Notice ID: d06200e86a154e25b054ad7dc8d36748Special Notice
C213--650-22-111 Med Gas Survey, Assessment, and Analysis
Archived on May 18, 2023. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:30 PM UTC−04:00
- Posted
- February 24, 2023
- Notice type
- Special Notice
- NAICS
- 541330: Engineering Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241)
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24123R0058
- Notice ID
- d06200e86a154e25b054ad7dc8d36748
Description
Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of SF330 SPECIAL NOTICE FOR QUALIFICATIONS NAICS Code: 541330 Engineering Services (Small Business size standard $22.5 million dollars) PROCUREMENT METHOD: Full and Open Competition (unrestricted) PROJECT TITLE: 650-22-111 Medical Gas Survey, Assessment, and Analysis INTRODUCTION: This is not a Request for Proposal (RFP): The VA is not requesting cost or pricing information at this time. The VA Medical Center (VAMC) located at Providence, RI 02908 has a requirement for a Firm-Fixed Price contract to obtain Architect/Engineer (A/E) Professional Services for the A/E Firm to perform a detailed Investigative Survey and Assessment of the VA Medical Gas Systems, and to document results of the Investigative Study. Investigative Survey Services will take place in Building 1, located on the Providence, RI Veterans Affairs Medical Center (VAMC). No Design or Construction services are associated with this project. B. GENERAL PROJECT OVERVIEW: The general scope of work for this project will require Firm to provide Architect/Engineer (A/E) professional services to perform a detailed Investigative Survey and Assessment of the VA Medical Gas Systems, and to document results of the Investigative Study. Investigative Survey Services will take place in Building 1, located on the Providence, RI Veterans Affairs Medical Center (VAMC). No Design or Construction services are associated with this project. The Investigative Survey and Assessment shall be summarized in a detailed survey report and in an analysis report describing system problems and solutions with recommendations and cost estimates, and record drawings shall be provided to the VAMC. The Investigative Survey, Assessment, and Documentation shall include the following components: Oxygen, Medical Air, Nitrous oxide, Nitrogen, Medical vacuum, anesthesia exhaust, and related systems. Also included in Assessment and Analysis are: bulk systems, manifolds, compressors, dryers, filters, regulators, vacuum pumps, air treating systems, zone valves, outlets, master alarms, and area and system alarms and some cabling as appropriate. System components located external of the building shall also be included in the survey. Refer to enclose Scope of Work for full details of Survey Requirements. MAGNITUDE OF CONSTRUCTION: N/A. Construction Period Services are not included in this project PROCUREMENT METHOD: In accordance with FAR subpart 6.102 (d) Other Competitive Procedures for Architect-Engineering contract, this project will be issued under a Full and Open Competition (unrestricted) basis. In accordance with FAR 52.204-7, System for Award Management (SAM), prospective Firm shall be registered in the SAM database. NAICS Code 541330 will be used for this project. Any subsequent award will require the firm to be registered on the System for Award Management (SAM) website accessible at https://sam.gov/content/home. The Government will not pay, nor reimburse, any costs associated with responding to this SF-330 Qualifications Notice. The Government is under no obligation to award a contract as a result of this announcement. Respondents are put on notice that firm(s) selected by the Selection Authority will be required to submit a Fixed Price Proposal to include labor, overhead, profit, and other costs for this project for negotiation by the Contracting Officer prior to contract award. The final negotiated agreement will be incorporated into the resulting VA contract. Each Firm shall address their method for meeting the Limitations on Subcontracting (if applicable). SELECTION CRITERIA: Each of the below five (5) evaluation criteria will be evaluated in accordance with FAR 36.6 procedures, and the selection criteria show below are listed in descending order of importance: Professional Qualifications (Resumes) Specialized Experience and Technical Competence Capacity Past Performance Commitment to the use of SDVOSB, VOSB, and other Small Businesses as Subcontractors SELECTION EVALUATION CRITERIA Each of the below Selection Criteria will be evaluated in accordance with FAR 36.6 procedures, and VAAR Subpart 836.6 Architect-Engineer Services; using Adjectival Ratings and Confidence Level Ratings. Criteria 1-3, and 5 will be evaluated using Adjectival Ratings, Criteria 4 will be evaluated using Confidence Level Ratings. The below selection criteria are shown in descending order of importance as follows: PROFESSIONAL QUALIFICATIONS: Professional Qualifications are necessary for satisfactory performance of required Scope of Work services. At a minimum, responding Firms must describe their specific professional qualifications, along with how many years of experience Firm has in providing survey, assessment, and analysis services on Medical Gas Systems. In addition to the above, each of the disciplines described below must have three (3) to five (5) years of experience within the specialty of Surveying, Assessing, and conducting Analysis for Medical Gasses and healthcare facilities (in accordance with the enclosed Scope of Work): Note: If Firm has a discipline that is named differently or that is interchangeable with the below disciplines, or that performs dual duties (e.g. PE and EE), then Firm must clearly describe differences. In addition to below required disciplines, Firm may also propose disciplines that they believe may be required to successfully perform work under this project. Certified Med Gas Inspector Mechanical Engineer Plumbing Engineer Electrical Engineer Use SF-330 to provide a resume (of 3 -5 pages) for each of the above disciplines, and other non-key personnel team members, and for regular subcontractor(s) who will perform services under the resultant contract. Clearly describe which personnel are key personnel, which personnel are non-key personnel, and which personnel works for subcontractor(s). Each resume for the proposed discipline shall include a minimum of three (3) projects that specifically align (in relevance) with the services described in the enclosed Scope of Work. Each resume must clearly describe how each proposed team member has the minimum education, training, experience, certification, and registrations in order to perform services described in the Scope of Work Requirements. Note: Key Personnel proposed for this project must be the same team members who will perform work under the resultant Contract. Prior to any substitution of key personnel, all key personnel substitutions must be approved in writing by the VA NCO 1 Contracting Officer. Evaluation: Each resume will be evaluated using an adjectival rating method, based on degree to which proposed resumes clearly and specifically demonstrate level of specialized experience in conducting Analysis of the Medical Gas Systems (as described in the enclosed SOW). Adjectival ratings will also be used to evaluate proposed personnel s minimum education, training, experience, certification, and registrations. Higher ratings may be provided to Firms personnel with more years of demonstrated experience with conducting Analysis of the Medical Gas Systems on VA hospitals, or other medical centers. SPECIALIZED EXPERIENCE AND TECHNICAL COMPETENCE: Use SF-330 to describe Firm s Specialized Experience and Technical Competence performing A/E survey services to Analysis of the Medical Gas Systems. Describe Firm s approach to developing CAD drawings and survey reports. Also describe anticipated system problems and solutions with recommendations and cost estimates, and detailed record drawings in AutoCAD. Specialized Experience and Technical Competence