GovChime
Notice ID: c9a71b64901847bc990b8b72dbab14a1Special NoticeArchived

J039--Metasys Annual Building Automation System (BAS) Service Agreement

Archived on October 4, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
8:00 AM EDT
Posted
September 1, 2026
Notice type
Special Notice
NAICS
561210: Facilities Support Services
Agency
Department of Veterans Affairs

Notice details

Office
246-NETWORK CONTRACTING OFFICE 6 (36C246)
Place of performance
The Central Virginia VA Health Care System Department of Veterans Affairs, Richmond, VA, 23249
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24626Q0976
Notice ID
c9a71b64901847bc990b8b72dbab14a1

Description

The Department of Veterans Affairs, Network Contracting Office (NCO 06), hereby provides notice of its intent so award a sole source contract with Johnson Controls Inc., specifically for the Metasys Annual Building Automation System (BAS) Service Agreement in support of the Central Virginia VA Health Care System, located at 1201 Broad Rock Blvd, Richmond, VA 23249. This preventative maintenance service agreement is to support a period of performance for a base plus two option years. Justification for this sole source procurement is in accordance with 41 U.S.C. 1901, implemented by FAR 12.102 ("Restricting Competition") and FAR Table 12 1 authority citations, based on a only one responsible source rationale. Competition is restricted due to the proprietary nature of the Metasys system and the OEM s exclusive ability to provide the required maintenance, upgrades, cybersecurity patches, and system-level support. The Richmond VA Medical Center operates a Metasys Building Automation System, a proprietary Johnson Controls platform that centrally monitors and controls HVAC and environmental systems. As documented in government market research, Metasys BAS is a proprietary, multilayered automation system requiring certified Metasys technicians with authorized access to firmware, databases, graphics, proprietary components, and system-level programming. Johnson Controls is the Original Equipment Manufacturer (OEM) and the only vendor with full legal, technical, and cybersecurity authority to perform the required services, updates, and system modifications. Market research confirms that no other small business, SDVOSB/VOSB, or commercial provider can fulfill the full scope of proprietary Metasys BAS requirements. The anticipated services include monthly BAS support, system inspection, calibration, network security updates, database backups, alarm review, emergency on call support, and minor repair materials all of which require OEM authorized access and certified Metasys-specific technical expertise. Description: Metasys Annual Building Automation System (BAS) Service Agreement All responses must be submitted by email to: Tiara.White@va.gov The subject line of the email must include: 36C24626Q0976_1 Metasys Annual Building Automation System (BAS) Service Agreement. This notice of intent is not a request for competitive quotes. No solicitation documents are available. However, interested parties who believe they can meet the requirements may submit a capability statement that demonstrates OEM authorization and full Metasys BAS privileged-access capability and possesses relevant past experience, and expertise may give written notice. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Responses will be considered by the Government, however, a determination by the Government not to complete the proposed acquisition based upon responses to this notice is solely within the discretion of the Government. No telephone request will be accepted. Responses received on or by 8:00 am est on September 4, 2026, EST will be considered by the Government. Inquiries shall be emailed to Tiara.White@va.gov. No telephone request will be accepted.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Feb 28, 2027

NAICS

561210

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Tiara White
Contracting Officer

Documents

Files (2)

