Notice ID: 7e32de3dc33d424f8865245ec8df5e62Solicitation
J061--Albany Stratton VAMC Uninterrupted Power Supply (UPS) Maintenance
Archived on March 1, 2023. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:00 PM UTC−05:00
- Posted
- January 25, 2023
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 811210: Electronic and Precision Equipment Repair and Maintenance
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Place of performance
- See below description, Albany, 12208
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24223Q0197
- Notice ID
- 7e32de3dc33d424f8865245ec8df5e62
Description
See Attachment: Amendment 0001.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Contract end date
Feb 29, 2024
NAICS
811210
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24223Q0197- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 2×Pre-SolicitationJan 12, 2023
J061--Albany Stratton VAMC Uninterrupted Power Supply (UPS) Maintenance
- 4×SolicitationCurrentJan 18, 2023
J061--Albany Stratton VAMC Uninterrupted Power Supply (UPS) Maintenance
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Amendment 0006 to answer questions and provide update to CLIN and PWS | 90% | Solicitation | 10/30/2026 |
This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name (b) Address (c) Point of Contact (d) Phone, Fax, and Email (e) UEI number (f) Cage Code (g) Tax ID Number (h) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (i) Is your company considered small under the NAICS code identified under this SSN/RFI? (j) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (k) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (l) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (m) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work. (n) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (o) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (p) Please provide general pricing of your products/solution for market research purposes (q) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (r) Please provide general pricing of your products/solution for market research purposes (s) Must provide a capability statement that clearly addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirement: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide Annual Preventative Maintenance Inspections, Emergency Services and Repairs to Uninterrupted Power Supply Units, St. Louis John Cochran VA Medical Center, 915 North Grand Blvd., St. Louis, MO 63106 and Jefferson Barracks VA Medical Center, 1 Jefferson Barracks Dr., St. Louis, MO 631252401 West Main St, Marion, IL 62959. Please see the Performance Work Statement for more specific details. The North American Industry Classification System Code (NAICS Code) is 811210 (Electronic and Precision Equipment Repair and Maintenance), size standard $34. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open may be used. Responses to this notice shall be submitted via email to Lisa A Buchanan at lisa.buchanan1@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, September 18, 2026 at 3:00PM. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to these sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Performance Work Statement Preventative Maintenance, Service, and Repairs to Uninterrupted Power Supply Units and Batteries at the St. Louis VA Health Care System Section 1: General Information General: This is a non-personal services contract to provide maintenance, annual preventative maintenance inspections, emergency services, and repairs to uninterrupted power supply (UPS) units for the St. Louis VA Health Care System (STLVAHCS). The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government. Period of Performance: A. Period of performance shall be base year plus four option years. CLIN Base Year 0001: October 1, 2026, to September 30, 2027 CLIN Base Year 1001: October 1, 2027, to September 30, 2028 CLIN Base Year 2001: October 1, 2028, to September 30, 2029 CLIN Base Year 3001: October 1, 2029, to September 30, 2030 CLIN Base Year 4001: October 1, 2030, to September 30, 2031 Place of Performance: Services are required at the following locations. The points of contact (POC) for each location are listed. All work must be coordinated with the COR. John Cochran VAMC 915 N Grand Blvd. St. Louis, MO 63106 POC: Shane Pettis (314) 652-4100 x51032 Jefferson Barracks VAMC 1 Jefferson Barracks Dr. St. Louis, MO 63125 POC: Patrick Sanders (314) 652-4100 x66698 Hours of Operation: All repairs shall be performed during business hours from 8:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. Contractors may work outside normal business hours by arrangement with the COR if such services are provided without additional charge to the government. Observed Federal Holidays January 1 New Year s Day Third Monday in January Martin Luther King Jr. s Birthday Third Monday in February President s Day Last Monday in May Memorial Day June 19 Juneteenth July 4 Independence Day First Monday in September Labor Day Second Monday in October Columbus Day November 11 Veteran s Day Fourth Thursday in November Thanksgiving Day December Christmas Day Type of Contract: The government will award a Firm Fixed Price contract. Invoicing: All invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. VA s Electronic Invoice Presentment and Payment System The FSC uses a third-party contractor, Tungsten, to transition vendors from paper to electronic invoice submission. Please go to this website: http://www.tungsten-network.com/US/en/veterans-affairs/ to begin submitting electronic invoices, free of charge. More information on the VA Financial Services Center is available at http://www.fsc.va.gov/einvoice.asp. Vendor e-Invoice Set-Up Information: Please contact Tungsten at the phone number or email address listed below to begin submitting your electronic invoices to the VA Financial Services Center for payment processing, free of charge. If you have questions about the e-invoicing program or Tungsten, please contact the FSC at the phone number or email address listed below: Tungsten e-Invoice Setup Information: 1-877-489-6135 Tungsten e-Invoice email: VA.Registration@Tungsten-Network.com FSC e-Invoice Contact Information: 1-877-353-9791 FSC e-invoice email: vafsccshd@va.gov Payments: Government only paid for services rendered. Government will not pay on any uncompleted or undelivered work, services, or goods. Section 2: Definitions & Acronyms Definitions: Contractor. A supplier or vendor awarded a contract to provide specific supplies or service to the government. The term used in this contract refers to the prime. Subcontractor. One that enters a contract with a prime contractor. The Government does not have a contract with the subcontractor. Workday. The number of hours per day the Contractor provides services in accordance with the contract. Work Week. Monday through Friday, unless specified otherwise. Acronyms: COR Contracting Officer Representative NFPA National Fire Protection Association OEM Original Equipment Manufacturer OSHA Occupational Safety and Health Administration POC Point of Contact PM Preventative Maintenance PMI Preventative Maintenance Inspection UPS Uninterrupted Power Supply VA Veterans Affairs STLVAHCS St. Louis VA Health Care System Section 3: Government Furnished Property, Equipment, and Services A. This PWS does not have any government furnished equipment. Contractor shall not use any government owned equipment, material, supplies, or tools. Contractor shall furnish all requirements. The government reserves option to terminate the contract if contractor uses government equipment or supplies without written approval from the Contracting Officer and COR. Section 4: Contractor Furnished Items and Services The Contractor shall provide all equipment, supplies, management, supervision, personnel, and transportation necessary to assure that all services are in accordance with the contract and all applicable laws and regulations. The contractor shall ensure all work meets performance standards specified in this Performance Work Statement (PWS) and referenced documents to include all notes, explanatory material, and appendixes. The Contractor shall provide all equipment, supplies, management, supervision, personnel, transportation necessary, and consultation to assure that all services are in accordance with the contract and all applicable laws and regulations. The contractor shall ensure all work meets performance standards specified in this Performance Work Statement (PWS) and referenced documents. The Contractor shall provide one designated point of contact (POC) to the government s designated representative for coordination of parts delivery, scheduling, and / or maintenance. The contractor shall provide a toll-free telephone number for service calls, which must be answered 24 hours a day, 7 days a week. The contract shall have an inventory of parts and supplies in quantities sufficient to effectively service the resulting contract. The contractor should have an internal inventory system and delivery system for the parts and supplies. The inventory and delivery system must be sufficient to service the contract. Contractors Qualifications: Contractor shall have technical training, track records of working experience in Maintenance, Inspection, Testing of UPS and its components in healthcare, industrial, educational and commercial facilities for a minimum of five (5) continuous years. Contractor shall possess certificates on equipment for which work will be performed. Contractor shall have safety training either on-the-job or classroom type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical and NFPA 70E Standard for Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certifications are available, the contractor s employer shall certify that the service technician has met this requirement in writing and submit it to the VA Contracting Officer prior to work. Section 5: Specific Tasks Preventative Maintenance, Repairs and Testing The contractor shall guarantee a 3-hour response time, 24 hours, 7 days a week. Contract shall cover 100% of the labor, supplies, material, electrical components, electronic components, consultation, and travel at no additional cost to the government, excluding external batteries and filter. Contractor shall provide the following preventive maintenance service under this contractor: Inspection, repair, and service 24 hours and 7 days a week of the electronic portion of the UPS shall be performed as needed during the contracted period of maintenance at no additional cost to the government. Remedial maintenance and repairs provided by contractor shall include all parts and labor. All corrective maintenance to UPS and Batteries, if any, shall be in accordance with manufacturers recommendations, warranties, and separate agreement, if any. Contractor shall perform a one (1) time battery replacement (80 batteries), and capacitors, and fans during base year for the Eaton 9390 UPS, Serial# ED273CBB03 located