GovChime
Notice ID: 6174ecf59d1c43a285278e2a7345391fSources SoughtArchived

J023--Bronx (James Peters) VA Medical Center Long block engine repair on Spinal Cord Bus

Archived on July 23, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
June 18, 2026
Notice type
Sources Sought
NAICS
811114: Specialized Automotive Repair
Agency
Department of Veterans Affairs

Notice details

Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Place of performance
James Peters VA Medical Center, Bronx, New York, 10468
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24226Q0723
Notice ID
6174ecf59d1c43a285278e2a7345391f

Description

This is a "REQUEST FOR INFORMATION" only. This Sources Sought Notice is not a request for formal proposals or quotes. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HUBZone and other Small Businesses interested and capable of providing the services described below. Documentation on technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. This Sources Sought is for the James Peters VA Medical Center located at 130 West Kingsbridge Road, Bronx, NY 10468, who has a requirement for long block engine repair on a Spinal Cord Bus for one (1) month from award date. All parts, labor, fees, and materials shall be included in the purchase order to perform: Internal component replacement/refresh: Crankshaft, pistons, rings, bearings, camshaft, and valvetrain parts are reground, replaced, or reconditioned. Valve job: Pressure testing, resurfacing, and new stem seals for optimal airflow Precision machining: Block deck honing, cylinder boring/honing, main bearing bore alignment, and valve seat machining. Seals and gaskets: New cam bearings, freezing plugs, and gasket sets. Complete assembly: Engine is assembled with new or remanufactured parts, then tested for oil pressure, vacuum, and compression. Responses to this notice shall include the following: Company name, address, point of contact (phone and email), SAM UEI number Type of business (e.g. SDVOSB, VOSB, HubZone, 8(a), WOSB, Small Disadvantaged Business, or other Small Business) Brief capability statement addressing the Company s qualifications and ability to perform according to description above Subcontracting plans (note the limitations on contracting at 50% for services, FAR 52.219-4, Limitations on Subcontracting, and/or VAAR 852.219-75/852.219-76) Contractor shall be registered in SAM.gov. The NAICS Code is 811114 with a Small Business size standard of $9 million. SDVOSB/VOSB vendors shall be registered in the SBA Database. Any offeror capable of providing this service shall notify the Contract Specialist no later than June 23rd, 2026, 12:00 pm EST. All information is to be submitted via e-mail to: nathan.northrup@va.gov. Phone calls will not be accepted.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Dec 2, 2026

NAICS

811114

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Nathan Northrup
Contract Specialist

Documents

Files (1)

  • 36C24226Q0723.pdf

    160 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    J023--Bronx (James Peters) VA Medical Center Long block engine repair on Spinal Cord Bus