  • 36C24626Q0976_1.docx

    25 KBAdded in Special Notice version 6Posted
    Download
  • 36C24626Q0976.docx

    28 KBAdded in Sources Sought version 4Posted
    Download

Lifecycle

  1. 4
    Version 4Sources SoughtArchived

    J039--Annual HVAC Building Automation System (BAS) Service Agreement

    Notice dbc36524fe9c4d13b62eebbdf4a8bf8f on SAM.gov

  2. 6
    Version 6Special NoticeArchivedCurrent

    Type changed from Sources Sought to Special Notice

    J039--Metasys Annual Building Automation System (BAS) Service Agreement

    Notice c9a71b64901847bc990b8b72dbab14a1 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT Description The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 21, intends to award a sole source contract to Johnson Controls, Inc. for maintenance, support, inspection, testing, monitoring, programming, repair, and related services for the Metasys Building Management System (BMS) located throughout the Northern California Health Care System. The proposed contract will consist of: One (1) twelve-month base period Four (4) one-year option periods The anticipated start date: February 01, 2027 Sole Source Rationale The Metasys Building Management System is a proprietary platform developed and maintained by Johnson Controls, Inc. The system integrates critical facility operations including heating, ventilation, air conditioning (HVAC), environmental controls, alarms, and energy management functions essential to patient care and facility operations. Based on market research conducted by the Government, Johnson Controls has represented that it is the only authorized source capable of providing the required proprietary software support, system programming, firmware updates, technical services, and manufacturer-certified maintenance for the installed Metasys system within the Northern California Health Care System. Johnson Controls provided documentation supporting its sole-source position. Award to any source other than Johnson Controls could result in incompatibility with existing equipment, loss of manufacturer support, increased operational risk, and potential disruption to critical building management functions. Authority This procurement is being conducted under the authority of RFO 12.201(a) or RFO 6.103-1(b), Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements, as applicable. Submission of Capability Statements This notice is not a request for competitive quotations or proposals. However, interested parties that believe they can satisfy the requirement may submit a capability statement demonstrating their ability to provide the required proprietary Metasys Building Management System services without limitation and with full manufacturer authorization. Capability statements must be received no later than November 03, 2026, 10AM PST. Responses shall be submitted electronically to: James Postell Contracting Officer Department of Veterans Affairs Email: James.Postell@va.gov Disclaimer This notice is for informational purposes only and does not constitute a solicitation. The Government does not intend to pay for any information submitted in response to this notice. Responses will be evaluated solely to determine whether competitive procurement is feasible.
71%
Special Notice11/03/2026
What are the hours of operation for Generator Maintenance? This is in the SOW Can you provide a Document with each Back-up Generator Model # s &Serial # s? This is Attachment A of the package Please Confirm the Voltage of the Generators? 480 and 240 Regarding Contractor Provided Consumables, many of the items listed are typically repairs quoted and approved before work proceeds on this and some parts(hoses and belts). As an outside vendor there is no way to effectively build this into your maintenance plan to guarantee effective cost for both the vendor and for Edward Hines VA. We request this section is altered to allow for these costs to be sectioned out for repairs and for one annual service to replace filters and oil. See Attachment B. How many Generators have Diesel Engines? All of them Are there any Generators with difficulty accessing (Roof, Parking Garage, Basement)? If so, which units are they? NO Are your Generators within 50 ft of the Entry Door, where our truck will be parked? Yes Are the Annual Load Tests performed with your Minor B-PMs? No Can I get the age of each equipment if possible? See Attachment A Please clarify the Unscheduled Repair CLIN amount. Is the stated $50,000 intended to mean $50,000 per contract year? This is just a funding item for me to populate an unscheduled maintenance clin for me to address items the break. Where should emergency travel and labor be priced? All previous contracts has local labor. Never had this issue. Build it in your quote. Will VA furnish diesel consumed during inspections? VA furnishes Fuel for the generators Period. Can you provide any previous maintenance reports, emergency calls, major repairs, etc.? After Award. Consumables Attachment Section 2.1 states Replace PM Consumables as required and references Attachment 1, while the solicitation package includes Generator Consumables Attachment B. Please confirm that Attachment B is the document intended by the reference to Attachment 1, and that the consumables identified in Attachment B are to be furnished and replaced by the contractor as required during preventive maintenance and included within the applicable PM CLIN pricing. Consumables are outlined in Attachment B. Work Hours / Load Bank Testing Section 4.3 identifies the monthly PM for the two 600 kW generators and one 500 kW generator as occurring on the second Tuesday of each month from 4:00 AM to 7:00 AM, while the 1250 kW and 750 kW generators may be serviced during normal business hours. Please confirm whether the annual load-bank testing, ATS maintenance, sampling, and other annual maintenance activities may also be performed during normal business hours unless otherwise coordinated with the COR. The 600 s, and 500 are backing up a critical production line that is old and has issues during power transfers. We require them and their associated equipment to be cycled or maintained prior to that department s workday start, so they can start the production line on time with no delay. This department is the Consolidated Mail Order Pharmacy (CMOP). All the generator maintenance is to be performed on the second Tuesday of each month, we