response must be detailed and specific to show how Firm has the specialized experience and technical competence to perform Scope of Work requirements and meet SOW Deliverables in an accurate and timely manner. Response must include a 3 to 5 (3 minimum, 5 maximum) Contracts or Projects that clearly demonstrate firm specialized experience for project the same as or similar to SOW requirements. Project must have been completed within the last three (3) to five (5) years Evaluation: Each response will be evaluated using an adjectival rating method, based on degree to which firm clearly described how their specialized experience and technical competence clearly and specifically demonstrates Firms ability to successfully perform Scope of Work requirements. Firms may also be evaluated according to projects submitted that indicate specialized experience and technical competence similar to the magnitude and scope of this project. A minimum of 3 projects and maximum of 5 projects are required that describe a firm s specialized experience and technical competence. A Firm may receive higher ratings for any projects beyond the minimum of 3 that also demonstrate Firm s specialized experience and technical competence (additional projects must still meet requirements). If more than 5 projects are submitted, only five will be evaluated. CAPACITY: Given your Firm s current workload and the availability of Firm s existing key personnel and other non-key personnel team members; describe your Firm s real-time capacity to successfully meet the Scope of Work services, to include meeting Deliverables Schedule in an accurate and timely manner. Also describe how your Firm will manage ongoing projects without those projects having an adverse impact on performing Scope of Work requirements for this project. Describe how your Firm typically handles capacity issues (briefly, but concisely describe firms staffing plan for keeping up with being awarded new work (i.e., plans to keep adequate number of staff onboard during workload expansion). Firms may use Joint Ventures or legally formed Partnership Agreements to perform work. If used for this project, firm must submit their JV or Partnership agreement with their SF330 submittal. Evaluation: Capacity will be evaluated using an Adjectival Rating Method, based on realism of firms existing capacity to meet SOW requirements, and how firm plans to maintain adequate staff for performing work for this project. PAST PERFORMANCE: Past performance is described as contracts and projects with Government agencies and private industry for recent and relevant contracts and projects in terms of cost control, quality of work, and compliance with performance schedules. Past performance submittals must be relevant projects similar in scope, size, and complexity with requirements described in the attached Scope of Work (projects can be from Government, State, and private experience). Recency is defined as performance occurring within 5 five years of the date of this Qualifications Notice, except that ongoing Contracts/Projects must have begun no less than one (1) year prior to the issuance of this Notice. Relevancy is defined as past performance of work on Contracts/Projects that are similar in scope and complexity to the type of Contracts/Project anticipated under the resultant contract. Each Firm must submit three (3) recent and relevant past performance projects with their SF 330 Qualifications package. At a minimum each past performance referenced must include the following information: Contract/task order number Project title Name of Prime Contractor and Subcontractors (if applicable) Contract/Project Start and completion date Contact information Any challenges faced during project and remedies/solutions. Dollar amount and Construction dollar amount (if applicable) Provide Contract numbers for up to three (3) Contractor Performance Assessment Reporting System (CPARS). This will enable the VA to run CPARS searches for relevant contracts. Evaluation: This factor will be evaluated using a Level of Confidence Rating method. The Government also reserves the right to use CPARS to evaluate Past Performance on previously awarded Federal Task Orders and any other information available. Verifying and evaluating Past Performance submittals may also include using additional resources such as CPARS, information provided by the firm, customer inquiries, Government databases, and publicly available sources. A minimum of 3 past performance projects are requested. A firm may receive higher ratings for any projects beyond the minimum of 3 that also demonstrate a firms recent and relevant past performance experience (additional projects must still meet requirements). If more than 5 projects are submitted, only five will be evaluated. COMMITMENT TO THE USE OF SDVOSB, VOSB, AND OTHER SMALL BUSINESSES AS SUBCONTRACTORS: Respondents must provide a narrative on how they will commit to the use of Service-Disabled Veteran-Owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Evaluation: Each response will be evaluated using an adjectival rating method, based on degree to which firm clearly described commitment to use SDVOSB, VOSB, and other Small Businesses as subcontractor. QUESTIONS (RFIs) DUE DATE: Deadline for submitting written RFI questions to the VA is by February 20, 2023, by 2:30 PM EST. All Questions/RFIs and comments regarding this notice must be submitted only in writing via email to pearl.wray@va.gov All questions and comments in response to this SF 330 Qualifications Notice must be submitted in writing only. Verbal telephone questions will not be accepted or answered. SF330 QUALIFICATIONS PACKAGE DUE DATE: The entire SF330 submittal packages, including Past Performance documents, and Small Business use shall be submitted to pearl.wray@va.gov by March 13, 2023 by 2:30 PM EST. All interested and qualified Firms are required to submit one (1) electronic copy of the entire SF330 Qualifications package via email to pearl.wray@va.gov. If file size exceeds 7 MB, then each Firm is required to send multiple emails, and please use email subject line to indicate how many emails are related to Firms total submittal (e.g., 1 of __, 2 of __, etc.). SUBMITTAL INSTRUCTIONS FOR SF330: Late responses are considered any SF 330 submittal that is submitted by the Firm, after the exact date and time outlined above under Section H. a. Any SF 330 submittal package, modification, or revision to the SF 330 package that is not received at the designated VA email address before or at the exact time specified above under Section H. a., may be deemed Late and may not be considered. Responding Firms must address all five (5) of the Selection Evaluation Criteria described within this SF 330 Qualifications Notice. A current SF 330 form is available on-line at: https://www.gsa.gov/forms-library/architect-engineer-qualifications Each Firm that responds to this SF 330 Notice is responsible for ensuring that the entire SF 330 package, to include any revisions, and modification information issued by the VA is submitted by the time shown above under Section H. a. When responding to each of the five (5) selection criteria, please be specific, clear, and descriptive with all response information (i.e., please do not merely state that information is incorporated by reference ). SF330 PACKAGE SUBMITTAL CONTENTS: Each responding Firm must use a current SF 330 Form to respond to the attached Scope of Work, and the most current SF 330 Form to address the requirements within this Notice. At a minimum, a complete SF330 package must include the following items: The entire SF330 package along with continuation pages (if more space is needed beyond space provided on the SF330 Form) is limited to fifty-five (55) pages. With the exception of the below bullet point items, pages that exceed the fifty-five (55) page limit may not be considered or evaluated by the Evaluation Panel. The following items are excluded from the fifty-five (50) page limitation: Signed Cover letter Resumes do not count against page