Notice ID: 55f71ab472c24920a740a97b6bb44915Award NoticeAwarded
C1NB--689A4-23-123, AE Replace Boiler Plant and Chiller Plant
Awarded on September 19, 2023. Full description on SAM.gov.
Awarded tounder 36C24123C0100 (source: SAM.gov award notice)• $948.4K
Overview
- Posted
- September 28, 2023
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541330: Engineering Services
- Agency
- Department of Veterans Affairs
Notice details
- Last updated
- Dec 4, 2025
- Award date
- Sep 19, 2023
- Award amount (SAM.gov award notice)
- $948.4K
Identifiers
- Solicitation number
- 36C24123R0057
- Notice ID
- 55f71ab472c24920a740a97b6bb44915
- Award number (PIID)
- 36C24123C0100
Description
SPECIAL NOTICE - REQUEST FOR QUALIFICATIONS (SF-330) NAICS Code: 541330 Engineering Services (Small Business size standard $22.5 million dollars) A. INTRODUCTION: The VA Connecticut Healthcare System (VACHS), Newington Campus, located at 555 Willard Avenue, Newington, CT, has a requirement for a firm fixed price contract to provide engineering and design services to include site investigation, development of complete drawings, specifications, cost estimates, and construction period services for Project 689A4-23-123, Newington Energy Center (Replace Boiler and Chiller). The VA Newington CT Campus currently has (3) water tube boilers, one (1) Zurn Industries and two (2) Bigelow Company, all of which are past the useful life expectancy of approximately 40 years and require replacement. boilers installed in 1981 that all contain a capacity of 40,000 IBS/HR. The useful life expectancy is estimated at about 40 years. The current capacity of first boiler is about 12 thousand IBS/HR and other two boiler each current capacity is 20 thousand LBS/HR. The boiler burners installed in 1995 are not capable of seamless fuel firing transition (natural gas to No. 2 oil) and require tuning by a boiler technician when changing fuel sources. Reports estimate that the Boiler and the heating distribution systems are beyond their useful life and that though some changes, modifications and upgrades are needed. The primary switchgear in B168 supplies power to all facility buildings. Underground conduits are used to connect distribution feeders from the switchgear to the various building locations. Multiple 22.8kv/480V transformer are located adjacent to building 2W, 2E and 2C to serve electric load. Plant electrical power/distribution to be assessed and modified as requested. Additionally, the chiller plant with variable flow secondary chilled water pumping throughout building 2 and part of building 1. The existing 500-ton Chiller plant was built in 1995 which are beyond their expected useful service life and need replacement. Design consideration/modification as requested. The design shall conform to all VA requirements outlined in the FGI Guidelines for Design and Construction of Hospitals, Facilities Guideline Institute (FGI), ADA, Joint Commission Accreditation Standards, ANSI, SMACNA, IBC, NEC, NFPA as well all requirements of the VA design manuals posted by discipline in the VA Technical Information Library This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has SBA small business size standard of $22.5 million in average revenue. See attached Statement of Work for complete details. B. CONTRACT INFORMATION: The Magnitude of Construction is between $50,000,000 and $100,000,000. This acquisition is a Total Set-Aside for Service-Disabled Veteran Owned Small Business (SDVOSB) in accordance with VAAR 852.219-10 with NAICS Code 541330. Any subsequent award will require the firm to be registered in System for Award Management (SAM www.sam.gov) and the VETBIZ Vendor Information Pages (https://www.vip.vetbiz.va.gov/) or the SBA VetCert Page (Veteran contracting assistance programs (sba.gov)); whichever is active at the time of award. SDVOSB/VOSB firms need to be registered with the applicable NAICS Code of 541330 at the time SF330 s are submitted. Prospective firms are reminded they must certify that in accordance with VAAR 852.219-77, VA Notice of Limitations on Subcontracting-Certificate of Compliance for Services and Construction, in the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not VIP-listed SDVOSBs as set forth in 852.219-10. Any work that a similarly situated VIP-listed subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. SF330 packages shall address how each firm anticipates meeting these criteria. This requirement is in accordance with the Selection of Architects and Engineers as implemented in Subpart 36.6 of the Federal Acquisition Regulation and Subpart M836.602-1 of the VA Acquisition Manual. All submissions will be evaluated in accordance with the evaluation criteria. A "short list" of the three to four most highly rated firms after initial source selection will be chosen for discussions through interview presentations, format to be determined by the Contracting Officer. The most highly rated firm at the conclusion of the interview process will be invited to submit a proposal in anticipation of a contract award. