GovChime
Notice ID: d4930d3d70f8425baf09156a0c4aa9dfSolicitation

H166--FY23 SERVICES - BASE + 4OY - MULTI-SITE UPS 797 Environmental And Personnel Sampling Supplies, Testing and Reporting. Syracuse VAMC, Finger Lakes VA, Western NY VA

Archived on October 19, 2023. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM UTC−04:00
Posted
July 18, 2023
Notice type
Solicitation
NAICS
541380: Testing Laboratories and Services
Agency
Department of Veterans Affairs

Notice details

Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Place of performance
800 Irving Ave, Syracuse, NY 13210 400 Fort Hill Ave, Canandaigua, NY 14424 3495 Bailey Ave, Buffalo, NY 14215, 13210
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C24223Q0929
Notice ID
d4930d3d70f8425baf09156a0c4aa9df

Description

This solicitation 36C24223Q0929 is established to fulfill a requirement for Environmental and Personnel Testing Supplies, Testing, and Reporting for the following VA facilities: The Syracuse VAMC, VA Healthcare System of the Finger Lakes (Canandaigua and Bath VAMCs), and The Western NY VA Healthcare System (Buffalo and Batavia VAMCs). This requirement is 100% set-aside for Small Business Entities. The Government intends to award a firm-fixed-price IDIQ contract via which the aforementioned VA facilities can place task orders against for testing supplies, testing, and reporting of results. Please refer to the detailed Statement of Work and Evaluation Factors within the attached solicitation. Pricing shall be submitted by completing the attached pricing spreadsheet. Evaluation of price will be based on the estimated quantities entered on the spreadsheet.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24223Q0929
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. Pre-SolicitationJul 13, 2023

    H166--FY23 SERVICES - BASE + 4OY - MULTI-SITE UPS 797 Environmental And Personnel Sampling Supplies, Testing and Reporting. Syracuse VAMC, Finger Lakes VA, Western NY VA

    Notice 5f71346f87344d3c83e1b4b776c2245b on SAM.gov

  2. SolicitationCurrentJul 18, 2023

    H166--FY23 SERVICES - BASE + 4OY - MULTI-SITE UPS 797 Environmental And Personnel Sampling Supplies, Testing and Reporting. Syracuse VAMC, Finger Lakes VA, Western NY VA

