Notice ID: 3ceaab69f8fe4272a0f5c6915f76a1b0Presolicitation
C223--PROJECT TITLE/NUMBER: NRM A/E Design - Project # 508-21-107 - HEPA Filter Installation Pharmacy Cleanroom
Archived on January 28, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM UTC−05:00
- Posted
- November 13, 2020
- Notice type
- Presolicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541330: Engineering Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247)
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24721R0012
- Notice ID
- 3ceaab69f8fe4272a0f5c6915f76a1b0
Description
HEPA Filter Installation Pharmacy Cleanroom
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24721R0012- Pre-Solicitation
Formal solicitation typically follows within 30–60 days. (estimate)
- 2×Pre-SolicitationCurrentNov 12, 2020
C223--PROJECT TITLE/NUMBER: NRM A/E Design - Project # 508-21-107 - HEPA Filter Installation Pharmacy Cleanroom
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Modification 2 to Presolicitation Notice 36C25527R0013 This modification provides answers to RFIs received and revised the evaluation criteria to be used for this project. RFIs Received for Project # 657A5-24-108, Replace Medium Voltage Feeder 3 and Transformers 1. Factor 4 Past Performance / Section F Project Eligibility  The solicitation states that projects submitted for past performance consideration must have completed both design and construction, and that projects not constructed will not be considered. Would the VA consider accepting relevant electrical infrastructure studies or assessments in Section F, particularly those involving medium-voltage distribution systems and feeder evaluations, that demonstrate directly applicable technical expertise but did not result in construction? We prefer to keep it as projects that were designed AND constructed. Since this is a construction project and not a study, we want projects that have been finished to be used for past performance criteria.  2. Factor 2 Specialized Experience and Technical Competence / Laboratory Requirements  Factor 2 references the firm's technical capabilities in design quality management procedures, CADD/BIM, equipment resources, and laboratory requirements. Given that the project scope primarily involves medium-voltage electrical feeder and transformer replacements, could the VA clarify the applicability of laboratory requirements to this project? We respectfully request that this criterion be removed from the evaluation requirements, as it does not appear directly relevant to the stated scope of work. Laboratory requirements were deleted. Please see revised evaluation criteria below.  3. Request for Submission Deadline Extension Given the technical scope of the project and the level of detail required to address the evaluation criteria, we respectfully request a one-week extension of the SF330 submission deadline, from November 10, 2026, to November 17, 2026. This additional time would allow interested firms to prepare comprehensive qualifications packages that fully address the solicitation requirements. SF330 submission due date extended from 11/10/2026 to 11/172026. End of RFIs. | 67% | Pre-Solicitation | 11/17/2026 |
DESCRIPTION Project: 589-27-108 Solicitation Number: 36C25527Q0057 RFP: 36C25527R0018 Title: Correct Electrical Deficiencies in Bldg. 26 Contracting Office: Network Contracting Office 15 Contracting Office Location: 3450 S 4th Street Traffic way, Leavenworth, Kansas Type of Notice: Sources Sought Posted Date:11/16/2026 Response Date: 12/1/2026 at 2:00 PM Central Time Set Aside: Service-Disabled Veteran Owned Small Business Classification Code: C222 -Architect and Engineering- Electrical Systems NAICS Code: 541330 Engineering Services Synopsis: Please note that this is NOT a request for SF330's or proposals, the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. The Department of Veterans Affairs Network Contracting Office (NCO) 15, is conducting a market survey for qualified: Service-Disabled Veteran Owned Small Businesses (SDVOSB), capable of providing the required services outlined below for the VA Medical Center located in Kansas City, Missouri. The applicable NAICS code is 541330 Engineering Services and the size standard is $25.5 Million. Responses to this notice must be submitted via e-mail to matthew.finley@va.gov and received no later than December 1, 2026 at 2:00 PM Central Time. No telephone inquiries will be accepted or returned. Additional information about this project will be issued on the Federal Business Opportunities website https://www.fbo.gov once available. Period of Performance for all design work is 150 calendar days including time for VA reviews. Prospective SDVOSB firms are reminded that in accordance with VA Acquisition Regulation (VAAR) 852.219-75, the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73. The prime architect shall provide written certification of this to the Contracting Officer with the response provided for this market research. GENERAL SCOPE OF DESIGN: The Architect/Engineer (A/E)) shall provide professional design services for a complete, coordinated, constructible, and independently usable project to correct electrical closets, secondary distribution, uninterruptible power, and emergency power deficiencies in Building 26 at the Kansas City VA Medical Center (KCVA), 4801 Linwood Blvd, Kansas City, MO 64128. A/E Part One Services (also known as the design phase) for this design project encompass site visits as needed, field investigations, and the conduct of studies and user interviews to prepare detailed drawings, specifications, and cost estimates. This effort covers all facets of work and disciplines/trades to facilitate and provide construction period services for a construction project. This effort covers all facets of work and disciplines/trades to facilitate a complete, coordinated, constructible, and independently usable project to correct electrical closets, secondary distribution, and emergency power deficiencies in Building 26 at the Kansas City VA Medical Center. The A/E services are required for preparation of Narrative, Studies, Phasing Design, Schematic Designs, Design Development, Construction Documents, and