Notice ID: 860779e4308e43eba0945d24c4cb067dPresolicitationArchived
6515--Zoll Zenix Series Advanced Defibrillators Brand Name or Equal to
Archived on June 1, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:00 PM EDT
- Posted
- May 15, 2026
- Notice type
- Presolicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244)
- Place of performance
- Wilmington VA Medical Center, Wilmington, Delaware, 19805
- Last updated
- Oct 30, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24426Q0582
- Notice ID
- 860779e4308e43eba0945d24c4cb067d
Description
STATEMENT OF NEED Zoll Zenix Series Advanced Defibrillators INTRODUCTION/BACKGROUND: Wilmington VAMC requires modern, reliable hospital defibrillator/monitors to support advanced resuscitation and patient transport within the facility. The ZOLL Zenix platform (or equal) provides multi-parameter monitoring, defibrillation, pacing, CPR feedback, and data integration capabilities required for patient care. The following is being requested to be utilized by our two Rapid Response Teams in ICU and ED to respond to any code alerts within the main bldg. and outside bldg. areas. As of right now our outside bldgs. only have the capability to support AED only. With the Zoll Zenix series this is particularly suited for more advanced life support situation, and the compact size and weight make it easy for our Rapid Response Team to transport. Currently we have Zoll brand defibrillators R series on our emergency crash carts and all the necessary supplies which staff are already trained on. The Zoll Zenix has the same defib connection pads as our R series. PRODUCT/SPECIFICATIONS: SCOPE: The Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Zoll Zenix Series Advanced Monitor/Defibrillator because it meets our needs for enhancing patient safety, accessibility, portability, and advanced monitoring capabilities. This is a brand name or equal for the following: Zoll Zenix. Required specifications/all equivalents must meet the following: General Weight: 13.2 lbs. (5.99 kg) with battery Dimensions: 9.4 in (23.9 cm) x 10.3 in (26.2 cm) x 8.6 in (21.8 cm) Enclosure Protection: Solid foreign object: EN 60529, IP3X Water: EN 60529, IP3X Operating Temperature: 32 to 104°F (0 to 40°C) Transport and Storage Temperature: -4 to 41°F (-20 to 5°C) Humidity: 15 to 95% (non-condensing) Vibration: 60068-2-64 Shock: 60068-2-27, 50g, 6ms half sine Drop: IEC 60068-2-31, 18 in (0.5 meters) functional drop 60601, 78 in (2 meter) safety drop Altitude: -1,276 to 15,000 feet (-389 to 4,572 meters) Monitor/Display Size: 8.4 in (21 cm) diagonal Type: Color LCD 800 x 600 touchscreen Display: Up to 4 waveforms Defibrillator Waveform: Rectilinear Biphasic waveform Patient Population: Adult, pediatric, neonatal/infant Patient Impedance Range:15 to 300 ohms (hands-free electrodes or external paddles) 7 to 300 ohms (internal paddles) Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 85, 100, 120, 150, 200 joules Charge Time: Less than 7 seconds with a new, fully charged battery at 77°F (25°C) for 15 successive charges Rapid Shock: Shock/No Shock decision with pre-charge of the device in 4 to 5 seconds Advisory Defibrillation: Shock Advisory Function prompts rescuers through ECG analysis, shocks and CPR throughout a rescue event. The ECG is analyzed with shock/no shock decision provided to rescuer. Pacer Type: External transcutaneous pacing Pulse Types: Rectilinear, constant current Pulse Width: 40 ms +/- 2 ms Pacer Rate: 30 - 180 PPM (+/- 1.5% for Fixed Mode) Output Current: 10 - 140 mA +/- 5% or 5 mA (whichever is greater) Minimum Pacer Output: 10 mA Modes: Demand, Fixed Output Protection: Fully defibrillator protected and isolated Cardioversion Synchronized defibrillator pulse to patients' R wave. "SYNC" message displayed on monitor and markers shown on both monitor and recorded ECG. Real-Time Clinical Feedback See-Thru CPR: See-Thru CPR: Removes compression-related artifact from the ECG via an adaptive filtering technique. Real CPR Help: Real-time depth and rate feedback. CPR Dashboard: Numeric readout of pediatric and adult depth and rate, release