GovChime
Notice ID: 66481f99f0ac4f2b99679e779d593dceSources SoughtArchived

6540--EYE CLINIC EXPANSION EQUIPMENT

Archived on March 7, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EST
Posted
January 21, 2026
Notice type
Sources Sought
NAICS
339115: Ophthalmic Goods Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Place of performance
LOUIS A JOHNSON VAMC 1 MED CENTER DR, Clarksburg, West Virginia, 26301
Last updated
Nov 4, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24526Q0241
Notice ID
66481f99f0ac4f2b99679e779d593dce

Description

This is a SOURCES SOUGHT NOTICE ANNOUCMENT ONLY It is neither a solicitation announcement nor a request for quote (RFQ) or request for proposal (RFP) and it does not obligate the Government to award a contract. The purpose of this Sources Sought Notice is to collect information on interest and capabilities within the market. The results of this notice will help identify a procurement strategy, including a small business set-aside, if appropriate, as well as help determine if items manufactured in the United States are available. This notice does not restrict the Government to an acquisition approach. All information submitted in response to this sources sought notice is voluntary. The Government will not pay for information requested or compensate any Contractor for any cost incurred in providing information to the Government. The Department of Veteran Affairs located at Louis A Johnson VAMC 1 Medical Center Drive, Clarksburg, WV 26301 is seeking the equipment below: Item # Description/Part Number Qty 1 CS0RLFX920L20BL - Reliance FX-920-L Exam Chair (#20 Pearl) with #301 Black Upholstery 5 2 CS0RL7900IC20FG - Reliance 7900 stand 4 3 CS1RL940 - Reliance 940 Chair Glide System 5 4 SL0HS900BQLEDU - Haag-Streit BQ 900 LED Slit Lamp (Unit Model) 4 5 TO0HS0016 - Haag-Streit BP/BQ/BX Applanation Tonometer 4 6 RE0RE11636 - Reichert 11636 Illuminated Phoroptor (-cyl, Black) 4 7 IO0KEVANPLWS - Keeler Vantage Plus LED Wireless Indirect with Slimline Charging System 4 8 CP0LOCVSE - Lombart CVS Essential Acuity System 4 9 ST0DTR1020BBL - Brewer New-Matic Stool with Backrest and Ring 4 Note: Items manufactured in the United States are strongly preferred. All equipment must be mutually compatible. Contractor shall provide two copies of the operating and service manuals. Cleaning/Sterilization Requirements. The Contractor shall provide cleaning/sterilization instructions (Instructions for Use IFU) for the Government to determine the ability of the facility to properly process the equipment. Delivery Requirements The period of performance is for one year from award of contract, with the potential to extend as needed. The delivery of the equipment will be arranged by the VA with the contractor at a future date in alignment with the completion of the current construction project. The estimated completion date of construction is September 2026. The contractor will be given a minimum of 90 days to deliver the equipment from the notice to deliver. Large deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place. Contractor is to provide the COR with shipment tracking information. Installation Requirements Full installation of the system shall be included as a part of this contract. All parts, materials, tools, labor, and travel to complete the installation shall be included as a part of this contract. Contractor is required to complete all configuration for the system to be usable. Contractor shall provide validation that the system is fully functional upon completion of the installation/implementation. Contractor Requirements All Contractor personnel performing installation services of the equipment shall have factory training and experience in the implementation of the equipment. Contractor shall provide copies of training certificates for the Contractor personnel performing work on-site upon the request of the Government. Warranty Information The equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment. Warranty support shall include repair of the system Warranty support shall include preventative maintenance of the system. Warranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance. Requests for warranty support shall be made to the telephone support number provided by the Contractor. Warranty support requests shall be responded to within 2 days. Contractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services. Service reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided. The NAICS code is: 339115 Ophthalmic Goods Manufacturing with a 1,000 employees size standard. The PSC is 6540 Ophthalmic Instruments, Equipment and Supplies. Interested contractors are invited to respond with the following information: Company name, address, telephone number, point of contact, and email address. Unique Entity Identifier (UEI) number issued by sam.gov. Business type: (Large, Small, Woman-Owned, VOSB/SDVOSB, etc.). If applicable, please identify your company's small business size standard and applicable NAICS code. Note: If claiming SDVOSB or VOSB, the firm must be verified in the Small Business Administration s Small Business Search at https://search.certifications.sba.gov. GSA contract number, if applicable. Summary, no longer than two pages, that describes ability to meet the Government s requirements. Include a statement identifying the Country of Origin for the equipment. If not the manufacturer, please include