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract because of this announcement. Respondents are put on notice that firm(s) selected by the Selection Authority will be required to submit a Fixed Price Rate Proposal on the VA Form 6298 to include labor, overhead, profit, and other costs for this project for negotiation by the Contracting Officer prior to contract award. The negotiated agreement will be incorporated into the resulting contract. C. THIS IS NOT A REQUEST FOR PROPOSAL: This is a request for SF 330's Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. No material will be issued and no solicitation package or bidder/plan holder list will be issued. D. PROJECT INFORMATION: Provide Engineering services to develop a complete design package to include drawings, specifications, cost estimates, and construction period administration services associated with Project 689A4-23-123, Newington Energy Center. The attached statement of work for this project provides competed details of the requirements of this project. E. EVALUATION SELECTION CRITERIA: Each respondent s SF 330 submittal package will be evaluated in accordance with FAR 36.6 procedures. The selection criteria, in descending order of importance will be as follows: 1. Specialized Experience and Technical Competence 2. Professional Qualifications 3. Past Performance 4. Experience in Construction Period Services 5. Geographic Location 6. Capacity 7. Commitment to the use of SDVOSB, VOSB and SB as Subcontractors F. SELECTION CRITERIA DESCRIPTIONS: The selection criteria descriptions (1 through 7) are provided below. Specialized Experience and Technical Competence: The Engineering firm shall demonstrate recent specialized experience and technical competence in projects for health care facilities (to include joint ventures), including, where appropriate, recent experience in energy conservation, pollution prevention, waste reduction and the use of recovered materials. This factor evaluates the amount of experience the Engineering firm has in designing similar types of boiler and chiller replacement projects related to healthcare facilities and evaluating their technical competence in this type of project. Submitting firms shall provide a detailed narrative of up to 5 (maximum) and no less than 3 (minimum) relevant projects completed within the last 5 years, which best illustrate overall team experience relevant to this project scope. List projects that demonstrate the teams experience with projects of similar size and scope to those to be performed under this requirement. The specialized experience should demonstrate examples of removal of an existing boiler distribution system and installation of new boilers while maintaining the required boiler capacity as well as chiller plant replacement where temporary systems are installed to maintain redundancy at a healthcare facility. Higher ratings will be provided to firms who demonstrate experience at the VA or in a hospital environment. Professional Qualifications Necessary for Satisfactory Performance of Required Services: The Engineering firm will be evaluated according to their ability to demonstrate the education, training, registration, overall and relevant experience, and longevity with the firm of key management and technical personnel as is normally expected of a company actively providing the required services and shall have demonstrated experience to perform a project such as this within a VA Medical Center or hospital environment. Firms shall provide brief resumes of proposed team members who will specifically serve as the project managers and designers of record, as well as of other relevant team members or subcontractor team members who will perform technical tasks under this contract. Subcontractor team member resumes shall indicate their record of working together with the prime contractor. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline, and this must be shown on their resume. Each resume shall include a minimum of three (3) specific completed projects that best illustrate the individual team members experience in their technical field relevant to this project scope. Past Performance: The Engineering firm shall submit a minimum of three and maximum of five (5) past performance evaluations on recent projects relevant to the one being procured under this notice. Firms will be evaluated for past performance on recent and relevant contracts with Government agencies (emphasis on VA work) and private industry in terms of cost control, professional performance, general management, cooperativeness, quality of work, compliance with performance schedule and a record of significant claims against the firm due to improper or incomplete engineering services (references required). Recency is defined as performance occurring within five (5) years of the date of this Notice, except that ongoing projects must have begun no less than one (1) year prior to the issuance of this Notice. Relevancy is defined as performance of work on projects that are similar in scope to the type of project anticipated under the resultant contract. Respondents with no previous past performance shall so state when addressing the selection criteria. Documentation supplied should detail firms ability to work with government entities and design standards or similar relevant experience with other entities. Provide a copy of all performance evaluations (Engineering Services) issued for government contracts (as applicable). For Non-Federal contracts, provide facility owner documentation of the firms performance issued on that contract. If known documentation exists, so state. Provide accessible owner points of contact: name, title, address, telephone number, e-mail, and fax number and provide copies of awards and letters of appreciation/recommendation as desired. If there is no CPARS data available, Past Performance Questionnaires (PPQs) will be accepted. Please utilize the attached PPQ document. NOTE: We recommend you contact every reference listed and let them know we may contact them for information. Their timely replies would be appreciated. Experience in Construction Period Services: Respondents must provide one recent project and provide a narrative on how the Engineering firm incorporated the following into their project: Professional field inspections during the construction period Review of construction submittals Support in answering requests for information during the construction period Support of construction contract changes to include drafting statements of work and cost estimates Any project provided in addition to the one will not be evaluated as part of this criteria. Geographic Location: The Engineering Firm must demonstrate that it has general knowledge of the locality of the project, location