Notice ID: 0ce1dbbc1f67487abac23279750bb5b6Sources SoughtArchived
6530--BK Automated High Level Disinfecting Probe System RFI
Archived on November 10, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM EDT
- Posted
- October 21, 2025
- Notice type
- Sources Sought
- NAICS
- 339112: Surgical and Medical Instrument Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 245-NETWORK CONTRACT OFFICE 5 (36C245)
- Place of performance
- Department of Veterans Affairs VAMC Beckley, Beckley, West Virginia, 26801
- PSC
- 6530: HOSPITAL FURNITURE, EQUIPMENT, UTENSILS, AND SUPPLIES
- Last updated
- Nov 6, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24526Q0065
- Notice ID
- 0ce1dbbc1f67487abac23279750bb5b6
Description
Page 3 of 3 THIS REQUEST FOR INFORMATION IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. This is a Request for Information (RFI)/Sources Sought Notice (SS), this is not a Request for Quotes (RFQ) or Request for Proposals (RFP). No formal solicitation document exists at this present time. This is not a solicitation announcement. The purpose of this Sources Sought notice NAICS 339112 surgical manufacturing PSC 6530 surgical supplies NAIC size standard of 1000 employees for the Beckley VAMC. Responses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After reviewing the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SEWP, SAM.gov (SAM) or GSA ebuy. REQUESTED INFORMATION If you are interested and capable, and can provide the required supply, please provide the requested information for questions 1-12 as indicated below: Responses to this Sources Sought notice shall also include: Provide interested vendor company name, SAM UEI, address, point of contact. Provide interested vendor's business size status to include representations NAIC and PSC code? Does vendor have capability, product, and interest of an end item product listed in general information? Provide detailed responses to equipment general information listed below. Provide product end item info and price: product name/model/ model number/ product brochure/ specification sheet/warranty/life expectancy/solution/maintenance. Where is end item product place of manufacturer? Is interested vendor an authorized distributor of a domestic end item product? Is interested vendor a manufacturer of a domestic end item product? Is interested vendor a manufacturer of a nondomestic end item product? Is interested vendor an authorized distributor of a nondomestic end item product? If authorized distributor, what is manufacturer size? Provide an authorized distributor letter if vendor is not the manufacturer. SOW A. GENERAL INFORMATION High level disinfectant probe disinfector equipment requirement (yes/no/NA with details): Touchscreen operating panel- No rinse Automated system enclosed high-level disinfection of clean and dry probes - Minimized chemical use on equipment for HLD- chemical disinfection cycle time for 1 cleaned and dried probe - Automated digital cleaning cycle logging for streamlined tracking of log reports Temperature setting capable if solution required- Chemical disposal requirements- Small footprint- Accessories Printer- Accessories Paper- Power cord- 110 volts- Accessories Wall mounts- Accessories Positioner - Accessories Probe covers - Chemical cartridge/solution disposal requirement - Equipment life expectancy- If software is required provide software name, and VA OIT validation number- Provided preventive maintenance requirement & manual- May or may not require a LAN connection- Provide FDA approval number- NOTES All Capability Statements/Responses to this Sources Sought notice shall be submitted via ebuy Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted in response to this Sources Sought notice. Responses to this Sources Sought notice must be received no later than 10/31/25 at 12:00 p.m. (Eastern Standard Time). This Sources Sought notice is to assist the VA in determines sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced at a later date, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought notice. DISCLAIMER This Request for Information (RFI) is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(e), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI. End of Notice
Award Overview
Contacts
Contracting Officer
Primary Contact
Stephanie.henderson3@va.gov
Stephanie.henderson3@va.gov
Documents
Files (1)
- Download
36C24526Q0065.docx
18 KBAdded in Sources Sought version 3Posted
Lifecycle
- 3Version 3Sources SoughtArchivedCurrent
6530--BK Automated High Level Disinfecting Probe System RFI
Similar Opportunities
Additional Details
Solicitation Number
36C24526Q0065
Archive Date
Nov 10, 2025
Office Address
LINTHICUM, MD, 21090