authorized distributor letter from manufacturer. Statement of Work Eye Clinic Expansion Equipment GENERAL: Scope of Services: The purpose of this requirement is to procure equipment for the activation of four (4) new exam rooms in the Eye Clinic at the Louis A. Johnson VA Medical Center. The procurement shall include chairs, stands, slit lamps, tonometers, ophthalmoscopes, refractors and full installation services. The timeline for installation will be dependent upon construction completion. Location: Louis A. Johnson VA Medical Center, 1 MEDICAL CENTER DRIVE CLARKSBURG, West Virginia 26301 Performance Period: The period of performance is for one year from award of contract, with the potential to extend as needed. The delivery of the equipment will be arranged by the VA with the awarded contractor at a future date in alignment with the completion of the current construction project. The estimated completion date of construction is September 2026. The contractor will be given a minimum of 90 days to deliver the equipment from the notice to deliver. WORK HOURS: Hours of Operation: Normal business hours are Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR). Delivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays. National Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination. On-Site Procedures Contractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department. Contractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information. Contractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure. Contractor personnel shall sign out upon completion of visit. Prior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired. The VA campus is non-smoking. Contractor personnel are required to comply with this policy. Parking. It is the responsibility of the Contractor to park in the appropriate desig nated park ing areas. Safety and Security Contractor shall follow all Occupational Safety and Health Administration (OSHA) laws and regulations. The Contractor is responsible for reporting any hazards they come across to their point of contact. Contractor shall follow all local procedures concerning infection control. Should the Contractor be unsure of the requirements, the COR can provide the specific information and procedures. See Section E for the Pre-Construction Risk Assessment (PCRA) requirements. See Section F for the Infection Control Risk Assessment (ICRA) requirements Contractor personnel shall wear visible identification at all times while on VA property. Contract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials. Property Damage The contractor shall take all necessary precautions to prevent damage to any Government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the Government, upon approval of the Contracting Officer. QUALITY ASSURANCE End-users, Biomedical Engineering, and/or the contract COR shall perform system verification tests to ensure the system is fully functional. Issues with the quality of the Contractor s work will be communicated through the Contracting Officer to the Contractor point of contact for resolution. Documentation with be completed in the Government systems. PRE-CONSTRUCTION RISK ASSESSMENT (PCRA) Eye Clinic Activity Location: Replacement of equipment in exam rooms. Mounting equipment may require drilling into the walls. Activity Name, Number, and/or Brief Description: Table 1 - Construction, Renovation, and/or Maintenance Activity Category NOTE: If any of the bulleted criteria in a higher activity category pertains to the work that will be done (even if the other criteria are in a lower category), use the higher activity category for the VHA ICRA. B Activity Category determined from Table 1 (A, B, C, or D): Category B General maintenance and repair work generally defined as follows: Prolonged inspection and work that may take longer than a single shift but not exceeding a week. Patients and employees are not to be in the area until activity is completed. Work that creates minimal dust and debris. Interior finish or surface repairs, updates, or modifications such as repair of firewalls and barriers, and new flooring that produces minimal dust and debris. Controlled sanding activities (e.g., wet or dry sanding) that produce minimal dust and debris. Plumbing work such as installation or replacement of a single fixture or piping for a single fixture. Any work on sanitary plumbing including snaking of drains. Electrical work such as installation of cabling/wiring/conduit for a single device, installation of new device such as a light fixture that produces minimal dust and debris. Air Handler and/or fan shutdown/startup and HVAC work such as replacement of a single diffuser, single terminal unit or a single device that produces minimal dust and debris. Table 2 - Affected Area Assessment Identify the areas and associated patients that will be affected by the construction/renovation/maintenance activity (see the Figure for a visual representation of adjacent affected areas). Figure: Isometric drawing of affected area assessment Area Service(s)/Type(s) of Area(s) (e.g., OR, Unit/Ward, Sterile Processing, Administrative, etc.)