Notice ID: 97afc708216548eca198b654bb4452e7Sources Sought

6515--Full Body Phototherapy

Responses closed . Full description on SAM.gov.

Overview

Response deadline
6:00 AM EST
Posted
October 29, 2026
Notice type
Sources Sought
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
244-NETWORK CONTRACT OFFICE 4 (36C244)
Place of performance
Department of Veterans Affairs Wilmington VA Medical Center, Wilmington, DE, 19805
Last updated
Oct 29, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24427Q0046
Notice ID
97afc708216548eca198b654bb4452e7

Description

Page 5 of 6 Page 1 of In accordance with FAR 10, Market Research, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to the Sources Sought Notice. The purpose of this announcement is to gain market research knowledge of potential qualified sources and their size classification. The Department of Veterans Affairs, Wilmington VA Medical Center, 1601 Kirkwood Hwy, Wilmington, DE 19805, is seeking potential sources capable of providing (1) one full body phototherapy unit in accordance with the Draft Statement of Need (SON) below. Please include the following information in your response: Company name Address Contact person name, phone number and email address SAM UEI # Business size/classification/type (i.e. 8a, Hubzone, SDVOSB, VOSB, etc.) FSS/eCAT/SAC/NAC/NITTAC/NASA SEWP or any Government held contract, if applicable provide the number. NAICS: 339112 Size Standard: 1000 Employees Provide brochures, pamphlets, hyperlinks, or any other materials necessary to determine material capabilities including special features and any express or implied warranties. Please answer the following questions: Are you the manufacturer, distributor, or equivalent solution to the above items? If not, can you provide additional information, as shown below? This confirms compliance with the nonmanufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, Point of Contact, and size status (if available). If you re a small business, are you an authorized distributor/reseller for the items identified above? If so, please include your letter of authorization on the OEM s letterhead. If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is changed, assembled, or modified. Responses to this Sources Sought Notice shall be submitted directly via email to jefferson.mann@va.gov. Responses that only include generic marketing material and do not provide for capability to meet requirements listed in the SON may not be considered. Responses must be received no later than 6:00 am ET, 11/10/2026. No solicitation document is available at this time. This notice is simply for Market Research Purposes Only. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The VA will not reimburse any potential contractors for any costs associated with this Sources Sought Notice. Statement of Need Department of Veterans Affairs Wilmington VA Medical Center, Wilmington, DE 19805 INTRODUCTION/BACKGROUND: The Dermatology Department at the Wilmington VA Medical Center, Wilmington, Delaware, is currently using a full body phototherapy cabinet that is at its end of life (24 years old). The current full body phototherapy is requiring repairs where replacement parts are no longer being produced. Full body phototherapy is a medical treatment that exposes the patients entire skin surface to controlled doses of ultraviolet light to calm overactive immune cells, reduce inflammation, and relieve chronic skin symptoms. OBJECTIVE: The Patient Care Services (PCS) Department at Wilmington VAMC requires the one-time acquisition of 1 (one) full body phototherapy, with a minimum of 1 year manufacturer s service warranty and minimum lifespan of 5 years. REQUIREMENTS: Supply 1 (one) full body clinical phototherapy cabinet designed for treatment of psoriasis, vitiligo, eczema, atopic dermatitis, and other dermatologic conditions. Salient Characteristics Minimum operational lifespan of five years Minimum one-year manufacturer s service warranty Forty-eight (48) high-intensity, 6-foot ultraviolet lamps Configurations that support narrowband ultraviolet B (NB-UVB), ultraviolet A (UVA), and combination UVA/NB-UVB therapy Integrated dosimetry system that automatically measures ultraviolet output and ends treatment when the prescribed dose has been delivered Touchscreen user interface that permits authorized staff to enter prescribed dose or treatment time, view treatment status, view system alerts, and start/stop treatment Patient-accessible emergency stop control Automatic treatment termination when the prescribed dose or treatment time has been reached Interior and access configuration that accommodates wheelchair patients Temperature-management system with patient-controlled cooling fans Ultraviolet-transmitting acrylic shields that protect the lamps, reduce maintenance, and prevent patient contact with the bulbs Ability to configure treatment protocols and maintain treatment history locally on the device. The equipment shall not require connection to a VA network or external patient-record system. Vendor must offer yearly maintenance services as part of their commercial catalog for any proposed equipment Program Office Point of Contact (POC) The identified POC and technical representative for this acquisition will be provided at contract award. No Government personnel, other than the Contracting Officer, have the authority to change or alter these requirements. The POC shall clarify technical points or supply relevant technical information, but no requirements in this scope of work may be altered as a result of such verbal clarification. DELIVERY: Deliver to: VAMC Wilmington 1601 Kirkwood Hwy 6th Floor, Building 1 Wilmington, DE 19805 Attention: Dermatology Department

