repair Including and Overnight Shipping on Part(s) In Stock - Loaner Provided if Required, Performance/Maintenance Check with Inventory Verification Upon Customer Request, Software Updates Upon Customer Request (When Available),Professional Services (Remote Support Only), 10% Discount Software Version Upgrades (When Available), 50% Discount Biomed / IT Training (Tuition Only), and 50% Discount NTA Clinical Training Courses (when available, tuition only, in-house). Visit www.neuro-training.academy. All options excludes Persyst Software Assurance Agreement. HL7 is remote support only. Coverage does not include modifications to the interface. 10 10 10 10 10 The Department of Veterans Affairs (VA) is seeking vendors who can provide the Steris Corporation® V-Pro Max 2 Sterilizer or equal as listed above which meet all the following salient characteristics: CLIN's 0001 to 00031 apply to SC's 1-10, SC 12, and SC 14 CLIN's 0034-0057 apply to SC 11 CLIN 0033 applies to SC 13 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Must have the capability to perform EEG (Routine) assessments by acquiring and recording data. Literature Review SC 2 EEG system must have a fully wireless in-home care (Ambulatory) configuration option Literature Review SC 3 Must have the polysomnography (PSG) package option to perform a full sleep study Literature Review SC 4 Must have EEG analysis software Literature Review SC 5 Must have Seizure and Spike/Burst Detection Literature Review SC 6 Must be able to simultaneously collect video and audio data during EEG data collection Literature Review SC 7 Must have Remote viewing capabilities Literature Review SC 8 EEG must have continuous audio and video (with infrared) data recording capability for assessments greater than two hours (Long Term) Literature Review SC 9 Must have a minimum of 32 channels Literature Review SC 10 Must be Electromagnetic Emissions IEC 60601-2 compliant Literature Review SC 11 Must provide extended service and support plan option. Literature Review SC 12 Must have minimum one-year Warranty Literature Review SC 13 Must provide training. Literature Review SC 14 FDA or 501(K) approved Literature Review For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Full name and address of company; Unique Entity Identifier (UEI) number; Business Size; Manufacturer or Distributor; If distributor provide full name, business size and address of manufacturer. Country of Origin designation for all products; Ability to provide uninterrupted supply of products on a national scale; Technical Literature that clearly shows product(s) meet the identified SCs (if submitting an or-equal item); Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. Contractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Levi Russin
Contract Specialist

Documents

Files (1)

  • 36C10X26Q0066.docx

    40 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6515--NX EQ Monitors_Physio_Neurology_Intraop_EEG