* Point of Contact (POC) POC Contact Information Activity Area** Eye Clinic Area Above Outside Area Below Electrical Room FMS Workroom Adjacent Area 1 Outside Adjacent Area 2 Outside Adjacent Area 3 Outside Adjacent Area 4 Corridor * There may be more than one Service/type of area for each row. List all. ** List the area(s) in which the construction/renovation/maintenance activity will occur. NOTE: When the Activity Category is B, C, or D, the control measures are determined by the Patient Risk in the adjacent affected areas. Table 3 - Patient Risk Category Using Table 3, identify the patient risk category for each area listed in Table 2. Of the patient risk categories identified, select the one with the greatest risk as the overall Patient Risk Category for the activity. High Overall Patient Risk Category determined from Table 3 (Low, Medium, High, or Highest): High Risk Patient care areas such as: Patient care rooms and areas, including spinal cord injury units All acute care units, including mental health All outpatient units and clinics Emergency department Community Living Centers, domiciliaries, and transitional residences Employee health Pharmacy general work zone Medication rooms and clean utility rooms Imaging suites diagnostic imaging Laboratory Table 4 - Level of Infection Prevention and Control Precautions Match the Overall Patient Risk Category (Low, Medium, High, Highest) determined from Table 3 with the planned Construction/Renovation/Maintenance Activity Category (A, B, C, D) from Table 1 to determine the minimum Level of Infection Prevention and Control Precautions (I, II, III, or IV) using Table 4 below. II Level of Precautions determined from Table 4 (I, II, III, or IV): Patient Risk Category Activity Category A B C D Low Risk I II II III Medium Risk I II III IV High Risk I II IV IV Highest Risk II III IV IV An infection prevention and control permit is required for Level III and Level IV. Consult with Infection Prevention and Control for Level I and Level II. Table 5 - Required Infection Prevention and Control Measures, by Level of Precautions Controls defined below for the Level of Precautions identified for the activity must be in place before the activity begins and maintained until work is completed and the area is activated. Control measures for each Precaution Level must also include the control measures in the preceding Level(s). As the activity progresses, a full re-evaluation of remaining activity type and patient risk is required prior to downgrading the Level of Precautions. Level of Precautions Control Measures Level I Perform work activity in a manner that does not create dust. Immediately replace any ceiling tile, close access panels, etc., upon completion of work. Any materials and equipment being brought into the facility must be free of contaminants and loose material. Level II All control measures in Level I and the following: Provide active means to control airborne dust from dispersing into occupied areas and/or water mist surface to control dust (e.g., Mobile Dust Containment Cart or some other system). Ensure worker clothing is clean and free of visible dust before leaving the work area. Remove or isolate air diffusers (supply and return) to protect the HVAC system from dust and reduce air turbulence. Rebalance system to address diffuser isolation. When the work involves or impacts potable water systems including stagnation due to reduced usage, the piping shall be flushed twice a week or isolated from the main system. Seal doors to prevent dust migration. Contain all trash and debris in the work area. Perform daily cleaning and disposal of trash (covered) from work area using an identified exit route. Any equipment, tools, or materials removed from the work area must be in sealed containers and/or cleaned of dust and debris prior to removal from the area. Nonporous/smooth and cleanable containers (with a hard lid) must be used to transport trash and debris from the construction areas. These containers must be damp-wiped cleaned and free of visible dust/debris before leaving the contained work area. Install a sticky (dust collection) mat at entrance of contained work area based on facility policy. Sticky mats must be changed routinely and when visibly soiled. Maintain clean surroundings when area is not contained by damp mopping or HEPA vacuuming surfaces at least daily. Table 6 - Minimum Infection Prevention and Control Measures Required Upon Completion of the Activity Controls defined below shall be completed upon completion of the activity and inspected prior to terminating measures defined in Table 5. Level of Precautions Measures Levels I - II Cleaning: Clean work areas including all environmental surfaces, high horizontal surfaces and flooring materials. Check all supply and return air registers for dust accumulation on upper surfaces as well as air diffuser surfaces. HVAC Systems: Remove isolation of HVAC system in areas where work is being performed. Verify that HVAC systems are clean and operational. Verify the HVAC systems meet original airflow and air exchange design specifications. Water systems: Until the potable water system is activated and in use, flushing shall continue at least twice per week in accordance with VHA Directive 1061. RECORDS MANAGEMENT OBLIGATIONS A.  Applicability This clause applies to all Contractors whose employees create, work with, or otherwise handle Federal records, as defined in Section B, regardless of the medium in which the record exists.  B.  