    Notice d4930d3d70f8425baf09156a0c4aa9df on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
The Veterans Health Administration, Network Contracting Office 02 intends to solicit from a single source IAW FAR 13.106(b) to obtain a contract for: Calibration Services to Include Maintenance and Repair Services for the Albany VA s currently owned radiation dosimetry calibrators. This equipment is utilized by the Nuclear Medicine department and is used in oncology procedures. Daily QA 3 software provides a graphical presentation of radiation oncology beam measurement data. This technology measures the output, flatness, symmetry, field size, and energy of rotational and Flattening Filter-Free (FFF) beams. This technology allows users to choose which data parameters to view and over what period to view them. A single measurement instance may be examined by clicking on a data point which corresponds to a particular day. This is completed prior to the treatment of patients and requires regular and recurring calibrations to ensure proper operation and safety to the patients receiving treatment. It is currently actively in use at the VA Medical Center (Albany) located at: 113 Holland Ave, Albany, NY 12208. Period of Performance (POP) (estimated): 10/1/2026 through 09/30/2027 with provision of (4) option years. All work to be completed NLT 30 days of receiving an awarded contract. Requirement Description: Sun Nuclear is the Original Equipment Manufacturer (OEM) of the equipment and systems currently in use at the Albany VA Medical Center. These proprietary systems are designed and manufactured exclusively for oncology applications within healthcare facilities. The equipment is regulated medical equipment and that must remain fully operational to support direct patient care activities. This includes Service and maintenance and calibrations of the equipment. These systems are essential for patient safety and effectiveness of therapy. Given the critical nature of this equipment, routine preventative maintenance, inspection, calibration, and repairs are required to prevent downtime and ensure continuous, safe operation. Sun Nuclear manufactures, distributes, and services its Equipment in compliance with applicable regulatory and quality standards. Market research and direct communication with the OEM confirm that Sun Nuclear does not authorize or utilize third-party service providers to perform maintenance or repair work on its proprietary equipment and systems due to maintaining warranty coverage of the equipment. The equipment in question is manufactured, sold, and serviced exclusively by Sun Nuclear Med. The use of non-factory-trained or unauthorized service providers would void the manufacturer s warranty and may compromise equipment integrity, regulatory compliance, and patient safety. Sun Nuclear employs factory-trained and certified service technicians who are specifically trained on their proprietary systems. These technicians possess exclusive access to OEM parts, technical documentation, software updates, calibration tools, and engineering support necessary to properly maintain and repair the equipment. Only these authorized representatives are qualified to perform required maintenance while preserving the binding manufacturer warranty. Given: The proprietary nature of the equipment The OEM s exclusive servicing structure The requirement to preserve manufacturer warranties The regulatory compliance obligations The critical role of the equipment to patient care and safety The Contracting Officer (CO) has determined that no other vendor can meet the agency s needs without unacceptable risk. Therefore, the most suitable and responsible course of action is to sole source this requirement to Sun Nuclear, the OEM and manufacturer, to ensure continued warranty protection, regulatory compliance, operational reliability, and the highest standard of patient health and safety. Place of Performance: Department of Veterans Affairs Albany VAMC 113 Holand Ave. Albany, NY 12208 The NAICS code for this requirement is: 541380 Testing Laboratories and Services (Size Standard: $19.0 Million). Intended Source: Sun Nuclear THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement by : Wednesday September 30th 2026 at 17:00 Eastern Standard Time (EST). The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses from responsible sources will be considered. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award. Interested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE RADIATION DOSIMETRY CALIBRATORS in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Contract Specialist, Jason M. Rundle at jason.rundle@va.gov. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements. Page 1 of Page 2 of 2 Page 1 of
-Special Notice09/30/2026
The US Army Corps of Engineers, New York District (NYD) intends to issue a solicitation package seeking to award one Indefinite Delivery Indefinite Quantity (IDIQ) contract for the Chemical Testing of Dredged Material. The IDIQ contract would include the sampling and testing of dredged material proposed for placement at the Historic Area Remediation Site (HARS). HARS sampling and testing would adhere to the procedures, and their subsequent updates, as described in: 2016 US Army Corps of Engineers New York District/EPA Region 2 Guidance for Performing Tests on Dredged Material Proposed for Ocean Disposal (a.k.a. Regional Testing Manual) (http://www.nan.usace.army.mil/Portals/37/docs/regulatory/Formdoc/FINAL_NYD-R2_REGIONAL_TESTINGMANUAL-APRIL%202016.pdf) 1991 EPA/USACE, Evaluation of Dredged Material Proposed for Ocean Disposal (a.k.a. the Green Book) (https://www.epa.gov/sites/production/files/2015-10/documents/green_book.pdf). The IDIQ contract would also include the sampling and testing of dredged material proposed for upland placement. “Upland” sampling and testing would adhere to the procedures, and their subsequent updates, as described in: New Jersey Department of Environmental Protection (NJDEP) New Jersey Administrative Code (NJAC), Title 7, Chapters 9 and 26 (a.k.a. ‘NJAC 7’) (https://dep.nj.gov/rules/current-rules-and-regulations/) New York State Department of Environmental Conservation (NYSDEC) manual, entitled “Technical & Operational Guidance Series (TOGS) 5.1.9 In-Water and Riparian Management of Sediment and Dredged Material” (November 2004) (a.k.a. ‘TOGS 5.1.9’) (https://www.dec.ny.gov/docs/water_pdf/togs519.pdf) New York State