in Bldg. 3 at John Cochran. Contractor shall perform maintenance of the following equipment: UPS Equipment Covered List John Cochran Building Location Make Model Serial Type/Size Bldg. 3 Eaton (80 Batteries) 9390 ED273CBB03 160kVA Bldg. 1 A201A Eaton 93PM-200-4 EU263UXX09 180kVA Bldg. 1 A001 APC (16 Batteries) SYCF40KF PD0736260060 40kVA Bldg. 1 C218 APC (16 Batteries) SYCF40KF PD1037160010 40kVA Bldg. 1 D502 APC 72-174001-00 C11945190003 50kVA Jefferson Barracks Building Location Make Model Serial Type/Size BLDG. 1, 4C02A FERRUPS (8 Batteries) FE12.5 KVA FE1P 3K02757 12.5 kVA BLDG. 1, GC11 EMERSON (48 Batteries) NRD91CCSA0A2294 M14J3F0003 90 kVA BLDG. 56, BB102 EATON 160 UPS1 EK211CBC01 160 kVA BLDG. 56, BB102 EATON 160 UPS1 EK206CBC10 160 kVA Contractor shall perform the following: Temperature checks on all breakers Connections Inspection of the equipment including subassemblies Wiring harnesses Contacts Rectifier and Inverter snubber boards for discoloration Power capacitors for swelling or leaking oil DC capacitor vent caps that have extruded more than 1/8 IN Record all voltages on module cabinet Record all current on module cabinet Record harmonic trap filter currents Check inverter and rectifier snubbers for burned or broken wires Check all nuts, bolts, screws, and connectors tor tightness (manufacture torque recommendation) and discolorations Check all fuses DC and AC Check fuses on the DE capacitor deck for continuity Perform operational test of the system transfer unit Perform battery discharge calibrate Record all electronic to system specifications install or perform engineering field charge notices Measure all low voltage power supply levels Measure and record phase to phase input voltage and current Review performance with COR Include all manufacture recommendations Battery maintenance and inspection service: Check integrity of battery cabinet NO-OX grease or oil on all connection Check battery jars for proper liquid levels Check for corrosion on all the terminals and cable Check physical cleanliness of battery room and jars Measure and record DC bus ripple voltage Measure and record total battery float discharge Measure and record individual cell/battery float voltages and overall float voltage Charger output current and voltage AC ripple current and voltage imposed on the battery Ambient temperature Negative terminal temperature of all batteries Include all manufacture recommendations Maintenance Frequency UPS and Batteries shall be inspected, tested, and maintained Semi-Annually and one annual preventative maintenance. If contractor misses or fails to conduct the inspection or maintenance within the Semi-Annual timeframe the contractor shall provide a report with reason why inspection or maintenance was missed. Contractor shall perform missed inspection immediately and submit inspection report within 2 weeks (14 days) after inspection has been completed. The government shall not pay for missing semi-annual or annual inspections. The government only pays for services rendered. Contractor shall submit dates for semi-annual and annual inspections within 10 days of award. Fiscal Year is from October 1 to September 30. Contractor will maintain a Log update with date, time, description of work, and technician. Log shall be near or with UPS. Log shall be submitted to COR and Compliance office by the year. Contractor shall provide training on basic use and troubleshooting of each UPS unit listed on the equipment list every six months. Contractor shall schedule training with the COR. Contractor shall maintain drawings, schematics, manuals, and any other appropriate documentation up to date and have copies at UPS. The contractor shall provide any drawing, schematics, manuals, and any other appropriate documentation at no additional cost to the government. Site Investigation and Conditions Affecting Work The Contractor acknowledges that it has taken steps reasonably necessary to ascertain the nature and location of the work, and that it has investigated and satisfied itself as to the general and local conditions which can affect the work or its cost, including but not limited to (1) conditions bearing upon transportation, disposal, handling, and storage of materials; (2) the availability of labor, water, electric power, and roads; (3) uncertainties of weather, river stages, tides, or similar physical conditions at the site; (4) the conformation and condition of the ground; and (5) the character of equipment and facilities needed preliminary to and during work performance. The Contractor also acknowledges that it has satisfied itself as to the character, quality, and quantity of surface and subsurface materials or obstacles to be encountered insofar as this information is reasonably ascertainable from an inspection of the, including all exploratory work done by the Government, as well as from the drawings and specifications made a part of this contract. Any failure of the Contractor to take the actions described and acknowledged in this paragraph will not relive the Contractor from responsibility for estimating properly the difficulty and cost of successfully performing the work, or for proceeding to successfully perform the work without additional expense to the Government. The Government assumes no responsibility for any conclusions or interpretations made by the Contractor based on the information made available by the Government. Nor does the Government assume responsibility for any understanding reached or representation