Notice ID: 76a1767c0c764110ad7c8978de4dee4fAward NoticeAwarded
F103--Philadelphia Water Testing
Awarded on February 14, 2023. Full description on SAM.gov.
Awarded tounder 36C24423D0052 (source: SAM.gov award notice)• $425.5K
Overview
- Posted
- February 14, 2023
- Notice type
- Award Notice
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 541380: Testing Laboratories and Services
- Agency
- Department of Veterans Affairs
Notice details
- Place of performance
- Department of Veterans Affairs Philadelphia VAMC 3900 Woodlawn Avenue, Philadelphia, PA, 19104
- Last updated
- Dec 4, 2025
- Award date
- Feb 14, 2023
- Award amount (SAM.gov award notice)
- $425.5K
Identifiers
- Solicitation number
- 36C24423Q0181
- Notice ID
- 76a1767c0c764110ad7c8978de4dee4f
- Award number (PIID)
- 36C24423D0052
Description
Solicitation 0001 is issued to answer contractor questions. All other terms and conditions remain unchanged to include the deadline for questions. Questions Regarding Solicitation 36C24423Q0181 Solicitation states it is being competed as a Total Small Set-Aside. This work should be competed as a SDVOSB as there are at least 2 SDVOSBs who can do this work. There is no requirement for a qualified SDVSOB to be located in a specific geographical area. Will government change this requirement to SDVSOB Set-aside? No Several postings at SAM.gov, to include requests for information and actual solicitations issued with veteran owned business set-asides. Data gathered through actual postings of this requirement do not support a reasonable expectation that two or more veteran owned small business concerns will submit offers. his solicitation does include VAAR 852.215-70 and 852.215-71 which takes into consideration socioeconomic factors in accordance with the clauses and provisions of the solicitation. Section 5.2.1: The ELITE Laboratories must also be able to determine if the Legionella detected in environmental samples is the species Legionella pneumophila serogroup 1-14 (and differentiate between them), and non-pneumophila species). Level Heterotrophic Plate Count1 Process Triggered by Test Results <10,000 CFU/ml Maintain water chemistry and biocide levels per the Cooling Tower Management Plan. Would the government consider changing the requirement to distinguish between all Legionella pneumophila serogroups to being able to distinguish between serogroup 1 and serogroups 2-14 as the remediation of Legionella does not depend on what serogroup is detected and for a HCA LD investigation, the identification would be done on a molecular level. Same question for non-pneumophila species. Serotyping and speciation are very expensive. No 10,000 CFU/ml to <100,000 CFU/ml Within 8 hours, increase the biocide concentration and/or chemical treatment to mitigate the issue. Magnitude of increase in level and duration must be documented with basis of review and decision. Review treatment program and facility plan and revise as required; retest water within 3-7 days. Continue retesting and interpret in accordance with this Table until level 1 is reached. Section 3.5.1.2.10: VHA Engineering Standard Level (1-3). Will the government define these levels so we can ensure the methods being priced will adhere to this requirement? 100,000 CFU/ml Within 8 hours, increase the biocide concentration and/or chemical treatment to mitigate the issue. Magnitude of increase in level and duration must be documented with basis of review and decision. Within one week, perform remediation of the cooling tower by removing cooling tower from service, hyperhalogenating2, cleaning, and flushing. Review treatment program and facility plan and revise as required; retest water within 3-7 days. Continue retesting and interpret in accordance with this Table until level 1 is reached. 1. Performed by an appropriately accredited Laboratory (e.g. NELAP, AALA) 2. At a minimum, dose the cooling water system with 5 to 10 ppm Free Halogen Residual for at least 1 hour; pH 7.0 to 7.6. Section 3.5.1.4.1.11: Compliance indicate if each test meets standards and 3.5.1.5.2 Compliance indicate if each test meets standards. Will the government provide these standards so we can ensure the methods being priced will adhere to this requirement? SPS standards are AAMI TIR34 (critical water standards) Backflow preventers standards are AAMI TIR34 (utility water standards) 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICESNOV 2021 States that a signed offer/quote needs to be submitted if there is no SF 1449. Do vendors need to submit a signed letter in Section 1 Administrative/Regulatory volume? 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (NOV 2021) (a) North American Industry Classification System (NAICS) code and small business size standard. The NAICS code(s) and small business size standard(s) for this acquisition appear elsewhere in the solicitation. However, the small business size standard for a concern that submits an offer, other than on a construction or service acquisition, but proposes to furnish an end item that it did not itself manufacture, process, or produce is 500 employees if the acquisition (1) Is set aside for small business and has a value above the simplified acquisition threshold; (2) Uses the HUBZone price evaluation preference regardless of dollar value, unless the offeror waives the price evaluation preference; or (3) Is an 8(a), HUBZone, service-disabled veteran-owned, economically disadvantaged women-owned, or women-owned small business set-aside or sole-source award regardless of dollar value. (b) Submission of offers. Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation. Offers may be submitted on the SF 1449, letterhead stationery, or as otherwise specified in the solicitation. As a minimum, offers must show (1) The solicitation number; (2) The time specified in the solicitation for receipt of offers; (3) The name, address, and telephone number of the offeror; (4) A technical description of the items being offered in sufficient detail to evaluate compliance with the requirements in the solicitation. This may include product literature, or other documents, if necessary; (5) Terms of any express warranty; (6) Price and any discount terms; (7) "Remit to" address, if different than mailing address; (8) A completed copy of the representations and certifications at Federal Acquisition Regulation (FAR) 52.212-3 (see FAR 52.212-3(b) for those representations and certifications that the offeror shall complete electronically); (9) Acknowledgment of Solicitation Amendments; (10) Past performance information, when included as an evaluation factor, to include recent and relevant contracts for the same or similar items and other references (including contract numbers, points of contact with telephone numbers and other relevant information); and (11) If the offer is not submitted on the SF 1449, include a statement specifying the extent of agreement with all terms, conditions, and provisions included in the solicitation. Offers that fail to furnish required representations or information, or reject the terms and conditions of the solicitation may be excluded from consideration.
Award Overview
Award Number
36C24423D0052
Award Amount (SAM.gov award notice)
$425.5K
Award Date
Feb 14, 2023
Awardee
Awardee UEI
KMQMRUAJ6JK9
Awardee CAGE Code
1HJH9
Original Solicitation
Notice ID: 76a1767c0c764110ad7c8978de4dee4f
Posted Date: Feb 14, 2023
Original Response Deadline: Not specified
Task Orders Under This IDV
Top 10 by total obligated
- $114.5KSigned Feb 13, 2026
- $112.3KSigned Feb 13, 2025
- $90.1KSigned Dec 16, 2024
- $85.1KSigned Jan 17, 2024
- $85.1KSigned Feb 14, 2023
- $83.5KSigned Nov 2, 2026
- $68.0KSigned Aug 11, 2025
- $59.1KSigned Aug 5, 2024
More From This Vendor
Top 5 most recent
- $165.3KSigned Nov 10, 2026
- $83.5KSigned Nov 2, 2026
- —Signed Oct 14, 2026
- $81.3KSigned Oct 13, 2026
- $311.5KSigned Oct 1, 2026
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24423Q0181- Combined Synopsis
- Awarded
This opportunity has been awarded.
- 3×Combined SynopsisJan 5, 2023
F103--Philadelphia Water Testing
- AwardedCurrentFeb 14, 2023
F103--Philadelphia Water Testing
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C24423Q0181
Archive Date
Mar 1, 2023
Office Address
PITTSBURGH, PA, 15215