GovChime
Notice ID: 72c496f514b343bba8517634a840ba35Combined Synopsis/Solicitation

J041--Airflow Testing (VA-24-00022718)

Archived on June 1, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM UTC−04:00
Posted
May 7, 2024
Notice type
Combined Synopsis/Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of Veterans Affairs

Notice details

Office
241-NETWORK CONTRACT OFFICE 01 (36C241)
Place of performance
VAMC West Haven 950 Campbell Ave, West Haven, CT, 06516
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C24124Q0423
Notice ID
72c496f514b343bba8517634a840ba35

Description

Combined Synopsis-Solicitation for Commercial Products and Commercial Services Revision 01 Effective: 05/30/2023 Description This is a combined synopsis/solicitation for commercial products and services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as RFQ 36C24124Q0423. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-03. The associated North American Industrial Classification System (NAICS) code for this procurement is NAICS 238220 (Plumbing, Heating, and Air-Conditioning Contractors) size standard $19 million. This is an SDVOSB set-aside. VA Connecticut Healthcare System West Haven and Newington Campuses requires complete Airflow Testing of the rooms listed by building and room number. VACHS is currently seeking services for all labor, materials, transportation, parts, and expertise necessary to provide quarterly and annual testing and air balancing required. Please reach out to Melissa Metevelis melissa.metevelis@va.gov 2003-932-5711 x4199 or Chris Metner christopher.metner@va.gov for all technical questions with the below SOW. All interested companies shall provide quotations for the following: STATEMENT OF WORK BACKGROUND VA Connecticut Healthcare System West Haven and Newington Campuses requires complete Airflow Testing of the rooms listed by building and room number. VACHS is currently seeking services for all labor, materials, transportation, parts, and expertise necessary to provide quarterly and annual testing and air balancing required. Please price for 4 quarterly tests, 1 annual test, and how much it would be to air balance if a room is found unsatisfactory. The rooms are listed below in the description of service. Also price out for Base year and 4 option years. JUSTIFICATION Veterans Health Administration (VHA) seeks to continue to improve the operational capabilities by establishing services that result in fewer operational problems, improved communications, increased efficiency within the facility and to improve the quality of services to veterans. LOCATION OF SERVICES VA Medical Center West Haven 950 Campbell Avenue West Haven, CT 06516 VA Medical Center Newington 555 Willard Avenue Newington, CT 06111 PERIOD OF PERFORMANCE Base contract period shall be 06/01/2024 05/31/2025. The contract will also contain the provision for (4) annual option years: Option Year 1: 06/01/2025 05/31/2026 Option Year 2: 06/01/2026 05/31/2027 Option Year 3: 06/01/2027 05/31/2028 Option Year 4: 06/01/2028 05/31/2029 QUALIFICATIONS To be considered eligible for consideration, potential bidders shall have a field service representative located within 200 miles of the West Haven and Newington Campuses of the VA Connecticut Healthcare System and have been trained by the Original Equipment Manufacturer (OEM) on the specific model of equipment that he/she is being asked to provide services for. Bidders shall provide upon request, documentation of factory certified service/maintenance training on the specific equipment under the terms of this contract. The Contracting Officer and/or Contracting Officer s Representative (COR) specifically reserve the right to reject any of the Contractor s personnel and refuse them permission to work on the equipment outlined herein, based upon credentials provided. The service provider shall be either a certified member of AABC, NEBB, or TABB to perform TAB service for HVAC. The service provider shall be a certified firm and have certified professionals on staff. The certification shall be maintained for the entire duration of duties specified herein. If, for any reason the agency loses subject certification during this period, the CO and COR shall be immediately notified, and a corrective action plan submitted for approval. Any agency that has been the subject of disciplinary action by either the AABC, TABB, or NEBB within the five (5) years preceding Contract Award shall not be eligible to perform any work related to this contract. Service Provider: The service provider shall be either a member of AABC or TABB or an experienced technician of the Agency certified by NEBB. The certification shall be maintained for the entire duration of duties specified herein. If, for any reason, the Specialist loses subject certification during this period, immediately notify the CO and COR and submit another Specialist for approval. Any individual that has been the subject of disciplinary action by either the AABC or the NEBB within the five (5) years preceding Contract Award shall not be eligible to perform any duties related to the HVAC systems, including TAB. The service provider will be coordinating, scheduling, and reporting all work related activities and will provide necessary information as required by the COR. The responsibilities include: Complete air balancing to design specifications and manufacturers equipment design standards. Shall directly supervise all testing work. Shall sign the testing reports that bear the seal of the TAB standard. The reports shall be accompanied by report forms and schematic drawings required by the TAB standard, AABC, TABB, or NEBB. Shall make special notations of variances from design quantities which exceeds plus or minus ten percent of design specifications. Shall ensure any holes or openings made in duct work to facilitate testing are plugged, sealed, and labeled for intended purpose upon completion of work. Shall supply all labor, material, equipment, tools, supervision and all incidentals to complete Dispersed Oil Particulate (DOP) testing on all HEPA filters in all Air Handlers/Supply/Return/Exhaust noted herein which contain HEPA filters in the supply/return/exhaust and shall be tested in accordance with current ASHRAE standards in addition to Federal Standard 209E, ISO 14644, IEST RP-006.3 and AFM procedural standard AHFB0607. All leaks shall be sealed by acceptable trade practice and retested to ensure that each system meets the acceptable particle count standards as per the herein referenced standards and codes. Testing shall be completed by the total probe scan method, installation pressure drop testing, monitoring for temperature and humidity, room pressurization testing and air exchanges per hour. Follow all testing work through its satisfactory completion; document all findings and results and submit a detailed work order ticket per unit and/or test at end of the day s work to the COR and VA Contracting Officer. Include the same information in the follow up formal report with clear call outs for findings and recommendations. All technicians performing actual testing work shall be experienced and must have satisfactory performance on a minimum of three projects comparable in size and complexity to this scope. Qualifications must be certified by the Service Provider in writing. The lead technician and all assigned technicians shall be certified by AABC, TABB, or NEBB. Test Equipment Criteria: The instrumentation shall meet the accuracy/calibration requirements established by AABC National Standards, TABB/SMACNA International Standards, or by NEBB Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems and instrument manufacturer. Provide calibration history of the instruments to be used for test and balance purposes as part of every formal report for every unit and/or test. . Submit names and qualifications of TAB specialists a minimum of ten (10) business days prior to starting quarterly and annual testing in writing to the COR and the VA Contracting Officer. Subcontracting of ay ensuing award of this solicitation shall not be allowed without written permission of the Contracting Officer. Service response on calls from unauthorized personnel could result in non-payment. SCOPE OF WORK The contractor shall furnish all labor, materials, equipment, tools, supervision, and all incidentals to complete the work for the services described in this document including testing, inspections and unscheduled service calls. Scheduled maintenance shall be completed Monday through Friday outside of regular business hours after 5:00 p.m. and before 6:00 a.m. a minimum notice of three (3) weeks. No work shall be performed on Government Holidays unless an emergency status has been indicated by the VA Contracting Officer. Description of Services: Quarterly and Annual Airflow Testing to maintain compliance with: VHA Directive 1116 Sterile Processing Services (SPS) 2023 ANSI/ASHRAE/ASHE Standard 170-2017 Ventilation of Healthcare Facilities VHA HEFP HVAC Design Manual Rev November 1, 2022. Semi- Annual HEPA filter testing. Schedule and coordinate areas to be tested with the COR and with a three (3) week notice. Provide complete airflow testing and hard copy report to include air changes per hour for each room and pressure relationship to surrounding spaces for the following spaces (see attachment 1 for floor plans showing the locations of each room). West Haven Quarterly Testing Hours of Work Service Secondary Bldg Room Typ Hours Days of Week SPS Soft Supply Storage 1 SG-173 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Prep 1 SG-192 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Decon 1 SG-193 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Steris Decon Mobile Mobile 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Steris Prep Mobile Mobile 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 2106 8:00 a.m. 4:30 p.m. Saturday - Sunday OR Bulk Storage 1 2216 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3219 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3234 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3258A 8:00 a.m. 4:30 p.m. Saturday - Sunday West Haven Bi-Annual Testing Hours of Work Service Secondary Bldg Room Typ Hours Days of Week Oncology Infusion 2 5203 8:00 a.m. 4:30 p.m. Saturday - Sunday 8:00 a.m. 4:30 p.m. Saturday - Sunday West Haven Annual Testing Hours of Work Service Secondary Bldg Room Typ Hours Days of Week SPS Soft Supply Storage 1 SG-173 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Prep 1 SG-192 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Decon 1 SG-193 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Steris Decon Mobile Mobile 8:00 a.m. 4:30 p.m. Saturday - Sunday SPS Steris Prep Mobile Mobile 8:00 a.m. 4:30 p.m. Saturday - Sunday Inpatient Pharmacy Pharmacy 1 G220 4:00 p.m. 11:00 p.m. Monday Friday Inpatient Pharmacy Biohazard 1 G220C 4:00 p.m. 11:00 p.m. Monday Friday Inpatient Pharmacy Chemo Room 1 G220F 4:00 p.m. 11:00 p.m. Monday Friday Inpatient Pharmacy Buffer Room 1 G220G 4:00 p.m. 11:00 p.m. Monday Friday Inpatient Pharmacy Ante Room 1 G220E 4:00 p.m. 11:00 p.m. Monday Friday Inpatient Pharmacy Clean Prep 1 G220H 4:00 p.m. 11:00 p.m. Monday Friday CATH Lab Scrub Room 1 1109 8:00 a.m. 4:30 p.m. Saturday - Sunday CATH Lab Procedure 1 1111 8:00 a.m. 4:30 p.m. Saturday - Sunday CATH Lab Control Room 1 1117 8:00 a.m. 4:30 p.m. Saturday - Sunday CATH Lab Procedure 1 1115 8:00 a.m. 4:30 p.m. Saturday - Sunday CATH Lab Control Room 1 1110 8:00 a.m. 4:30 p.m. Saturday - Sunday CATH Lab Cath Storage 1 1107 8:00 a.m. 4:30 p.m. Saturday - Sunday IR Angiography 1 1128 8:00 a.m. 4:30 p.m. Saturday - Sunday IR PAX Room 1 1129 4:00 p.m. 11:00 p.m. Monday Friday IR RAD Storage 1 1130A 8:00 a.m. 4:30 p.m. Saturday - Sunday Blood Lab Clinical Lab 1 1229 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Blood Bank 1 1193 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Blood Bank 1 1195 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Blood Bank 1 1196 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Molecular Diagnostics 1 1197 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Pharma Cogenetics 1 1202 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Media Prep 1 1203 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Media Prep 1 1205 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Microbiology 1 1208 4:00 p.m. 11:00 p.m. Monday Friday Blood Lab Molecular Diagnostics 1 1213 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Microscopy 1 1185 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Surgical Anatomic Pathology 1 1180 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Histology 1 1175 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Cytology 1 1174 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Supply 1 1173 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Anatomic Pathology 1 1169 4:00 p.m. 11:00 p.m. Monday Friday Laboratory Lab 1 1165 4:00 p.m. 11:00 p.m. Monday Friday SICU Isolation Room 1 3119 4:00 p.m. 11:00 p.m. Monday Friday Endoscopy Scope Storage 1 3194 4:00 p.m. 11:00 p.m. Monday Friday Endoscopy Decon 1 3189A 4:00 p.m. 11:00 p.m. Monday Friday Endoscopy OER/HLD 1 3189B 4:00 p.m. 11:00 p.m. Monday Friday OR RMD Storage 1 2106 8:00 a.m. 4:30 p.m. Saturday - Sunday OR Bulk Storage 1 2216 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3219 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3234 8:00 a.m. 4:30 p.m. Saturday - Sunday OR RMD Storage 1 3258A 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 1 OR Suite 1 3216 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 2 OR Suite 1 3258 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 3 OR Suite 1 3236 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 4 OR Suite 1 3238 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 5 OR Suite 1 3227 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 6 OR Suite 1 3244 8:00 a.m. 4:30 p.m. Saturday - Sunday OR 7 OR Suite 1 3246 8:00 a.m. 4:30 p.m. Saturday - Sunday Pre Op OR Suite 1 3212 8:00 a.m. 4:30 p.m. Saturday - Sunday PACU OR Suite 1 3251 8:00 a.m. 4:30 p.m. Saturday - Sunday FLEX Isolation 1 5167 4:00 p.m. 11:00 p.m. Monday Friday FLEX Isolation 1 5168 4:00 p.m. 11:00 p.m. Monday Friday FLEX Isolation 1 5169 4:00 p.m. 11:00 p.m. Monday Friday MICU Bronch Room 1 5216 4:00 p.m. 11:00 p.m. Monday Friday 6W Isolation 1 5167 4:00 p.m. 11:00 p.m. Monday - Friday 6W Isolation 1 6127 4:00 p.m. 11:00 p.m. Monday Friday 6W Isolation 1 6128 4:00 p.m. 11:00 p.m. Monday Friday Psych ED Exam Room 2 1209 4:00 p.m. 11:00 p.m. Monday Friday Psych ED Exam Room 2 1210 4:00 p.m. 11:00 p.m. Monday Friday Psych ED Exam Room 2 1211 4:00 p.m. 11:00 p.m. Monday Friday Dialysis Treatment Room 2 G123F 4:00 p.m. 11:00 p.m. Monday Friday Dialysis Treatment Room 2 G123D/E 4:00 p.m. 11:00 p.m. Monday Friday Dialysis Treatment Room 2 G123D/E 4:00 p.m. 11:00 p.m. Monday Friday Psych ED Isolation 2 4:00 p.m. 11:00 p.m. Monday Friday Dialysis Isolation 2 4:00 p.m. 11:00 p.m. Monday Friday Dialysis Isolation 2 4:00 p.m. 11:00 p.m. Monday Friday Outpatient Pharmacy Active Storage 2 2104 4:00 p.m. 11:00 p.m. Monday Friday Outpatient Pharmacy Storage 2 2104D 4:00 p.m. 11:00 p.m. Monday Friday Outpatient Pharmacy Vault 2 2104DA 