GovChime
Archived

Z2AA - Renovate Historic Building 4

Overview

Response deadline
3:00 PM EST
Posted
June 16, 2025
Notice type
Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside

Notice details

Office
246-NETWORK CONTRACTING OFFICE 6 (36C246)
Place of performance
Fayetteville VAMC 2300 Ramsey Street Fayetteville, NC 28301, Fayetteville, 28301
Last updated
Nov 12, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24624R0030
Notice ID
097c9dee7b98423b9c830552ccccfc56

Description

This project consists of a complete renovation of the existing Historic Building 4 for administrative space and offices along with necessary support and utility requirements. This is designated as Mission Critical and must comply with VA Physical Security and Resiliency Design Manual (PSRDM) requirements for Mission Critical structures as incorporated in this design and the specifications. The project provides an addition for an elevator with access to all levels, and addresses life safety egress issues with the addition of code-compliant stairwells. Exterior renovations of the historical building will be renovated per National and State Historic Preservation Office (SHPO) requirements outlined in the specifications and drawings. The project will modernize the space with the most current level of technology and design including all new mechanical, plumbing, electrical, and fire protections systems. This design was created using Revit and Building Information Modeling (BIM) and all efforts post construction award shall be required to use Revit level of detail (LOD) 300 or higher. The Revit drawings will only be made available to the contractor awarded this project. This project does require asbestos and lead abatement. There are underground existing utilities and installations this contactor shall relocate. There is mobilization and project area located at the building, but pedestrian and vehicle traffic ways must be kept open for facility use. Any additional space required may be remote on the facility or the contractor shall have to find a location off station but will not be compensated by the VA. See specification section 01 35 26 Safety Requirements for detailed requirements of the Site Superintendent, SSHO, and Quality Control Manager. The contractor shall provide a mobilization plan along with all other required plans prior to being allowed on this station. MOB plan shall address all temporary utility measures, fence/gates, contractor parking, temporary signage/project signage, materials storage, dumpsters and any other details as requested by the VA COR.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Jan 14, 2027

NAICS

236220

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Documents

Files (65)

  • 36C24625C0027_1 Award Notice.docx

    22 KBAdded in Solicitation version 13Posted
    Download
  • 36C24624R0030 0006.pdf

    96 KBAdded in Solicitation version 11Posted
    Download
  • 230923 Direct-Digital Control System Connect to Existing N4.pdf

    172 KBAdded in Solicitation version 11Posted
    Download
  • 1_a G - Renovate Building 4 IFC page 1.pdf

    483 KBAdded in Solicitation version 10Posted
    Download
  • 1_a G - Renovate Building 4 IFC pages 2-3.pdf

    19 MBAdded in Solicitation version 10Posted
    Download
  • 1_a G - Renovate Building 4 IFC pages 4-6.pdf

    13 MBAdded in Solicitation version 10Posted
    Download
  • 1_a G - Renovate Building 4 IFC pages 7-10.pdf

    1.4 MBAdded in Solicitation version 10Posted
    Download
  • 1_b H - Renovate Building 4 IFC pages 12-14.pdf

    1.3 MBAdded in Solicitation version 10Posted
    Download
  • 2_C - L and S - Renovate Building 4 IFC pages 15-35.pdf

    17 MBAdded in Solicitation version 9Posted
    Download
  • 3_Arch - Renovate Building 4 IFC pages 36-85.pdf

    37 MBAdded in Solicitation version 9Posted
    Download
  • 4_FP and P - Renovate Building 4 IFC pages 86-109.pdf

    6.1 MBAdded in Solicitation version 9Posted
    Download
  • 5_Mech - Renovate Building 4 IFC pages 110-128.pdf

    5.9 MBAdded in Solicitation version 9Posted
    Download
  • 6_Elec - Renovate Building 4 IFC pages 129-155.pdf

    11 MBAdded in Solicitation version 9Posted
    Download
  • Specification Section 00 01 15 - LIST OF DRAWING SHEETS 01 21 25.pdf