made concerning conditions which can affect the work by any of its officers or agents before the execution of this contract, unless that understanding or representation is expressly stated in this contract. Contractor has the responsibility to make the determination and request a site walk. Failure to perform a site walk shall not relieve the contractor to complete the contract on time and within budget. Contract Modifications Throughout the performance of this contract UPS may need to be added or removed from the contract. In the event that the needs change, the Contractor will negotiate with the Contracting Officer to reach a mutually agreeable adjustment to the contract that must be captured in a written modification to the contract. Safety: No shorts or tank tops shall be permitted. Contractor shall adhere to OSHA 10 CFR 1910. Contractor shall be responsible to use appropriate PPE when required by the OSHA, NFPA 70E, and VAPAHCS. Safety plan shall be submit to the COR within 15 days of awarded contract. Performance Standards: Contractor shall adhere to the performance standards listed below. Contractor shall adhere to all references in the performance standard to include all notes, explanatory material, and appendixes. The most current edition will be used on all references listed below. NFPA 70E: Standard for Electrical Safety in the Workplace NFPA 99: Health Care Facilities Code OSHA Standard 29 CFR 1910 If a dispute between two codes arises, the most stringent code shall be enforced. If contractor has a different code interpretation than the COR then contractor shall have the opportunity to have the Engineering Compliance office review and make decision, which contractor shall accept. The AHJ shall be the Chief of Engineering of STLVAHCS. Documentation Requirements The Contractor shall provide reports to the COR. Each report shall include a separate document for each UPS. Submit four (1) hard copies of the completed written report and one CD Rom of the electronic version of the report in Microsoft (i.e. excel, word..) format to the Engineering Compliance Office within seven (7) calendar days of completion of inspection and testing. Security Requirements The Certification and Accreditation requirements do not apply and a Security Accreditation Package is not required for this work. Contractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, VA directives and handbooks as VA personnel regarding information security under VA Handbook 6500.6, Contract Security, Appendix C. Section 6: Attachments None | 90% | Market Research | 09/18/2026 |
Page 1 of This is a Sources Sought Notice (a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited. (b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only. (c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center 113 Holland Avenue, Syracuse, NY 12208 . The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million. The requirement is detailed in the Statement of Work section of this document. (e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103. - Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic. If contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. The following information is required for determining procurement strategy and viability of sources: Set aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work? If your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company? How many years experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity? How many jobs of this nature, of this scope and this complexity have you performed in the past five years? How many certified/licensed technicians does your company currently employ? - Contractors shall also identify any Federal Supply Schedules that may carry the desired services. - Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors. - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. - Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. - Contractors shall include any relevant comments about the Attachment(s) if applicable. Below is the Limitation on Subcontracting Certificate of Compliance Clause. Please complete this as part of your response. 852.219-75Â VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction. As prescribed in 819.7011(b), insert the following clause: VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) (a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.] (i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. (ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating 18 U.S.C. 1001. (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee:_________________________ Printed Title of Signee: ____________________________ Signature: ____________________________________________ Date: _______________________ Company Name and Address:____________________________________________ Statement of Work (Abridged) Overview The Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work. SCOPE OF WORK The contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems Period of Performance: The estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years. The Period of Performance reads as follows: Base Year 01/01/2027 12/31/2027 Option Year I 01/01/2028 12/31/2028 Option Year II 01/01/2029 12/31/2029 Option Year III 01/01/2030 12/31/2030 Option Year IV 01/01/2031 12/31/2031 Hours of Work: Facility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman. Reports: The contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR. Place of Performance: The