4:00 p.m. 11:00 p.m. Monday Friday Dental Storage 2 2120 4:00 p.m. 11:00 p.m. Monday Friday Dental Operatory 2 2119 4:00 p.m. 11:00 p.m. Monday Friday Dental Operatory 2 2118 4:00 p.m. 11:00 p.m. Monday Friday Dental Storage 2 2117E 4:00 p.m. 11:00 p.m. Monday Friday Dental Exam 2 2117D 4:00 p.m. 11:00 p.m. Monday Friday Dental Exam 2 2117C 4:00 p.m. 11:00 p.m. Monday Friday Dental Exam 2 2117B 4:00 p.m. 11:00 p.m. Monday Friday Dental Laboratory 2 2117A 4:00 p.m. 11:00 p.m. Monday Friday Dental Storage 2 2116 4:00 p.m. 11:00 p.m. Monday Friday Dental Operatory 2 2116B 4:00 p.m. 11:00 p.m. Monday Friday Dental Operatory 2 2118B 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Office 2 2228 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Mail Room 2 2227 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Office 2 2226 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Lab 2 2224 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Conference 2 2222 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Washroom 2 2220 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Sterilizing 2 2221 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Office 2 2220B 4:00 p.m. 11:00 p.m. Monday Friday TB Lab Media Preparation 2 2219 4:00 p.m. 11:00 p.m. Monday - Friday TB Lab Fume Hood 2 2219 4:00 p.m. 11:00 p.m. Monday - Friday TB Lab Contamination 2 2217 4:00 p.m. 11:00 p.m. Monday - Friday TB lab Lab 2 2216 4:00 p.m. 11:00 p.m. Monday - Friday TB Lab EKR 2 2215 4:00 p.m. 11:00 p.m. Monday - Friday TB Lab Washroom 2 2215A 4:00 p.m. 11:00 p.m. Monday - Friday TB Lab Corridor 2 Corridor 4:00 p.m. 11:00 p.m. Monday - Friday Pharmacy Nursing 2 5202 4:00 p.m. 11:00 p.m. Monday Friday Animal Research Operating Room 2 8134 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Clean Linen 2 8134A 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8135 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Operating Room 2 8136 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Operating Room 2 8136A 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8138 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8140 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8141 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8145 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8147 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8148 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8102 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8104 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8105 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8106 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Operating Room 2 8107 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8108 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8111 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8113 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8115 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8117 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8118 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8119 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8120 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8122 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8123 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Lab 2 8124 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Feed Stock Room 2 8125 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 2 8131 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 5 C252 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 5 C253 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 5 C254 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 27 160 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 27 161 8:00 a.m. 4:30 p.m. Monday - Friday Animal Research Animal Quarters 27 162 8:00 a.m. 4:30 p.m. Monday - Friday Newington Quarterly Testing Hours of Work Service Secondary Bldg Room Typ Hours Days of Week SPS Soft Supply Storage 2E B144A 8:00 a.m. 4:30 p.m. Saturday SPS Decon 2E B156 8:00 a.m. 4:30 p.m. Saturday SPS Prep 2E B157 8:00 a.m. 4:30 p.m. Saturday SPS RMD Storage 2E 3100 8:00 a.m. 4:30 p.m. Saturday Newington Annual Testing Hours of Work Service Secondary Bldg Room Typ Hours Days of Week SPS Soft Supply Storage 2E B144A 8:00 a.m. 4:30 p.m. Saturday SPS Decon 2E B156 8:00 a.m. 4:30 p.m. Saturday SPS Prep 2E B157 8:00 a.m. 4:30 p.m. Saturday SPS RMD Storage 2E 3100 8:00 a.m. 4:30 p.m. Saturday Pharmacy Dispensing/Assembly 2C 2205 8:00 a.m. 4:30 p.m. Saturday Pharmacy Active Storage 2C 2207 8:00 a.m. 4:30 p.m. Saturday Pharmacy Prescription Receiving 2C 2204A 8:00 a.m. 4:30 p.m. Saturday Pharmacy Storage 2C 2121 8:00 a.m. 4:30 p.m. Saturday Pharmacy Prep 2C 2215 8:00 a.m. 4:30 p.m. Saturday Pharmacy Storage 2C 2214 8:00 a.m. 4:30 p.m. Saturday Pharmacy Storage 2C 2123 8:00 a.m. 4:30 p.m. Saturday Pharmacy Storage 2C 2126 8:00 a.m. 4:30 p.m. Saturday Pharmacy Vault 2C 2126A 8:00 a.m. 4:30 p.m. Saturday Dental Storage 2C 2115 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2101 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2112 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2110 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2109 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2108 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2107 8:00 a.m. 4:30 p.m. Saturday Dental Dental Lab 2C 2106 8:00 a.m. 4:30 p.m. Saturday Dental Exam Room 2C 2105 8:00 a.m. 4:30 p.m. Saturday Dental Accumulation Room 2C 2104 8:00 a.m. 4:30 p.m. Saturday Dental Accumulation Room 2C 2102A 8:00 a.m. 4:30 p.m. Saturday Dental Dental X-Ray 2C 2102 8:00 a.m. 4:30 p.m. Saturday HVAC Systems to be Air Balanced and HEPA DOP Tested West Haven Campus: Mechanical Air Handler Unit and Exhaust Equipment Schedule Building Room Service Area 1 6137M 6 East 1 5150 5 East and South MICU 1 5206 OR 2, 3, 6, 7 1 4260 OR 1, 5 1 4260 SICU 1 4181 4 West 1 10th Floor Endoscopy 1 2213B OR Storage and EMS Breakroom 1 2222 1st Floor Ultrasound AHU 5 1 2222 OR Locker and Library AHU 6 1 1207 IAQ 1 1218 Hematology 1229 1 Cardiology Roof Cath Lab 2 Room 1111 1 Nuclear Med Roof Cath Lab 1 Room 1115 1 Cardiology Roof 1st Floor Old Psych/ Cardiology 1 Subground SPS 1 Subground SPS 1 Pharmacy Roof Inpatient Pharmacy 1 SG174 SPD Unit 1 SG129 Ground Cardiology/ MRI 1 SS6 Morgue 2 9 Interior Animal Lab 2 8 Exterior Animal Lab Chiller 2 8 7 DNA Lab 2 6 Cancer Center 2 5185 5 West 2 2102 Pharmacy Corridor 2 2120 Dental 2 2113 Penthouse First AHU Front ER 2 2113 Penthouse Middle AHU Dialysis 2 2113 Penthouse End AHU ER Clinic 2 2200 TB Lab 2 G132 Electrical Lockup AHU 2 G139A New Orleans AHU 7 2 G139B AHU 5 2 G139 Switchgear Room 2 G142A Sterile Storage 2 6th Floor AHU 6 2 7th Floor AHU 1 HVAC Systems to be Air Balanced and HEPA DOP Tested Newington Campus: Lab AHU #1 and Exhaust Located B2E Basement SPS AHU #2 and Exhaust Located B2E Basement Dental AHU B2C Penthouse Pharmacy AHU C01 and Exhaust Located B2W Basement Negative Air Machines at West Haven Campus: VAMC West Haven has (10) negative air machines. The Service provider shall test these machines utilizing the following performance evaluation tests: In-place HEPA filter leak test, airflow volume test, and magnehelic gauge reading, where applicable. Filters shall be tested using aerosol challenge and aerosol photometer downstream filter probe test method. Individual equipment test reports shall be included in final report submittals. Make note on the reports if the filters and/or negative air machines fail to meet the manufacturers requirements for proper operation. Negative Air Machines at Newington Campus: VAMC Newington