    Notice 6174ecf59d1c43a285278e2a7345391f on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Brand Name - LIFT POINT Lift Model ? LTX-22QTY - 1 Each22000 lb. Capacity Material Handling Service Lift - This lift is designed to lift material handling equipment (Forklifts) up in the air for maintenance personnel access/repair.No installation or Training Required in quote. Vendor must provide detailed specification list with bid.
-Combined Synopsis11/28/2025
Vehicle Repair and Preventive Maintenance Services This Request for Information (RFI) and Sources Sought Notice is issued solely for market-research and acquisition-planning purposes. It does not constitute a solicitation, request for quotation, or request for proposal. 1. Purpose The purpose of this notice is to assist the Government in making appropriate acquisition decisions and identifying qualified businesses capable of performing the required services. The Government is particularly interested in determining the availability and capability of small businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses. Domestic sources, or suitable domestic alternatives, are being sought for this requirement. The suggested North American Industry Classification System code is: NAICS 811111, General Automotive Repair Interested businesses may recommend a different NAICS code if they believe another code more accurately represents the principal purpose of this requirement. 2. Requirement The contractor shall provide all management, supervision, labor, transportation, tools, materials, replacement parts, fluids, equipment, and other resources necessary to repair and service the following vehicle: Vehicle: 2012 Chevrolet Express 3500 VIN: 1GBZG1FG3C1187198 Mileage: Approximately 67,539 miles The anticipated work includes, but is not limited to: Replacement of the transmission Required transmission programming, testing, and verification Tie-rod replacement Wheel alignment Brake-fluid service Full-synthetic engine-oil and filter service Throttle-body service Road testing Repair and service documentation Warranty information The complete technical requirements are provided in the attached draft Statement of Work, 586-SOW-Vehicle Repair and Preventative Services. 3. Place of Performance Services are required in support of the G. V. Sonny Montgomery VA Healthcare System, located at: 1500 E. Woodrow Wilson Avenue Jackson, MS 39216-5116 4. Response Instructions Interested and capable contractors are encouraged to respond no later than: Wednesday, November 18, 2026, at 2:00 p.m. Central Time Responses must be submitted by email only to: gary.frank@va.gov Each response should include the following: Company name Company address Primary point of contact Telephone number, fax number if applicable, and email address Unique Entity ID registered in SAM.gov Applicable socioeconomic business category, including: Service-Disabled Veteran-Owned Small Business Veteran-Owned Small Business 8(a) participant HUBZone small business Woman-Owned Small Business Small Disadvantaged Business Other small business category A statement indicating whether the company is considered small under the size standard associated with the identified NAICS code A brief capability statement describing the company’s relevant experience and ability to satisfy the requirement The company’s anticipated lead time for obtaining parts and completing the required services Proposed warranty coverage for parts and labor Any recommended alternative NAICS code and the reason for the recommendation 5. Disclaimer This RFI and Sources Sought Notice is issued solely for information, market-research, and acquisition-planning purposes. It does not constitute a solicitation and does not obligate the Government to issue a future solicitation or award a contract. Information submitted in response to this notice that is properly marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses are not offers and cannot be accepted by the Government to form a binding contract. Respondents are solely responsible for all costs and expenses associated with preparing and submitting a response. The Government will not reimburse respondents for any costs incurred.
-Market Research11/18/2026
Southern Arizona VA Health Care Systems requires a repair of the Yuma Mobile Vet Center. The damage is non-mechanical body work. Please see attachments for pictures and SOW for more information. Questions are due no later than November 2nd, 2026 at 11:00am Proposals shall be submitted no later than November 9th, 2026 at 11:00am
-Solicitation11/16/2026
AMENDMENT TO CORRECT PRICE/COST SCHEDULE. PLEASE SUBMIT OFFERS WITH THIS CORRECT VERSION. RESPONSE TO QUESTIONS.
-Combined Synopsis11/09/2026
This is a Sources Sought Notice (a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited. (b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only. (c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, kitchen equipment preventive maintenance and repair services outlined in this scope of work at the James J. Peters VA Medical Center 130 West Kingsbridge Road, Bronx, NY 10468 . The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811310 - and NAICS Size standard of $12.5 Million. The requirement is detailed in the Statement of Work section of this document. (e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0114. - Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic. If contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. The following information is required for determining procurement strategy and viability of sources: Set aside requirements have limitations on subcontracting. This service is located in Bronx, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work? If your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company? How many years experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity? How many jobs of this nature, of this scope and this complexity have you performed in the past five years? How many certified/licensed technicians does your company currently employ? - Contractors shall also identify any Federal Supply Schedules that may carry the desired services. - Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database, as well as for any intended subcontractors. - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. - Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. - Contractors shall include any relevant comments about the Attachment(s) if applicable. Below is the Limitation on Subcontracting Certificate of Compliance Clause. Please complete this as part of your response. 