Description
This notice is being published in accordance with RFO Part 5.101, requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole-source contract pursuant to 10 U.S.C 2304 (C)(1), as implemented by FAR 6.103-1, 6.104, only one responsible source, and no other supplies or services will satisfy agency requirements, and brand-name descriptions. The Department of Veterans Affairs Medical Centers located in the VISN 1 Healthcare System have a requirement for Alaris Service and Maintenance The Government intends to award a firm-fixed-price sole source contract. A determination by the Government not to compete with this proposed contract based upon responses to this notice is solely within the discretion of the Government. This notice of intent is not a request for competitive proposals. This is a written notice to inform the public of the Government's intent to award on a sole source basis. Interested parties may identify their interest and capability to respond to the requirement. Any response to this notice must show clear and convincing evidence that competition will be advantageous to the Government. Please contact Manases Cabrera, Contracting Specialist, with the responses or questions regarding this requirement at manases.cabrera@va.gov. This notice will close on September 4, 2026, at 2:00 PM Eastern Standard Time (EST) ALARIS SUPPORT PROGRAM PERFORMANCE WORK STATEMENT The purpose of this procurement is to acquire infusion pump software management services (SMS) for use in the VA New England Healthcare System (all eight VISN 1 Healthcare Systems). The Contractor shall provide all software management services required to maintain and operate the Alaris Infusion System from BD (formerly CareFusion), currently located at the Boston-Jamaica Plains campus. BD will provide its Alaris Support Program. BD Technical Support Center is available Monday through Friday, 5 AM 5 PM PST, to provide immediate remote support. BACKGROUND Software management services for the Alaris Infusion System include software enhancements to server-based Alaris Infusion System software components; services that include internet, webinar, and on-site training and clinical education; support ranging from remote monitoring of the Alaris Systems Manager to technical support for the Alaris Infusion System; and include collection of data and providing analytics tools and services. Software enhancements do not include software updates or hardware upgrades to infusion devices. The following components comprise the Alaris Infusion System located throughout VA New England Healthcare System for this requirement. Table 1. Alaris Infusion System Components VA Medical Device Nomenclature System (VAMDNS) Category Model INFUSION PUMPS: MULTITHERAPY: SYRINGE ALARIS SYR MODULE 8110 INFUSION PUMPS: MULTITHERAPY ALARIS PUMP MODULE 8100 INFUSION CONTROLLERS ALARIS PC UNIT 8015 INFUSION PUMPS: ANALGESIC: PATIENT-CONTROLLED ALARIS PCA MODULE 8120 MONITORS: PHYSIO: EXHALED CO2: BEDSIDE/INTRAOP ALARIS ETCO2 MODULE 8300 NETWORKED SERVERS: MEDICAL Alaris Systems Manager; BD Care Coordination Engine SOFTWARE: MEDICAL Guardrails Suite MX; Guardrails Editor; Infusion Knowledge Portal; Alaris System Maintenance Alaris Infusion System Description. Infusion system modules connect to an infusion controller (PCU). The PCU connects wirelessly to the VA enterprise network to transmit and receive data with the Alaris Systems Manager server. The Alaris Systems Manager resides on a server (virtual or physical) in a VA data center. Users will access the Alaris Systems Manager server to manage system configuration, retrieve pump connectivity data, capture data analytics, and upload infusion drug libraries. Users will also access software applications such as Guardrails Editor and Infusion Knowledge Portal (IKP) to manage drug library configuration and analyze reports collected from infusion data. The Alaris System Maintenance software is used during Alaris Infusion System maintenance. The Contractor shall provide the Alaris Support Program required under this contract for the following Alaris Infusion System equipment covered under this contract. All services performed shall support compatibility with the current infusion equipment. Table 2. Supported Alaris Equipment and Software Facility Name Server/Application Name Operating System/Version VISN 1 (VM hosted at BHS- Jamaica Plain campus) VHAV01CCAALARIS.V01.MED.VA.GOV Windows Server 2016 SCOPE OF WORK Under an Alaris Support Program agreement, the contractor will provide support to keep the software performing properly, including updates and upgrades as applicable. Software updates for BD servers to maintain the security or operation of the Software are generally released monthly. BD will deploy the updates to the BD server, and when the customer reboots the device, the update is installed. Software upgrades are included in a contracted support plan during the initial term and are scheduled at a mutually agreed-upon time. Upgrade means a major enhancement, new feature, or other improvements to the software. Hardware, 3rd party software, or any other software that BD generally licenses separately are not included. As upgrades are not provided automatically, BD will coordinate them directly with the customer.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C24126Q0790.docx
18 KBAdded in Special Notice version 1Posted
Lifecycle
- 1Version 1Special NoticeCurrent
J065--Intent to Sole Source Alaris Service and Maintenance
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Notice of Intent to sole source | 95% | Market Research | 11/06/2026 |
DynaCAD Maintenance and Support for RMR. Department of Veterans Affairs Eastern Colorado Health Care System, Located at 1700 N. Wheeling Street. Aurora, CO 80045. Due 11/12/2026 at 14:00pm MST. | 94% | Combined Synopsis | 11/12/2026 |
92% | Awarded | Open | |
NOTICE OF INTENT TO SOLE SOURCE: The Department of Veterans Affairs Network Contracting Office 6, 100 Emancipation Drive, Hampton, VA 23667, intends to award a sole source Firm-Fixed-Price purchase order to B. BRAUN MEDICAL INC., 824 12TH Ave, Bethlehem, Pennsylvania 18018-3524 for the Salem VAMC, 1970 Roanoke Blvd, Salem, NC 24153 for a Service Agreement Contract on Twenty-three (23) Hemodialysis Units manufactured by B. Braun Medical. This contract action is for products for which the Government intends to solicit from only one source under the authority of FAR 13.106-1(b), Soliciting from a Single Source. The North American Industry Classification System (NAICS) for this requirement is 811210 with a business size standard of $34.0 Million. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTATIONS. Responsible sources may identify their interest and capability to meet this requirement by submitting such information by 10:00 A.M., EST, on Monday, October 26, 2026. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Zanona Pickett, Contract Specialist, at zanona.pickett@va.gov. Telephone inquiries will not be accepted. | 87% | Special Notice | 10/26/2026 |
Indianapolis Stretcher Service Maintenance | 87% | Awarded | Open |
Additional Details
Solicitation Number
36C24126Q0790
Archive Date
Nov 3, 2026
Office Address
TOGUS, ME, 04330