Notice ID: 389b8a371bf44a203a0712728bcf6bf6Combined Synopsis/Solicitation
Q--Service Legionella Sampling & Testing at Hudson Valley Healthcare System
Archived on October 30, 2019. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 AM UTC−05:00
- Posted
- September 27, 2019
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541380: Testing Laboratories and Services
Notice details
- PSC
- Q: MEDICAL SERVICES
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24219Q1222
- Notice ID
- 389b8a371bf44a203a0712728bcf6bf6
Description
The purpose of this amendment is to provide question and answers from interested vendors. The solicitation due date is 30 September 2019 at 12:00 PM EST. Q: Will you accept Past Performance for legionella sampling, testing, and reporting from Private Industry? Yes. Please send the past performance questionnaire directly to andres.cepeda@va.gov and include vendor name and solicitation number 36C24219Q1222 in the subject of the email.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24219Q1222- Combined Synopsis
- 4×Combined SynopsisCurrentSep 19, 2019
Q--Service Legionella Sampling & Testing at Hudson Valley Healthcare System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The contractor shall provide all parts, labor, materials, supplies, equipment, transportation, and services necessary to collect drinking water samples on Hurlburt Field, transport them to the contract laboratory, and analyze such samples, including resampling. Services must conform to all, most current, applicable federal regulations and Florida Administrative Codes (F.A.C.). This work is required in accordance with (IAW) Safe Drinking Water Act; Rule 62-550, F.A.C.; Drinking Water Standards; Rule 62-560, F.A.C.; Requirements for Public Water System that are out of Compliance and Department of Defense Instruction 4715.6, and Environmental Compliance. All sampling technicians will follow all applicable Department of Environmental Protection (DEP) Standard Operating Procedures. Amendment 0001: upload Q&A and extend the proposal submission due date. Amendment 0002: Upload additional Q&A and the solicition provisions, clauses, and CLIN structure due to error in system deleting them. Upload an updated SOW. | 68% | Combined Synopsis | 10/02/2026 |
The Contractor shall furnish key personnel to provide services necessary to perform onsite Radiation Safety Officer (RSO) duties for the Eastern Oklahoma Veteran Affairs Health Care System (EOVAHCS). The RSO will oversee the daily operations for the facility, performing all duties associated with that role. The RSO position is a director-appointed position and answers directly to the Chief of Staff (COS) or designee. The RSO is responsible for all radiation-related issues that are associated with the Eastern Oklahoma Veteran Affairs Health Care System (EOVAHCS). The RSO will establish and implement radiation safety procedures commensurate with the use of fluoroscopy and reviewing them periodically to ensure their conformity with Federal Radiation Safety Regulations VHA directive 1105.02. Ensuring regulatory standards for radiation safety and medical physics practices are followed throughout the facility in accordance with: VHA-Directive-1105.02-Nuclear-Medicine-and-Radiation-Safety-Services.aspx D 1105 Management of Radioactive Materials for SharePoint_20251126.pdf VHA 1129 Directive.pdf and 10 CFR 35.2 (see RSO definition: experienced RSO) or 10 CFR 35.50 and 35.59 (for a new RSO) NUREG-1556, Vol. 9, Rev. 35 CFR § 731.106 https://www.ecfr.gov/current/title-5/chapter-I/subchapter-B/part-731/subpart-A/section-731.106. Place of Performance: Services shall be provided onsite at the following Eastern Oklahoma Veteran Affairs (VA) Health Care System (EOVAHCS) locations: Jack C Montgomery Veteran Affairs Medical Center, located at 1011 Honor Heights Dr., Muskogee, OK 74401 Ernest Childers Veteran Affairs Outpatient Clinic, located at 8921 S Mingo Rd Tulsa, OK, 74133 James Mountain Inhofe Veteran Affairs Medical Center, located at 440 S Houston Ave, Tulsa OK, 74127 | 68% | Solicitation | 11/03/2026 |
The US Army Corps of Engineers, New York District (NYD) intends to issue a solicitation package seeking to award one Indefinite Delivery Indefinite Quantity (IDIQ) contract for the Chemical Testing of Dredged Material. The IDIQ contract would include the sampling and testing of dredged material proposed for placement at the Historic Area Remediation Site (HARS). HARS sampling and testing would adhere to the procedures, and their subsequent updates, as described in: 2016 US Army Corps of Engineers New York District/EPA Region 2 Guidance for Performing Tests on Dredged Material Proposed for Ocean Disposal (a.k.a. Regional Testing Manual) (http://www.nan.usace.army.mil/Portals/37/docs/regulatory/Formdoc/FINAL_NYD-R2_REGIONAL_TESTINGMANUAL-APRIL%202016.pdf) 1991 EPA/USACE, Evaluation of Dredged Material Proposed for Ocean Disposal (a.k.a. the Green Book) (https://www.epa.gov/sites/production/files/2015-10/documents/green_book.pdf). The IDIQ contract would also include the sampling and testing of dredged material proposed for upland