    96 KBAdded in Solicitation version 9Posted
    Download
  • 36C24624R0030 0005.docx

    28 KBAdded in Solicitation version 9Posted
    Download
  • Drawings.zip

    5.2 MBAdded in Solicitation version 8Posted
    Download
  • 36C24624R0030 0004.docx

    26 KBAdded in Solicitation version 8Posted
    Download
  • 36C24624R0030 0003.docx

    122 KBAdded in Solicitation version 6Posted
    Download
  • Statement of Proposal Items - 0003.docx

    25 KBAdded in Solicitation version 6Posted
    Download
  • INSTRUCTIONS CONDITIONS AND OTHER STATEMENTS TO BIDDERS-OFFERORS .docx

    36 KBAdded in Solicitation version 6Posted
    Download
  • Proposal Item I Cost Breakdown.xlsx

    21 KBAdded in Solicitation version 6Posted
    Download
  • Proposal Item II Cost Breakdown.xlsx

    21 KBAdded in Solicitation version 6Posted
    Download
  • Proposal Item III Cost Breakdown.xlsx

    20 KBAdded in Solicitation version 6Posted
    Download
  • Proposal Item IV Cost Breakdown.xlsx

    20 KBAdded in Solicitation version 6Posted
    Download
  • Proposal Item V Cost Breakdown.xlsx

    21 KBAdded in Solicitation version 6Posted
    Download
  • Building 4 and 16 LBP Results.pdf

    6.8 MBAdded in Solicitation version 6Posted
    Download
  • Asbestos - Lead Paint Survey 12-31-2020.pdf

    5.5 MBAdded in Solicitation version 6Posted
    Download
  • Geotech Report_Fayetteville Bldg 4 Renovation.pdf

    3.9 MBAdded in Solicitation version 6Posted
    Download
  • Asbestos Reinspection Report - August 2019.pdf

    6.6 MBAdded in Solicitation version 6Posted
    Download
  • PL902 - PLUMBING DOMESTIC WATER ISOMETRICS.pdf

    319 KBAdded in Solicitation version 6Posted
    Download
  • Fayetteville - Temp Fence.pdf

    65 KBAdded in Solicitation version 6Posted
    Download
  • 230711 - HVAC AND BOILER PLANT INSULATION.pdf

    81 KBAdded in Solicitation version 6Posted
    Download
  • 230541 - NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT.pdf

    46 KBAdded in Solicitation version 6Posted
    Download
  • 230593 - TESTING ADJUSTING AND BALANCING FOR HVAC.pdf

    48 KBAdded in Solicitation version 6Posted
    Download
  • 238129 - VARIABLE REFRIGERANT FLOW HVAC SYSTEMS.pdf

    73 KBAdded in Solicitation version 6Posted
    Download
  • 230512 - GENERAL MOTOR REQUIREMENTS FOR HAVAC AND STEAM GENERATION EQUIPMENT.pdf

    54 KBAdded in Solicitation version 6Posted
    Download
  • 230511 - COMMON WORK RESULTS FOR HVAC.pdf

    128 KBAdded in Solicitation version 6Posted
    Download
  • 014529 - TESTING LABORATORY SERVICES.pdf

    126 KBAdded in Solicitation version 6Posted
    Download
  • 234000 - HVAC AIR CLEANING DEVICES.pdf

    36 KBAdded in Solicitation version 6Posted
    Download
  • 230923 - DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC.pdf