in the general geographical area of the project and knowledge of the locality to include specific knowledge of certain local conditions or project site features such as: geological features climate conditions local construction methods construction firms and trades labor availability permit requirements local laws and regulations Location of the firm is measured by the driving distance between the Offeror s principal business location and the VA CTHCS Newington Campus, 555 Willard Avenue, Newington, CT. Determination of the mileage will be based on Google Maps (https//www.google.com/maps/dir/) Capacity: The Engineering Firm shall show current and projected workload within the firm overall and for the specific team members. Documentation supplied shall support that the firm has the capacity to accomplish the work in the required time. A signed statement shall be provided stating that the firm acknowledges that prior to award of the contract, they are required to notify the Government of any changes in their capacity that could limit their ability to perform the work within the required time. Commitment to the use of SDVOSB, VOSB, and other Small Businesses as Subcontractors: Respondents must provide a narrative on how they will commit to the use of Service-Disabled Veteran-Owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Prospective firms are reminded they must certify in accordance with VAAR 852.219-77, VA Notice of Limitations on Subcontracting-Certificate of Compliance for Services and Construction. This certification shall be included in any resultant contract. G. QUESTIONS AND COMMENTS: a. Questions and comments regarding this notice must be submitted by email only to the Contract Specialist, Judith Ruggiero at Judith.ruggiero@va.gov by Monday, January 23, 2023, at 1:00 pm EST. b. Oral questions will not be answered. c. The deadline for questions is Friday, February 10, 2023, at 4:00PM EST. H. SF 330 SUBMITTAL PACKAGE PAGE INSTRUCTIONS: a. SF 330 submittal packages shall be submitted no later than 1:00PM EST on Wednesday, February 8, 2023. Respondents are responsible for ensuring SF 330 submittal packages, any revisions, and modifications are submitted by this time. b. Qualified Engineering firms are required to submit ONE (1) electronic copy via email to Judith.ruggiero@va.gov. Subject line to Read : SF330 Project 689A4-23-123, Newington Energy Center. If file size exceeds 7MB then firms are required to send multiple emails with a sequence stating, Email 1 of __ . SF 330 forms are available on-line at: http://www.gsa.gov/portal/forms/type/SF c. Submission of information incorporated by reference is not allowed. d. Prospective firms shall address all selection criteria factors within their submitted SF 330 package. e. Submissions are limited to 65 pages. i. Absolutely no photographs shall be submitted. ii. Title pages and tables of contents, if applicable, are excluded from the page count limitation. iii. Pages submitted more than the limitations specified in this Notice will not be evaluated by NCO 1. f. Telephone or Fax inquiries will not be accepted. I. SF 330 PACKAGE CONTENTS: a. The SF 330 submittal packages shall consist of a completed SF 330, specific information addressing each of the seven (7) selection criteria described in this Notice. b. Respondents are required to meet all requirements in addition to those identified as selection criteria. c. SF 330 submittal packages not consistent with the requirements and selection criteria of this Notice may be determined unacceptable and removed from consideration. d. Any SF 330 submittal package, modification, or revision, that is received after the exact time specified for receipt is late and will not be considered unless it is received before award is made, the contracting officer determines that accepting the late submittal would not unduly delay the acquisition; and there is acceptable evidence to establish that it was received at NCO 1 installation designated for receipt of submittal packages and was under NCO 1 s control prior to the time set for receipt of submittal packages; or it was the only submittal package received. J. SF 330 PACKAGE PREPARATION: a. Electronic copy shall be in searchable PDF format of the SF 330. b. A cover sheet should be included, clearly marked with the Respondent's name, complete address with 9 digit zip code, phone number, e-mail address, DUNs number and Unique Entity Identifier, date of response, title, and Notice identification. c. Information not provided elsewhere in the SF 330 submittal package shall not be incorporated by reference. d. A table of contents shall be provided for ready reference to sections and figures. e. SF 330 submittal packages shall be consistent with the following structure and formatted accordingly: SF 330 PART I CONTRACT SPECIFIC QUALIFICATIONS 1. Sections A through D 2. Section E 3. Section F 4. Section G 5. Section H 6. Section I 7. Other additional information and attachments SF 330 PART II GENERAL QUALIFICATIONS (Note: Respondents shall clearly label additional information and attachments). K. FAR, VAAR, and VAAM: The FAR and VAAR citations referenced in this Special Notice can be accessed via the following internet links: FAR https://www.acquisition.gov/ VAAR https://www.va.gov/oal/library/vaar/index.asp VAAM https://www.va.gov/oal/library/vaam/ END OF SPECIAL NOTICE
Award Overview
Award Number
36C24123C0100
Award Amount (SAM.gov award notice)
$948.4K
Award Date
Sep 19, 2023
Awardee
Awardee UEI
S4QMN9YLJ866
Awardee CAGE Code
59TD4
Original Solicitation
Notice ID: 55f71ab472c24920a740a97b6bb44915
Posted Date: Sep 28, 2023
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $631.4KSigned Nov 9, 2026
- $927.3KSigned Nov 5, 2026
- $1.1MSigned Oct 13, 2026
- $3.0MSigned Sep 29, 2026
- $231.3KSigned Sep 25, 2026
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24123R0057- Awarded
This opportunity has been awarded.
