Z1DA--RFQ - ALBANY 3RD PARTY WITNESS ANNUAL ELEVATOR SAFETY TESTS
Archived on April 30, 2023. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM UTC−04:00
- Posted
- March 28, 2023
- Notice type
- Solicitation
- NAICS
- 541350: Building Inspection Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Place of performance
- Stratton VAMC Albany NY 113 Holland Ave, Albany, 12208
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24223Q0401
- Notice ID
- 707cf2539adc4f00abfe9d1970a0393a
Description
During the 5 Year testing, will the hydraulic elevators be required to have the rupture valve test performed? This test varies based on locations. Some VA locations require this test to be performed while other VA locations do not. RESPONSE: Yes, the rupture valve test is required during the 5 year full load test. In the Statement of Work (H) it states that the VA elevator maintenance contractor will operate the elevators during the annual inspection. Will they also operate the elevators, physically perform inspections, and provide the test weights for the Category 5 inspections? RESPONSE: Yes. the maintenance contractor operates the elevators, physically performs inspections, and provides the test weights for the Category 5 inspections.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Contract end date
Jun 28, 2024
NAICS
541350
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24223Q0401- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Pre-SolicitationFeb 28, 2023
Z1DA--RFQ - ALBANY 3RD PARTY WITNESS ANNUAL ELEVATOR SAFETY TESTS
- 6×SolicitationCurrentMar 3, 2023
Z1DA--RFQ - ALBANY 3RD PARTY WITNESS ANNUAL ELEVATOR SAFETY TESTS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Elevator Inspections Base 4 Canandaigua VA Medical Center VAMC Bath VA Medical Center VAMC | - | Combined Synopsis | 11/13/2026 |
The purpose of this amendment is to notify all offerors/bidders that this solicitation resulted in no award. The VA may resolicit at a later date. WNY Chute, Barrier, & Door Inspections | - | Combined Synopsis | 11/12/2026 |
Elevator Inspection Services at James J. Peters VA Medical Center | - | Market Research | 10/23/2026 |
Elevator Third-Party Inspection and Testing Services BK & SA | - | Combined Synopsis | 10/16/2026 |
This is a "REQUEST FOR INFORMATION" only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of qualified sources to perform a potential requirement. This notice does not constitute a commitment by the Government, and no contract will be awarded from this notice. Responses to this Sources Sought notice must be in writing. The Department of Veterans Affairs is seeking qualified Architect-Engineer (A/E) firms to provide complete design and cost estimation services to upgrade the existing obsolete Edwards EST-3 fire alarm system (Project No. 528A7-24-112) at the Syracuse VA Medical Center located at 800 Irving Avenue, Syracuse, NY 13210. Work includes upgrading the existing fire alarm control panels and remote annunciators, installing a new fiber loop network connecting all panels and a new master control panel, expanding the addressable system to additional campus buildings, removing the existing fireman telephone system, and developing a phasing plan that maintains continuous fire alarm protection throughout construction. The A/E shall prepare complete working drawings, specifications, and detailed cost estimates, and provide construction period services. All drawings must be stamped by a registered Fire Protection Engineer (FPE), and the prime firm must have an FPE on staff no exceptions. Design shall comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. The NAICS Code is 541330 Engineering Services", with a size standard of $25.5M. All responsible sources may submit a capability statement which shall be considered by the Syracuse VA Medical Center. Please send all inquiries to: Ryan.Seburn@va.gov by 10:00 EST November 3rd, 2026. Phone calls will not be accepted. | - | Market Research | 11/03/2026 |
Additional Details
Solicitation Number
36C24223Q0401
Archive Date
Apr 30, 2023
Office Address
ALBANY, NY, 12208