has (06) negative air machines. The Service provider shall test these machines utilizing the following performance evaluation tests: In-place HEPA filter leak test, airflow volume test, and magnehelic gauge reading, where applicable. Filters shall be tested using aerosol challenge and aerosol photometer downstream filter probe test method. Individual equipment test reports shall be included in final report submittals. Make note on the reports if the filters and/or negative air machines fail to meet the manufacturers requirements for proper operation. Unscheduled/Emergency Service Calls Requirements: Unscheduled service calls shall be performed at the direction of the VA Contracting Officer. The vendor and the VA Contracting Officer will agree on the Scope of Work and labor hours prior to the commencement of work. Emergency service and repairs shall be available on a 24 hour per day basis and will be invoiced at the prevailing straight time or overtime contract customer rate. Vendor shall submit the following associated with unscheduled service calls. Labor Hours: Minimum 6 Hours SUBMITTALS/DELIVERABLES The Service provider shall furnish Certificates of Calibration for all instruments used in conducting the balancing of systems and DOP testing of HEPA filters where applicable including, function, minimum range, minimum accuracy, minimum resolution, manufacturer, model, serial number, frequency of calibration, and date of last calibration. The Service provider shall furnish a detailed written report making special notations of variances from design quantities which exceed plus or minus ten percent of design specifications. The Service provider shall furnish Project Synopsis Detailed Written Report of performance test procedures, Equipment ID, and orientation drawings of each performance test and statistical data analysis with all findings and recommendations clearly called out. The Service provider shall submit two (2) hard copies and electronic copy of all maintenance, testing, and inspection data/reports to the COR within thirty (30) calendar days of completion of work. Billing subject to the receipt and acceptance of testing and reports per service unit. The contractor shall submit any waste manifest documents as applicable with final reports. Work hours and service calls for corrective maintenance shall be as follows: Normal routine service shall occur during normal business hours. 7:30 a.m. to 4:00 p.m., Monday through Friday. Correction/Emergency service shall be provided 24 hours, 7 days per week. During this period, corrective, emergency maintenance will be initiated by the VA Connecticut Healthcare System call to the contractor s service center, which must be acknowledged within 2 hours (per a call back to review details of concerns, suspect causes, and outcomes.) A fully qualified and competent service technician must be on site at the start of the next first shift on Monday Friday to address specific concerns. The equipment and its operation shall be restored to full service within two (2) hours of arriving on the job site, barring extenuating circumstances (e.g., required replacement parts). Full service means that defective parts have been replaced with parts that meet or exceeds the manufacturers original specifications and that the equipment meets or exceeds the manufacturers original performance specifications. c. Annual preventative maintenance work (90%) or better) shall be completed no less than one calendar month before the end of each annual contract period. d. Contractor shall cover all costs for preventative maintenance services for labor and materials (e.g. calibrations of gauges, valves, equipment settings, transmitters and controls including shipping, handling, and freight. e. All labor, materials, parts, and supplies for corrective/emergency maintenance will be paid for by the VA before the material is procured and/or the work is completed, or the contractor may be perceived as proceeding at risk. Contractor shall submit all proposals within two (2) working days of field assessment for determination of issue(s) and acceptance of corrective action plan. f. Authorization to procure and complete corrective/emergency maintenance work shall be per verbal or written direction of the VA Contracting Officer or per Purchase Order Number issuance upon approval and funding of cost for correction) and upon which the contractor shall provide all labor, parts, and or materials necessary for correction/emergency maintenance work. SPECIAL INSTRUCTIONS Contractor Check-in: All employees of the service provider shall comply with VA Security Management Program and obtain permission of the VA Police and restricted from unauthorized access. Upon arrival, the contractor shall sign-in at Building 15 and receive a temporary identification badge prior to performing services at VA Connecticut Healthcare System. The contractor shall wear visible identification always displaying the name and company ID while on site. All site visits shall be coordinated with the VA COR. Documentation: At the conclusion of each repair and scheduled maintenance visit, the contractor shall provide a written service report indicating the date of service, the model, serial number, and location of equipment serviced, the name of the representative, and the services performed, and parts replaced and labor hours. The reports shall be delivered within five business days. Per VA Directive 1805, smoking vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees. No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time. VA reserves the right to close down or shut down the facilities and order Service provider employees off the premises in the event of a national emergency. The Service provider may return to the site only with the written approval of the VA Contracting Officer. Prior to commencing work onsite, all Service providers and provider personnel shall furnish proof of receipt of required COVID vaccinations and boosters in compliance with current VHA Directives. Prior to commencing work onsite, all Service providers and provider personnel shall furnish proof of receipt of required Tuberculosis testing in compliance with VHA Directive 1131(5), dated June 04, 2021. Parking for Service provider and its employees shall be in designated areas only. Service provider to coordinate with COR. The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others. Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hourly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report. TERMS AND CONDITIONS User Responsibility: The contractor shall not be held responsible under the terms of this contract for repairs to equipment necessitated by user abuse and/or misuse of equipment. All work is subject to inspection, review and approval by the HVAC Supervisor, Utility System Supervisor, Chief M&O, Chief Engineer, and/or their designees. Evaluation Process Award will be made to the best price, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Vendors quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. The Government will award a contract resulting from this solicitation to the responsible vendor whose quote conforming to the solicitation will be most advantageous to the Government, price, past performance, and capabilities. The following factors shall be used to evaluate offers: 1. Price (Follow these instructions): a. Vendor shall provide a quote for the services above. Vendors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards (SCLS) if applicable. b. Ensure your validation is current in the System for Award Management (SAM)( https://www.sam.gov). Federal Acquisition...