- 2×Special NoticeJan 11, 2023
C1NB--689A4-23-123, AE Replace Boiler Plant and Chiller Plant Request for SF330s
- AwardedCurrentSep 28, 2023
C1NB--689A4-23-123, AE Replace Boiler Plant and Chiller Plant
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Introduction Network Contracting Office 1 (NCO 1), supporting VA New England Healthcare System (VISN 1), is seeking potential sources for an upcoming requirement for Architect and Engineering Services as described in the attached statement of work. THIS NOTICE IS NOT A REQUEST FOR QUALIFICATION STATEMENTS (SF330). This notice is a market research tool and has not been set-aside for any small business category, but the notice is issued to determine appropriate set-aside categories. Responses to this notice, in conjunction with other Government market research resources, will be used by the contracting officer to determine the applicable socio-economic set-aside for the procurement. Failure to respond to this notice will not impact consideration of architect and engineer firms (or joint ventures) which otherwise meet set-aside requirements and submit responses to the follow-up public announcement. Once the appropriate set-aside is determined, a separate public announcement requesting qualification statements (SF330s) will be publicized on Contract Opportunities in accordance with 40 U.S. Code § 1101 and FAR 36.102. General Project Description and NAICS Synopsis of required services (See attachment for full statement of work): provide Architect/Engineer (AE) services to evaluate existing conditions, propose corrective measures, and design a construction project at the VA Maine Health Care System (Togus) in accordance with this scope of work. Scope will include Type A services only with design complete to 35%. AE Part I Investigative Services/Schematic Design/Other Related Services shall include site visits, field investigation, studies and user interviews to prepare drawings, and cost estimates for all facets of work and disciplines/trades to repair Chiller 3 to a condition where it will operate as designed. Design should also include fixes for the reported cooling and oil leaks. This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has a SBA size standard of $22.5 million in average revenue. Information Sought The Government requests a letter of interest (or similar document) with responses to the following: 1. State your firm name (as it appears in SAM.gov), Unique Entity Identifier (UEI) number, and socio-economic status of the firm (i.e. verified SDVOSB, WOSB, SB, large business). 2. Provide a brief narrative on the firm s experience, providing services similar to those described in the attached statement of work. 3. What would be the expected make-up of the firm s team in terms of socio-economic categories and estimated percentage of work to be completed by your firm and each subcontractor? If the procurement is set-aside for any category of small business, generally fifty percent of more of the work would need to be performed by the contractor or a similarly situated subcontractor in terms of percentage of cost. For instance, if set-aside for service-disabled veteran-owned small business (SDVOSB), 50% or more of the contract would need to be performed by verified SDVOSBs no other small business categories would count towards the percentage. If set-aside for small business, 50% of the contract would be required to be performed by small businesses which would include performance by a verified SDVOSB because they are also a small business. If the procurement is not set-aside and reaches certain dollar thresholds, the Government would negotiate an acceptable subcontracting plan to utilize small business concerns. 4. A brief statement of overall interest in the project and capability of performing the work in conjunction with ongoing projects. 5. Any additional capabilities statements or other documentation that you feel will assist the Government in performing market research and determining the appropriate set-aside. Submission Instructions Interested parties are requested to submit the requested information not later than November 20, 2026, to Diane C. Davis via email to diane.davis2@va.gov. Please include 36C24127R0009 Sources Sought Response in the title of the email. the response burden to this notice is expected to be light; lengthy responses are not expected but no maximum page count is assigned. Please keep responses below 7MB or send multiple emails appending to the email subject 1 of n as appropriate. Please contact Diane Davis at the email address above with any questions. Attachments | - | Market Research | 11/20/2026 |
