GovChime
Notice ID: 9e60b516b39c4797812b843e5c0b84d4Combined Synopsis/Solicitation

F103--New Base + 4 Service Agreement for SPS RO_DI Water System REQUEST FOR QUOTE HUNTINGTON VAMC WV.

Archived on June 23, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM UTC+00:00
Posted
April 1, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
221310: Water Supply and Irrigation Systems
Agency
Department of Veterans Affairs

Notice details

Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Place of performance
Department of Veterans Affairs Huntington VAMC, Huntington, West Virginia, 21902
PSC
F103: ENVIRONMENTAL SYSTEMS PROTECTION- WATER QUALITY SUPPORT
Last updated
Aug 21, 2026

Identifiers

Solicitation number
36C24526Q0419
Notice ID
9e60b516b39c4797812b843e5c0b84d4

Description

A.1 INTRODUCTION The VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 has a requirement for a 5-year contract to perform preventative maintenance on the Reverse Osmosis/Deionizing System in Sterile Processing. A.2 BACKGROUND The VAMC has a need to have this work performed so this machine continues to perform properly and ensure bacteria does not grow within the system. A.3 SCOPE OF WORK Vendor will provide all parts, labor, equipment, material, and supervision to perform the work as listed below. STATEMENT OF WORK PART B WORK REQUIREMENTS B.1 Tasks to be accomplished: Perform Monthly Perform Preventive Maintenance Procedure (includes items such as checking system flow, chemistry, and pressure checks, maintaining the anti-scalant pump and solution tank, and updating the information tags with the most recent dates) Replace ChlorPlus Carbon Filter Cartridge, 1 Micron, 2-1/2" x 20" DOE (For Chloramines) install (2) monthly. Replace Filter Cartridge, 50 Micron prefilter/5 micro post filter (nominal), 4-1/2" x 20", Depth, Qty. 1(1) per month. Perform Quarterly DI Regeneration Certificate, Ultra Pure, 1/2 cu. ft. Replace (2) quarterly. Perform Annually Replace Filter Cartridges, Absolute Endotoxin, 0.2 Micron, 2-1/2" x 20", 222, Pall, total Quantity of 4 filters. Replace ultraviolet unit bulb (VIQUA Model#VP600M), Quantity 1 bulb. Replace Peracidin Disinfectant Concentrate, (4) 1 qt. Containers. Provide Residual Chlorine Test Strips, (6) Bottles of 100 Provide Renal Check, Residual Peroxide Test Strips (Low Level), (6) Bottles of 100 During the contract, the contractor shall support/resolve all issues with the RO/DI system to ensure and maintain passing test results required by VA Sterile Processing Department. Additionally, any RO/DI system mechanical issues will require prompt assistance in triage so that the vendor can notify VA personnel if the issue is out of contract scope. If the issue is out of scope, VA will work to have a credit card order placed from the quote provided or submit for another contract to complete required services with COR oversight.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

William Chris Galletta
Contracting Officer

Documents

Select documents to download

Showing 2 of 2 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationVETERANS AFFAIRS, DEPARTMENT OFApr 1, 202626.52 KB
Combined Synopsis/SolicitationVETERANS AFFAIRS, DEPARTMENT OFApr 1, 2026651.88 KB

Lifecycle

Solicitation:36C24526Q0419
  1. Combined Synopsis
  1. Combined SynopsisCurrentApr 1, 2026

    F103--New Base + 4 Service Agreement for SPS RO_DI Water System REQUEST FOR QUOTE HUNTINGTON VAMC WV.

    Notice 9e60b516b39c4797812b843e5c0b84d4 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C24526Q0419

Archive Date

Jun 23, 2026

Office Address

LINTHICUM, MD, 21090