852.219-75Â VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction. As prescribed in 819.7011(b), insert the following clause: VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) (a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.] (i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. (ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating 18 U.S.C. 1001. (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee:_________________________ Printed Title of Signee: ____________________________ Signature: ____________________________________________ Date: _______________________ Company Name and Address:____________________________________________ STATEMENT OF WORK (SOW) (Abridged) Kitchen Equipment Preventive Maintenance Service General: This semiannual service contract covers maintenance and repairs for all kitchen equipment and any associated work required to complete those repairs. The purpose of this effort is to support the continuous operation of kitchen equipment located in Building 100 at the James J. Peters VA Medical Center in Bronx, NY. Description of Services: The contractor shall provide all personnel, equipment, supplies, transportation, tools, materials, supervision, and any other items and non personal services necessary to perform quarterly kitchen equipment preventive maintenance and repair services as defined in this Statement of Work (SOW). All equipment shall be maintained in accordance with the manufacturers recommendations. Seven emergency service visits shall be included in each option year. Any additional emergency service visits will be coordinated as a contract modification by the Contracting Officer (CO) under a separate CLIN line. Reports and Acceptance: Contractor will provide reports and findings to include repair estimates to the COR. Acceptance based on COR s approval. Safety Requirements: All work must comply with VA and OSHA safety standards. Including all construction and labor trades. Compliance: All work shall be completed in accordance with the following regulations. EC.02.05.01 Maintenance, EC.02.05.05 fire protection. FDA Food Code / 21 CFR 117.40. 29 CFR 1910 OSHA standards. VHA Directive 1439 Food Service Management. Protection of Government Property: During the execution of the work, the Contractor shall take special care to protect Government property, including interior and exterior building surfaces, furniture, walls, baseboards, and other affected areas. Any damage resulting from the Contractor s operations shall be repaired by the Contractor at no additional cost to the Government. Repairs shall include painting, refinishing, or replacement if necessary. All replacement materials must match the original materials. If the original material is no longer manufactured, the Contractor must obtain VA approval for the substitute material prior to installation. The Contractor shall comply with all OSHA and other applicable safety requirements during performance of the work. This includes, but is not limited to, taking all necessary precautions to protect patients, visitors, and staff at each location. The Contractor shall be responsible for any injuries and/or damage resulting from failure to adhere to these safety requirements. Security Requirements: Upon entering JJP-VA Medical Center the contractor and/or contractor employees will be required to show proof of identity (must have a valid photo ID) as well as pass through a security screening. All Contractors and Contractor personnel shall be subject to the same Federal security and privacy laws, regulations, standards, and VA policies as VA personnel, including the Privacy Act, 5 U.S.C. Regarding information and information system security. Vendors should be always escorted in the VA office buildings. The contractor will be accompanied by designated government personnel and shall sign in upon arrival. The C&A requirements do not apply; a Security Accreditation Package is not required. At no time during the execution of the duties listed in this statement of work will the contractor interface with VA systems or VA sensitive information. Services will not require connection to the VA network. Period of Performance: The expected period of performance for this requirement is a base year and four options years (which may or may not be exercised based on the needs of and at the discretion of the government). Work Hours and Scheduling Arrangements: Except by special alternative arrangement, scheduled preventive maintenance/services will be performed only during the facility s normal business hours (8:00 a.m. to 4:30 p.m. Monday through Friday excluding federal holidays). Downtime of kitchen machines for preventive maintenance/services must be scheduled through the Contracting Officer Representative (COR) at least 2 days in advance. When downtime for service/repairs is needed, the contractor shall notify the COR the same day (as soon as