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Dec 31, 2025

NAICS

339112

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Jefferson Mann
Contract Specialist

Documents

Files (1)

  • 36C24427Q0046.docx

    35 KBAdded in Sources Sought version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Sources SoughtCurrent

    6515--Full Body Phototherapy

    Notice 97afc708216548eca198b654bb4452e7 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
SIX (6) MIDMARK 626 BARRIER FREE EXAM CHAIRS
-Market Research11/19/2026
This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center, 302 San Antonio TX 78240 for the procurement for the Multilab Series II Roorda Vascular System W/DICOM, integration capabilities for San Antoino Veterans Health Care System VA, TX 78229 Background and Requirement: San Antiona Veteran Healthcare System, 7400 Merton Minter, San Antonio, Tx 78229 is seeking a Multilabel Series II Roodra Vascular System W/DICOM. The purpose of this procurement is to acquire, deliver, install, test, and deploy four (4) Multilabel Series II Roodra Vascular Systems with DICOM integration capabilities. The required system is the Unetix Multilab II Roorda with DICOM functionality. The objective of this procurement is to provide the surgical service with advanced vascular diagnostic equipment that seamlessly integrated with existing imaging and clinical information systems through DICOM connectivity for their vascular clinic. The Unetix Multiab II Roorda is the only known vascular diagnostic system that is fully compactable with the facility s VascuPro network and reporting platform. Procuring this equipment will ensure continuity of operations, maintain interoperability with current infrastructure, and support efficient delivery of patient care without the need for costly system modification or workflow disruptions at 7400 Merton Minter, San Antonio, Tx 78229. If this is an item your business can provide, please respond to this Sources Sought Notice by 11:00 AM Central Time on Thursday, 19 November 2026. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: a. where is the item manufactured, the VA is interested in procuring items manufactured in the United States. If you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item. Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept gray market items. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Responses should include: (1) Business Name (2) Business Address (3) Point of Contact - Name - Phone Number - E-mail Address (4) SAM UID Number (5) NAICS code (6) Business Size: SMALL or LARGE (7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc. (8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicable (9) GSA/FSS Contract Number if applicable All businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to Michelle Cunningham at michelle.cunningham@va.gov. DISCLAIMER: THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.
-Market Research11/19/2026
Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. 1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. 2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care. 2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. 3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. 4.Period of Performance: The product is requested to be delivered no later than December 19th. 5.Type of Contract: Supply: Firm, Fixed Price. 6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T Equipment Requirement: Minimum Required Features and Specifications Type / Intended Use: Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications. Must provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes. Frequency & Imaging Performance: Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate. Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system). Biopsy and Procedural Capability: Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange. Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments. Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures. 4. Design & Ergonomics Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use. Must include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle. Must be designed for one-handed operation and compatible with sterile probe covers. 5. Compatibility Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms. Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters. 6. Cleaning & Sterilization Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes. Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide. 7. Construction & Safety Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards). Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits. Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use. Summary Table Feature Category Requirement Type Triplane transrectal prostate ultrasound transducer Frequency 4 14 MHz Imaging Modes B, M, Color Doppler, Power Doppler (Elastography optional) Biopsy Capability Integrated dual-plane biopsy guide Needle Compatibility 17 18 G Operation One-handed, Smart Button on probe Sterilization Fully immersible, high-level disinfectable Compatibility bk3000, bk5000, bkActiv, bkSpecto Intended Use Prostate imaging and biopsy guidance Condition New OEM product, OEM warranty