need the CMOP Generators started and done first. Transformer Annual Inspection and IR Scan The scope includes quarterly energized transformer inspections as well as an annual inspection that includes additional maintenance activities and an IR scan. The pricing schedule only provides a quarterly transformer CLIN with a quantity of four. Please confirm whether the annual transformer inspection and IR scan are to be included within the pricing for the four quarterly inspections, with one quarterly service incorporating the annual work, or if the annual service is to be priced separately. Please confirm the intended operating condition for the annual IR scan, as it appears under the annual de-energized inspection section. Annual Transformer and ATS IR Scanning Procedure The annual infrared (IR) scan of transformer lugs and automatic transfer switches (ATSs) is to be completed while the equipment is energized, prior to any deenergizing procedures. This approach allows for the identification of potential faults under operating conditions, ensuring that any issues are detected before maintenance begins. Once the IR scan is performed, any necessary repairs should be made during the scheduled deenergized maintenance period. This ensures that faults identified during the scan can be addressed safely while the equipment is not under load. The IR scan should occur once each year and, whenever possible, should be scheduled close to the time of the annual deenergized maintenance. This coordination facilitates efficient fault resolution and minimizes downtime. In the event of an emergent issue identified during the scan, immediate corrective action will be taken to address the problem as soon as possible, regardless of the scheduled maintenance cycle.
61%
Combined Synopsis10/19/2026
60%
AwardedOpen
NOTICE OF INTENT TO SOLE SOURCE The Department of Veteran Affairs, Veterans Health Administration, Network Contracting Office 21 (NCO21), 6900 North Pecos Road, North Las Vegas, NV 89086, intends to negotiate a sole source Firm-Fixed Price, base plus 4 option year (OY) contract for water monitoring, maintenance and repair service by Phigenics LLC. at VA Sierra Nevada Healthcare System (VASNHCS). The Original Equipment Manufacturer (OEM) is Phigenics and they are the sole proprietor for its patented tests and phi Analytics (web-based data management system) to include the process we use for developing and operating Water Management Programs within the phi Analytics framework. Phigenics is also the sole proprietor/Original Equipment Manufacturer (OEM) for the Potable Water Analytics (PWA), Cooling Tower Water Analytics (CTWA) and Sterile Processing Water Analytics (SPWA) equipment systems, to include associated services. The government intends to award the contract on 11/6/2026 to Phigenics LLC, 3S701 West Avenue, Suite 100, Warrenville, IL 60555. UEI: Z1VZG6JVDRQ5 CAGE CODE: 5SF88. The Period of Performance will be 12/21/2026-11/30/2031. This synopsis announcement is being issued for information purposes only and does not constitute a solicitation or request for competitive proposals. If a firm believes it is capable of meeting the Government's requirement and provides an authorized letter to perform services on the equipment., it may identify their interest and capability to the Contracting Officer within five (5) calendar days of this publication by contacting John Waldrip via email at john.waldrip@va.gov. Telephone inquiries will not be accepted. Those interested firms must indicate whether they are large, small, small-disadvantaged, 8(a) or woman owned business and whether they are U.S. or foreign owned. Respondents who submit proprietary data shall clearly mark the data with appropriate markings. The Government will not pay for any information submitted as a result of this synopsis. This synopsis shall not be construed as an obligation on the part of the Government to acquire any products or services. Responses are due no later than Monday, November 9, 2026, at 10:00AM Pacific Standard Time.
59%
Special Notice11/09/2026
NOTICE OF INTENT TO SOLE SOURCE The Department of Veteran Affairs, Veterans Health Administration, Network Contracting Office 21 (NCO21), 6900 North Pecos Road, North Las Vegas, NV 89086, intends to negotiate a sole source Firm-Fixed Price, base plus 4 option year (OY) contract for water monitoring, maintenance and repair service by Phigenics LLC. at VA Sierra Nevada Healthcare System (VASNHCS). The Original Equipment Manufacturer (OEM) is Phigenics and they are the sole proprietor for its patented tests and phi Analytics (web-based data management system) to include the process we use for developing and operating Water Management Programs within the phi Analytics framework. Phigenics is also the sole proprietor/Original Equipment Manufacturer (OEM) for the Potable Water Analytics (PWA), Cooling Tower Water Analytics (CTWA) and Sterile Processing Water Analytics (SPWA) equipment systems, to include associated services. The government intends to award the contract on 11/6/2026 to Phigenics LLC, 3S701 West Avenue, Suite 100, Warrenville, IL 60555. UEI: Z1VZG6JVDRQ5 CAGE CODE: 5SF88. The Period of Performance will be 12/21/2026-11/30/2031. This synopsis announcement is being issued for information purposes only and does not constitute a solicitation or request for competitive proposals. If a firm believes it is capable of meeting the Government's requirement and provides an authorized letter to perform services on the equipment., it may identify their interest and capability to the Contracting Officer within five (5) calendar days of this publication by contacting John Waldrip via email at john.waldrip@va.gov. Telephone inquiries will not be accepted. Those interested firms must indicate whether they are large, small, small-disadvantaged, 8(a) or woman owned business and whether they are U.S. or foreign owned. Respondents who submit proprietary data shall clearly mark the data with appropriate markings. The Government will not pay for any information submitted as a result of this synopsis. This synopsis shall not be construed as an obligation on the part of the Government to acquire any products or services. Responses are due no later than Monday, November 9, 2026, at 10:00AM Pacific Standard Time.
59%
Special Notice11/09/2026

Additional Details

Solicitation Number

36C24626Q0976

Archive Date

Oct 4, 2026

Office Address