Notice ID: a41197163765401490a21b0b29a2b017Combined Synopsis/Solicitation

6120--RFQ - Brand Name or Equal to ELECTRICAL TRANSFORMER

Archived on March 16, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM UTC−05:00
Posted
January 7, 2025
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)

Notice details

Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Place of performance
St. Albans VA Medical Center 179-00 Linden Boulevard, Queens, NY, 11424
Last updated
Jan 23, 2026

Identifiers

Solicitation number
36C24225Q0217
Notice ID
a41197163765401490a21b0b29a2b017

Description

To facilitate its mission, the New York Harbor Healthcare System Engineering Office requires the purchase of an electrical transformer for building 89 at the St. Albans VA Medical Center. After a power failure, the St. Albans VA Medical Center has been renting a Daelim Belefic 500kVA 4160 / 207Y / 120v three-phase radial feed pad-mount transformer until a transformer can be procured.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Feb 19, 2025

NAICS

335311

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Documents

Select documents to download

Showing 4 of 4 items

Document
Source
Agency
Posted Date
File Size
Actions
Sources SoughtVETERANS AFFAIRS, DEPARTMENT OFJan 7, 2025-
Combined Synopsis/SolicitationVETERANS AFFAIRS, DEPARTMENT OFJan 7, 2025-
Combined Synopsis/SolicitationVETERANS AFFAIRS, DEPARTMENT OFJan 7, 2025-
Combined Synopsis/SolicitationVETERANS AFFAIRS, DEPARTMENT OFJan 7, 2025-

Lifecycle

Solicitation:36C24225Q0217
  1. Market Research
  2. Combined Synopsis
  1. Market ResearchDec 26, 2024

    6120--Sources Sought - ELECTRICAL TRANSFORMER

    Notice f5c7e39fdc994c35ab0ee58bc8b8f2e7 on SAM.gov

  2. Combined SynopsisCurrentJan 7, 2025

    6120--RFQ - Brand Name or Equal to ELECTRICAL TRANSFORMER

    Notice a41197163765401490a21b0b29a2b017 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
1000 KVA TRANSFORMER
75%
Combined Synopsis09/30/2026
73%
AwardedOpen
Pad Mount Transformer
73%
Combined Synopsis08/31/2026
Provide one Pad Mounted Transformer 750 kVA, 13.2 kV /208Y/120 V. Salient Characteristics: Furnish one (1) pad mounted, dead front, radial transformer, rated: ? Capacity: 750 kVA ? Phases: 3 ? Primary Voltage: 13,200 V (15 kV class) ?Secondary Voltage: 208Y/120 V ? Frequency: 60 Hz ? Phase: Three phase ? Cooling :ONAN ? Fluid: Mineral oil 2. Mandatory Physical Dimensions: The following dimensions are non negotiable: ? Height: 63? inches (up to 64? inches) ? Width: 65 inches ? Depth: May varies (existing is 41 inches) The Contractor shall confirm with proposal the manufacturing dimensions, either in writing or by a shop drawing, for government approval. 3. Mechanical and Construction Requirements: The transformer shall include: ?Stainless steel tank, cabinet and hardware (304) ? Dead front construction ? Pentahead security hardware ? ANSI 61 Grey color to match with existing enclosure ? Welded tank construction, sealed and pressure tested ? 1-inch Oil drain valve located on the primary side with 3/8-inch water sampler (required due to secondary side cable congestion) ? Arc-flash and safety labeling ? Lifting lugs and jacking pads ? Nameplate per ANSI C57.12.00 4.Electrical Requirements: ? Primary bushings: (6) 200 A load break wells with inserts for (3)LV and (3) 10KV arresters ? Secondary bushings: NEMA spade w/ supports terminals 10holes (3) LV and (1) neutral per ANSI ? Configuration: Radial Feed ? Impedance: Standard ANSI values for 750 kVA ? Taps: 2 x 2.5% (standard 5 position no load tap changer) 5.Protection and Monitoring: The transformer shall include: ? Bayonet fuse with isolation link? Current limiting fuses ? Load break switch (2 position minimum) ? Nitrogen pressure gauge, test port and blanket ? Temperature gauge ? Pressure vacuum gauge ? Liquid level indicator ? Schrader valve Note: All gauges must be visible. 6. Compliance Requirements: The transformer must comply with: ? ANSI/IEEE C57.12 series ? DOE 2016 efficiency standards ? National Electrical Safety Code (NESC) ? National Electrical Code (NEC /NFPA 70) ? UFGS 26 12 19 ? Pad Mounted, Liquid Filled, Medium Voltage Transformers ?American Buy Act ? PCB-free oil certification ? UL Listed 002. Provide Factory routine test Reports Results and documentation as minimum: ? Insulation resistance test ? Winding resistance test ? Turns ratio (TTR) ?Polarity and phase-relation test ? No-load and load-loss test ? Dielectric test ? Excitation test ?Impedance test ? Applied and Induced potential tests ? Leak Test ? Oil quality test (dielectric strength, moisture, interfacial tension) ? Certified As-built drawings ? Certified test report signed by manufacturer ? Installation and OM manuals ? Warranty documentation (minimum 1 year) ? Destination to the federal facility Fort Buchanan, Puerto Rico00934 ? ECD: 40 weeks ? Unit must arrive fully assembled and ready for installation ?Packing slip must include contract number, PO number, and serial number? Minimum 1 year manufacturer warranty covering defects in equipment.
73%
Combined Synopsis07/29/2026
Pad Mount Transformer
73%
Combined Synopsis03/30/2026

Additional Details

Solicitation Number

36C24225Q0217

Archive Date

Mar 16, 2025

Office Address

ALBANY, NY, 12208