GovChime
Notice ID: bd30e58817a5449892494f98eb11c6a3SolicitationArchived

6515--Lead Shield Containers

Archived on August 29, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
July 28, 2026
Notice type
Solicitation
NAICS
339113: Surgical Appliance and Supplies Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
246-NETWORK CONTRACTING OFFICE 6 (36C246)
Place of performance
DURHAM VAMC 508 Fulton ST, Durham, North Carolina, 27705
PSC
6515: MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24626Q0804
Notice ID
bd30e58817a5449892494f98eb11c6a3

Description

?.## PERFORMANCE WORK STATEMENT (PWS) GENERAL: Building 42, 508 Fulton Street, Durham, NC 27705, has a requirement for radiation shielding equipment. The radiation shielding equipment is necessary for clinicians to provide patients care. BACKGROUND: Building 42 has a requirement for radiation shielding equipment. PURPOSE: The radiation shielding equipment is required for the protection of employees from high-energy radionuclides during the receiving and preparation of unit doses for patients. and is critical for the safe handling of radioactive materials. This equipment is essential for maintaining safety protocols and compliance with radiation protection standards and is crucial for patient care at Building 42, Radiation Oncology. SCOPE: Building 42 is requesting contractors to provide brand name or equal equipment that meets or exceeds the physical, functional, and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the Hot Lab. PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: PET Unit Dose Cabinet (244-205) Minimum 0.25-inch lead equivalency Lockable and shielded storage Radiation warning labeling Smooth, non-porous, cleanable surfaces Dose storage compartments Recessed dose calibrator shield Sliding shelves Shielded on all six sides for radiation protection Key-locked doors for secure storage Stainless steel countertop includes 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Dimensions: 36.5" w x 24" depth x 36.5" h Lead Shielding: 0.25" (0.64 cm) Finish: Powder coat Doors: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) lip Countertop Height: 36.5" (92.7 cm) Weight Capacity: 1,550 lb (703 kg) Weight: 1,240 lb (562 kg) Quantity: 1 PET Shielded Sharps Container System (5730-2271) Outer container with 1-inch lead shielding Removable inner sharps container Biohazard and radiation labeling Stable, tip-resistant design Hinged cover Sliding top with lock Dimensions: 13.5625" h x 10.625" od x 6.125 id (34.4 x 27 x 15.6 cm) Weight: 160 lbs. (72.6 kg) Lead Lining: 1" (2.5 cm) Quantity: 1 Sharps Inserts (0660-0042) Compatible with PET Sharps Container Shield (5730-2271) Quantity: 1 pkg (total 12) L-Block Shield, Compact, 1.5 lead with built-in Dose Calibrator Shield (042-433) 1.5 thick lead shielding in front, 1 in base 8 x 8 x 4 adjustable lead glass window 0.86" thick lead shield surrounds calibration chamber for a total of 1" of lead shielding Quantity: 1 Interlocking Lead Brick Cave (042-434) Three-sided configuration 2-inch thick lead bricks Modular/interlocking system Flat working surface Dimensions: I.D.: 14 w x 20.5 depth x 16 h (35 x 52.1 x 40.6 cm) Lead Shielding: 2 thick (5 cm) Finish: Paint Weight: 597 lb (271 kg) Quantity: 1 Cabinet, Decay & Storage (244-162) 1-inch lead shielding Lockable cabinet Waste segregation capability Radiation labeling Supports storage and decay workflows in one unit Removable drawers Two adjustable decay shelves for storage Key-locked doors and drawers for controlled access Stainless steel countertop which includes a 4" (10.2 cm) backsplash and a 0.5" (1.3 cm) spill-proof lip Quantity: 2 Cabinet, Preparation Enclosure Base (244-192) 1-inch lead shielding Stainless steel or non-porous construction Spill-resistant Compatible with radiopharmacy enclosures Full-height double doors with locking hardware Adjustable internal shelf Dimensions: 36.5" w x 24" depth x 36.0" h (92.7 x 61 x 91.4 cm) Lead Shielding: 0.25 thick on all six sides Shelf Dimensions: 30" w x 18" depth (76.2 x 45.72 cm), 100 lb (45.4 kg) capacity, adjustable height Doors: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Countertop Height: 36.5" (92.7 cm) Finish: Powder coat Weight: : 2433 lb (1104 kg) Quantity: 1 Cabinet, Sink and Waste (244-222) Dimensions: 36.5" w x 24" depth x 36.0" h (92.7 x 61 x 91.4 cm) Lead Shielding: 1" (2.54 cm) Door and Drawers: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Countertop Height: 36.5" (92.7 cm) Faucet: Hands-free operation Electronic faucet with mixer to adjust temperature Below deck battery pack requires six 1.5V batteries (included) Finish: Powder coat Weight: 942 lb (429 kg) Quantity: 1 FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed in section above. SOFTWARE: N/A INSTALLATION AND TRAINING: The Contractor shall provide all management, tools, parts, materials (including quality control materials, and consumable items), equipment, travel, and labor necessary to provide and install all equipment described above. Contractor shall provide instructions and training to the end user. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered after receipt of purchase order not earlier than 08/01/26 but not later than 09/30/2026. PLACE OF DELIVERY: Durham VA Building 52, 508 Fulton Street, Durham, NC 27705 between the hours 0800-1600. Delivery during any holiday will not be accepted.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Ricardo P McIntosh
Contract Specialist

Documents

Files (2)

  • 36C24626Q0804 0001.docx

    30 KBAdded in Solicitation version 3Posted
    Download
  • 36C24626Q0804_1.docx

    97 KBAdded in Solicitation version 2Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    6515--Lead Shield Containers

    Notice 6d2206e72a9544f788c8d073e0f6357b on SAM.gov

  2. 3
    Version 3SolicitationArchivedCurrent

    6515--Lead Shield Containers

    Notice bd30e58817a5449892494f98eb11c6a3 on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeJul 27, 2026

    6515--Lead Shield Containers

    Notice fd77fde90a084ee28024631898ae4852 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C24626Q0804

Archive Date

Aug 29, 2026

Office Address

HAMPTON, VA, 23667