Definitions Federal record as defined in 44 U.S.C. § 3301, includes all recorded information, regardless of form or characteristics, made or received by a Federal agency under Federal law or in connection with the transaction of public business and preserved or appropriate for preservation by that agency or its legitimate successor as evidence of the organization, functions, policies, decisions, procedures, operations, or other activities of the United States Government or because of the informational value of data in them.  The term Federal record: includes LAJVAMC records. does not include personal materials. applies to records created, received, or maintained by Contractors pursuant to their LAJVAMC contract. may include deliverables and documentation associated with deliverables. C.  Requirements Contractor shall comply with all applicable records management laws and regulations, as well as National Archives and Records Administration (NARA) records policies, including but not limited to the Federal Records Act (44 U.S.C. chs. 21, 29, 31, 33), NARA regulations at 36 CFR Chapter XII Subchapter B, and those policies associated with the safeguarding of records covered by the Privacy Act of 1974 (5 U.S.C. 552a). These policies include the preservation of all records, regardless of form or characteristics, mode of transmission, or state of completion. In accordance with 36 CFR 1222.32, all data created for Government use and delivered to, or falling under the legal control of, the Government are Federal records subject to the provisions of 44 U.S.C. chapters 21, 29, 31, and 33, the Freedom of Information Act (FOIA) (5 U.S.C. 552), as amended, and the Privacy Act of 1974 (5 U.S.C. 552a), as amended and must be managed and scheduled for disposition only as permitted by statute or regulation. In accordance with 36 CFR 1222.32, Contractor shall maintain all records created for Government use or created in the course of performing the contract and/or delivered to, or under the legal control of the Government and must be managed in accordance with Federal law. Electronic records and associated metadata must be accompanied by sufficient technical documentation to permit understanding and use of the records and data. LAJVAMC and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Records may not be removed from the legal custody of LAJVAMC or destroyed except for in accordance with the provisions of the agency records schedules and with the written concurrence of the Head of the Contracting Activity. Willful and unlawful destruction, damage or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. In the event of  any unlawful or accidental removal, defacing, alteration, or destruction of records, Contractor must report to LAJVAMC. The agency must report promptly to NARA in accordance with 36 CFR 1230. The Contractor shall immediately notify the appropriate Contracting Officer upon discovery of any inadvertent or unauthorized disclosures of information, data, documentary materials, records or equipment. Disclosure of non-public information is limited to authorized personnel with a need-to-know as described in the [contract vehicle]. The Contractor shall ensure that the appropriate personnel, administrative, technical, and physical safeguards are established to ensure the security and confidentiality of this information, data, documentary material, records and/or equipment is properly protected. The Contractor shall not remove material from Government facilities or systems, or facilities or systems operated or maintained on the Government s behalf, without the express written permission of the Head of the Contracting Activity. When information, data, documentary material, records and/or equipment is no longer required, it shall be returned to LAJVAMC control or the Contractor must hold it until otherwise directed. Items returned to the Government shall be hand carried, mailed, emailed, or securely electronically transmitted to the Contracting Officer or address prescribed in the [contract vehicle]. Destruction of records is EXPRESSLY PROHIBITED unless in accordance with Paragraph (4). The Contractor is required to obtain the Contracting Officer's approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under, or relating to, contracts. The Contractor (and any sub-contractor) is required to abide by Government and LAJVAMC guidance for protecting sensitive, proprietary information, classified, and controlled unclassified information. The Contractor shall only use Government IT equipment for purposes specifically tied to or authorized by the contract and in accordance with LAJVAMC policy. The Contractor shall not create or maintain any records containing any non-public LAJVAMC information that are not specifically tied to or authorized by the contract. The Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected from public disclosure by an exemption to the Freedom of Information Act. The LAJVAMC owns the rights to all data and records produced as part of this contract. All deliverables under the contract are the property of the U.S. Government for which LAJVAMC shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Any Contractor rights in the data or deliverables must be identified as required by FAR 52.227-11 through FAR 52.227-20. Training.  All Contractor employees assigned to this contract who create, work with, or otherwise handle records are required to take LAJVAMC-provided records management training. The Contractor is responsible for confirming training has been completed according to agency policies, including initial training and any annual or refresher training.Â