indicator, perfusion performance indicator (PPI). Real BVM Help: Provides ventilation feedback including rate and tidal volume in ml ECG Monitoring Input: 3-lead, 5-lead, 12-lead cables, paddles, therapy electrodes with MFC cable Lead Selections: Paddles, Pads, I, II, III, AVR, AVL, AVF, V1-V6. Heart Rate Range:20 - 300 beats/minute Heart Rate Accuracy:3 BPM or +/- 3%, whichever is greater ECG Size Range:0.25, 0.5, 1, 2, 3, 4 cm/mV ECG Sweep Speed: User selectable25 mm/sec or 50 mm/sec External Patient Monitor Connections ECG Output: 1.0V/cm of deflection on recorder; <25ms delay from patient CO2 Patient Population: Adult, pediatric, neonatal/infant ET Tube Diameter: Single Patient Use (SPU),SPU Adult/pediatric: >4.0mm SPU Pediatric/neonatal/infant: 4.0mm Accuracy for all Conditions: +/-(0.3 kPa + 4% readings Respiration Rate: 0 to 150 +/- 1 breaths/minute Warm-Up Time: < 10 seconds (concentrations reported and full accuracy) Non-Invasive Blood Pressure Patient Population: Adult, pediatric Method: Oscillometry Control: Automatic and manual measurement Auto Mode Intervals: 1, 2, 3, 5, 10, 15, 30, 60 mins Masimo RD SET SpO SpO2 Saturation Range: 0 - 100% SpO2 Saturation Accuracy: No Motion: Adult/pediatric/infant: 70 - 100%, +/-2% Neonate: 70 - 100%, +/- 3% Motion: 70 - 100%, +/- 3% adults/pediatrics/infants/neonates SpO2 Pulse Rate Range: 25 - 240 beats/minute Masimo RD Rainbow Set SET Masimo rainbow SET SpCO: Range: 0 99% Accuracy: 1 40%, ± 3%, Adults/pediatrics/infants Masimo rainbow SET SpMet: Range: 0 99% Accuracy: 1 15%, ± 1%, Adults/pediatrics/infants/neonates Masimo rainbow SET SpHb: Range: 0 25 g/dL, 0-15.5 mmol/L,0-250 g/L Accuracy: 8-17 g/dL, 1 g/dL adults/pediatric Masimo rainbow SET SpOC: Range: 0 to 35 ml/dL Masimo Perfusion Index (PI): Range: 0.02% - 20% Masimo Pleth Variability Index (PVI): Range: 0.02% - 100% Patient Log Files Full Disclosure Data Storage: Contains continuous waveform data, treatment markers, CPR data, 12-lead snapshots, monitor snapshots, automatic snapshots, trend records and vital signs numeric updates. Full Disclosure Storage Capacity: Up to 150 patient cases with FIFO storage or to the maximum storage capability Printer / Recorder Type: High resolution thermal array Annotation: Snapshots, alarms, and treatment summaries Paper Width: 80 mm Paper Speed: 25mm and 50mm per seconds configurable Delay: 6 seconds Record Modes: Manual or automatic configurable Battery Type: Rechargeable lithium ion,10.8 Vdc, 8.61 Ah, 93 Wh Capacity: At least 4 hours of continuous monitoring with ECG, SpO2, CO2, three invasive pressure channels, two temperature channels, NIBP measurements every 15 minutes, wireless communication disabled, display brightness set to 10%, and volume set to medium (with a new, fully charged battery operating at room temperature) Weight: 1.5 lb. Recharge Time: 5 hours to fully charge, max. When charged by Zenix AC Power Adapter: 100 240 VAC 50-60 Hz, 160 VA External Data Transfer Data Transfer Port: USB (Type A and C), Wi-Fi, Bluetooth Monitor Port: Video Out Wi-Fi: 802.11 a, b, g, n and ac Bluetooth: 5.0 TRAINING: Must provide training for the rapid response teams, nurse educators and bio-med. DELIVERY: Delivery shall be within 60 days after receipt of contract. Deliver equipment to: Wilmington VA Medical Center 1601 Kirkwood Hwy Wilmington, DE 19805-4917 Government personnel, other than the Contracting Officer, have the authority to change or alter these requirements. The POC shall clarify technical points or supply relevant technical information, but no requirements in this scope of work may be altered as a sole result of such verbal clarification.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Vendor
ZOLL MEDICAL CORPORATIONContract end date
Sep 30, 2026
NAICS
334510
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C24426Q0582_1.docx
28 KBAdded in Presolicitation version 4Posted
Links (1)
- Wilmington VAwww.va.govPosted
Lifecycle
- 4Version 4PresolicitationArchivedCurrent
6515--Zoll Zenix Series Advanced Defibrillators Brand Name or Equal to
- 6Version 6SolicitationArchived
Type changed from Presolicitation to Solicitation