limitation Past Performance submittals do not count against page limitations. Drawings may be submitted with SF 330 submittal, and do not count against total page limitation. Drawings should be substantive and must support other proposed SF330 information. Cover letter, at a minimum must include the following: Firm s Legal Name, and DBA (if applicable), and full physical address, can also include mailing address. Firm s SAM Unique Entity ID (UEI), and DUNS numbers. Response Date (date Firm s SF 330 is submitted to the VA). Number and Title of this Notice SF330 submittal packages must clearly and specifically address all five (5) Selection Criteria described in this Notice. Not fully addressing each of the 5 Selection Criteria may cause Firm s submittal to be deemed unacceptable or non-responsive. Complete all applicable Sections of both Part I and Part II of the SF 330 Form, and any other applicable sections of the SF330 form. Please use N/A if any sections of SF330 are not applicable (please do not leave any Sections blank). Responding Firms must clearly label/cross reference any supporting narrative information and attachments with their SF 330 submittal package. K. FAR and VAAR CITATIONS: The FAR and VAAR citations referenced in this Special Notice can be accessed via the following websites: FAR: https://www.acquisition.gov/browse/index/far VAAR: https://www.acquisition.gov/vaar A/E SCOPE OF WORK Project: 650-22-111 Medical Gas Survey, Assessment, and Analysis VA Medical Center Providence, RI 02908 1. PROJECT BACKGROUND: Provide Architect/Engineer (A/E) professional services to perform a detailed Investigative Survey and Assessment of the VA Medical Gas Systems, and to document results of the Investigative Study. Investigative Survey Services will take place in Building 1, located on the Providence, RI Veterans Affairs Medical Center (VAMC). No Design or Construction services are associated with this project. Services will include all labor, transportation, materials, apparatus, tools, equipment, and permits necessary to complete the detailed Investigative Survey, Assessment and Analysis to document results (in the form of CAD drawings and an analysis report) of the Investigative Survey. For project scale purposes, building 1 is approximately 400,000 GSF consisting of nine-floors and a basement. PROJECT SCOPE OF WORK: The Investigative Survey and Assessment shall be summarized in a detailed survey report and in an analysis report describing system problems and solutions with recommendations and cost estimates, and record drawings shall be provided to the VAMC. The Investigative Survey, Assessment, and Documentation shall include the following components: Oxygen, Medical Air, Nitrous oxide, Nitrogen, Medical vacuum, anesthesia exhaust, and related systems. Also included in Assessment and Analysis are: bulk systems, manifolds, compressors, dryers, filters, regulators, vacuum pumps, air treating systems, zone valves, outlets, master alarms, and area and system alarms and some cabling as appropriate. System components located external of the building shall also be included in the survey. The Medical Gas Survey services shall be conducted by a Certified Medical Gas Inspector (ASSE 6000 series certified). Technical services of a certified Medical Gas Inspector (ASSE 6000 series certified) and professional services of an architect/engineer are as follows: The A/E shall provide all project management for the project. The A/E shall coordinate work with the Providence VAMC Facilities Management Service team a minimum of two (2) weeks before proceeding with any work on VAMC property throughout the contract. Contact names and phone numbers will be provided upon contract award. The contractor must be badged and escorted at all times. Hospital personnel on-site on the patient wards must approve entrance and the conducting of any tests before proceeding. Some areas of the VAMC facility will require entrants to wear medical protective clothing, to be provided by the VA. The medical gas survey shall be conducted by a certified Medical Gas Inspector (ASSE 6000 series certified). The A/E shall provide a record set of colored drawings of all existing medical gases systems showing the geographic location, sizes, interconnectivity of all components in each system, and connections to building utilities. At a minimum, provide a cover sheet, a site plan, a floor plan of each building floor, and isometric details of major components (e.g., pump assemblies, storage tanks and manifolds). Also provide a functional schematic of each system that can be used for training and in an emergency. The VA will provide building floor plans in AutoCAD format to the A/E for use in preparing the record drawings. The A/E shall provide a detailed survey report enumerating the system components identified in the survey including mechanical and alarm systems. The report shall list all components by location (e.g., hospital floor and room) and manufacturer. It shall also contain a summary section showing the total number of each component found in the survey as well as a list of problems found by component. The report shall describe the system documentation that exists on site for each component and shall develop a document deficiencies list. The source manufacturer and address of missing documentation shall be listed so this documentation can be ordered by the VAMC. The A/E shall provide a cost estimate for obtaining this missing documentation. The A/E shall provide a detailed analysis report inclusive of a professional assessment regarding the overall state of the medical gas systems with each major component addressed. The report shall include an analysis describing specific renovation items to be accomplished to upgrade the medical gas systems in terms of performance, efficiency, operability, reliability, cost of replacement systems, and/or savings in gas supply, maintenance and/or repair costs. The report shall also recommend component replacements based on their service life, obsolescence, safety, or other factors. Specific component manufacturers shall be enumerated if known. The reason for recommended replacement shall be provided. System-wide changes shall also be analyzed. For each system change, problems and solutions shall be stated along with costs and benefits of the recommended change. Pertinent members of the hospital staff shall be consulted such as the clinical medical gas equipment team, facilities management service personnel and others to develop some of these problem/solution pairs. Reference material shall be included in the report, where warranted, to acquaint the reader with all background information needed to make system change decisions. A cost estimate in support of the recommendations provided in the analysis report shall be provided. The Contractor shall brief the VAMC personnel upon completion of the survey. Describe all planned efforts after the survey including specific personnel who will be conducting the system analysis and provide an outline of the analysis report. Deliverables shall include: One hard copy and an electronic version of a draft survey report shall be furnished to the COR seven days prior to the briefing for VAMC review. Five (final) bound hard copies of the survey report shall be delivered to the government within one month after completing the survey and shall incorporate VAMC comments as necessary. One bound colored hard copy and an electronic version of a preliminary plan set of the gas systems record drawings shall be furnished to the COR one month after completion of the survey for VAMC review and comment. Five (final) bound colored hard copies of the gas systems record drawings shall be delivered to the government within two months after the completion of the survey and shall incorporate VAMC comments as necessary. A hard copy and an electronic version of a draft analysis report including all cost estimates shall be furnished to the COR two months after completion of the survey for VAMC review. Five (final) bound hard copies of the analysis