GovChime
Notice ID: 2a5fed17cd2d4759beba54eeea459f8eSolicitation

6530--UVC PASS THROUGH WINDOW (VA-21-00026166)

Archived on March 21, 2021. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:59 PM UTC−05:00
Posted
February 10, 2021
Notice type
Solicitation

Notice details

Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Place of performance
Department of Veterans Affairs VAMC 10 N Greene St, Baltimore, 21201
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C24521Q0170
Notice ID
2a5fed17cd2d4759beba54eeea459f8e

Description

Page 2. Statement of Work (SOW) Censis Baltimore Reference #: 512-21-1-198-0004 Overview: Tracking enhances the ability of VA to ensure patient and staff safety by providing reasonable assurance that instruments have been processed in accordance with regulatory guidelines and individual instrument manufacturer s Instructions for Use (IFU) for reusable medical equipment (RME) and dental/medical-surgical instrumentation. Objective Sterile Processing Service requires sterile and disinfected medical instruments and equipment. Many heat-intolerant and non-immersible medical devices must be hand washed, however, there are no options for disinfecting them after washing. They are passed through to the Preparation room washed, but not disinfected. Staff must use hand hygiene and disinfecting their workstations to compensate. Section 1: SCOPE The UVC disinfector safely and quickly disinfects hand-washed items at the transfer window between the Decontamination Area and the Prep Room. Studies have demonstrated that manually cleaned devices have a higher bacterial colony-forming units (CFU) count than the machine-washed items. The unit s UVC light radiation significantly reduces bacterial CFU counts, thereby improving the safety of handling these instruments. The unit uses no harmful chemicals, consumables, or antimicrobial wipes, and offers a standardized, repeatable decontamination process that helps eliminate human error and make instruments safer to handle. The VA has identified two units which would meet our specifications. While the VA has identified these two units, contractors are welcome to propose any units which fall within the range of the two described here. This is considered a name brand or equal. The first identified unit is the ClorDiSys Flashbox UV-C Disinfection Chamber and their specs are: Usable Space: 14 H x 21.25 D x 21.25 W; Overall Dimensions: 25.75 H x 24 D x 24 W; Power: 115 VAC, 60 HZ, 3 Amps; UV-C Output: 60 mJ/cm2 per minute (1000 W/cm2) of UV intensity. The second identified unit is the Light Progress USA UV-Box-E3 and the specs are: Internal Dimensions: 23.6 H x 19.7 L x 12.2 P; Exterior Dimensions: 29.5 H x 21.7 L x 13.8 P; Total Consumption: 120 W; Light Progress 253.7 nm UV-C high output lamp. Section 3: 3.1 REQUIREMENTS 3.2 Security The C&A Requirements do not apply to this procurement; thus, a Security Accreditation Package is not required.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24521Q0170
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. SolicitationFeb 3, 2021

    6530--UVC PASS THROUGH WINDOW (VA-21-00026166)

    Notice 1bd596dbcc7a4fbaab746c6d28abda76 on SAM.gov

  2. Pre-SolicitationFeb 3, 2021

    6530--UVC PASS THROUGH WINDOW (VA-21-00026166)

    Notice dd9f0293a9a046e2abe5907dfa6a832b on SAM.gov

  3. SolicitationCurrentFeb 10, 2021

    6530--UVC PASS THROUGH WINDOW (VA-21-00026166)

    Notice 2a5fed17cd2d4759beba54eeea459f8e on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C24521Q0170

Archive Date

Mar 21, 2021

Office Address

LINTHICUM, MD, 21090