Notice ID: 0ca02e89e6d54d4f9529207f01e3600fCombined Synopsis/SolicitationArchived
Z1DA--Repair Compressor for AHU 21 Chiller
Archived on June 18, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 5:00 PM EDT
- Posted
- May 5, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241)
- Place of performance
- Togus VAMC, Augusta, ME, 04330
- PSC
- Z1DA: MAINTENANCE OF HOSPITALS AND INFIRMARIES
- Last updated
- Oct 30, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24126Q0426
- Notice ID
- 0ca02e89e6d54d4f9529207f01e3600f
Description
Combined Synopsis-Solicitation for Commercial Products and Commercial Services Effective Date: 04/18/2025 Revision: 02 THE PURPOSE OF THIS AMENDMENT IS TO: 1. Schedule site visit 14, May 2026 at 10:00 AM Togus VA Medical Center 1 VA Center Augusta, ME 04330 Building B200E POC: Abigail Campbell 2.Respond to question received: I am writing to request clarification regarding the compressor replacement for AHU 21 Chiller. Specifically, we would like to confirm whether the compressor can be isolated during the replacement process, or if the addition of new refrigerant will be required. Isolating the compressor during replacement is not possible. The refrigerant from the entire circuit must be recovered and, because of the nature of the failure, cannot be reused. Additionally, during installation, the oil equalizer line will need to be drained, and fresh oil should be added to the circuit to ensure proper system functionality 3. Extend the submission due date Submission of your response shall be received not later than Tuesday, 19 May 2026 by 5:00 PM EST. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Point of Contact Kenya.Mitchell1@va.gov
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (7)
- Download
36C24126Q0426 0001.docx
18 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
FAR 852.219-75-Limitation on Subcontracting.pdf
316 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
FAR 52.212-2-Evaluation Commercial Products and Commercial Services.pdf
132 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
FAR 52.212-1-Instructions to Offerors Commercial Products and Commercial Services.pdf
169 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
Attachment -PIV Badge Template.pdf
293 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
Attachment - Togus Campus Map.pdf
255 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
36C24126Q0426.docx
34 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
Z1DA--Repair Compressor for AHU 21 Chiller
- 3Version 3Combined Synopsis/SolicitationArchivedCurrent
Z1DA--Repair Compressor for AHU 21 Chiller
Similar Opportunities
Additional Details
Solicitation Number
36C24126Q0426
Archive Date
Jun 18, 2026
Office Address