DJ10--Fluid Mesh Optimization Camera Assessment

Archived on July 8, 2022. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM UTC−04:00
Posted
June 22, 2022
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)

Notice details

Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Place of performance
Martinsburg WV VA Medical Center 510 Butler Ave. Martinsburg, WV. 25405
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C24522Q0603
Notice ID
b9066d07dca8416c8283fb10ed8294e7

Description

STATEMENT OF WORK Fluidmesh Optimization Assessment Brand Name Only 1.0 Scope of Work: The contractor shall assess the Fluidmesh system and recommend specific repairs 1.1 Background: The current Fluidmesh system has times when video is not available, or latency causes the video to be unusable. 1.2 Type of Contract: Firm-Fixed Priced Service 1.3 Location: Martinsburg VA Medical Center 510 Butler Ave. Martinsburg, WV. 25405 GENERAL REQUIREMENTS Overview The contractor will assess the existing Fluidmesh system. The Fluidmesh system consists of 18 cameras with Fluidmesh antennas. These antennas transmit to four antennas on the hospital roof. The four antennas are connected to a network switch in the hospital. The data is transmitted over the network to four recording servers. The current system is approximately 75% functional. Issues include complete video outage, latency, or unresponsiveness to commands. These issues may occur at any time. At other times cameras are completely functional. Frequencies in the 5.2 to 5.4 mhz band cannot be used All work will be completed between the hours of 7:00 a.m. and 4:00 p.m. Monday thru Friday except Federal holidays, unless prearranged with the COR. Contractor will observe all Martinsburg VA Medical Center Infection Control protocols. Contractor must have experience installing Fluidmesh devices and networks for video The C&A requirements do not apply, and a Security Accreditation Package is not required. 2.1 Fluidmesh System One damaged FM1200 at the pool house location will be replaced and optimized. The contractor will utilize Fluidmesh manufacturers guidelines when assessing the system. The guidelines to be followed include adding additional antennas, checking settings and alignment, replacing cabling or other components as needed for all existing devices. The contractor must supply their technicians with OSHA compliant safety equipment when working in or near roadways, or in elevated locations. 3.0 Evaluation Factors: Price, Assessment must be performed within 15-days ARO. Past Performance Experience- must provide contract number, point of contact, and description of satisfactory fluidmesh installation.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24522Q0603
  1. Combined Synopsis
  1. Combined SynopsisCurrentJun 22, 2022

    DJ10--Fluid Mesh Optimization Camera Assessment

    Notice b9066d07dca8416c8283fb10ed8294e7 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C24522Q0603

Archive Date

Jul 8, 2022

Office Address

LINTHICUM, MD, 21090