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Dec 31, 2026

NAICS

339115

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • 36C24526Q0241.docx

    118 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6540--EYE CLINIC EXPANSION EQUIPMENT

    Notice 66481f99f0ac4f2b99679e779d593dce on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
79%
AwardedOpen
Special Notice Special Notice Page 3 of 3 NOTICE OF THE INTENT TO SOLE SOURCE: This notice is prepared in accordance with Federal Acquisition Regulation (FAR) 5.101 Presolicitation Notice. This announcement constitutes the only notice and synopsis of the proposed action. The Department of Veterans Affairs (VA), Enterprise Procurement Office (EPO), on behalf of the Veterans Health Administration (VHA), Equipment Life Cycle Management (ELCM) Program intends to award Firm Fixed Price (FFP) sole source award in accordance with Federal Acquisition Regulation (FAR) 6.103-5 and Veterans Affairs Acquisition Regulation (VAAR) 819.7008 for the procurement Eye Lane or equal product and associated equipment with Corps Medical Supply LLC, 2211 N. Tradition Lane, Janesville, WI 53545. The applicable North American Industrial Classification System (NAICS) code 339112 Surgical and Medical Instrument Manufacturing is most appropriate for this requirement. The size standard is 1,000 employees The Product Service Code (PSC) is 6540 Ophthalmic Instruments, Equipment and Supplies. In accordance with Veterans Affairs Acquisition Regulation (VAAR) 819.7008, the determination to make a sole source award to a Service-Disabled Veteran Owned Small Business (SDVOSB) is a business decision wholly within the discretion of the Contracting officer; therefore, the requirement to ensure that offers are solicited from as many potential sources as practicable is not applicable to this procurement. In addition, 819.7008(c) further authorizes the Contracting Officer to make the award without first determining that only one SDVOSB source can meet the requirement. The statutory authority permitting other than full and open competition is 41 U.S.C. § 3304(a)(5), as implemented by the Federal Acquisition Regulation (FAR) 6.103-5 Authorized or required by statute. The applicable statute is Public Law 109-461: Veterans Benefits, Health Care, and Information Technology Act of 2006; specifically, the Veterans First Contracting Program outlined in 38 U.S.C. § 8127(c) and VAAR 819.7008. Interested parties may identify their interest and capability to respond to this requirement. Supporting information must be furnished in sufficient detail to demonstrate the ability to comply with the requirements. No solicitation package is available, and telephone requests will not be honored. Responses received will be reviewed; however, a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. No cost to the government will arise as a result of contractor submissions of responses to this announcement or the government use of such information. Eye Lane are multiple pieces of equipment/instruments needed to create complete eye examination lanes for expansion of eye care offered to Veterans, providing comprehensive eye exams to determine the health of the Veterans eyes. The following information regarding the needed equipment/instruments was modeled after multiple name brands. The equipment/instruments provided should be comparable to these name brands. Contract Line-Item Numbers (CLIN): Contract Line Items Manufacture Part Number Description 0001 Volk V20LC Volk 20D Large Aspheric Lens with Black Ring 0002 Volk V78C Volk 78D Small Aspheric Lens with Black Ring 0003 Volk V60C Volk 60D Small Aspheric Lens 0004 Volk V90C Volk 90D Small Aspheric Lens with Black Ring 0005 Good-Lite Company 730029 Ishihara 14 Plate Color Test Book 0006 Gulden 12121 Maddox Rod and Red lens occluder 0007 Stereo Optical SO-002 Stereo Randot Test (Standard) 0008 Marco TF0MA7060 Marco Metal Trial Lens Frame 0009 Marco TL0MA8408 Lombart full diameter trial lens set with minus cylinders in