    Notice 4a9679336a6c4475bb70127b2e4c85f0 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract.
-Combined Synopsis12/01/2026
This is a combined synopsis/solicitation for commercial products prepared in accordance with FAR part 12. This announcement constitutes the only solicitation. Proposals are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0004 is issued as a Request for Proposals (RFP) for Image-Guided Surgical Navigation Systems. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A - PRICE COST SCHEDULE_NX EQ Image-Guided Surgical Navigation System for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide NX EQ Image-Guided Surgical Navigation Systems that meet the salient characteristics listed in ATTACHMENT B PRODUCT DESCRIPTION. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract.
-Combined Synopsis11/05/2026
See attached document: 36C10X26R0062 See attached document: SF30 36C10X26R0062 0002
-Solicitation10/16/2026
1.0 DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable. The EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal Fujifilm® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States. The associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission. Submissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: Alanna.Wilson@va.gov Anthony.Zibolski@va.gov Email responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. 2.0 SCOPE OF WORK Scanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacture Part Number Description 0001 Sonosite L22916 Transducer, L12-3 0002 Sonosite L23117 Transducer, C10-3 0003 Sonosite L23119 Transducer, C5-1 0004 Sonosite L23120 Transducer, L15-4 0005 Sonosite L23121 Transducer, IC10-3 0006 Sonosite L23972 Transducer, L19-5 0007 Sonosite L24087 Transducer, P5-1 0008 Sonosite L25100 Sonosite PX Ultrasound System 0009 Sonosite L25110 Sonosite PX Stand 0010 Sonosite L25200 Printer, B and W Hybrid Graphic, SONY UP-X898MD 0011 Sonosite L27766 T8-3 ULT-2020 Ultrasound Leakage Tester Kit 0012 Sonosite L28354 Sonosite LX Ultrasound System 0013 Sonosite L29076 Sonosite ECG Module 0014 Sonosite L29465 Transducer, T8-3 12 Months - Standard Coverage Warranty 0015 Sonosite L29671 Transducer, P11-3 0016 Sonosite L30229 Transducer, T8-3 POCUS Bundle -12 Months - Standard Coverage Warranty 0017 Sonosite L30257 Transducer, L13-6 0018 Sonosite L31500 Sonosite ST Ultrasound System 0019 Sonosite L33270 Transducer, UHF46-20 MHz Ultra High-Frequency -12 Months - Standard Coverage Warranty 0020 Sonosite P31199 Steep Needle Profiling, Sonosite ST 0021 Sonosite P31440 Sonosite Voice Assist -12 Months - Standard Coverage Warranty 0022 Sonosite P31987 Small Basket 0023 Sonosite P31988 Large Basket 0024 Sonosite P32357 - Sonosite PIV Assist Sonosite PIV Assist 0025 Sonosite P32441-SVCCON Point of Sale Warranty Plus (2 years), PX System 0026 Sonosite P32442-SVCCON Point of Sale Warranty Plus (2 years), LX System 0027 Sonosite P32443-SVCCON Point of Sale Warranty Plus (2 years), ST System 0028 Sonosite P32444-SVCCON Point of Sale Warranty Plus (2 years), PX/LX/ST/MT Transducers (Not applicable for the T8-3 or UHF46x Transducers) 0029 Sonosite Sonosite Institute for Point-of-Care Ultrasound Exclusive access to over 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included) Respondents should identify a complete solution including associated accessories, as required for full functionality. The following Salient Characteristics (SCs) are being considered: CLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9 CLINs 0014, 0016, 0019, 0021 apply to the following SC 10 CLINs 0026-0028 apply to the following SC 12 CLIN 0029 applies to the following SC 11 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Multiple configurations of the devices Literature Review SC 2 Must have High-quality image resolution1280 x 1024 pixels or higher Literature Review SC 3 Must have multiple Doppler modes to include color, and continuous Wave Literature Review SC 4 Must have 120V and Battery powered capability Literature Review SC 5 Must have a Phased Array Probe with a low frequency range of between 1-5 MHz Literature Review SC 6 Must have Endocavitary Probe with a frequency range between 2-12.5 MHz Literature Review SC 7 Must have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe Literature Review SC 8 Must have Linear Probe with a frequency range greater than 12 MHz Literature Review SC 9 Must have needle visualization enhancement Literature Review SC 10 Must have a minimum one-year warranty Literature Review SC 11 Must provide Operator training Literature Review SC 12 Must provide Extended Service and Support plan Literature Review SC 13 Must be FDA approved FDA Letter SC 14 Must have Intraoperative system capable of interfacing with VA Electronic Health Record System Literature Review For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above. The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number. In addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors: Safety The device will be assessed for patient safety features, including, but not limited to, the following areas: Infection control Thermal injuries Probe maintenance Battery failure procedures Design Design features and functions of the offered device will be evaluated. Areas include but are not limited to the following: Durability of the system and the probes Display screens usability Barcode software to ID patients and physicians Low-Profile wheelbase to assist getting closer to patient Cordless charging station Number of Transducer ports Simplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use) Performance The device will be evaluated for its ability to perform its intended function. Areas include but are not limited to: Capabilities to support multiple medical services Batter run time Provided Installation Needle guidance system Quality/Construction/Training Extended Warranty Training Secure Data encryption HIPPAA/GDPR compliant Meets ANSI/AAMI ES6061 Electromechanical safety standards Responses to this Sources Sought Notice shall include the following: Full name and address of company. SAM Unique Entity Identifier (UEI). Business Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)). Manufacturer or Distributor: If distributor, provide the full name, business size and address of the manufacturer. If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. Country of Origin designation for all products proposed. Describe the firm s ability to provide uninterrupted supply of products on a national scale. Technical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met. Does respondent offer an annual service plan, Yes or No? If Yes: Describe what the plan covers? Identify whether the plan covers software updates, parts repair/replacement, or both Provide literature or other documentation describing the service plan. Identify whether service is provided by the OEM or a subcontractor. Identify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns. Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted. Identify any federal contract vehicles held by your firm through which your firm can provide this equipment. Are there any further standards or criteria VA should consider in a procurement action for this equipment? Are the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language. Any additional information the Government should know prior to issuing a solicitation. Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.