-Market Research11/16/2026
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL. General Requirements: Brand Name or Equal The below products are known to meet the governments needs all equal parts will be considered. 950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal Salient Characteristics: Therapy Profiles: Must support Invasive ventilation Must support Noninvasive ventilation Must support Nasal High Flow therapy. Temperature Probes: Must have no external temperature probes Must incorporate internal temperature probes that do not require special disinfection processing Circuit Compatibility: Must be compatible with single heated circuits for non-invasive ventilation. Must be compatible with double heated circuits for invasive ventilation. User Interface: Must have a simple user interface Must include touch screen monitors to create setting modifications Must allow mode changes Must allow comfort setting adjustments Must display and troubleshoot alarms Must provide access to Information and Service menus Alarms: Must have built-in alarms for various conditions including but not limited to: 1. High Temperature alarms 2. Low Temperature alarms 3. Water Out alarms 4. Circuit Disconnect alarms 5. Reverse Gas Flow alarms 6. System check alarms Compatibility: Must be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC, Specifically, must be compatible with Medtronic 980 ventilators Specifically, must be compatible with Philips V60 BiPAP devices Specifically, must be compatible with Nihon Kohden 330, 440, and 550 ventilator systems All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 8:00 AM (Central Standard Time), 23 November 2026. 36C25227Q0090 950 Humidifier Heaterbase shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
-Market Research11/23/2026
This is a SOURCES SOUGHT NOTICE ONLY. This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Response to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Central Arkansas Veterans Health Care System is seeking preferably Service-Disabled Veteran Owned Small Businesses (SDVOSB), or Small Businesses (but will accept other than small business for market research purposes), capable of providing Medtronic ManoScan Eso Z catheters for the Central Arkansas Veterans Health Care System. It is noted that Limitations on Subcontracting requirements will apply to a future solicitation and contract for this requirement. Contractors who are contemplating their interest and/or participation in this procurement should familiarize themselves with these requirements as adherence will be required. See DRAFT Performance Work Statement for detailed description of this requirement. The Government s intent is to identify vendors capable of providing the Medtronic ManoScan Eso Z catheters that meets or exceeds the salient functional characteristics described in the Draft Performance Work Statement. Vendors offering equivalent products must provide product literature demonstrating how their item meets the Government s minimum essential requirements. The NAICS code is NAICS 339112 Surgical and Medical Instrument Manufacturing, and the Size Standard is 1,000 Employees. Responses must be received by no later than 12:00 p.m. Eastern Time, November 13, 2026. Responses shall be emailed to jacqueline.ambala@va.gov. Facsimile or Telephonic responses will not be accepted. Responses shall contain Capabilities Statements to include the following: Contractors shall also provide the following: Contractor name: ___________________________________________ Point(s) of contact name: ______________________________________ Address: ___________________________________________________ Telephone number: ___________________________________________ Email address: _______________________________________________ Company's business size: _______________________________________ UEI #: ______________________________ CAGE Code: _______________________________ Proof that you are an authorized dealer and/or any qualifying certifications that may be required to perform the service. Is your company considered a small business concern, Small Business (SB), Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Historically Underutilized Business Zone (HUBZone), or 8A concern under the NAICS 339112? Does your company have the services available under any Government Wide Agency Contract (GWAC), General Service Administration (GSA), Federal Supply Schedule (FSS), Indefinite Delivery Indefinite Quantity (IDIQ), and/or Blanket Purchase Agreement (BPA) contract? If so, please identify the contract number for the government to review as part of this Market Research. Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award. SAM: SAM.gov | Home SBA Small Business Search: https://search.certifications.sba.gov/ Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) VETS-4212 Federal Contractor Reporting | U.S. Department of Labor (dol.gov)
-Market Research11/13/2026

Additional Details

Solicitation Number

36C24427Q0046

Archive Date

Nov 25, 2026

Office Address

PITTSBURGH, PA, 15215