SPECIAL NOTICE FOR QUALIFICATIONS (SF 330) NAICS Code: 541330 Engineering Services (Small Business size standard $25.5M) A. INTRODUCTION: The VA Central Western Massachusetts Healthcare System (CWM HCS) plans to build and install a new elevator tower at Building 25 on the Leeds Campus. This project will correct a FCA deficiency. Provide all professional architectural and engineering (A/E) Part One Services (also known as Design Phase Type A & Type B Services) necessary to develop complete drawings, specifications, and cost estimates associated with building a new elevator tower at Building 25 and Part Two Services (also known as Construction Period Services Type C). The intent of this project includes but is not limited to: Evaluate existing elevator pit slab for buildings 1, 2, 3, 4, 5, 6, 7, 8, 12, 16, 20, and 26 and design an elevator pit sump pump with oil interceptor. Design plumbing of oil water separator to sanitary sewer. See acceptable conceptual design attached. This conceptual design shall be validated. This shall be used to minimize and inform design efforts. Identify and address any issues or conflicts as necessary. If the elevator tower appearance is different than the conceptual design, conduct a Section 106 Historical Submission Report for VA to file with Massachusetts State Historical Preservation Office, by a Professional Historic Preservation Consultant. Existing report will be made available to the highest rated A/E firm. Conduct code compliance reviews (NFPA, ABAAS, VA Design Manuals, etc.) and integrate findings into design for compliance. Where conflicts exist between VA adopted codes and standards and the documents on the TIL, the A/E shall bring this to the attention of the VA. The resolution of the conflict shall be made by the authority having jurisdiction for VA to ensure consistency department wide. The A/E shall provide all services required to prepare documents and reports consistent with the VA s project team goals as prioritized during preliminary project meetings, field surveys and studies. The A/E shall determine existing conditions, severity of deficiencies, if any previous deficiencies have been corrected and to identify any conditions which may have previously been unreported. Cost estimates shall be prepared to reflect the cost of replacing the component in a standalone project (i.e., not as part of another project) and all costs including but not limited to asbestos removal if required, special field conditions and/or temporary equipment needed during the construction. Provide a Qualified Elevator Inspector during Construction Services to certify elevator. Also provide Part Two A/E Services (also known as Construction Period Services Type C) A/E Part Two Services of this design project (also known as Construction Period Services) includes responding to construction contractor Requests For Information (RFIs) during the solicitation (solicitation support) and construction phases of the construction project, attendance at post-award and commissioning kick off construction project conferences, review of construction material submittals and shop drawings, attendance at weekly teleconference construction meetings, approximately 1 site visits per month during active construction (both scheduled and emergent) to ensure compliance with the design drawings and specifications, preparation of site visit reports, coordination with project commissioning requirements/QEI inspection, review of any construction project modifications for cost and technical acceptability, attendance and participation during the pre-final inspection and final acceptance inspection, preparation of the punch list and preparation of record drawings of the completed construction project based on the construction contractor s as-built drawings. The A/E shall prepare a submittal log to be utilized by the VA during construction period services and maintain a RFI log. B. CONTRACT INFORMATION: The VA Medical Center Central Western Massachusetts located in Leeds, MA has a requirement for a Firm Fixed Price contract to provide professional A/E services for the 631-21-011 Building 25 Elevator Design project. The magnitude of construction is between $2,000,000 and $5,000,000. Prospective firms are reminded they must certify that in accordance with VAAR 852.219-75, VA Notice of Limitations on Subcontracting-Certificate of Compliance for Services and Construction (JAN 2023) (DEVIATION), in the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219- 74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. SF330 packages shall address how each firm anticipates meeting this criteria. This requirement is in accordance with the Selection of Architects and Engineers as implemented in Subpart 36.202 of the RFO and Subpart M836.102 of the VA Procurement Manual. All submissions will be evaluated in accordance with the evaluation criteria. A "short list" of the three most highly rated after initial source selection will be chosen for negotiations of a contract award. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Respondents are put on notice that firm(s) selected by the Selection Authority will be required to submit a Fixed Price Proposal on the VA Form 6298 to include labor, overhead, profit, and other costs for this project for negotiation by the Contracting Officer prior to contract award. The negotiated agreement will be incorporated into the resulting contract. C. THIS IS NOT A REQUEST FOR PROPOSAL: This is a request for SF 330s only. Any requests for a solicitation will not receive a response. No material will be issued, and no solicitation package or bidder/plan holder list will be issued. D. PROJECT INFORMATION: Provide all professional architectural and engineering (A/E) services necessary to develop complete drawings, specifications, cost estimates, construction schedules, project phasing, investigations, site visits and construction period services associated with the 631-21-011 Building 25 Elevator Design at the VAMC Central Western Massachusetts