case 0010 Heine C-008.15.353 Heine BETA 200 LED Retinoscope Head (C-008.15.353) 0011 Heine C-002.17.080 Heine Finoff Transilluminator LED Head (C-002.17.080) 0012 Heine C-008.30.100 Heine BETA 200 LED Ophthalmoscope Head (C-008.30.100) 0013 Heine X-002.99.411 Heine BETA NT Handle for Instrument Stands (X-002.99.411) 0014 Gulden 11116 Gulden Horizontal Prism Bar 0015 Gulden 11117 Gulden Vertical Prism Bar 0016 Keeler 2215P1034 Amsler grid book 0017 Good-Lite Company 251000 Near Vision Card 0018 Good-Lite Company 700010 Lorgnette Pinhole Occluder 0019 Marco MIRL Front Surface Mirror Set 0020 Volk VBIRID Iridotomy Lens 0021 Volk VCAPS Capsulotomy Laser Lens 0022 Volk VMSLT Rapid SLT Lens 0023 Volk VSQUAD160 Super QuadR 160 PRP Laser Lens, with Flange 0024 Volk VSQUAD160NF Super QuadR 160 PRP Laser Lens, No Flange 0025 Volk VHRWF HR Wide Field PRP Laser Lens, with Flange 0026 Volk VAC Area CentralisR Lens, with Flange 0027 Volk VACNF Area CentralisR Lens, No flange 0028 Volk VG3 G-3 Gonio Lens 0029 Volk VG4LNF G-4 Mirror Gonio Lens 0030 Volk VG4HAN2 G-4 Mirror Gonio Lens, No Flange, 2-in-1 Handle 0031 Good-Lite Company 621100 Feinbloom Chart Low Vision Reading Chart 0032 Reichert 230650 Reichert AVIA Tonopen 0033 Marco EX0MAEX Marco Prism Exophthalmometer 0034 Visionix 8226-0015-02 Retinomax K+Screen handheld autorefractor/keratometer 0035 Volk VPRC Volk Pan Retinal 2.2 Lens with Black Ring 0036 Luneau Technology 12.20.84` Luneau Retinoscopy Rack 0037 Marco BAT-2000 Marco Brightness Acuity Tester 0038 Welch-Allyn 71670 Welch Allyn 3.5v NiCad Well Handle 0039 Stereo Optical SO015 Randot Stereo Test (Distance) 0040 Gulden 15115 C Daylight Glasses 0041 Gulden 11L22 S-22 Loose Prism Set 0042 Volk VSFNC Volk Superfield NC Lens 0043 Volk VDGTLWF Digital Widefield 90D Lens 0044 Stereo Optical SO-001 Stereo Fly Test 0045 Good-Lite Company 484025 Hand-held +/- .25 Jackson Cross Cylinder 0046 Good-Lite Company 484050 Hand-held +/- .50 Jackson Cross Cylinder 0047 Gulden 12136 Maddox Phoria Measure 0048 Good-Lite Company 494300 Red/Green Reversing Flipper 0049 Good-Lite Company 151170 Neutral Density Filter Bar The following details are applicable salient characteristics: SC # SALIENT CHARACTERISTICS Apply to CLIN # 1 Field of View: must be at least 46 degrees static / 60 degrees dynamic 0001 2 Image magnification must be at least 3X 0001 3 Must be non-contact design. 0001 4 Field of View: must be at least 81 degrees static / 97 degrees dynamic 0002 5 Image magnification must be at least 0.9X 0002 6 Laser Spot Magnification factor must be at least 1.08X 0002 7 Field of view: must be at least 68 degrees static/81 degrees dynamic 0003 8 Laser spot magnification must be at least 0.086x 0003 9 Image Magnification must be at least 1.1x 0003 10 Field of View: must be at least 74 degrees static / 89 degrees dynamic 0004 11 Image magnification must be at least 0.76X 0004 12 Laser Spot Magnification factor must be at least 1.32X 0004 13 Must consist of 14 pseudoisochromatic color plates arranged in a bound album/book format 0005 14 Must screen for red-green color vision deficiencies 0005 15 Must have standardized color reproduction 0005 16 Must include special diagnostic plates for determining the type and severity of color vision defect 0005 17 Must include administration and scoring instructions. 0005 18 Must be handheld instrument consisting of a full-eye occluder on one end and optical-quality red lens on the other end in a double-ended configuration 0006 19 Overall length shall be at least 24cm 0006 20 Reusable design must be smooth surface easily cleanable using routine clinical disinfecting procedures. 0006 21 Must measure stereopsis/depth perception. 0007 22 Must have stereoacuity range /= 400 arc sec 0007 23 Must use standardized scoring methodology. 0007 24 Must have PD adjustment range of 48-80mm minimum. 0008 25 Must be adjustable fit 0008 26 Must hold multiple lenses. 