-Market Research10/19/2026
Sources Sought Notice Sources Sought Notice DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO) is issuing this Sources Sought Notice in accordance with FAR 10.002(b)(2) as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Ultrasound Therapy Systems: Tissue Ablation. The EPO in conjunction with VHA is seeking a qualified source to supply brand name, brand-name-or-equal, or sole-source specification for Ultrasound Therapy Systems: Tissue Ablation and associated equipment on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the required products to VA medical centers and facilities throughout the United States. The period of performance is for a base of 12-months with four 12-month option periods. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 and the associated size standard is 1,250 Employees. The FAR Provision found at 52.204-7(b)(1) requires that an offeror be registered in SAM when submitting an offer or quotation and at time of award. All respondents should have the appropriate NAICS code reflected in SAM. SDVOSB/VOSB respondents should maintain current certification in the SBA Veteran Small Business Certification program, as applicable. Submissions for this sources sought shall be submitted by email no later than September 30, 2026, at 9:00 am ET to: Michael.Andrews6@va.gov. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. SCOPE OF WORK Ultrasonic Aspirators are surgical devices designed to fragment and remove soft tissue, bone, and tumors from various parts of the body. They are used during procedures in which surgical blades or blunt dissection instruments might damage surrounding healthy tissue or for cases in which a surgical laser would eradicate a lesion, leaving no specimen for pathological evaluation. Ultrasonic aspirators utilize mechanical vibration at ultrasonic frequencies for tissue removal while also providing suction and/or irrigation to the surgical site. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacturer Part Number Description 0001 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0002 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0003 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0004 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0005 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) 0006 Integra LifeSciences C7136 CUSA Clarity 36kHz Sterilization Tray 0007 Integra LifeSciences C7602 CUSA CLARITY 36kHz TORQUE WRENCH (5-PACK) 0008 Integra LifeSciences C7300 CUSA CLARITY QUICK CONNECT TUBING SET (5-PACK) 0009 Integra LifeSciences C7005 CUSA Clarity Contamination Guard 0010 Integra LifeSciences C7550 CUSA Clarity Specimen Trap 0011 Integra LifeSciences C7123 CUSA Clarity 23kHz Sterilization Tray 0012 Integra LifeSciences C7623 CUSA Clarity 23kHz Sterilizable Torque Base EACH1 0013 Integra LifeSciences C7601 CUSA Clarity 23kHz Torque Wrench (5-Pack) 0014 Integra LifeSciences C7502 CUSA Clarity 23kHz Handpiece Cleaning Brush 0015 Integra LifeSciences C7523 CUSA CLARITY 23kHz CEM NOSECONE (5 PACK) 0016 Integra LifeSciences C7401S CUSA Clarity 23kHz Standard Tip (5-pack) 0017 Integra LifeSciences C7405S CUSA Clarity 23kHz MacroTip (5-Pack) 0018 Integra LifeSciences C7418S CUSA Clarity 23kHz Tough Tissue Tip (5-pack) 0019 Integra LifeSciences C7420S CUSA Clarity 23kHz Bone Tip (5-pack) 0020 Integra LifeSciences C7002 CUSA Clarity Footswitch 0021 Integra LifeSciences C7421S CUSA Clarity 23kHz Single-Sided Bone Tip (5-Pack) 0022 Integra LifeSciences C7404LS Clarity 23kHz Extended Laparoscopic Tip, 5-Pack 0023 Integra LifeSciences C7636 CUSA Clarity 36kHz Sterilizable Torque Base EACH1 0024 Integra LifeSciences C7523X CUSA Clarity 23kHz Expanded CEM Nosecone - 5 Pack 0025 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0026 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0027 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0028 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0029 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) The Department of Veterans Affairs (VA) is seeking vendors who can provide Cusa Clarity Ultrasonic Aspirator System, Ultrasound Therapy Systems: Tissue Ablation or equal commodities that meet the salient characteristics below. Vendors may provide any product solution or configuration that meets the requirement. For each offered product, the response should include descriptive literature demonstrating how the product meets or exceeds each salient characteristic. The following salient characteristics apply to the products identified below unless otherwise noted in the Product Description: CLIN s 0001 apply to the following SC s: SC1, SC2, SC3, SC4, SC5, SC6 CLIN s 0003-CLIN s 0029 apply to the following SC: SC7 SC # SALIENT CHARACTERISTICS Apply to CLIN # METHOD OF EVALUATION 1 Console includes a visual display that provides real-time feedback on ultrasonic power/amplitude, irrigation rate, and aspiration level, with numerical or graphical indicators. 0001 Literature Review 2 Provides combined ultrasonic fragmentation/emulsification, irrigation, and aspiration functions for soft and hard (including bone) tissue. 0001 Literature Review 3 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 4 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 5 System supports at least two ultrasonic handpieces with distinct operating frequencies (e.g., one high-frequency for fine, selective work and one lower-frequency/high-amplitude for efficient debulking of tougher tissue). 0001 Literature Review 6 System provides continuous irrigation from standard sterile saline or lactated Ringer s bags to the distal tip of the handpiece and aspiration of irrigation fluid, fragmented tissue, and debris to standard canisters via vacuum tubing. 0001 Literature Review 7 Reusable handpieces and components are compatible with standard hospital sterilization processes, including pre-vacuum steam sterilization cycles with manufacturer-specified dry times (e.g., 40 minute dry cycle) 0003-0029 Literature Review Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does the plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor is requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company UEI / CAGE Code / SAM registration information Business Size Manufacturer or Distributor If distributor, provide full name, business size, and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale Technical literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter certified by OEM with a current date. Although not required, vendors responding to this Sources Sought are highly encouraged to submit a Capabilities Statement.
-Market Research09/30/2026

Additional Details

Solicitation Number

36C10X26Q0066

Archive Date

Jun 8, 2026

Place of Performance Country

CONUS and OCONUS

Office Address

FREDERICK, MD, 21703