HCS, Leeds, MA 01053. E. EVALUATION SELECTION CRITERIA: Each respondent s SF 330 submittal package will be evaluated in accordance with RFO 36.202 procedures. The selection criteria, in descending order of importance will be as follows: 1. Specialized Experience/Technical Competence 2. Professional Qualifications 3. Past Performance F. SELECTION CRITERIA DESCRIPTIONS: The selection criteria descriptions (1 through 3) are provided below in descending order of importance. Specialized Experience/Technical Competence Provide five (5) recent and relevant projects related to the Statement of Work with a similar magnitude (magnitude of construction for the design is between $2,000,000 and $5,000,000) that demonstrates experience with VA Design Requirements or equivalent with significant existing condition renovation. A minimum of three (3) projects should be for comprehensive designs of new elevator builds. Projects should detail the design manual requirements and required equipment for effective operation of an elevator, HVAC, and other necessary mechanical systems. Projects should also detail working with end users and reviewing manufacturer equipment. A minimum of two (2) projects should be for comprehensive designs for exterior historical renovations that took place in the Commonwealth of Massachusetts. These projects should detail the applicable regulation governing historical reviews, explain the process, and demonstrate an understanding of and adherence to the requirements. Recency is defined as performance occurring within five (5) years of the date of this notice. If current projects are provided, these projects must have begun one (1) year prior to the issuance of this notice. Projects that have not been in performance for one (1) year will not be considered. Relevancy is defined as performance of work on projects that are similar in scope to the type of project anticipated under the resultant contract. This factor evaluates the amount of experience and technical competence the firm has in designing similar types of projects. Respondents must provide five (5) recent and relevant projects; any project provided in addition to the five are not required and will not be considered if provided. The following information is required for all projects provided under this criteria any material missing the following requested information will be assessed a deficiency: Contract/Task Order Number Project Title Location Prime Firm with % of self-performed work Subconsultants Start and Completion dates If project is not yet complete, identify the current phase/stage of the project. Fully completed projects will carry more weight than projects still in design Cost of Construction Description of the project in sufficient detail and clearly document how it is relevant to the scope of this project Professional Qualifications Professional qualifications necessary for satisfactory performance of required services. The A/E firm will be evaluated according to their ability to demonstrate the following: education; training; registration; overall and relevant experience; and longevity with the firm of key management and technical personnel. Firms shall provide brief resumes of proposed team members who will specifically serve as the project managers and designers of record, as well as of other relevant team members or subcontractor team members who will perform technical tasks under this contract. Subcontractor team member resumes shall indicate their record of working together with the prime contractor. The minimum required disciplines are Architecture, Structural, Mechanical (HVAC and Plumbing), Electrical, Fire Protection, Interior Design, Elevator Consultant, Cost Estimator. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline, and this must be shown on their resume. Each resume shall include a minimum of three (3) specific completed projects that best illustrate the individual team members experience in their technical field relevant to this project scope; any project provided in addition to the three (3) will not be evaluated as part of this criteria. Past Performance Firms will be evaluated for past performance on recent and relevant contracts with Government agencies (emphasis on VA work) and private industry in terms of cost control, professional performance, general management, cooperativeness, quality of work, compliance with performance schedule, and a record of significant claims against the firm due to improper or incomplete A/E services (references required). The evaluation may consider Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. Past Performance information on contracts not listed by the offeror may also be evaluated. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. While the Government may elect to consider data obtained from other sources, the burden of providing current, accurate, and complete Past Performance information rests with the offeror. The Government reserves the rights to obtain and evaluate Past Performance information from any source it deems appropriate. Respondents with no previous past performance shall state so when addressing the selection criteria. Documentation supplied should detail firms ability to work with government entities and design standards or similar relevant experience with other entities. The following information is required for evaluation of past performance: The A/E firm shall submit past performance evaluations (from CPARS if experience was on a Government contract) for projects provided under Evaluation Criteria 1, Specialized Experience/Technical Competence. In addition to the past performance evaluations the firm shall provide owner points of contact for each project listed to include name, title, telephone number, e-mail, contract number, project name, project description, and start and completion dates. Recency is defined as performance occurring within five (5) years of the date of this notice. If current projects are provided, these projects must have begun one (1) year prior to the issuance of this notice. Projects that have not been in performance for one (1) year will not be considered. Relevancy is defined as performance of work on projects that are similar in scope to the type of project anticipated under the resultant contract. If there is no CPARS data available, Past Performance Questionnaires (PPQs) will be accepted. Please utilize the attached PPQ document. PPQs shall be submitted to the CO not later than the closing date for receipt of the SF 330s. Email PPQs to Brian.Kelly@va.gov. The subject line shall state 36C24126Q0518 Past Performance for (Name of Company) Project 631-21-011 . NOTE: A/E Firms must not review the Past Performance Questionnaire prior to submission. They must be submitted by the client/evaluator directly to the CO. Firms should follow up and encourage references to get the questionnaires to the CO in a timely manner. Do not include copies of the letters or questionnaires in the SF 330 package. Note: We recommend you contact every reference listed and let them know we may contact them for information. Their timely replies would be appreciated. G. QUESTIONS AND COMMENTS: a. Questions and comments regarding this notice must be submitted by email only to the Contracting Officer, Brian Kelly at Brian.Kelly@va.gov. b. Oral questions will not be answered. c. The deadline for questions is November 20, 2026, at 1:00PM EST. H. SF 330 SUBMITTAL PACKAGE PAGE INSTRUCTIONS: a. SF 330 submittal packages, including Past Performance Questionnaires, shall be submitted no later than 4:00PM EST on December 7, 2026. Respondents are responsible for ensuring SF330 submittal packages, any revisions, and modifications are submitted by this time. b. Qualified A/E firms are required to submit ONE (1) electronic copy via email to Brian Kelly at Brian.Kelly@va.gov. If the file is too large to send via email, the offeror may send multiple emails with multiple files (See Self-Service Microsoft Exchange: Email Sending Limits (va.gov) regarding file size). SF 330 forms are available at: https://www.gsa.gov/forms#SF c. Submission of information incorporated by reference is not allowed. d. Prospective firms shall address all selection criteria factors within their submitted SF 330 package. e. Submissions are limited to 65 pages. i. Absolutely no photographs shall be submitted. ii. Title pages and tables of contents, if applicable, are excluded from the page count limitation. iii. Pages submitted in excess of the limitations specified in this Notice will not be evaluated by NCO 1. f. Telephone or fax inquiries will not be accepted. I. SF 330 PACKAGE CONTENTS: a. The SF 330 submittal packages shall consist of a completed SF 330, specific information addressing each of the seven selection criteria described in this Notice. b. Respondents are required to meet all requirements in addition to those identified as selection criteria. c. SF 330 submittal packages not consistent with the requirements and selection criteria of this notice may be determined unacceptable and removed from consideration. d. Any SF 330 submittal package, modification, or revision, that is received after the exact time specified for receipt is late and will not be considered unless the contracting officer determines that accepting the late submittal would not unduly delay the acquisition; and there is acceptable evidence to establish that it was received at NCO 1 installation designated for receipt of submittal packages and was under NCO 1 s control prior to the time set for receipt of submittal packages; or it was the only submittal package received. J. SF 330 PACKAGE PREPARATION: a. Qualified A/E firms are required to submit ONE (1) electronic copy via email to Brian Kelly at Brian.kelly@va.gov. SF 330 forms are available online at: https://www.gsa.gov/forms#SF. b. Electronic copy shall be in searchable PDF format of the SF 330. c. A cover sheet should be included, clearly marked with the Respondent's name, complete address with 9-digit zip code, phone number, e-mail address, UEI number, date of response, title and notice identification. d. A table of contents shall be provided for ready reference to sections and figures. e. SF 330 submittal packages shall be consistent with the following structure and formatted accordingly: SF 330 PART I CONTRACT SPECIFIC QUALIFICATIONS 1. Sections A through D 2. Section E 3. Section F 4. Section G 5. Section H 6. Section I 7. Other additional information and attachments SF 330 PART II GENERAL QUALIFICATIONS (Note: Respondents shall clearly label additional information and attachments). K. FAR and VAAR: The FAR, VAAR, and VAAM citations referenced in this Special Notice can be accessed via the following links: FAR https://www.acquisition.gov/ VAAR https://www.va.gov/oal/library/vaar/index.asp VAAM https://www.va.gov/oal/library/vaam/ | - | Special Notice | 12/07/2026 |