6515--Zoll Zenix Series Advanced Defibrillators Brand Name or Equal to
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
SOURCES SOUGHT NOTICE: The Department of Veterans Affairs, Network Contracting Office 4 (NCO 04), is conducting a market survey to identify potential sources to provide a Brand Name only Philips ST80i Stress Test System for the Wilmington VA Medical Center (WVAMC)- 1601 Kirkwood Hwy, Wilmington De 19805 . This notice is issued for informational planning purposes only and is not a request for quote or announcement of a solicitation. Submitting information for this notice is voluntary and VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice. No solicitation is available at this time. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. The purpose of this market research is to identify capable sources that are both experienced and qualified to supply a Philips ST80i Stress Test System in accordance with statement of work. The North American Industry Classification System Code (NAICS) is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing, and the small business size standard is 1,250 employees for this type of effort. Vendors must be registered in the System for Award Management (SAM) at https://www.sam.gov and shall complete electronic annual representations and certifications in SAM prior to award of contract. If you are responding as a Service-Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses (SDVOSB s and VOSB s), your company must be registered in VetCert and maintain a current certification (https://search.certifications.sba.gov/ ). CAPABILITY STATEMENT AND DOCUMENTATION: Companies are to provide a summary of your firm s capabilities, experience, and knowledge in providing these services. Sources are asked to provide the following information: 1. Company information: Company Name Company Address Company uei SAM Company NAICS Code(s) Point of Contact Name Point of Contact Phone Number Point of Contact Email Address Company Website (if available) 2. The North American Industry Classification System Code (NAICS) is 334510 Electronic and Precision Equipment Repair and Maintenance, and the small business size standard is 1,250 employees. Based on this information, please indicate whether your company is a: Service-Disabled Veteran Owned Small Business (SDVOSB) Veteran Owned Small Business (VOSB) 8(a) HUB Zone Small Business Women Owned Small Business Small Disadvantaged Business (SDB) Small Business Concern Large Business 3. Provide a summary of your firm s Ability/ Capability to meet the product described in this notice (see attached SOW). 4. Government contracts for these products in the last 3 years. Include: Government Agency Contract Number Dollar Value Period of Performance Government Point of Contact Information (name, email, phone number) Information regarding your company s capacity and capability to provide such products are to be submitted electronically on or before 5:00 PM, Wednesday, 11/11/2026 addressed to Christa Stine, Contract Specialist christa.stine@va.gov. | - | Market Research | 11/11/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | - | Combined Synopsis | 12/01/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with FAR part 12. This announcement constitutes the only solicitation. Proposals are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0004 is issued as a Request for Proposals (RFP) for Image-Guided Surgical Navigation Systems. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A - PRICE COST SCHEDULE_NX EQ Image-Guided Surgical Navigation System for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide NX EQ Image-Guided Surgical Navigation Systems that meet the salient characteristics listed in ATTACHMENT B PRODUCT DESCRIPTION. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | - | Combined Synopsis | 11/05/2026 |
| - | Awarded | Open | |
See attached document: 36C10X26R0062 See attached document: SF30 36C10X26R0062 0002 | - | Solicitation | 10/16/2026 |
Additional Details
Solicitation Number
36C24426Q0582
Archive Date
Jun 1, 2026
Office Address
PITTSBURGH, PA, 15215