Notice ID: a69ce57fbe12484781c5dc1a4688421eSpecial NoticeArchived
C1DA--402-25-008 Repair Condensate Pump Room Roof
Archived on September 25, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:30 PM EDT
- Posted
- May 27, 2025
- Notice type
- Special Notice
Notice details
- Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241)
- Place of performance
- VAMC Togus 1 VA Center, Augusta, ME, 04330
- Last updated
- Nov 14, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24125R0058
- Notice ID
- a69ce57fbe12484781c5dc1a4688421e
Description
Request For Qualifications Statements (SF 330) General Project Description: Project Number: 402-25-008 Project Title: A-E Repair Condensate Pump Room Roof Location of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330 A/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project. NAICS and Set-Aside Information: This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB). Key Dates: Period of Performance: 120 calendar days. Questions Due: 06/06/2025 4:30 PM EST. SF 330 Package Due: 06/27/2025 4:30 PM EST. Instructions: See attached Request for Qualification Statement (SF330s) for submission requirements.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 3Version 3Special NoticeArchivedCurrent
C1DA--402-25-008 Repair Condensate Pump Room Roof
Other notices for this solicitation
- Market ResearchRelated noticeJan 27, 2025
C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C24125R0058
Archive Date
Sep 25, 2025