Department of Environmental Conservation, New York Codes, Rules and Regulations (NYCRR), Title 6, Part 375 (December 2025) (a.k.a. ‘6 NYCRR Part 375’) (https://dec.ny.gov/sites/default/files/2025-12/6nycrrpart375final.pdf). Other state procedures may also be requested and would be coordinated between NYD and the contractor to determine capabilities. Additional work under this contract will include analyses of sediment, tissue, and water and may include environmental DNA/metagenomic analyses related to HARS monitoring in accordance with the following document and any subsequent updates: U.S. Army Corps of Engineers (USACE) New York District and Environmental Protection Agency (EPA) Region 2, Site Management and Monitoring Plan for Historic Area Remediation Site (HARS) (July 2020). Task orders would include all or some of the following: sediment and water collection (on Contractor-supplied ship) handling, processing and shipping of samples physical and chemical analyses quality assurance (QA) and quality control (QC) procedures, and necessary corrective actions. For each task order, the contractor would provide reports containing the sampling logs, all testing results and QA/QC information in the format required by NYD, EPA – Region 2, and/or state agencies. In addition to sampling and testing for ocean placement, NYD also requires that contractors be capable of performing testing procedures such as the Synthetic Precipitation Leaching Procedure (SPLP), the Toxicity Characteristic Leaching Procedure (TCLP), and the Modified Elutriate Test (MET), which are required for upland placement of dredged material in the states of New York and New Jersey. Prior to sampling and testing, a Work/Quality Assurance (QA) Plan and an Accident Prevention Plan (APP) would need to be prepared by the contractor and approved by NYD. A Work/QA Plan must include: descriptions of all technical procedures for field sampling, laboratory analyses (e.g. biological, physical) for HARS and upland testing, data reduction and validation, and reporting clearly written standard operating procedures (SOP) for all field, experimental and analytical procedures clearly defined QA objectives that are consistent with the regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) and if applicable, permit application mechanisms for conducting performance and systems audits during the course of the field laboratory work procedures for detecting problems with sampling and analytical work, and implementation of corrective actions in a timely manner. All sampling would be performed within the Port of New York & New Jersey, all Federal Navigation Channels within New York District, the length of the Hudson River, in the Atlantic Ocean at the Historic Area Remediation Site and its Mud Dump Reference Site. “New Work or Harbor Deepening” projects may be proposed and coordinated between NYD and the contractor. A detailed description of work required for these contracts will be provided in its entirety upon issuance of the complete solicitation. Prior to issuance of the solicitation, it is highly recommended that interested parties read the required regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) in order to obtain a thorough understanding of the work required by the NYD and EPA – Region 2 dredged material testing program. The Period of Performance will be five (5) years from the issuance of the Notice to Proceed (NTP). The contract magnitude will be up to $10,000,000.00 for five (5) years – up to $2,000,000.00 each year. One contract will be awarded on an Unrestricted Full and Open Competition basis to the lowest bidder who has, within the last 18 months, demonstrated their capability of performing the program’s work to EPA – Region 2. A bidder can prove their capability through one of the following: the bidder has received, within the last 18 months from EPA – Region 2, documentation stating that the laboratory has submitted data that is fully acceptable or acceptable with qualification; or the bidder has satisfied the Demonstration of Capability (DOC) requirements for the NYD and EPA – Region 2 dredged material testing program. The North American Industry Classification System (NAICS) code is 541380. The business size standard is $25,500,000.
-Pre-Solicitation11/23/2026
Elevator Inspections Base 4 Canandaigua VA Medical Center VAMC Bath VA Medical Center VAMC
-Combined Synopsis11/13/2026
The purpose of this amendment is to notify all offerors/bidders that this solicitation resulted in no award. The VA may resolicit at a later date. WNY Chute, Barrier, & Door Inspections
-Combined Synopsis11/12/2026
This is a "REQUEST FOR INFORMATION" only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of qualified sources to perform a potential requirement. This notice does not constitute a commitment by the Government, and no contract will be awarded from this notice. Responses to this Sources Sought notice must be in writing. The Department of Veterans Affairs is seeking qualified Architect-Engineer (A/E) firms to provide complete design and cost estimation services to upgrade the existing obsolete Edwards EST-3 fire alarm system (Project No. 528A7-24-112) at the Syracuse VA Medical Center located at 800 Irving Avenue, Syracuse, NY 13210. Work includes upgrading the existing fire alarm control panels and remote annunciators, installing a new fiber loop network connecting all panels and a new master control panel, expanding the addressable system to additional campus buildings, removing the existing fireman telephone system, and developing a phasing plan that maintains continuous fire alarm protection throughout construction. The A/E shall prepare complete working drawings, specifications, and detailed cost estimates, and provide construction period services. All drawings must be stamped by a registered Fire Protection Engineer (FPE), and the prime firm must have an FPE on staff no exceptions. Design shall comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. The NAICS Code is 541330 Engineering Services", with a size standard of $25.5M. All responsible sources may submit a capability statement which shall be considered by the Syracuse VA Medical Center. Please send all inquiries to: Ryan.Seburn@va.gov by 10:00 EST November 3rd, 2026. Phone calls will not be accepted.
-Market Research11/03/2026

Additional Details

Solicitation Number

36C24223Q0929

Archive Date

Oct 19, 2023

Office Address

ALBANY, NY, 12208