possible) upon observation. The Federal Holidays which are observed by the federal government are annotated below. -New Year s Day -Martin Luther King s Birthday -President s Day -Memorial Day -Juneteenth -Independence Day -Labor Day -Columbus Day -Veterans Day -Thanksgiving Day -Christmas Day -Any other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation). Equipment List: The contractor shall perform all preventative maintenance, maintain, check and calibrate according to OEM (Original Equipment Manufacturer) recommendations noted in the table below. Manufacturer Equipment Name Model GIRTON MANUFACTURING CART WASHER 80-0 HOBART FOOD MIXER H600 ROBOT COUPE CUTTER-MIXER ROBOCOUPExR10 HOBART MICROWAVE OVEN HM1600 ROBOT COUPE RANDELL HEATED STORAGE BASE SERVING UNIT RANHTD5BM VICTORY VICTORY REFRIGERATION CHILLER UNIT/BLAST CHILLER VBC35Q FOLLETT WARING ANCHOR BLENDER 38BL19 HOBART HOBART POT/PAN DISHWASHER AM15T HATCO CORPORATION OTIS SPUNKMEYER MINI OVEN OS-1 HATCO CORPORATION OTIS SPUNKMEYER MINI OVEN OS-1 AMANA REFRIGERATION AMANA MICROWAVE OVEN RC17S2 HATCO CORPORATION CONVEYOR TYPE TOASTER TOAST QWIK TQ-10 STERO COMPANY THREE TANK FLIGHT COMMERCIAL DISHWASHER STPCW-ER-24D ARISTO GRID LAMP PROD MOBILE DEMONSTATION TABLE MED2BTL ROBOT COUPE COMBINATION FOOD PROCESSOR R2 DICE WARWICK PROD BLENDER CB15G HOBART FOOD SLICER 2612 HATCO CORPORATION FOOD SLICER S13A ULTRA MAX GRIDDLE ELECTRIC COUNTERTOP 748TCHSA ALADDIN TEMP RITE LLC HEAT ON DEMAND ACTIVATOR IND7003 ALADDIN TEMP RITE LLC HEAT ON DEMAND ACTIVATOR IND7003 RATIONAL CONVI OVEN, ELECTRIC SCC-WE62 RATIONAL CONVI OVEN, ELECTRIC SCC-WE62 AMANA REFRIGERATION AMANA MICROWAVE CONVECTION AXP22TLT AMANA REFRIGERATION HEATED CABINET, MOBILE UH-12 DINEX MOBILE PLATE AND DISH DISPENSER DXIDPC20120 CUSTOM CHEF'S COUNTER CHEF'S COUNTER PRINCE CASTLE, LLC HEATED CABINET, COUNTERTOP DHB2PT-20B AMANA MICROWAVE OVEN, COMMERCIAL ACP RCS10DSE HATCO CONVEYOR TOASTER TQ-400H FWE (FOOD WARMING EQUIPMENT COMPANY, INC) MOBILE HEATED CABINET UHS-12 STAR STAR-MAX HOTPLATE, COUNTERTOP, ELECTRIC 501FF HATCO HOT FOOD WELL UNIT, DROP-IN HWBI-4DA ALTO-SHAAM WARMING DRAWER 500-1D RANDELL COLD FOOD WELL UNIT, DROP-IN FX-1-290 HATCO HEAT LAMP GRAL-60 HATCO HEAT LAMP GRAL-60 HATCO HEAT LAMP GRAL-60 General Maintenance Checklist for Kitchen Equipment: a. Visual and Physical Inspection Inspect exterior and interior surfaces for damage, corrosion, cracks, or misalignment. Verify doors, latches, hinges, handles, and access panels operate correctly. Check for loose or missing fasteners, screws, brackets, or hardware. Ensure safety labels, data plates, and warnings are present and legible. b. Electrical System Inspection Inspect wiring, terminals, connectors, and harnesses for fraying, heat damage, or looseness. Verify that power cords, plugs, and strain reliefs are intact. Test the operation of switches, controls, indicator lights, touchpads, and display panels. Confirm proper grounding and check electrical connections for tightness. c . Mechanical Components Inspect belts, gears, pulleys, bearings, and motor assemblies for wear or misalignment. Verify moving parts operate smoothly without abnormal vibration or noise. Clean and lubricate mechanical components per manufacturer instructions. Check seals, gaskets, and bushings for deterioration. d . Heating and Cooling Systems (applies to ovens, chillers, heated cabinets, heat lamps, wells) Test heating elements, burners, or induction components for correct function. Inspect evaporators, condensers, coils, and fans on refrigeration or blast chiller units. Confirm temperature sensors, thermostats, and controls operate within manufacturer specifications. Clean coils, vents, and heat exchangers to ensure proper airflow. Verify units reach and maintain required operating temperatures. e. Water and Plumbing Components Inspect hoses, supply lines, drains, valves, and pumps for leaks or blockages. Verify spray arms, nozzles, and jets (dishwashers, cart washers) rotate freely and are not clogged. Confirm correct water pressure and verify heaters/boilers (dish machines) operate properly. Clean strainers, screens, and traps. f. Safety and Interlock Systems Test door safety switches, emergency stops, and interlocks for proper operation. Verify over temperature and over current protection devices function. Ensure guards, shields, and protective covers are installed and secure. Confirm no bypassed safety features. g. Functional Performance Testing Run the equipment through a full operating cycle where applicable. Check time, temperature, speed, and program accuracy. Verify conveyor motion (for toasters), cycles (dish machines), agitation/mixing speed (mixers), and blade rotation (processors). Confirm output matches manufacturer expectations. h. Cleaning and Sanitation Clean interior and exterior surfaces using approved materials. Remove residue, grease buildup, scale, and debris. Sanitize food-contact surfaces following VA kitchen protocols. Clean filters, screens, and ventilation openings. i. Consumables and Replacement Components Inspect and replace worn blades, mixers, grates, screens, filters, lamps, and gaskets as needed. Check condition of baskets, racks, trays, and accessories. Verify the availability of critical spare parts. j. Documentation and Reporting Record all findings, work completed, parts replaced, and deficiencies. Note equipment that requires follow up repair, adjustment, or vendor service. Report any unsafe conditions immediately. Provide estimates for repairs. Verify PM tag updates and ensure logs reflect manufacturer required procedures.
-Market Research11/13/2026

Additional Details

Solicitation Number

36C24226Q0723

Archive Date

Jul 23, 2026

Office Address

ALBANY, NY, 12208