work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208. PM Procedures: The contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements. Contractor shall perform medical air purity test. Contractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030 certified for inspection and testing. Minor repairs will be done while on station more difficult repairs or those needing additional parts will require a quote. There will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing. The system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided. Terminals: Terminal screws, front and back body O-rings, locking mechanism adjustment, lubrication, cleaning, flow/pressure measurement and locking mechanism verification. Valves: Rebuild leaking valves (ball type), cleaning and leaking inspection. Alarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration, cleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM Performance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed and verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA, JCAHO Standards. Medical Oxygen System: Annually Test area alarms for proper pressure switch location and alarm function. Test Oxygen system for concentration and gaseous purity at each outlet. Test Oxygen for particulate contamination at least once in each zone. Tested with 0.45 micron filter device. Test Oxygen system for pressure at each zone. Test each Oxygen outlet for proper function, identification, adaptation and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rates Test Oxygen zone shut-off valves for proper function, identification and mechanical integrity. Check Oxygen pipeline for proper identification labeling. Test each zone for available flow. Test operational pressure at each station outlet/inlet Test each critical care outlet operational pressure Test outlet flow rate and pressure drop with high demand at adjacent outlets. Test Oxygen system components for leakage. Check Oxygen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Medical Air System: Annually Test area alarms for proper pressure switch location and alarm function. Test Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.). Test at source sample valve. Test Medical Air for particulate contamination at least once in each zone. Tested with 0.45 micron filter device Test source for dew point. Test Medical Air System for pressure at each zone. Test each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rates Test Medical Air zone shut-off valves for proper function, identification, and mechanical integrity. Check Medical Air pipeline for proper identification labeling Test each zone for available flow. Test operational pressure tests at each station outlet/inlet Test each critical care outlet operational pressure test. Tested outlet flow rate and pressure drop with high demand at adjacent outlets Test Medical Air System components for leakage. Check Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Medical Surgical Vacuum System: Annually Test area alarms for proper pressure switch location and alarm function Test each Vacuum inlet for available flow rate SCFM Test operational pressure tests at each station outlet/inlet Tested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity. Identified leaking/malfunctioning inlets Identified inlets delivering substandard vacuum/flow rate Test all Vacuum zone valves for proper function, identification, and mechanical integrity Check Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Nitrogen System: Annually Test area alarms for proper pressure switch location and alarm function Tested Nitrogen system for particulate contamination. Tested with 0.45 micron filter device Test Nitrogen system for pressure at each zone. Test Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rate Test Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity. Check Nitrogen pipeline for proper identification labeling. Test Nitrogen control panels for leakage and proper operation. Check Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Check flexible connectors. Nitrous Oxide System: Annually Test area alarms for proper pressure switch location and alarm function Test Nitrous Oxide system for concentration Tested Nitrous Oxide system for particulate contamination. Tested with 0.45 micron filter device Test Nitrous Oxide system for pressure at each zone. Test each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity. Identified leaking/malfunctioning outlets Identified outlets delivering substandard pressure/flow rates Test Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity. Check Nitrous Oxide pipeline for proper identification labeling. Test each Nitrous Oxide outlet for available flow. Test Nitrous Oxide pipeline components for leakage. Check Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.) Check for crossed lines. Check flexible connectors. Dental Air System: Annually Test Dental Air system for pressure Test Dental Air zone shut-off valves for proper function, identification, and mechanical integrity. Check Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines Evacuation/WAGD: Semi-Annually Test area alarms for proper pressure switch location and alarm function Test inches (of mercury) of E-VAC at each zone Test each E-VAC inlet for available flow rate SCFM. Tested pressure at each inlet in all critical care areas. Tested for flow rate and pressure drop with high volume demand on adjacent inlets Test each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning inlets Identify inlets