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Jun 30, 2026

NAICS

238220

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24124Q0423
  1. Market Research
  2. Combined Synopsis
  1. Market ResearchApr 10, 2024

    H241--Airflow Testing (VA-24-00022718)

    Notice 8f30a39b33c34ba9a37fb73b70fd671a on SAM.gov

  2. Combined SynopsisCurrentMay 7, 2024

    J041--Airflow Testing (VA-24-00022718)

    Notice 72c496f514b343bba8517634a840ba35 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Page 2 of 2 Combined Synopsis Solicitation West Haven VAMC Steam Station Replacement (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 36C24127Q0058 and the solicitation is issued as a request for quotation (RFQ). (iii) A statement that the solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-05. (iv) This requirement is being issued as a SDVOSB set-aside. The associated NAICS 238220 and small business size standard is $16.5 million. (v) The Government intends to award a firm-fixed price award for Steam Station Replacement at West Haven VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission. (vi) The Contractor shall provide all resources necessary to provide Steam Station Replacement IAW the attached (PerformancevWork Statement). Please see the attached PWS for full requirement details. (vii) The Place of Performance is West Haven VAMC as described per the (Performance Work Statement). (viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018); 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5 Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) (ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement. Site Visit: 950 Campbell Ave, West Haven CT 06516 Bidders shall perform a pre-bid walkthrough at 8:30 a.m. on November 14, 2026 and plan to meet in the Building 16 Boiler Plant at the VA Medical Center West Haven and report for a safety briefing. Bidders shall be responsible to comply with the VA Connecticut Healthcare System Medical Center Policy 138-075 for Lock-Out-Tag-Out and VA Connecticut Healthcare System Confined Space Entry Program SOP SO-010.   Please post and include MCP 138-075 Lock-Out-Tag-Out Policy and Confined Space Entry Program. Bidders are required to comply with this policy and SOP. Submission of Quotes: (1) Quotes shall be received on or before the date and time specified in Section (xv) of this solicitation. Note: Offers received after the due date and time shall not be considered. (2) Offerors shall submit their quotes electronically via email to tnauri.woodbridge@va.gov. (3) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer. Evaluation Process: Award shall be made to the best value, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. Therefore, the Government is not obligated to determine a competitive range, conduct discussions with all contractors, solicit final revised quotes, and use other techniques associated with FAR Part 15. The Government shall award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation shall be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Price (Follow these instructions): Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces. Past Performance: Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work. The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. Technical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner. Contractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement). Contractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement). If you are planning to sub-contract some or all of this work, please provide the name and address(s) of all subcontractor(s) (if applicable) and a description of their planned subcontracting effort. SAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can request a Form 10091 at any time. (x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy. (xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC 2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of Payment Requests (NOV 2018) Subcontracting Commitments - Monitoring and Compliance This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor Commitments. Accordingly, any contract resulting from this solicitation will include these clauses. The contractor is advised in performing contract administration functions, the CO may use the services of a support contractor(s) to assist in assessing contractor compliance with the subcontracting commitments incorporated into the Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement to ensure the contractor's business records or other proprietary data reviewed or obtained in the course of assisting the CO in assessing the contractor for compliance are protected to ensure information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA determines any services the support contractor(s) will perform in assessing compliance are advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s) must also enter into an agreement with the contractor to protect proprietary information as required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The contractor is required to cooperate fully and make available any records as may be required to enable the CO to assess the contractor compliance with the subcontracting commitments. (xiii) All contract requirement(s) and/or terms and conditions are stated above. (xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable to this requirement. (xv) RFQ responses are due December 3, 2026 by 10:00 AM EST. RFQ responses must be submitted via email to: tnauri.woodbridge@va.gov. Hand deliveries shall not be accepted. (xvi) The POC of this solicitation is Tnauri.Woodbridge@va.gov) ATTACHMENT 1 PRICE SCHEDULE ITEM NUMBER DESCRIPTION OF SERVICES QUANTITY UNIT UNIT PRICE AMOUNT Base REPLACE BUILDING 2 STEAM STATION 1.00 JB __________________ __________________ GRAND TOTAL __________________ ATTACHMENT 2 PAST PERFORMANCE WORKSHEET 1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization: 2. Contracting Activity Address: 3. Contract Number: 4. Date of Contract Award: 5. Beginning Date of Contract: 6. Completion Date of Contract: 7. Contract Value: 8. Type of Contract: 9a. Technical Point of Contact: 9b. Contracting Point of Contact: Name: Name: Title: Title: Address: Address: Telephone: Telephone: Email: Email: 10. Place of Performance: 11. Description of Work (Use a continuation sheet if necessary): 12. List any commendations or awards received: 13. List of Major Subcontractors: ATTACHMENT 3 STATEMENT OF WORK STATEMENT OF WORK REPLACE BUILDING 2 STEAM STATION VA CONNECTICUT HEALTHCARE SYSTEM (VACHS) VA MEDICAL CENTER WEST HAVEN 950 CAMPBELL AVENUE WEST HAVEN, CT 06516 BACKGROUND VA Connecticut Healthcare System has identified existing steam pressure reducing stations that are currently non-functional and require complete replacement (like in kind) located in Building 2, Confined Space 15 within Mechanical Room G-139. JUSTIFICATION Steam station failure has been identified to be impacting inpatient and critical care areas during winter months. Heating restoration to critical patient care areas is essential to compliance with health and safety standards, patient care, and prevention of domestic and fire suppression piping failures. PLACE OF PERFORMANCE The place of performance for this contract is VA Connecticut Healthcare System, West Haven VA Medical Center located at 950 Campbell Avenue; West Haven, CT 06516. PERIOD OF PERFORMANCE The Contract Time Period of Performance will be 180 days upon contract award and Notice to Proceed (NTP). QUALIFICATIONS To be considered eligible for consideration, potential bidders shall have a field service representative located within 100 miles of the West Haven Campus of the VA Connecticut Healthcare System. Bidders shall provide upon request, documentation of certification/training on the specific equipment under the terms of this contract. Bidders shall be qualified to perform work on steam distribution systems to include industrial boiler plant equipment and have completed prior steam distribution work and/or inspection projects for VA Connecticut Healthcare System. Service Provider shall have a minimum of three (3) years of related scope and work experience with commercial and industrial steam boiler and steam boiler component installation and repairs as well as all aspects of inspections, cleaning, calibration, and testing in compliance with and clear understanding of relevant codes and regulations. Service Provider and/or assigned project staff members shall have industry standard certifications and qualifications to include but not limited to current OSHA 30 and OSHA 10 certification and equivalent qualifications associated with requirements herein. Service Provider shall submit documentation of technical training and certifications for personnel performing all work under the terms of this contract for review and acceptance prior to the start of work on site. Bidders shall be evaluated on past performance, technical capability, and financial capability to perform the requirements of this work. A full boiler plant steam outage will be conducted prior to the start of this work. Work is expected to be completed over the duration of two consecutive back to back boiler plant steam outages occurring Saturday 7:00 a.m. through Sunday 4:00 p.m. and will be coordinated between March 01, 2027 and May 31, 2027 and with a 30 day notice. Mandatory Pre Bid: Bidders shall perform a pre-bid walkthrough at 8:30 a.m. on November 14, 2026 and plan to meet in the Building 16 Boiler Plant at the VA Medical Center West Haven and report for a safety briefing. Bidders shall be responsible to comply with the VA Connecticut Healthcare System Medical Center Policy 138-075 for Lock-Out-Tag-Out and VA Connecticut Healthcare System Confined Space Entry Program SOP SO-010. During the pre-bid site visit, each bidder shall thoroughly inspect the work area and familiarize themselves with all existing conditions affecting the work. At minimum, bidders shall verify: Existing steam pipe sizes. Existing 1/3 and 2/3 station pipe sizes. Existing regulator sizes. Existing valve sizes. Existing flange sizes, types, ratings, and configurations. Existing strainer sizes and configurations. Existing safety relief valve sizes and configurations. Existing pressure gauge arrangements. Existing condensate and drip piping. Existing support arrangements. Existing piping elevations. Available