GovChime
Notice ID: 7d64f877cb1d4b889c982fddaa4bc5ffSources SoughtArchived

W065--Tower and Scope Lease, Onsite Endoscopy Specialist, PM and Repair

Archived on May 10, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
6:00 PM EDT
Posted
April 17, 2026
Notice type
Sources Sought
NAICS
339113: Surgical Appliance and Supplies Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
246-NETWORK CONTRACTING OFFICE 6 (36C246)
Place of performance
Richmond VAMC 1201 Broad Rock Blvd, Richmond, Virginia, 23249
PSC
W065: LEASE OR RENTAL OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24626Q0530
Notice ID
7d64f877cb1d4b889c982fddaa4bc5ff

Description

This Sources Sought Notice is for the Richmond VAMC to determine sources for Tower and Scope Lease, Onsite Endoscopy Specialist, PM and Repair listed as the following: 9 or more units of - 4K/ICG/3D compatible Video Systems 2 or more units of - Video Mediastinascopes 2 or more units of - 4K/3D Exscope System 1 or more units of Service plan for the 13 units 2 units of Onsite specialist for the 13 or more units Salient Characteristics are as follows: System Functions & Performance Configuration & Integration: Supports multiple configuration options for various operating room (OR) layouts. Modular and expandable components for future upgrades. Integrates with VA IT systems (such as VistA or Cerner) and platforms like StreamConnect. Interfaces with a broad range of endoscopic and surgical devices. Scopes, cameras, and instruments are interchangeable and cross-compatible with tower and software. Stability & Ergonomics: Tower arms/supports stably hold up to 66 lbs. Multiple monitor/light mounting points. User interfaces/control panels accessible from standing position; operable with gloved hands. Ergonomic design to reduce staff fatigue. Lightweight cameras ( 350 grams). Cable Management: Integrated system minimizing visible cables to no more than two ( 2). Cables accessible for adjustments/repair within 5 minutes. Hygiene & Safety: Non-porous surfaces, cleanable/disinfectable per CDC/VA standards in under 5 minutes. Built-in locks or safety features to prevent accidental movement/dislodgement. Scopes and surgical instruments are fully compatible with autoclave sterilization (per VA Directive 1116). Imaging & Compatibility: Cameras support HD and 4K video output ( 3840×2160 resolution). Supports 3D/4K exoscopes for neurosurgery/ENT procedures. Camera Control Unit (CCU) backward/forward compatible with all VA camera heads/scopes. Supports rigid, flexible, exoscopic, and disposable scopes for airway, ENT, urology, and more. Imaging enhancement features: Dynamic brightness adjustment. Red contrast enhancement. Near-infrared (NIR) imaging with ICG fluorescence. Narrow-band imaging (NBI). True-color reproduction. Wide field of view. Integrated image/video recording. Secure, VA-compliant data transfer to VA IT platforms (encrypted wireless transfer if required). Durability: Instruments/scopes/accessories compatible with repeated autoclave sterilization. Service & Support On-site technical support (endoscopy specialist/technician) available during standard operating hours (minimally 7:00am 6:00pm). Telephone technical support available 24/7. On-site technician supports training, live troubleshooting, and rapid issue resolution. Replacement equipment (scopes, cameras, instruments) provided within 48 hours of notification. Initial and ongoing training for OR and clinical staff; in-service dates scheduled within 48 hours of request and delivered within seven days. Preventive and corrective maintenance performed by OEM-certified personnel per manufacturer s recommendations. Repairs documented and reported to VA Biomedical Engineering, including service reports/test data. Functionally equivalent loaner system/component provided within 48 hours of system failure. Updates, patching, and technology refreshes per OEM specification, at VA Biomedical Engineering s discretion. Compliance with VA infection control and patient privacy policies. Physical & Dimensional Requirements Designed for mounting to ceiling booms to maximize floor space. Carts/towers fit through standard VA doorways ( 36 wide). Supports all listed scopes/instruments within manufacturer s recommended weight/dimensions. Clinical Compatibility & Special Features Includes video mediastinoscope for thoracic surgery. Supports 4K/3D exoscope system(s) for ENT/neurosurgery. Cross-functional use: towers, cameras, and scopes are interchangeable for Urology, Gastroenterology, General Surgery, ENT, Thoracic Surgery, and selected Neurosurgery. Accessories & Future Upgrades Supports mounting/integration of additional VA-approved OR accessories and add-ons. Allows for future technology upgrades (hardware/software) during service agreement. Compliance & General Provisions All work compliant with VA, OSHA, and facility safety regulations. Equipment compatible with VA security/privacy requirements (HIPAA, VA Handbook 6500). Service staff trained/certified on relevant equipment. All warranty/service agreement terms clearly outlined in proposal/submission. ADDITIONAL INFORMATION: This is a SOURCES SOUGHT announcement only. The purpose of this notice is to conduct market research and obtain information from qualified businesses. This is not a request for bids, quotes, or proposals. All responsible sources must submit a capability statement addressing their capabilities, capacity, place of manufacture, and location which shall be considered by the agency.  This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.  Interested parties submitting a response to this inquiry must include the following information: Capability statement Name and address of company NAICS Code SAM.gov UEI number Business size (large, small, VOSB, or SDVOSB) Place of manufacture (if the requirement involves supplies) Identify applicable socioeconomic categories and any pertinent information which demonstrates the firm s ability to meet the above requirement An authorized distributor letter if the interested party is not the manufacturer  All responses shall be submitted no later than Sunday, 05/01/2026, by 06:00 PM EST. Responses shall be emailed to: Stephen.Nassan@va.gov. When replying, please include Sources Sought 36C24626Q0530 to ensure the email is reviewed in a timely manner.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Stephen Nassan
Contracting Specialist

Documents

Files (1)

  • 36C24626Q0530.docx

    19 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    W065--Tower and Scope Lease, Onsite Endoscopy Specialist, PM and Repair

    Notice 7d64f877cb1d4b889c982fddaa4bc5ff on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C24626Q0530

Archive Date

May 10, 2026

Office Address

HAMPTON, VA, 23667