0008 27 Must be compatible with CLIN 0008 trial lens set 0008 28 Must have sphere range >/= +/-20D 0009 29 Must have cylinder range >/= +/-6D 0009 30 Increments must be /= 400 arc sec 0039 97 Must simulate daylight conditions for color vision testing 0040 98 Must contain 22 prism lenses 0041 99 Prism lenses must range from /= 40 diopters 0041 100 Must provide non-contact retinal examination for posterior segment evaluation 0042 101 Field of View must be >/= 95 degrees 0042 102 Must provide wide field of view suitable for examination of the posterior pole and mid-peripheral retina through a dilated pupil 0043 103 Must be compatible with standard slit lamps for non-contact retinal examination 0043 104 Must be high-resolution optical glass with anti-reflective coatings to minimize glare and maximize image clarity. 0043 105 Must provide measurable stereoacuity levels 0044 106 Must evaluate gross stereopsis and fine depth perception. 0044 107 Must be cross-cylinder power +/- 0.25D 0045 108 Must be handheld 0045 109 Must be cross-cylinder power +/- 0.50D 0046 110 Must be handheld 0046 111 Must permit measurement of horizontal and vertical phoria/anisophoria 0047 112 Must provide a prism measurement range of at lease 0-10 PD with a readable indication of effective prism power 0047 113 Must incorporate a red Maddox lens/rod assembly with an approximately 25mm aperture 0047 114 Must incorporate red and green optical filters in a reversing/flipper configuration that permits the red and green filters to be alternated between the right and left eyes 0048 115 Must provide sufficient red-green dissociation for clinical assessment of the binocular vision, suppression, or related visual function 0048 116 Must be handheld, reusable, and constructed of durable, cleanable materials suitable for repeated use. 0048 117 Must provide multiple neutral-density attenuation levels suitable for controlled reduction of transmitted illumination, with each density level permanently identified on the filter bar 0049 118 Filters must attenuate visible light uniformly across the intended operating wavelength range without materially altering the color or spectral characteristics of the transmitted light 0049 119 Filter elements must be optical-grade material 0049 THIS IS NOT A REQUEST FOR QUOTATION/PROPOSAL. THE GOVERNMENT IS NOT RESPONSIBLE FOR ANY COSTS ASSOCIATED WITH RESPONDING TO THIS NOTICE.
78%
Pre-Solicitation11/05/2026
Special Notice Special Notice Page 2 of 2 Page 1 of Special Notice *= Required Field Special Notice Page 1 of 2 Page 1 of 1 The Department of Veterans Affairs, Network Contracting Office (NCO) 6 intends to award a sole source award to Alcon Vision, LLC for customized surgical eye packs that will be delivered to Cumberland County VA Clinic, 7300 S. Raeford Rd., Fayetteville, NC 28304. It is in the Government s best interest to award the contract to Alcon Vision LLC to ensure that patients receive the optimum level of care for surgical eye procedures, such as cataract, glaucoma, and retinal procedures. Alcon Vision LLC is best suited to provide the supplies needed for these intricate eye surgeries, ensuring that patients receive an optimum level of care. This notice of intent is not a request for competitive quotes. No solicitation documents are available and telephone requests will not be accepted. However, any business that believes it can provide customized surgical eye packs may give written notice to Jo.Harris@va.gov by 08:00am EST on November 4, 2026. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Interested and capable respondents are requested to provide the information below. All responses to this notice shall include: company name, address, point of contact, phone number, System for Award (SAMs) Unique Entity Id Number, manufacturer authorization letter, authorized dealer, authorized distributor, or authorized reseller documentation. Responses will be considered by the Government; however, a determination by the Government not to compete the proposed acquisition based upon responses of this notice is solely within the discretion of the Government. NAICS Code 339113 Surgical Appliance & Supplies Manufacturing Size Standard 800 employees