straight-pipe distances upstream and downstream of regulators. Existing cross tee configuration. Available physical space for the new steam station arrangement. Access into and out of the pit/crawl space. Confined-space access conditions. Rigging requirements. Material handling requirements. Removal path for demolished materials. Installation path for new materials and equipment. Working clearances. Existing interference with piping, structure, ductwork, electrical, equipment, or other utilities. Equipment access requirements. Existing insulation. Existing asbestos-containing or suspect materials. Flanges containing square-head bolts. Existing pipe supports and structural attachment points. Required temporary supports. Required permanent supports. Required access for future service and adjustment. Pressure gauge visibility from outside the pit/crawl space. Conditions affecting off-hours work. Conditions affecting the scheduled steam shutdown. All pipe sizing, valve sizing, equipment sizing, dimensions, elevations, quantities, access requirements, and existing conditions shall be field verified by the bidder prior to submitting their proposal. Dimensions, sizes, and quantities contained within this Scope of Work are intended to describe the general work and shall not relieve the bidder from field verification. The bidder s submission of a proposal shall constitute acknowledgement that the bidder has inspected the existing conditions, understands the location and complexity of the work, and has included the work reasonably apparent or discoverable during the site visit within their bid price. All Confined Space Entries shall be in compliance with the VA Connecticut Healthcare System Standard Operating Procedure Confined Space SOP-SO-010. Work shall be conducted during WHEN hours. A dedicated steam outage will be scheduled to perform this work to be included. SCOPE OF WORK The Service Provider shall furnish all labor, materials, equipment, tools, supervision, and incidentals to complete work for the services described in this document. The intent of this Scope of Work is to provide a complete turnkey installation. The Service Provider shall furnish all labor, supervision, engineering/coordination, materials, equipment, tools, rigging, temporary protection, safety equipment, permits, testing, startup, commissioning, disposal, and incidental work required to compete the installation whether or not every individual fitting, component, support, connection, or accessory is specifically identified within this Scope of Work. The Service Provider shall submit a project schedule, work procedures, inspection procedures, testing procedures, all safety documentation, weld procedures, welder s certifications, etc. for review and approval by VA Contracting Officer Representative and Safety Office before work commences on site. Description of Services: Service Provider shall schedule and coordinate all work with VA COR, Utilities Supervisor, and Boiler Plant Supervisor. All LOTO request and procedures shall be in compliance with the VA Connecticut Healthcare System Medical Center Policy 138-075. Coordinate Hot Work permit requests with VA Connecticut Healthcare System Safety Service. Coordinate all placement and removal of Lock Out Tag Out devices for any energy sources with the VA COR/Maintenance & Operations. All Confined Space Entries shall be in compliance with the VA Connecticut Healthcare System Standard Operating Procedure Confined Space SOP-SO-010. Coordinate Hot Work Permit with VA Connecticut Healthcare System Occupational Health/Safety Service. Complete Infection Control Risk Assessment (ICRA) and coordinate with COR and Medical Center Infection Prevention for approval. Furnish and install required barrier(s) as required per the Infection Control Risk Assessment (ICRA). Protect all equipment in place during replacement activities. In accordance with VHA Operational Alert and Guidance, NO cast iron fittings and pipe components (valves, steam traps, etc.) shall be used. Reference VHA Directive 1810(1) as amended on September 11, 2018: 5.a(1) and 5.b(1). ASTM A193 bolts shall be utilized and replace any ASTM A307 Bolts at locations of steam piping, flanges, gaskets, and other hardware where piping replacements are included within this scope of work. Reference Veterans Health Administration (VHA) Master Specifications for Hydronic Piping (Specification 23 22 13) and Steam and Condensate Heating Piping (Specification 23 22 13) where applicable. Repair of existing cast iron fittings or pipe components is permissible in specific instances but must be reported and coordinated with the CO and COR for approval before starting the work through submittal process with justification as necessary. All new steam and condensate line shall be Schedule 80. All new steam and condensate lines that utilize valves to isolate or divert a medium shall be installed new as a double in series valve system. Where the option exists to utilize welded vs threaded. Tag all existing and new valves and label new piping and components replaced as part of this scope of work. Service provider shall perform all acceptance testing. Facilities Management Service shall designate a staff member to witness acceptance testing of all components and completed work. Service provider shall clean up work area and all debris. Service provider shall provide a complete, fully operational, code-compliant replacement of the existing 1/3 and 2/3 steam pressure reducing stations located within the existing crawl space in Building 2 at the West Haven VA Medical Center. Existing Conditions: The existing steam pressure reducing stations are currently non-functional and require complete replacement. Known existing conditions include: Existing 2-inch steam pressure reducing station is non-functional. Existing 2-1/2-inch steam pressure reducing station is non-functional. Both existing steam regulators are to be replaced. Existing steam stations are not presently installed in accordance with the required regulator manufacturer's piping arrangement. Existing cross tee is leaking and shall be removed and replaced. Existing pressure gauge arrangement does not allow convenient observation from outside the pit/crawl space. Existing downstream safety relief valves shall be replaced. Existing flanged connections utilizing square-head bolts have been identified as containing or potentially containing asbestos-containing material. Work is located within a restricted-access pit/crawl-space environment. These descriptions are not intended to represent every existing field condition. The bidder is responsible for identifying additional conditions that are visible, reasonably apparent, or reasonably discoverable during the mandatory pre-bid walk. Steam Pressure Reducing Station Replacement: Service provider shall remove existing 1/3 and 2/3 steam pressure reducing stations as required to accommodate the new installation. Service provider shall furnish and install new pressure reducing stations serving the exiting steam system. Remove existing steam regulators. Remove associating piping necessary to properly rebuild the stations. Remove the leaking cross tee. Remove existing components that prevent compliance with manufacturer required piping arrangements. Furnish and install new steam regulators. Furnish and install new upstream and downstream piping. Furnish and install new fittings and tees. Furnish and install new flanges, gaskets, and flange bolting. Furnish and install unions or breakable connections where appropriate. Furnish and install strainers where required. Furnish and install isolation valves where required by the station configuration. Furnish and install condensate/drip provisions where required. Furnish and install required pipe supports. Modify or replace of existing pipe supports as required. Furnish and install temporary support of existing piping during demolition and installation. Reconnect all existing steam piping. Furnish and install all miscellaneous piping modifications necessary for the completed installation. Steam stations shall be installed in accordance with the selected steam regulator manufacturer s current installation requirements. The contractor shall verify and provide the manufacturer s required: Upstream straight-pipe distance. Downstream straight-pipe distance. Valve arrangement. Strainer arrangement. Pressure sensing arrangement. Drip-leg arrangement. Condensate removal provisions. Gauge locations. Bypass configuration, if required. Regulator orientation. Service clearances. Maintenance clearances. Safety relief requirements. Existing conditions shall not be used as justification for installing the new regulators contrary to manufacturer requirements. Where existing piping must be reconfigured to meet manufacturer requirements, the required reconfiguration shall be included in the base bid. Equipment and Pipe Sizing: All equipment and piping sizes shall be verified prior to bidding and again prior to procurement. The contractor shall verify: Existing pipe sizes. Required regulator inlet size. Required regulator outlet size. Required regulator capacity. Required steam pressure. Required downstream pressure. Required steam flow. Safety valve capacity. Safety valve set pressure. Strainer sizing. Valve sizing. Flange pressure class. Pipe schedule. Applicable steam pressure and temperature ratings. The contractor shall provide steam regulators properly sized for the actual system operating conditions. The contractor shall not assume that the existing regulator size is automatically the correct replacement size. Where required, the successful bidder shall coordinate with the regulator manufacturer or authorized representative to confirm the proper regulator selection. Manufacturer Requirements Prior to installation, the contractor shall provide manufacturer documentation demonstrating that the proposed steam regulators are suitable for the application. The completed station shall comply with all manufacturer requirements. Pressure Gauges Provide new pressure gauge arrangements servicing the steam pressure reducing stations. Pressure gauges shall be located and piped so that normal operating pressures can be clearly viewed from outside confined space number 15 without requiring personnel to enter the confined space for routine pressure observation. Steam-rated gauge. Gauge siphon. Isolation