report, including all cost estimates, shall be delivered to the government within three months after completing the survey and shall incorporate VAMC comments as necessary. A final electronic submission shall be made per Section 12. One briefing following the survey and meetings per Section 7. Additional deliverables that shall be submitted to the VAMC are specified below. The A/E shall be responsible for the entire work of this project. The A/E shall prepare written limitations on work operations and include these limitations in a letter to the Providence VAMC. Such limitations on work operations shall ensure the continued safe operation of the existing hospital during the project. Prepare an infection control risk assessment in accordance with Infection Control Policies and Procedures of this VAMC for each portion of the existing facility that is impacted by the project. Revise the risk assessment until the VAMC concurs with the results of the risk assessment. Prepare a detailed infection control plan for the A/E team to follow, based on the results of the risk assessment. This plan shall be based on medical center infection control policies and shall be site specific for the areas involved in the project. The survey work must minimize any negative effects to the normal operations of the medical center and this building. Any disruptions to existing operations of this VAMC that are proposed by the Contractor must be approved by the VAMC. Provide any required Interim Life Safety Measures (ILSM) for the project that are necessary during the work in order that the occupied portions of Building 1 will continue to comply with NFPA 101, The Life Safety Code throughout the project. Coordination and Maintainability Coordination is required to ensure that the documentation of all disciplines, and of the documents within each discipline (plans, sections, details, reports, etc.) agree with each other, convey the same information, and do not have conflicts. It is a requirement that A/E dedicates the appropriate time and staff to fully review and ensure coordination of all project documents before submission to avoid request for information (RFI), change orders and delays. Maintainability means the facility is designed and constructed in a manner which promotes efficient and high-quality maintenance procedures with minimal impact to facility function and operations. The A/E shall take this into account when providing recommendations for system upgrades and replacements, concepts for maintainability shall be shared with facility personnel to obtain their input. PROPOSED SCHEDULE: Work shall commence upon receipt of a Notice to Proceed (NTP) from the government and shall be completed within 365 calendar days after receipt of the NTP. Work hours for this project are anticipated to be between 7:00 AM to 4:30 PM, Monday through Friday, holidays excepted, unless other times are arranged in advance and approved in writing by the VA Project Manager. However, when the contractor s work interferes with hospital functions, such as when work produces excessive noise, odors, dust, utility service interruptions, or other interferences with normal hospital operations that cannot be contained within the area of work, the contractor shall schedule said work at other than normal hours and as directed by the Project Manager. In addition, contractor access to occupied patient rooms/areas may not be granted until rooms/areas have become vacant and with the approval of hospital personnel. 4. COST ESTIMATING REQUIREMENTS: The A/E shall develop detailed cost estimates as described in Section 2 above, number 8. As costs for the Providence, Rhode Island, area is substantially different from other areas, particularly Boston, the A/E is required to confirm each section with appropriate databases, manufacturers, sub-contractors, and general contractors to ensure that the various sections are accurate. Also, as the various factors involved in estimating can change rapidly, it is required that the A/E develop the estimate using an Excel spreadsheet that can easily accommodate these changes. All cost estimates for this project shall be prepared in conformance with the VA Manual for Preparation of Cost Estimates for Hospital Projects and VA Program Guide PG-18-15. PLANNING INFORMATION/STANDARDS: General Codes and Standards: The applicable portions of Government criteria in conjunction with industry standards shall govern the preparation of contract drawings, specifications, cost estimate, and Assessments. The work shall also satisfy applicable State of Rhode Island criteria. Emphasis is placed on the following documents that establish minimum requirements. This includes but is not limited to the following: International Building Code (latest edition) National Fire Protection Association 101 Life Safety Code, (latest edition) International Mechanical Code (latest edition) International Plumbing Code (latest edition) National Standard Plumbing Code (latest edition) The National Electrical Code (latest edition) Guidelines for Design and Construction of Health Care Facilities, latest edition published by the Facilities Guidelines Institute (FGI), American Society of Healthcare Engineering (ASHE) Architectural Barriers Act Accessibility Standards (ABAAS) and the VA Barrier Free Design Guide (PG 18-13), a supplement to ABAAS United States National CAD Standard and VHA National CAD Standard Application Guide VHA Program Guide 18-1, Master Construction Specifications VHA Program Guide 18-3, Design and Construction Procedures VHA Program Guide 18-4, Standard Details and CAD Standards VHA Program Guide 18-10, VA Design Manuals VHA Program Guide 18-14, Room Finishes, Door and Hardware Schedules VHA Program Guide 18-15 A/E Submission Requirements Volume C VA Manual for Preparation of Cost Estimates and Related Documents Physical Security and Resiliency Design Manual for VA Facilities Sustainable Design and Energy Reduction Manual (VA Facilities) VA Seismic Design Requirements H-18-8 Providence VAMC Design & Construction Standards b. The A/E shall obtain all data necessary to prepare the documents required. The A/E shall confirm all existing conditions and field verify the as-built drawings provided by the VA. The A/E is wholly responsible for both the accuracy and the level of completeness of the final product and failure to verify information is not acceptable. Information (drawings and other documentation) provided to the A/E by the VA or any other government source shall be used for reference only. 6. MEETINGS: The A/E shall attend meetings at the time and place requested by the Contracting Officer and/or their Representative. Minutes of the meetings shall be taken by the A/E and submitted to the Contracting Officer or their Representative. Meetings shall include the following: a. Project Kickoff Meeting - The A/E shall meet with the Contracting Officer and/or their Representative (from Facilities Management Service), and, if applicable, the Using Service's Representatives, to review project requirements and to clarify the scope of work as necessary. b. Progress Meetings-The A/E shall attend meetings with the Contracting Officer and/or their Representative (from Facilities Management Service), and, if applicable, the Using Service's Representatives as needed to advance progress of the work. 7. SITE VISITS: The A/E may visit the project site prior to starting survey work to obtain the details and specifics of the relevant existing field conditions in order to fully complete the work of this project without omission. Such visits shall include a thorough inspection of normally enclosed or inaccessible areas such as spaces above the ceilings, within walls or chases, in pipe crawl spaces, and in or under basement floors. Arrangements for visits should be made by contacting the COR, at least 48 hours before the visit. 8. QUALITY ASSURANCE/QUALITY CONTROL The A/E is responsible for the quality of the project and all deliverables. The A/E shall develop, execute, and demonstrate that the project plans, reports, ...