placement. “Upland” sampling and testing would adhere to the procedures, and their subsequent updates, as described in: New Jersey Department of Environmental Protection (NJDEP) New Jersey Administrative Code (NJAC), Title 7, Chapters 9 and 26 (a.k.a. ‘NJAC 7’) (https://dep.nj.gov/rules/current-rules-and-regulations/) New York State Department of Environmental Conservation (NYSDEC) manual, entitled “Technical & Operational Guidance Series (TOGS) 5.1.9 In-Water and Riparian Management of Sediment and Dredged Material” (November 2004) (a.k.a. ‘TOGS 5.1.9’) (https://www.dec.ny.gov/docs/water_pdf/togs519.pdf) New York State Department of Environmental Conservation, New York Codes, Rules and Regulations (NYCRR), Title 6, Part 375 (December 2025) (a.k.a. ‘6 NYCRR Part 375’) (https://dec.ny.gov/sites/default/files/2025-12/6nycrrpart375final.pdf). Other state procedures may also be requested and would be coordinated between NYD and the contractor to determine capabilities. Additional work under this contract will include analyses of sediment, tissue, and water and may include environmental DNA/metagenomic analyses related to HARS monitoring in accordance with the following document and any subsequent updates: U.S. Army Corps of Engineers (USACE) New York District and Environmental Protection Agency (EPA) Region 2, Site Management and Monitoring Plan for Historic Area Remediation Site (HARS) (July 2020). Task orders would include all or some of the following: sediment and water collection (on Contractor-supplied ship) handling, processing and shipping of samples physical and chemical analyses quality assurance (QA) and quality control (QC) procedures, and necessary corrective actions. For each task order, the contractor would provide reports containing the sampling logs, all testing results and QA/QC information in the format required by NYD, EPA – Region 2, and/or state agencies. In addition to sampling and testing for ocean placement, NYD also requires that contractors be capable of performing testing procedures such as the Synthetic Precipitation Leaching Procedure (SPLP), the Toxicity Characteristic Leaching Procedure (TCLP), and the Modified Elutriate Test (MET), which are required for upland placement of dredged material in the states of New York and New Jersey. Prior to sampling and testing, a Work/Quality Assurance (QA) Plan and an Accident Prevention Plan (APP) would need to be prepared by the contractor and approved by NYD. A Work/QA Plan must include: descriptions of all technical procedures for field sampling, laboratory analyses (e.g. biological, physical) for HARS and upland testing, data reduction and validation, and reporting clearly written standard operating procedures (SOP) for all field, experimental and analytical procedures clearly defined QA objectives that are consistent with the regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) and if applicable, permit application mechanisms for conducting performance and systems audits during the course of the field laboratory work procedures for detecting problems with sampling and analytical work, and implementation of corrective actions in a timely manner. All sampling would be performed within the Port of New York & New Jersey, all Federal Navigation Channels within New York District, the length of the Hudson River, in the Atlantic Ocean at the Historic Area Remediation Site and its Mud Dump Reference Site. “New Work or Harbor Deepening” projects may be proposed and coordinated between NYD and the contractor. A detailed description of work required for these contracts will be provided in its entirety upon issuance of the complete solicitation. Prior to issuance of the solicitation, it is highly recommended that interested parties read the required regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) in order to obtain a thorough understanding of the work required by the NYD and EPA – Region 2 dredged material testing program. The Period of Performance will be five (5) years from the issuance of the Notice to Proceed (NTP). The contract magnitude will be up to $10,000,000.00 for five (5) years – up to $2,000,000.00 each year. One contract will be awarded on an Unrestricted Full and Open Competition basis to the lowest bidder who has, within the last 18 months, demonstrated their capability of performing the program’s work to EPA – Region 2. A bidder can prove their capability through one of the following: the bidder has received, within the last 18 months from EPA – Region 2, documentation stating that the laboratory has submitted data that is fully acceptable or acceptable with qualification; or the bidder has satisfied the Demonstration of Capability (DOC) requirements for the NYD and EPA – Region 2 dredged material testing program. The North American Industry Classification System (NAICS) code is 541380. The business size standard is $25,500,000. | 66% | Pre-Solicitation | 11/23/2026 |
64% | Awarded | Open | |
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made. | 64% | Combined Synopsis | 11/12/2026 |
Additional Details
Solicitation Number
36C24219Q1222
Archive Date
Oct 30, 2019