valve. Piping and fittings. Supports. Identification. Appropriate protection from damage. Gauge piping shall be securely supported and arranged so that it does not create an obstruction or interfere with access. Gauge locations shall be coordinated and approved prior to final installation. Safety Relief Valves Remove and replace the existing downstream steam safety relief valves associated with the pressure reducing stations. Provide new safety relief valves properly selected and sized for the actual system conditions. The contractor shall verify: Required relieving capacity. Inlet pressure. Downstream operating pressure. Safety valve set pressure. Valve inlet size. Valve outlet size. Discharge pipe size. Required discharge arrangement. Safety valves and discharge piping shall comply with applicable codes, VA requirements, and manufacturer requirements. Modify, replace, extend, support, or reconnect the existing safety valve discharge piping as necessary for a complete installation. The contractor shall include all piping modifications required between the new safety valves and the existing approved discharge termination. Cross Tee Replacement Remove the existing leaking cross tee. Provide new steam-rated piping and fittings necessary to eliminate the existing leaking tee and provide a permanent repair. The bidder shall verify the existing tee size, orientation, connections, and piping arrangement during the mandatory pre-bid walkthrough. All associated piping modifications required to complete this work shall be included. Pipe Supports Provide all new or modified supports required for the new piping arrangement. Supports shall be suitable for steam service and shall account for: Pipe weight Valve weight Regulator weight Strainer weight Safety valve weight Thermal expansion Operating loads Maintenance loads Existing equipment shall not be improperly used as a pipe support. Any temporary supports necessary during demolition and installation shall be included. Insulation Remove existing insulation as necessary to perform the work. Provide new insulation at all disturbed or newly installed piping after successful testing and startup. New insulation shall match the applicable VA specification requirements for steam service. All damaged insulation associated with the contractor s work shall be repaired or replaced. Asbestos Abatement Existing flanged connections utilizing square-head bolts have been identified as Potential Asbestos Containing Material (PACM). Bidders shall make proper required abatement notification(s), obtain required permit(s) and licensed asbestos abatement professional and VPIH services for air quality monitoring to perform removal of flanges with PACM. Wrap existing flanges for removal and wet cut existing piping on each side of flange to dismantle in-tact flange. Dispose of flanges as ACM. Abatement work shall meet State of Connecticut and local jurisdiction requirements for Asbestos Abatement. Rigging and Material Handling: The contractor shall include all rigging and material handling required to remove existing equipment and install new equipment. The bidder shall determine the appropriate means and methods during the pre-bid inspection. Restrictions associated with equipment access or material movement that are visible or reasonably discoverable during the pre-bid walk through shall be included in the bid. Testing: Following installation, test all newly installed or modified piping and equipment in accordance with applicable codes, VA specifications, and manufacturer requirements. Testing shall include as applicable: Pressure testing Leak testing Flange inspection Valve inspection Regulator inspection Gauge verification Safety valve verification Repair any leaks or deficiencies associated with the new work at no additional cost to the government. Startup and Commissioning: Following completion of the installation: Start the steam system in coordination with the VA Maintenance & Operations Supervisor and Boiler Plant Supervisor. Verify proper regulator operation. Adjust regulators to the required operating pressures. Set the 1/3 station. Set the 2/3 station. Verify proper transition and operation between the two regulators where applicable. Verify downstream pressures. Verify gauge readings. Verify valve operation. Verify safety valve installation. Verify proper condensate drainage. Inspect all new piping and connections for leakage. Make final adjustments required for proper system operation. The steam station shall not be considered complete until both stations are demonstrated to be operational and accepted by the VA COR and Contracting Officer. VA Specifications and Code Compliance: All materials and workmanship shall comply with the applicable VA project specifications, including applicable VA Division 23 requirements, as identified by the project scope. Materials: All materials shall be new unless specifically approved otherwise. Materials shall be properly rated for steam service, system pressure, system temperature and applicable pressure class. Substitutions shall not be made without approval. Demolition and Disposal Remove all demolished and discarded materials associated with this work from the project site. Dispose of materials legally at an approved facility and furnish a waste manifest as required by Local, Federal, and VA requirements and regulations. The work area shall be broom-clean and free of construction debris following completion. Protection of Existing Conditions: The contractor shall protect all existing facilities, equipment, piping, structure, and finishes adjacent to the work. Any damage caused by the contractor shall be repaired at the contractor s expense. The bidder shall include reasonable temporary protection required to perform the work. Bidder Responsibility for Complete Scope: The bidder is responsible for providing a complete turnkey price based on: This Scope of Work Mandatory Site Inspection Existing Field Conditions Applicable VA Requirements Applicable Codes Manufacturer installation requirements Proper methods of constructing assemblies associated with the Scope of Work. The bidder shall include all miscellaneous and incidental work reasonably required to provide a complete and operational installation. The absence of an individual fitting, spool piece, support, gasket, bolt, valve, connection, accessory, rigging item, or similar incidental component from the written Scope of Work shall not constitute grounds for additional compensation when that item is reasonably necessary to complete the described work. Bid Clarifications and Exceptions: Any ambiguity, discrepancy, conflict, unusual condition, or concern identified by a bidder shall be submitted in writing prior to bid submission to the VA Contracting Officer. Any requested exclusions or exceptions shall be clearly identified in the bid. Failure to identify an exception shall indicate that the bidder has included the requirement within their base price. The successful bidder shall not rely upon assumptions that contradict conditions observable during the mandatory site walk or the requirements contained in this Scope of Work. SUBMITTALS/DELIVERABLES Service provider shall furnish all submittal item documentation with final dispositions and final documentation report with all tests, photos, and work completed within 10 business days following completion of work. Service provider shall furnish all material certifications for any replacement parts used. Service provider shall furnish a waste manifest as required. SPECIAL INSTRUCTIONS All service provider personnel, sub-service providers and representatives visiting VA sites will be required to sign in upon arrival at Building 15 and/or retain a temporary VA badge. Each visiting individual be required to enter their name, their company s name, VA project title, reason for visit, and the times of arrival and departure. Arrangements for after normal hour working site visits must be made in advance and during normal working hours. General: The Contracting Officer reserves the right to terminate any services, without payment for services completed, if such services are not needed or are not being adequately completed. Approved Plans and Permits: Prior to the start of work, submit to VA copies of all required permits. Site Visits: Day to day project administration will be performed by the COR. Periodic reviews, tests, and other field observation by the Government are not to be interpreted as superintendence nor as resulting in any approval of the service provider s apparent progress toward meeting the Government s objectives; but are intended to discover any information that the Contracting Officer may be able to call to the service provider s attention to prevent costly misdirection of effort. The service provider shall remain responsible for constructing, operating, and maintaining the site in full accordance if the requirements of this solicitation. The service provider shall provide VA with a copy of all inspection reports for inspections conducted by local, regional, and state code authorities from the start of work through issuance of the certificate of completion. The service provider shall develop and provide to the VA the following: Safety Plan: The service provider shall produce work in accordance with the latest editions of all applicable DVA guidelines (e.g. Construction Standards, Master Specifications, Standard Details, Special Design Criteria to meet Hospital Joint Commission (JCAHO) requirements), NFPA, Federal and State codes pertinent to the project scope. All applicable personnel on site are required to obtain an Occupational Safety and Health Administration (OSHA) 10 hour construction certification, and the site competent person for the service provider must obtain an OSHA 30 hour construction certification. Per VA Directive 1805, smoking vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees. No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time. Parking for Service provider and its employees shall be in designated areas only. Service provider to coordinate with COR. The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others. Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hourly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report. Safety Codes / Certification / Licensing: Environmental abatement work, if necessary, is to be performed by Service provider under supervision and monitoring for the VA by a Certified Industrial Hygienist. The Service provider shall comply with all codes as described above, as well as codes customarily applied in VA construction jobs such as NFPA fire code, OSHA, VA Design Guides, ASME, Manufacturer Requirements, etc. Labs used by the service provider shall be licensed as required by any applicable governing agencies, and their certifications and licenses shall be included in the reports. The C&A requirements do not apply and a Security Accreditation Package is not required. NARA Records Management Requirements The following standard items relate to records generated in executing this contract: Citations to pertinent laws, codes and regulations such as 44 U.S.C. Chapter 21, 29, 31, and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228. Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records. Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act. The Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract. The Government Agency owns the rights to all data/records produced as part of this contract. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data. The Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.]. No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage, or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules. The Contractor is required to obtain the Contracting Officer s approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under or relating to this contract. The Contractor (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.
-Combined Synopsis12/03/2026
-Pre-Solicitation09/08/2026
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 12.201-1, Simplified procedures. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. The Department of Veterans Affairs, Network Contracting Office (NCO) 8, located at VA Caribbean Healthcare System (VACHS), is seeking to award a single firm-fixed-price requirements type contract for Preventive Maintenance and Repair Services for HVAC Water Chillers and Air Handling Units (AHUs) at the VA Caribbean Healthcare System (VACHS) . This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, effective on March 13, 2026 (and as supplemented by VA Deviations). TIERED EVALUATION. This solicitation will be evaluated using a tiered evaluation approach (also known as cascading set asides). The tiers for this procurement are: 1st Tier- Service-Disabled Veteran-Owned Small Business (SDVOSB) 2nd Tier- Small Business Evaluation will begin with the first tier. If the Government receives two or more acceptable quotes from the first tier, the evaluation will not proceed to the next tier. If fewer than two acceptable quotes are received at a given tier, the Government may proceed to evaluate the next tier. The associated North American Industrial Classification System (NAICS) code for this procurement is 238220, Plumbing, Heating, and Air Conditioning Contractors. The applicable small business size standard is $19,000,000. The Product Service Code (PSC) is J041, Maintenance, Repair, and Rebuilding of Equipment - Refrigeration, Air Conditioning, and Air Circulating Equipment. Detailed specifications and requirements are provided in the attached Performance Work Statement (PWS), Instructions to Quoters, Price/Cost Schedule, Clauses, and Provisions. The resulting contract will include a five-year ordering period. In addition, RFO Clause 52.217-8, Option to Extend Services, is included in the RFQ. Place of Performance San Juan Address: VA Caribbean Healthcare System 10 Casia St. San Juan, PR The full text of the RFO provisions or clauses may be accessed electronically at https://www.acquisition.gov/far-overhaul. The following solicitation provisions apply to this acquisition: RFO 52.212-1, Instructions to Offerors Commercial Products and Commercial Services. , [Sep 2023] [Deviation Nov 2025), including an addendum to this provision. Offerors shall carefully read the addendum, which provides further information regarding this requirement and the minimum information/documentation that shall be submitted with the quote. Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal. The following contract clauses apply to this requirement: RFO 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services [Nov 2023] [Deviation Nov 2025](Addendum attached). See clauses in the attached document titled "S02 Attachments B_C_D_E RFQ 36C24826Q0366_PM Chillers and AHUs_25 June 2026 The contract award will be based upon a comparative evaluation of quotes in accordance with the evaluation process outlined in the RFO 12.203(c)(2). Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government. To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows: "The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition." OR "The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:" Quoters shall list exception(s) and rationale for the exception(s), if any. SITE VISIT. A site visit has been scheduled for December 1, 2026, at 10:00 AM. The meeting point will be at the VA San Juan Medical Center main entrance, next to the Police Station. Vendors interested in participating in the site visit shall send an email to Baryan Sierra at baryan.sierrapierluissi@va.gov with the participant names (maximum 2 per company). QUESTIONS SUBMISSION. Questions regarding this acquisition shall be emailed to the Contracting Officer, Baryan Sierra, at baryan.sierrapierluissi@va.gov. All questions shall be submitted as a Word document. All questions are due on December 7, 2026, at 10:00 AM (Puerto Rico Local Time). Questions submitted after the due date may not be considered by the Government. The Quote shall be received no later than January 12, 2027, at 10:00 AM (Puerto Rico Local Time) to Baryan Sierra at baryan.sierrapierluissi@va.gov. Late submissions shall be treated in accordance with the solicitation provision at RFO 52.212-1(c). The following attachments are part of this combined synopsis-solicitation:
-Combined Synopsis01/12/2027
This is a combined synopsis/solicitation for commercial services prepared in accordance with FAR Part 12, Acquisition of Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate solicitation will not be issued. Solicitation is issued as a Request for Quotation (RFQ) for Metasys Building Automation System (BAS) Controls Services for the Michael E. DeBakey VA Medical Center (MEDVAMC), Houston, Texas. The requirement consists of providing all labor, supervision, OEM-authorized technical support, tools, software, transportation, training, and management necessary to perform operation, maintenance, troubleshooting, repair, programming, calibration, optimization, database management, reporting, and support services for the Government-owned Johnson Controls Metasys Building Automation System and associated HVAC Building Service Equipment. This acquisition is being conducted as a 100 percent Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS 238220, Plumbing, Heating, and Air-Conditioning Contractors. The principal purpose of this acquisition is the provision of commercial building automation system (BAS) and HVAC controls operations, maintenance, troubleshooting, programming, optimization, repair, calibration, reporting, training, and technical support services for an existing Government-owned Johnson Controls Metasys Building Automation System and associated Building Service Equipment. Although classified under NAICS 238220, this acquisition is being solicited and administered as a commercial services contract and is not a construction contract. This acquisition does not limit competition to Johnson Controls as the prime contractor. Competition is permitted among eligible SDVOSBs capable of providing the required services, including through documented arrangements for necessary OEM support, software access, training verification, and compatible parts. Because performance necessarily requires support of the Government-owned Johnson Controls Metasys system, the contract file includes the applicable justification supporting use of Metasys-specific features and compatibility requirements. The solicitation documents and incorporated provisions and clauses are those in effect through Revolutionary FAR Overhaul (RFO) (effective 03/16/2026), FAC 2026-01 (effective 03/13/2026), FAR Deviation APR 2026 (effective 04/23/2026), VAAR Deviation OCT 2026 (effective 10/01/2026), VAAM Alert 26-01 (effective 10/01/2025), and Acquisition Policy Flash 27-02 (effective 10/01/2026). The solicitation incorporates provisions and clauses by reference. The full text of clauses and provisions may be accessed at Acquisition.gov. Offerors shall be actively registered in the System for Award Management (SAM) and, at the time of offer submission and award, be verified as an SDVOSB through SBA VetCert. Failure to maintain required registration and certification may render a quotation ineligible for award. The Government intends to award a single-award Firm-Fixed-Price contract consisting of a 12-month base period and four (4) 12-month option periods, NTE five (5) years. The attached solicitation provides: Description of the services required. Contract Line-Item Numbers (CLINs), quantities, and units of measure. Evaluation factors and award methodology. Applicable contract clauses and provisions. Proposal preparation instructions. Security, personnel qualification, and OEM authorization requirements. Submission instructions, due date, and points of contact. Period and Place of Performance: Place of performance: Michael E. DeBakey VA Medical Center 2002 Holcombe Boulevard Houston, Texas 77030 Period of performance: Base Year: 03/01/2027 - 02/29/2028 Option Year 1: 03/01/2028 - 02/28/2029 Option Year 2: 03/01/2029 - 02/28/2030 Option Year 3: 03/01/2030 - 02/28/2031 Option Year 4: 03/01/2031 - 02/29/2032 Response Date and Time: Quotations shall be submitted electronically no later than the date and time stated in this notice and solicitation. Questions regarding this solicitation shall be submitted electronically no later than the date and time stated in this notice and solicitation in writing to: Shasta M. Britt, Contracting Officer Email: Shasta.Britt@va.gov (End of Combined Synopsis/Solicitation Description)
-Combined Synopsis12/17/2026
-AwardedOpen

Additional Details

Solicitation Number

36C24124Q0423

Archive Date

Jun 1, 2024

Office Address

TOGUS, ME, 04330