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24123R0058- 2×Special NoticeCurrentFeb 8, 2023
C213--650-22-111 Med Gas Survey, Assessment, and Analysis
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
SPECIAL NOTICE FOR QUALIFICATIONS (SF 330) NAICS Code: 541330 Engineering Services (Small Business size standard $25.5M) A. INTRODUCTION: The VA Central Western Massachusetts Healthcare System (CWM HCS) plans to build and install a new elevator tower at Building 25 on the Leeds Campus. This project will correct a FCA deficiency. Provide all professional architectural and engineering (A/E) Part One Services (also known as Design Phase Type A & Type B Services) necessary to develop complete drawings, specifications, and cost estimates associated with building a new elevator tower at Building 25 and Part Two Services (also known as Construction Period Services Type C). The intent of this project includes but is not limited to: Evaluate existing elevator pit slab for buildings 1, 2, 3, 4, 5, 6, 7, 8, 12, 16, 20, and 26 and design an elevator pit sump pump with oil interceptor. Design plumbing of oil water separator to sanitary sewer. See acceptable conceptual design attached. This conceptual design shall be validated. This shall be used to minimize and inform design efforts. Identify and address any issues or conflicts as necessary. If the elevator tower appearance is different than the conceptual design, conduct a Section 106 Historical Submission Report for VA to file with Massachusetts State Historical Preservation Office, by a Professional Historic Preservation Consultant. Existing report will be made available to the highest rated A/E firm. Conduct code compliance reviews (NFPA, ABAAS, VA Design Manuals, etc.) and integrate findings into design for compliance. Where conflicts exist between VA adopted codes and standards and the documents on the TIL, the A/E shall bring this to the attention of the VA. The resolution of the conflict shall be made by the authority having jurisdiction for VA to ensure consistency department wide. The A/E shall provide all services required to prepare documents and reports consistent with the VA s project team goals as prioritized during preliminary project meetings, field surveys and studies. The A/E shall determine existing conditions, severity of deficiencies, if any previous deficiencies have been corrected and to identify any conditions which may have previously been unreported. Cost estimates shall be prepared to reflect the cost of replacing the component in a standalone project (i.e., not as part of another project) and all costs including but not limited to asbestos removal if required, special field conditions and/or temporary equipment needed during the construction. Provide a Qualified Elevator Inspector during Construction Services to certify elevator. Also provide Part Two A/E Services (also known as Construction Period Services Type C) A/E Part Two Services of this design project (also known as Construction Period Services) includes responding to construction contractor Requests For Information (RFIs) during the solicitation (solicitation support) and construction phases of the construction project, attendance at post-award and commissioning kick off construction project conferences, review of construction material submittals and shop drawings, attendance at weekly teleconference construction meetings, approximately 1 site visits per month during active construction (both scheduled and emergent) to ensure compliance with the design drawings and specifications, preparation of site visit reports, coordination with project commissioning requirements/QEI inspection, review of any construction project modifications for cost and technical acceptability, attendance and participation during the pre-final inspection and final acceptance inspection, preparation of the punch list and preparation of record drawings of the completed construction project based on the construction contractor s as-built drawings. The A/E shall prepare a submittal log to be utilized by the VA during construction period services and maintain a RFI log. B. CONTRACT INFORMATION: The VA Medical Center Central Western Massachusetts located in Leeds, MA has a requirement for a Firm Fixed Price contract to provide professional A/E services for the 631-21-011 Building 25 Elevator Design project. The magnitude of construction is between $2,000,000 and $5,000,000. Prospective firms are reminded they must certify that in accordance with VAAR 852.219-75, VA Notice of Limitations on Subcontracting-Certificate of Compliance for Services and Construction (JAN 2023) (DEVIATION), in the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219- 74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. SF330 packages shall address how each firm anticipates meeting this criteria. This requirement is in accordance with the Selection of Architects and Engineers as implemented in Subpart 36.202 of the RFO and Subpart M836.102 of the VA Procurement Manual. All submissions will be evaluated in accordance with the evaluation criteria. A "short list" of the three most highly rated after initial source selection will be chosen for negotiations of a contract award. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Respondents are put on notice that firm(s) selected by the Selection Authority will be required to submit a Fixed Price Proposal on the VA Form 6298 to include labor, overhead, profit, and other costs for this project for negotiation by the Contracting Officer prior to contract award. The negotiated agreement will be incorporated into the resulting contract. C. THIS IS NOT A REQUEST FOR PROPOSAL: This is a request for SF 330s only. Any requests for a solicitation will not receive a response. No material will be issued, and no solicitation package or bidder/plan holder list will be issued. D. PROJECT INFORMATION: Provide all professional architectural and engineering (A/E) services necessary to develop complete drawings, specifications, cost estimates, construction schedules, project phasing, investigations, site visits and construction period services associated with the 631-21-011 Building 25 Elevator Design at the VAMC Central Western Massachusetts HCS, Leeds, MA 01053. E. EVALUATION SELECTION CRITERIA: Each respondent s SF 330 submittal package will be evaluated in accordance with RFO 36.202 procedures. The selection criteria, in descending order of importance will be as follows: 1. Specialized Experience/Technical Competence 2. Professional Qualifications 3. Past Performance F. SELECTION CRITERIA DESCRIPTIONS: The selection criteria descriptions (1 through 3) are provided below in descending order of importance. Specialized Experience/Technical Competence Provide five (5) recent and relevant projects related to the Statement of Work with a similar magnitude (magnitude of construction for the design is between $2,000,000 and $5,000,000) that demonstrates experience with VA Design Requirements or equivalent with significant existing condition renovation. A minimum of three (3) projects should be for comprehensive designs of new elevator builds. Projects should detail the design manual requirements and required equipment for effective operation of an elevator, HVAC, and other necessary mechanical systems. Projects should also detail working with end users and reviewing manufacturer equipment. A minimum of two (2) projects should be for comprehensive designs for exterior historical renovations that took place in the Commonwealth of Massachusetts. These projects should detail the applicable regulation governing historical reviews, explain the process, and demonstrate an understanding of and adherence to the requirements. Recency is defined as performance occurring within five (5) years of the date of this notice. If current projects are provided, these projects must have begun one (1) year prior to the issuance of this notice. Projects that have not been in performance for one (1) year will not be considered. Relevancy is defined as performance of work on projects that are similar in scope to the type of project anticipated under the resultant contract. This factor evaluates the amount of experience and technical competence the firm has in designing similar types of projects. Respondents must provide five (5) recent and relevant projects; any project provided in addition to the five are not required and will not be considered if provided. The following information is required for all projects provided under this criteria any material missing the following requested information will be assessed a deficiency: Contract/Task Order Number Project Title Location Prime Firm with % of self-performed work Subconsultants Start and Completion dates If project is not yet complete, identify the current phase/stage of the project. Fully completed projects will carry more weight than projects still in design Cost of Construction Description of the project in sufficient detail and clearly document how it is relevant to the scope of this project Professional Qualifications Professional qualifications necessary for satisfactory performance of required services. The A/E firm will be evaluated according to their ability to demonstrate the following: education; training; registration; overall and relevant experience; and longevity with the firm of key management and technical personnel. Firms shall provide brief resumes of proposed team members who will specifically serve as the project managers and designers of record, as well as of other relevant team members or subcontractor team members who will perform technical tasks under this contract. Subcontractor team member resumes shall indicate their record of working together with the prime contractor. The minimum required disciplines are Architecture, Structural, Mechanical (HVAC and Plumbing), Electrical, Fire Protection, Interior Design, Elevator Consultant, Cost Estimator. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline, and this must be shown on their resume. Each resume shall include a minimum of three (3) specific completed projects that best illustrate the individual team members experience in their technical field relevant to this project scope; any project provided in addition to the three (3) will not be evaluated as part of this criteria. Past Performance Firms will be evaluated for past performance on recent and relevant contracts with Government agencies (emphasis on VA work) and private industry in terms of cost control, professional performance, general management, cooperativeness, quality of work, compliance with performance schedule, and a record of significant claims against the firm due to improper or incomplete A/E services (references required). The evaluation may consider Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. Past Performance information on contracts not listed by the offeror may also be evaluated. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. While the Government may elect to consider data obtained from other sources, the burden of providing current, accurate, and complete Past Performance information rests with the offeror. The Government reserves the rights to obtain and evaluate Past Performance information from any source it deems appropriate. Respondents with no previous past performance shall state so when addressing the selection criteria. Documentation supplied should detail firms ability to work with government entities and design standards or similar relevant experience with other entities. The following information is required for evaluation of past performance: The A/E firm shall submit past performance evaluations (from CPARS if experience was on a Government contract) for projects provided under Evaluation Criteria 1, Specialized Experience/Technical Competence. In addition to the past performance evaluations the firm shall provide owner points of contact for each project listed to include name, title, telephone number, e-mail, contract number, project name, project description, and start and completion dates. Recency is defined as performance occurring within five (5) years of the date of this notice. If current projects are provided, these projects must have begun one (1) year prior to the issuance of this notice. Projects that have not been in performance for one (1) year will not be considered. Relevancy is defined as performance of work on projects that are similar in scope to the type of project anticipated under the resultant contract. If there is no CPARS data available, Past Performance Questionnaires (PPQs) will be accepted. Please utilize the attached PPQ document. PPQs shall be submitted to the CO not later than the closing date for receipt of the SF 330s. Email PPQs to Brian.Kelly@va.gov. The subject line shall state 36C24126Q0518 Past Performance for (Name of Company) Project 631-21-011 . NOTE: A/E Firms must not review the Past Performance Questionnaire prior to submission. They must be submitted by the client/evaluator directly to the CO. Firms should follow up and encourage references to get the questionnaires to the CO in a timely manner. Do not include copies of the letters or questionnaires in the SF 330 package. Note: We recommend you contact every reference listed and let them know we may contact them for information. Their timely replies would be appreciated. G. QUESTIONS AND COMMENTS: a. Questions and comments regarding this notice must be submitted by email only to the Contracting Officer, Brian Kelly at Brian.Kelly@va.gov. b. Oral questions will not be answered. c. The deadline for questions is November 20, 2026, at 1:00PM EST. H. SF 330 SUBMITTAL PACKAGE PAGE INSTRUCTIONS: a. SF 330 submittal packages, including Past Performance Questionnaires, shall be submitted no later than 4:00PM EST on December 7, 2026. Respondents are responsible for ensuring SF330 submittal packages, any revisions, and modifications are submitted by this time. b. Qualified A/E firms are required to submit ONE (1) electronic copy via email to Brian Kelly at Brian.Kelly@va.gov. If the file is too large to send via email, the offeror may send multiple emails with multiple files (See Self-Service Microsoft Exchange: Email Sending Limits (va.gov) regarding file size). SF 330 forms are available at: https://www.gsa.gov/forms#SF c. Submission of information incorporated by reference is not allowed. d. Prospective firms shall address all selection criteria factors within their submitted SF 330 package. e. Submissions are limited to 65 pages. i. Absolutely no photographs shall be submitted. ii. Title pages and tables of contents, if applicable, are excluded from the page count limitation. iii. Pages submitted in excess of the limitations specified in this Notice will not be evaluated by NCO 1. f. Telephone or fax inquiries will not be accepted. I. SF 330 PACKAGE CONTENTS: a. The SF 330 submittal packages shall consist of a completed SF 330, specific information addressing each of the seven selection criteria described in this Notice. b. Respondents are required to meet all requirements in addition to those identified as selection criteria. c. SF 330 submittal packages not consistent with the requirements and selection criteria of this notice may be determined unacceptable and removed from consideration. d. Any SF 330 submittal package, modification, or revision, that is received after the exact time specified for receipt is late and will not be considered unless the contracting officer determines that accepting the late submittal would not unduly delay the acquisition; and there is acceptable evidence to establish that it was received at NCO 1 installation designated for receipt of submittal packages and was under NCO 1 s control prior to the time set for receipt of submittal packages; or it was the only submittal package received. J. SF 330 PACKAGE PREPARATION: a. Qualified A/E firms are required to submit ONE (1) electronic copy via email to Brian Kelly at Brian.kelly@va.gov. SF 330 forms are available online at: https://www.gsa.gov/forms#SF. b. Electronic copy shall be in searchable PDF format of the SF 330. c. A cover sheet should be included, clearly marked with the Respondent's name, complete address with 9-digit zip code, phone number, e-mail address, UEI number, date of response, title and notice identification. d. A table of contents shall be provided for ready reference to sections and figures. e. SF 330 submittal packages shall be consistent with the following structure and formatted accordingly: SF 330 PART I CONTRACT SPECIFIC QUALIFICATIONS 1. Sections A through D 2. Section E 3. Section F 4. Section G 5. Section H 6. Section I 7. Other additional information and attachments SF 330 PART II GENERAL QUALIFICATIONS (Note: Respondents shall clearly label additional information and attachments). K. FAR and VAAR: The FAR, VAAR, and VAAM citations referenced in this Special Notice can be accessed via the following links: FAR https://www.acquisition.gov/ VAAR https://www.va.gov/oal/library/vaar/index.asp VAAM https://www.va.gov/oal/library/vaam/ | - | Special Notice | 12/07/2026 |
| - | Awarded | Open | |
Introduction Network Contracting Office 1 (NCO 1), supporting VA New England Healthcare System (VISN 1), is seeking potential sources for an upcoming requirement for Architect and Engineering Services as described in the attached statement of work. THIS NOTICE IS NOT A REQUEST FOR QUALIFICATION STATEMENTS (SF330). This notice is a market research tool and has not been set-aside for any small business category, but the notice is issued to determine appropriate set-aside categories. Responses to this notice, in conjunction with other Government market research resources, will be used by the contracting officer to determine the applicable socio-economic set-aside for the procurement. Failure to respond to this notice will not impact consideration of architect and engineer firms (or joint ventures) which otherwise meet set-aside requirements and submit responses to the follow-up public announcement. Once the appropriate set-aside is determined, a separate public announcement requesting qualification statements (SF330s) will be publicized on Contract Opportunities in accordance with 40 U.S. Code § 1101 and FAR 36.102. General Project Description and NAICS Synopsis of required services (See attachment for full statement of work): provide Architect/Engineer (AE) services to evaluate existing conditions, propose corrective measures, and design a construction project at the VA Maine Health Care System (Togus) in accordance with this scope of work. Scope will include Type A services only with design complete to 35%. AE Part I Investigative Services/Schematic Design/Other Related Services shall include site visits, field investigation, studies and user interviews to prepare drawings, and cost estimates for all facets of work and disciplines/trades to repair Chiller 3 to a condition where it will operate as designed. Design should also include fixes for the reported cooling and oil leaks. This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has a SBA size standard of $22.5 million in average revenue. Information Sought The Government requests a letter of interest (or similar document) with responses to the following: 1. State your firm name (as it appears in SAM.gov), Unique Entity Identifier (UEI) number, and socio-economic status of the firm (i.e. verified SDVOSB, WOSB, SB, large business). 