| - | Awarded | Open | |
Modification 2 to Presolicitation Notice 36C25527R0013 This modification provides answers to RFIs received and revised the evaluation criteria to be used for this project. RFIs Received for Project # 657A5-24-108, Replace Medium Voltage Feeder 3 and Transformers 1. Factor 4 Past Performance / Section F Project Eligibility  The solicitation states that projects submitted for past performance consideration must have completed both design and construction, and that projects not constructed will not be considered. Would the VA consider accepting relevant electrical infrastructure studies or assessments in Section F, particularly those involving medium-voltage distribution systems and feeder evaluations, that demonstrate directly applicable technical expertise but did not result in construction? We prefer to keep it as projects that were designed AND constructed. Since this is a construction project and not a study, we want projects that have been finished to be used for past performance criteria.  2. Factor 2 Specialized Experience and Technical Competence / Laboratory Requirements  Factor 2 references the firm's technical capabilities in design quality management procedures, CADD/BIM, equipment resources, and laboratory requirements. Given that the project scope primarily involves medium-voltage electrical feeder and transformer replacements, could the VA clarify the applicability of laboratory requirements to this project? We respectfully request that this criterion be removed from the evaluation requirements, as it does not appear directly relevant to the stated scope of work. Laboratory requirements were deleted. Please see revised evaluation criteria below.  3. Request for Submission Deadline Extension Given the technical scope of the project and the level of detail required to address the evaluation criteria, we respectfully request a one-week extension of the SF330 submission deadline, from November 10, 2026, to November 17, 2026. This additional time would allow interested firms to prepare comprehensive qualifications packages that fully address the solicitation requirements. SF330 submission due date extended from 11/10/2026 to 11/172026. End of RFIs. | - | Pre-Solicitation | 11/17/2026 |
NAICS is 541330 - Engineering Services and small business size standard of $25.5. ___________________________________________________________________________________________________ The purpose of this announcement is for market research only. No solicitation will be posted at this time. The Department of Veterans Affairs NCO 15 Contracting Office and John Cochran (JC) VA Medical Center, 915 N Grand Blvd, St. Louis MO. 63106, seeks capabilities information on interested vendors to provide AE Services for design completion for project. The responding interested offerors are requested to provide procurement capabilities from licensed professional architects and engineers currently registered in the state of Missouri or in a state of which Missouri has recognized the engineering license. The specific disciplines which will be evaluated are Architects, Civil Engineer, Mechanical Engineers, Electrical Engineers, Structural Engineers, Industrial Hygienists, Estimators, CAD operators, Project Managers, LEED Consultant, Fire Protection Engineer, and Interior Designer at the medical center. The North American Industry Classification system (NAICS) code for this acquisition is 541330 - Engineering Services and small business size standard of $25.5. PSC: C1DA Magnitude of Construction Project between $500,000 and $1,000,000. Project Intent: A/E Firm shall provide all necessary design and construction period of services for subject project. The VA St. Louis Health Care System, John Cochran Division, will prepare existing space for a new Interventional Radiology equipment in Room A261. This project will renovate the area of the current equipment and reconfigure the area to properly utilize all of the features of the new unit. Work includes demolition of walls, ceilings, flooring and utilities. Existing exam, control and equipment room will be reconfigured to support new equipment needs. New construction includes walls, ceilings, flooring, doors, lead shielding, lights, power, data, phone, systems, new AHU system to support HVAC design guidelines, to allow the vendor to install the new equipment. Project will require assessment of existing lead shielding. Scope to focus on refreshing space instead of a full reconstruction. Responses must be received by 6:00 PM CST on November 05, 2025, via e-mail to the Contracting Officer at Gislaine.Dorvil@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: Project 657-27-207JC Prepare Site for Interventional Radiology Equipment Room A261" IN THE SUBJECT LINE. Respondents will not be contacted regarding their submission or information gathered because of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov/. The Contract Opportunities website is the only official site to obtain these documents. | - | Market Research | 11/05/2026 |
Additional Details
Solicitation Number
36C24123R0057
Archive Date
Oct 28, 2023
Office Address
TOGUS, ME, 04330