    173 KBAdded in Solicitation version 6Posted
    Download
  • 238143 - AIR SOURCE UNITARY HEAT PUMPS.pdf

    40 KBAdded in Solicitation version 6Posted
    Download
  • 232113 - Hydronic Piping.pdf

    43 KBAdded in Solicitation version 6Posted
    Download
  • 233400 - HVAC FANS.pdf

    32 KBAdded in Solicitation version 6Posted
    Download
  • 230800 - COMMISSIONING OF HVAC SYSTEMS.pdf

    28 KBAdded in Solicitation version 6Posted
    Download
  • 233100 - HVAC DUCTS AND CASINGS.pdf

    57 KBAdded in Solicitation version 6Posted
    Download
  • 238216 - AIR COILS.pdf

    26 KBAdded in Solicitation version 6Posted
    Download
  • 237200 - AIR TO AIR ENERGY RECOVERY EQUIPMENT.pdf

    30 KBAdded in Solicitation version 6Posted
    Download
  • 233700 - AIR OUTLETS AND INLETS.pdf

    27 KBAdded in Solicitation version 6Posted
    Download
  • 232300 - REFRIGERANT PIPING.pdf

    47 KBAdded in Solicitation version 6Posted
    Download
  • 238200 - CONVECTION HEATING AND COOLING UNITS.pdf

    27 KBAdded in Solicitation version 6Posted
    Download
  • 36C24624R0030 0002.docx

    27 KBAdded in Solicitation version 6Posted
    Download
  • 11-19-2024 Site Visit Attendance.pdf

    278 KBAdded in Solicitation version 6Posted
    Download
  • 36C24624R0030 0001.docx

    117 KBAdded in Solicitation version 6Posted
    Download
  • Statement of Work - Renovate Historic Building 4.pdf

    109 KBAdded in Solicitation version 6Posted
    Download
  • STRUCTRAL DRAWING SET.pdf

    2.7 MBAdded in Solicitation version 6Posted
    Download
  • PLUMBING DRAWING SET.pdf

    5.8 MBAdded in Solicitation version 6Posted
    Download
  • MECHANICAL DRAWING SET.pdf

    5.9 MBAdded in Solicitation version 6Posted
    Download
  • LANDSCAPE DRAWING SET.pdf

    1.0 MBAdded in Solicitation version 6Posted
    Download
  • FIRE PROTECTION DRAWING SET.pdf

    3.3 MBAdded in Solicitation version 6Posted
    Download
  • ELECTRICAL DRAWING SET.pdf

    20 MBAdded in Solicitation version 6Posted
    Download
  • CIVIL DRAWING SET.pdf

    16 MBAdded in Solicitation version 6Posted
    Download
  • ARCHITECTURAL DRAWING SET.pdf

    46 MBAdded in Solicitation version 6Posted
    Download
  • Specifications - Renovate Building 4 Issued For Construction.pdf

    12 MBAdded in Solicitation version 6Posted
    Download
  • Wage Determination.pdf

    172 KBAdded in Solicitation version 6Posted
    Download
  • 36C24624R0030_1.docx

    129 KBAdded in Solicitation version 6Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    Renovate Historic Building 4

    Notice 2d6577bb51e04db6ac524a8f59cc88f7 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 6dc9a58f3e0e4d69ba22d1d6d973a99e on SAM.gov

  3. 3
    Version 3SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice f99d952caa95481d9e10b0abf5f3b4e2 on SAM.gov

  4. 4
    Version 4SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice bc0cebc83b1d4ecf99e38da9826ede31 on SAM.gov

  5. 5
    Version 5SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice cdb3b6529e314c5d93abaf82e75d3c01 on SAM.gov

  6. 6
    Version 6SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 217c5ca069174d70b6df3c5ea4c2f1d5 on SAM.gov

  7. 7
    Version 7SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice c936b28056e14de1b1afcbc2b194bc45 on SAM.gov

  8. 8
    Version 8SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 3c1eb7cc1bf1483cb0eb92e4c962340b on SAM.gov

  9. 9
    Version 9SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 4f88f1402215479cbb57ad19c99fa6fc on SAM.gov

  10. 10
    Version 10SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 3ca3966b5de4436aa3bac88c5327da62 on SAM.gov

  11. 11
    Version 11SolicitationArchived

    Z2AA - Renovate Historic Building 4

    Notice 26a5a6cbf7964caa8dca32e8e9edf38b on SAM.gov

  12. 13
    Version 13SolicitationArchivedCurrent

    Z2AA - Renovate Historic Building 4

    Notice 097c9dee7b98423b9c830552ccccfc56 on SAM.gov

Other notices for this solicitation

  1. 3×
    Pre-SolicitationDec 23, 2023

    Z2AA-- Renovate Historic Building 4 Project No: 565-20-101

    Notice a1888c9baddb447f8489a3ceced5b1e7 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C24624R0030

Archive Date

Sep 12, 2025