2. Provide a brief narrative on the firm s experience, providing services similar to those described in the attached statement of work. 3. What would be the expected make-up of the firm s team in terms of socio-economic categories and estimated percentage of work to be completed by your firm and each subcontractor? If the procurement is set-aside for any category of small business, generally fifty percent of more of the work would need to be performed by the contractor or a similarly situated subcontractor in terms of percentage of cost. For instance, if set-aside for service-disabled veteran-owned small business (SDVOSB), 50% or more of the contract would need to be performed by verified SDVOSBs no other small business categories would count towards the percentage. If set-aside for small business, 50% of the contract would be required to be performed by small businesses which would include performance by a verified SDVOSB because they are also a small business. If the procurement is not set-aside and reaches certain dollar thresholds, the Government would negotiate an acceptable subcontracting plan to utilize small business concerns. 4. A brief statement of overall interest in the project and capability of performing the work in conjunction with ongoing projects. 5. Any additional capabilities statements or other documentation that you feel will assist the Government in performing market research and determining the appropriate set-aside. Submission Instructions Interested parties are requested to submit the requested information not later than November 20, 2026, to Diane C. Davis via email to diane.davis2@va.gov. Please include 36C24127R0009 Sources Sought Response in the title of the email. the response burden to this notice is expected to be light; lengthy responses are not expected but no maximum page count is assigned. Please keep responses below 7MB or send multiple emails appending to the email subject 1 of n as appropriate. Please contact Diane Davis at the email address above with any questions. Attachments | - | Market Research | 11/20/2026 |
DESCRIPTION: This is a Pre-Solicitation Notice for project number 596A4-27-101 that requires Architect/Engineering (A/E) Design Services to Upgrade Fire Alarm System at the Lexington VA Healthcare System, Troy Bowling Campus. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSALS. ONLY THE A/E FIRMS RESPONDING TO THIS ANNOUNCEMENT BY SUBMITTING AN SF330 PACKAGE ON TIME WILL BE CONSIDERED FOR INITIAL EVALUATION. FOLLOWING INITIAL EVALUATION OF THE A/E FIRMS AND THEIR SF330S, A SOLICITATION FOR A PRICE PROPOSAL WILL BE SENT TO THE HIGHEST TECHNICALLY RATED A/E FIRM TO PROVIDE THE TYPE OF SERVICE(S) REQUIRED. The A/E Services contract that is anticipated to be awarded will be procured in accordance with the Brooks Act (Public Law 92- 582), Federal Acquisition Regulation Part 36.6 and VA Acquisition Regulation 836.6. In accordance with FAR 36.209 Construction Contracts With Architect-Engineer Firms , no contract for the construction of a project shall be awarded to the firm that designed the project or its subsidiaries or affiliates, except with the approval of the head of the agency or authorized representative. A/E DESIGN SERVICES SCOPE SYNOPSIS: The A/E will be required to perform comprehensive field investigations to base their design documents off of, this includes, above ceiling surveys that the VA will assist with access to all required spaces. Project will replace existing fire alarm system at the Troy Bowling Campus to include Building 1, Building 1A and Building 4. Replacement includes hospital space, parking garage as well as crawl space as required per code. Size of existing facility is 537,542 square feet. Existing fire alarm system is required to remain in service until new system is active and ready to be utilized. Phasing of cutover from existing to new system to be determined by A/E. Project will correct FCA Deficiencies 338139, 45058, 49003, 49909, 49035, 49963 and 49935. New fire alarm system will be required to interact with multiple systems throughout the hospital to include, but not limited to: Door magnets, elevators, HVAC systems, kitchen hood systems, sprinkler system, specialty fire suppression systems, door locking systems, smoke dampers, duct detectors and other systems. The estimated magnitude of construction for this A/E requirement is between $10,000,000 and $20,000,000. END OF DESIGN SCOPE SYNOPSIS Digital copies of the as-builts are limited. The consultant will be expected to fully investigate and confirm the validity of hard copy as-builts and other drawings. This will include independent investigation of the VAMC s flat files by the consultant to determine and procure the information required for the complete design. All offerors are advised that in accordance with VAAR 836.606-73 the total cost of the architect or engineer services contracted for must not exceed 6 percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR Clause 52.236-2 (c) - Design Within Funding Limitation, will be applicable to this procurement action. Design limitation costs will be provided to the most highly rated AE firm selected to complete the design. Interested firms should submit their current SF-330 to matthew.whisman@va.gov. The SF-330s are due by December 3, 2026, at 2:00 PM (EST). Security Issues, Late Bids, Unreadable Offers Late submission of offers are outlined at FAR Parts 52.212-1(f), 52.214-7, and 52.215-1(c) (3). Particular attention is warranted to the portion of the provision that relates to the timing of submission. Please see FAR 15.207(c) for a description of the steps the Government shall take with regard to unreadable offers. To avoid rejection of an offer, vendors must make every effort to ensure their electronic submission is virus-free. Submissions or portions thereof submitted and which the automatic system detects the presence of a virus or which are otherwise unreadable will be treated as unreadable pursuant to FAR Parts 14.406 and FAR 15.207(c ). The virus scanning software used by our e-mail systems cannot always distinguish a macro from a virus. Therefore, sending a macro embedded in an e-mail message or an e-mail attachment may cause the e-mail offer to be quarantined. You may send both the spreadsheet and the spreadsheet saved in PDF format to ensure that your proposal is readable. Password protecting your offer is not permitted. The Contracting Officer will file the offer electronically which will allow access only by designated individuals. Important Notice: Apparent successful offerors must be registered in the U.S. Small Business Administration (SBA) site at the time of submission of proposal. Failure to be both VERIFIED by the SBA and VISIBLE at the time of proposal submission, time of interview, and at time of award will result in the offeror s proposal being deemed non-responsive. All offerors are urged to contact the SBA DSBS (https://dsbs.sba.gov/search/dsp_dsbs.cfm) and submit the required documents to obtain verification of their SDVOSB status if they have not already done so. Response Time: The successful A-E shall abide by a four (4) hour response time for Lexington VA Healthcare System, during the design phase and the construction period services (CPS) phase, as appropriate. The VA has no preference on the method utilized by contractors on achieving the four (4) hour response time. The response time will be determined from the moment the request to the A-E to be on site is submitted. The individual or individuals responding can be either the prime contractor or a subcontractor that s part of the design team. The selection process will follow the guidance referenced within 36.602-3 and FAR 36.602-4. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Firms will be selected based on demonstrated competence and qualifications for the required work. Contract Award Procedure: Before a small business is proposed as a potential contractor, they must be certified by SBA DSBS and registered in the System For Award Management (SAM) database. Register via the SAM internet site at https://sam.gov/content/home Failure of a proposed SDVOSB to be certified by the SBA DSBS at the time the SF 330 is submitted shall result in elimination from consideration as a proposed contractor. The proposed services will be obtained by a Negotiated Firm-Fixed Price Contract. The review/design of architectural, structural, mechanical, electrical, civil, or other engineering features of the work shall be accomplished by architects or engineers registered in a State or possession of the United States, or in Puerto Rico or in the District of Columbia. The project drawings/design shall be in compliance with applicable standards and codes described in VA Program Guides and design materials. Master Construction Specifications Index, VA Construction Standards Index, VA Standards Index, and Criteria are available in the Technical Information Library (TIL) on VA Website address: http://www.cfm.va.gov/til/. The awarded A/E firm will prepare drawings and specifications in sufficient detail such that qualified outside General Contracting companies can prepare accurate and timely proposals for the desired work. The awarded A/E firm is responsible for ensuring that the specifications and drawings supplied fully represent all of the work described in the Request for Proposal (RFP). The Medical Center must remain operational throughout the construction period and a detailed sequence of work will be provided by the A/E to minimize impact of the construction. The NAICS code for this project is 541330 with a small business size of $25.5 million. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, type in SF-330 in the Find a Form block and click on search. SELECTION CRITERIA: Selection criteria for this acquisition are listed below; Professional qualifications necessary for satisfactory performance of required services; Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; Capacity to accomplish the work in the required time; Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness; Record of significant claims against the firm because of improper or incomplete architectural and engineering services; and Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. THIS IS NOT A REQUEST FOR PROPOSAL. This is a request for SF 330's Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. No material will be issued and no solicitation package or bidder/plan holder list will be issued. A solicitation will only be issued to the most highly qualified vendor. Electronic Submission Requirements: Unless paper offers are specifically authorized in an individual solicitation, all responses to solicitations must be submitted electronically as described below. Responses submitted in a paper form are unacceptable and will be returned. Failure to comply with this requirement may jeopardize the possibility of receiving an award for the contract due to noncompliance with the terms of the solicitation. You must submit your electronic offer, and any supplemental information (such as spreadsheets, backup data, technical information), using any of the electronic formats and media described below. Additionally, contractors are notified of the award via an electronic Notice of Award e-mail. The award document will be attached to the Notice of Award e-mail. Acceptable Electronic Formats (Software) for Submission of Offers Files readable using the current Microsoft* Office version Products: Word, Excel, and PowerPoint. Please see security note below for caution regarding use of macros. When submitting construction drawings contractors are required to submit one set in AutoCAD and one set in Adobe PDF. (purpose: contracting can open the PDF version and engineering can open AutoCAD files); Files in Adobe* PDF (Portable Document Format) Files: When scanning documents scanner resolution should be set to 200 dots per inch, or greater; Other electronic format.  If you wish to submit an offer using another format other than described in these instructions, e-mail the Contracting Officer who issued the solicitation.  Please submit your request at least ten (10) calendar days before the scheduled closing date of the solicitation.  Request a decision as to the format acceptability and make sure you receive approval of the alternate format before using it to send your offer; and Submitted SF330 s are not to exceed a total of fifty (50) pages INCLUDING cover page and any other submitted documents. Please note that we can no longer accept .zip files due to increasing security concerns. E-mail Submission Procedures: For simplicity in this guidance, all submissions in response to a solicitation will be referred to as offers. Subject Line: Include the solicitation number, name of company, and closing date of solicitation; Size: Maximum size of the e-mail message shall not exceed five (5) megabytes. Only one email is permitted unless otherwise stated in this paragraph or in writing by a Contracting Officer. Submission is to be no more than a total of fifty (50) pages; and The offer will be date and time stamped by the Microsoft Email system and will be the official record of receipt for the submission. Point of Contact : Matthew Whisman E-mail questions to: matthew.whisman@va.gov VA NOTICE OF TOTAL SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS SET-ASIDE (DEC 2009) (a) Definition. For the Department of Veterans Affairs, Service-disabled veteran-owned small business concern : (1) Means a small business concern: (i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans (or eligible surviving spouses); (ii) The management and daily business operations of which are controlled by one or more service-disabled veterans (or eligible surviving spouses) or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran; (iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document; and (iv) The business has been verified for ownership and control and is so listed in the Vendor Information Pages database, (https://dsbs.sba.gov/search/dsp_dsbs.cfm). (2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16). (b) General. (1) Offers are solicited only from service-disabled veteran-owned small business concerns. Offers received from concerns that are not service-disabled veteran-owned small business concerns shall not be considered. (2) Any award resulting from this solicitation shall be made to a service-disabled veteran-owned small business concern. (c) Agreement. A service-disabled veteran owned small business concern agrees that in the performance of the contract, in the case of a contract for: (1) Services (except construction), at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other eligible service-disabled veteran-owned small business concerns; (2) Supplies (other than acquisition from a non-manufacturer of the supplies), at least 50 percent of the cost of manufacturing, excluding the cost of materials, will be performed by the concern or other eligible service-disabled veteran-owned small business concerns; (3) General construction, at least 15 percent of the cost of the contract performance incurred for personnel will be spent on the concern s employees or the employees of other eligible service-disabled veteran-owned small business concerns; or (4) Construction by special trade contractors, at least 25 percent of the cost of the contract performance incurred for personnel will be spent on the concern s employees or the employees of other eligible service-disabled veteran-owned small business concerns. (d) A joint venture may be considered a service-disabled veteran owned small business concern if (1) At least one member of the joint venture is a service-disabled veteran-owned small business concern, and makes the following representations: That it is a service-disabled veteran-owned small business concern, and that it is a small business concern under the North American Industry Classification Systems (NAICS) code assigned to the procurement; (2) Each other concern is small under the size standard corresponding to the NAICS code assigned to the procurement; and (3) The joint venture meets the requirements of paragraph 7 of the explanation of Affiliates in 19.101 of the Federal Acquisition Regulation. (4) The joint venture meets the requirements of 13 CFR 125.15(b). (e) Any service-disabled veteran-owned small business concern (non-manufacturer) must meet the requirements in 19.102(f) of the Federal Acquisition Regulation to receive a benefit under this program. END OF PRE-SOLICITATION NOTICE | - | Pre-Solicitation | 12/03/2026 |
Modification 2 to Presolicitation Notice 36C25527R0013 This modification provides answers to RFIs received and revised the evaluation criteria to be used for this project. RFIs Received for Project # 657A5-24-108, Replace Medium Voltage Feeder 3 and Transformers 1. Factor 4 Past Performance / Section F Project Eligibility  The solicitation states that projects submitted for past performance consideration must have completed both design and construction, and that projects not constructed will not be considered. Would the VA consider accepting relevant electrical infrastructure studies or assessments in Section F, particularly those involving medium-voltage distribution systems and feeder evaluations, that demonstrate directly applicable technical expertise but did not result in construction? We prefer to keep it as projects that were designed AND constructed. Since this is a construction project and not a study, we want projects that have been finished to be used for past performance criteria.  2. Factor 2 Specialized Experience and Technical Competence / Laboratory Requirements  Factor 2 references the firm's technical capabilities in design quality management procedures, CADD/BIM, equipment resources, and laboratory requirements. Given that the project scope primarily involves medium-voltage electrical feeder and transformer replacements, could the VA clarify the applicability of laboratory requirements to this project? We respectfully request that this criterion be removed from the evaluation requirements, as it does not appear directly relevant to the stated scope of work. Laboratory requirements were deleted. Please see revised evaluation criteria below.  3. Request for Submission Deadline Extension Given the technical scope of the project and the level of detail required to address the evaluation criteria, we respectfully request a one-week extension of the SF330 submission deadline, from November 10, 2026, to November 17, 2026. This additional time would allow interested firms to prepare comprehensive qualifications packages that fully address the solicitation requirements. SF330 submission due date extended from 11/10/2026 to 11/172026. End of RFIs. | - | Pre-Solicitation | 11/17/2026 |
Additional Details
Solicitation Number
36C24123R0058
Archive Date
May 18, 2023
Office Address
TOGUS, ME, 04330