GovChime
Notice ID: 9902706ea2504cdb8550a43491cc9ec6Special Notice

6515--Intent to Sole Source: VISN 1 Olympus GI SCOPE Lease 36 month

Archived on April 18, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM UTC−04:00
Posted
April 2, 2024
Notice type
Special Notice
NAICS
339113: Surgical Appliance and Supplies Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
241-NETWORK CONTRACT OFFICE 01 (36C241)
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C24124Q0344
Notice ID
9902706ea2504cdb8550a43491cc9ec6

Description

NOTICE OF THE INTENT TO SOLE SOURCE TO OLYMPUS AMERICA INC, 3500 CORPORATE PKWY, CENTER VALLEY, PA 18034-8229 Response Due Date: 4/08/24, by 4:00PM (EST) NOTICE OF THE INTENT TO SOLE SOURCE SYNOPSIS Network Contract Office 1, Procurement Office East on behalf of The Department of Veterans Affairs, VISN 1, Leeds VA Medical Center located at 421 North Main Street, Leeds, MA 01053 intends to award a firm-fixed contract to OLYMPUS AMERICA INC. to provide a 36-Month Lease of Olympus GI Scopes for VISN 1 VHA. The proposed procurement is for products and services for which the Government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. 41 U.S.C. 3304(a)(1). The North American Industry Classification System code (NAICS) for this requirement is 339113. All responsible sources that feel they should be considered qualified to provide the above-mentioned products may submit a response to this notice (by the response due date shown above) to kurt.fritz@va.gov. The information provided shall include detailed (and relevant) documentation to allow the government to perform adequate market research and make a proper determination. A determination by the government not to compete this proposed requirement based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. THIS IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. THERE IS NO SOLICITATION AVAILABLE AT THIS TIME. REQUESTS FOR A SOLICITATION WILL NOT RECEIVE A RESPONSE.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24124Q0344
  1. 3×
    Special NoticeCurrentApr 2, 2024

    6515--Intent to Sole Source: VISN 1 Olympus GI SCOPE Lease 36 month

    Notice 9902706ea2504cdb8550a43491cc9ec6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-Market Research09/07/2026
UltraScan Versa Premier Tables
-Combined Synopsis09/27/2026
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Patient safety lifts The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts. All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Salient characteristics (QTY 21) Patient Safety Lifts All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021 xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better 4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1)
-Market Research09/10/2026
36C24125R0116 Anesthesia procurement
-Pre-Solicitation11/02/2026
The Department of Veterans Affairs (VA) intends to solicit for anesthesia units (to include warranty, maintenance and training) for inclusion into the National Equipment Catalog (NEC). This is a Request for Proposals (RFP) for anesthesia units at the national level. The Department of Veterans Affairs intends to establish Indefinite Delivery/Indefinite Quantity (ID/IQ) contracts. This solicitation will result in multiple awards. The ID/IQs will cover the entire nation. The contract s performance period is for ten years, inclusive of a five-year base period and one, five-year option period. Telephone requests for information or questions will NOT be accepted. PLEASE SUBMIT QUESTIONS REGARDING THIS RFP NO LATER THAN 4PM EST ON FRIDAY, AUGUST 21, 2026. QUESTIONS OR COMMENTS SHOULD BE SUBMITTED TO THE CONTRACT SPECIALIST, MELANIE STOCKMAN AT melanie.stockman@va.gov .
-Combined Synopsis10/05/2026

Additional Details

Solicitation Number

36C24124Q0344

Archive Date

Apr 18, 2024

Office Address

TOGUS, ME, 04330