delivering substandard vacuum/flow rate Test all E-VAC zone valves for proper function, identification, and mechanical integrity Check E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Dental Vacuum System: Annually Check Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Medical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually Examining items and to ensure that they maintain normal operating conditions Examining the seal fluid quality, quantity, temperature, and rate of rise against design specifications Examining the pump bearing and mechanical seals Inspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults Greasing of the air and vacuum pump systems in accordance with manufacturer's specifications Inspection of demisters Cleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity. Replacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new. Check and replace belts if needed and equipped Repair Procedures: Emergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week. After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested. Urgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility. A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning. System shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area. The contractor shall be available 24 hours a day, seven days a week. The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status. The contractor is not required to be at the job site during the period the system is shutdown. The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system. Standby requires the Contractor to be at the job site during specified periods, as directed by the COR. Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system. The Contractor will be compensated for the entire standby period. | 84% | Market Research | 11/12/2026 |
This is not a Request for Quote. This posting is to comply with agency's requirement to post all GSA requirements to SAM.gov Uninterruptale Power System (UPS) Southpark G, Austin TX The requiring activity is the Office of Facility Management & Security Services (FMSS), The solicitation RFQ1785097 was posted on October 03, 2025, and will be distributed solely through the General Services Administration’s (GSA) IDIQ Building Maintenace and Operations (OANDMS2) All future information about this acquisition, including solicitation amendments, will also be distributed solely through https://www.ebuy.gsa.gov. Interested parties are responsible for monitoring that site to ensure that they have the most up-to-date information about this acquisition. The estimated closing date of the RFQ will be October 17, 2025. All responsible sources that are schedule holders under OANDMS2 may submit a quote on GSA eBuy website to be considered by this agency. No telephone requests, written requests, or questions about this solicitation will be accepted outside of GSA eBuy website. | 80% | Special Notice | 10/15/2025 |
Solicitation Number: 36C24627Q0092 Notice Type: Pre-Solicitation The Department of Veterans Network Contracting Office (NCO 06), Hampton, VA on behalf of the Durham VA Health Care System (VAHCS), intends to solicit a Small Business set-aside for Preventative Maintenance services for centrifuges and other included instruments for the Durham VA Medical Center Geriatric Research, Education, and Clinical Center (GRECC) located at 508 Fulton Street, Durham, NC 27705-3875. This pre-solicitation announcement publicizes the Department of Veterans Affairs intent to solicit for preventative maintenance services for centrifuges and other included equipment. A Firm-Fixed price contract is anticipated to be awarded. The VA anticipates issuing a Small Business set-aside solicitation for this requirement. The solicitation and any amendments will be available on System for Awards Management (SAM)website in Contract Opportunities at http://www.SAM.gov. Potential quoters will be responsible for downloading copies of the solicitation (and any subsequent amendments) from that website, and no hard copies will be made available. The solicitation will provide instructions to offerors about the quote submission process. Prospective Quoters are encouraged to register their interest in the solicitation on the SAM.gov website so that they are notified of the issuance of the solicitation and any amendments. Quotes will be evaluated for award after the solicitation has closed. In accordance with FAR 52.204-7, System for Award Management, prospective quoters must be registered in the System for Award Management (SAM) database under the applicable NAICS Code. Firms may obtain SAM information at https://www.sam.gov. To be eligible for award, contractors must be registered in SAM. Registration is free and potential quoters are encouraged to visit the SAM website and register as soon as possible. Questions concerning this announcement should be directed to the Contract Specialist using the e-mail link provided. No hard copies of the solicitation will be provided. Telephone requests for information or questions will NOT be accepted. Please email questions to Monique Cordero at Monique.Cordero@va.gov and ensure that the subject line includes Solicitation No. 36C24627Q00921 and reference your Company Name. Contracting Office Address: Department of Veterans Affairs Network Contracting Office (NCO6) Bldg. 27 Averill Drive, Hampton, VA 23667 | 73% | Pre-Solicitation | 11/12/2026 |
Additional Details
Solicitation Number
36C24223Q0197
Archive Date
Mar 1, 2023
Office Address
ALBANY, NY, 12208