75%
Special Notice11/04/2026
This will be a Firm Fixed Price requirement and for market research. DISCLAIMER This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought is that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought. Department of Veterans Affairs Veterans Health Administration (VHA) is publishing a Sources Sought Notice for the procurement of a Corneal Analyzer - OPD Scan III Visual System. This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. This Sources Sought is to facilitate the Contracting Officer a review of the market base, for acquisition planning, size determination, and procurement strategy. A solicitation will be posted at a later date. Please subject Title the email as follows: RFI 36C24W27Q0010 Corneal Analyzer - OPD Scan III Visual System General Requirements: Brand name or equal this analyzer is needed for the San Francisco VA Health Care System, San Francisco, CA 94121 in accordance with the following requirements and stated in the Statement of Work (SOW): The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment to the following listed above. Please provide the Place of Origin for Brand Name or Equal 52.211-6 Brand Name or Equal. As prescribed in 11.107(a), insert the following provision: Brand Name or Equal (Aug 1999) (a) If an item in this solicitation is identified as “brand name or equal,” the purchase description reflects the characteristics and level of quality that will satisfy the Government’s needs. The salient physical, functional, or performance characteristics that “equal” products must meet are specified in the solicitation. (b) To be considered for award, offers of “equal” products, including “equal” products of the brand name manufacturer, must- (1) Meet the salient physical, functional, or performance characteristic specified in this solicitation; (2) Clearly identify the item by- (i) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and (4) Clearly describe any modifications the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modifications. (c) The Contracting Officer will evaluate “equal” products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer. (d) Unless the offeror clearly indicates in its offer that the product being offered is an “equal” product, the offeror shall provide the brand name product referenced in the solicitation. (End of clause) VAAR 852.212-72 Gray Market Items: a) Gray market items are Original Equipment Manufacturers' (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical equipment only for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM, such that the OEM's warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. (End of clause) The Buy American Statute applies; Clause 52.225-1 Buy American – Supplies and Provision 52.225-2 Buy American Certificate will be included in the forthcoming solicitation. FAR 52.212-2 Evaluation-Commercial Items: A copy of the authorized distributor letter from the contractor to verify that you are an authorized distributor of the products/services SHALL BE SUBMITTED WITH THE QUOTE WITH THE SOLICITATION AND IS MANDATORY.
66%
Market Research11/03/2026
Page 1 of 1 IAW FAR 5.101 this notice is to advise the public that the Department of Veterans Affairs, Veterans Health Administration, Regional Procurement Office Central, Network Contracting Office (NCO) 23, for the Veterans Integrated Service Network (VISN 23), awarded a proposed contract action exceeding $25,000.00 for two (2) Ophthalmic chairs. Only one (1) responsible source IAW procedures prescribed in FAR 12.4. This notice is not a request for competitive quotes. The intended procurement will be classified under North American Industry Classification System Code (NAICS) 339115. For additional information regarding this action, please contact the above Point-of-Contact (POC).
66%
AwardedOpen

Additional Details

Solicitation Number

36C24526Q0241

Archive Date

Mar 7, 2026

Office Address

LINTHICUM, MD, 21090