As Built Documents. The A/E shall coordinate all disciplines necessary to deliver a complete electrical infrastructure project. The A/E shall not rely solely on record drawings and shall verify existing conditions before using them as the basis of design. Ensuring all required permits and licenses from federal, state/provincial, or local authorities are obtained for the construction, installation, and operation of the equipment is also part of the A/E s responsibilities. The project design will comply with Infection Control and Interim Life Safety Measures. The A/E will provide design drawing, specification, and IGCE submissions at 35% (Schematic Design), 65% (Design Development), 95% (Construction Documents), and Final Bid Documents for all disciplines necessary to complete the project to the VA. END OF SCOPE OF WORK Interested firms must be registered in https://sam.gov with NAICS code 541330 and qualified as a Service-Disabled Veteran Owned small business under NAICS code 541330. Qualified service-disabled veteran owned small businesses are encouraged to respond and required to be registered in with the Small Business Administration (SBA) registry https://veterans.certify.sba.gov on or before the response date. If interested in this opportunity, please provide Capability Statement via email. The Capability Statement is designed to inform the Department of Veteran Affairs of any prospective construction contractors' project execution capabilities. The submission is limited to 10 pages which shall include the following information: 1) Offeror's name, address, point of contact, phone number, e-mail address, and Unique Entity ID. 2) Offeror's interest in bidding on the solicitation when it is issued. 3) Offeror's capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years - brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project - provide at least 1, but no more than 3 completed construction examples. 4) Offeror's CVE certification as a Veteran owned business. 5) Please provide Socio-economic status for NAICS code 541330. 6) Offeror's Joint Venture information if applicable - existing and potential. No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. There is no guarantee, expressed or implicit, that market research for this acquisition will result in a particular set-aside, or any other guarantee of award or acquisition strategy. Responses must be received by 2:00 PM Central on December 21, 2026 via e-mail to the Contracting Officer at Matthew.Finley@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: Project 589-27-108 Correct Electrical Deficiencies in Bldg. 26," IN THE SUBJECT LINE and cover sheet. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://beta.sam.gov/. The Contract Opportunities website is the only official site to obtain these documents. Contracting Office Address: Department of Veterans Affairs; Network 15 Contracting Office; 3450 S. 4th Street, Leavenworth, KS 66048 Point of Contact(s): Matt Finley, Contracting Officer, e-mail address: Matthew.Finley@va.gov | 64% | Market Research | 12/01/2026 |
DESCRIPTION Project: 589-27-108 Solicitation Number: 36C25527Q0057 RFP: 36C25527R0018 Title: Correct Electrical Deficiencies in Bldg. 26 Contracting Office: Network Contracting Office 15 Contracting Office Location: 3450 S 4th Street Traffic way, Leavenworth, Kansas Type of Notice: Sources Sought Posted Date:11/16/2026 Response Date: 12/1/2026 at 2:00 PM Central Time Set Aside: Service-Disabled Veteran Owned Small Business Classification Code: C222 -Architect and Engineering- Electrical Systems NAICS Code: 541330 Engineering Services Synopsis: Please note that this is NOT a request for SF330's or proposals, the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. The Department of Veterans Affairs Network Contracting Office (NCO) 15, is conducting a market survey for qualified: Service-Disabled Veteran Owned Small Businesses (SDVOSB), capable of providing the required services outlined below for the VA Medical Center located in Kansas City, Missouri. The applicable NAICS code is 541330 Engineering Services and the size standard is $25.5 Million. Responses to this notice must be submitted via e-mail to matthew.finley@va.gov and received no later than December 1, 2026 at 2:00 PM Central Time. No telephone inquiries will be accepted or returned. Additional information about this project will be issued on the Federal Business Opportunities website https://www.fbo.gov once available. Period of Performance for all design work is 150 calendar days including time for VA reviews. Prospective SDVOSB firms are reminded that in accordance with VA Acquisition Regulation (VAAR) 852.219-75, the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73. The prime architect shall provide written certification of this to the Contracting Officer with the response provided for this market research. GENERAL SCOPE OF DESIGN: The Architect/Engineer (A/E)) shall provide professional design services for a complete, coordinated, constructible, and independently usable project to correct electrical closets, secondary distribution, uninterruptible power, and emergency power deficiencies in Building 26 at the Kansas City VA Medical Center (KCVA), 4801 Linwood Blvd, Kansas City, MO 64128. A/E Part One Services (also known as the design phase) for this design project encompass site visits as needed, field investigations, and the conduct of studies and user interviews to prepare detailed drawings, specifications, and cost estimates. This effort covers all facets of work and disciplines/trades to facilitate and provide construction period services for a construction project. This effort covers all facets of work and disciplines/trades to facilitate a complete, coordinated, constructible, and independently usable project to correct electrical closets, secondary distribution, and emergency power deficiencies in Building 26 at the Kansas City VA Medical Center. The A/E services are required for preparation of Narrative, Studies, Phasing Design, Schematic Designs, Design Development, Construction Documents, and As Built Documents. The A/E shall coordinate all disciplines necessary to deliver a complete electrical infrastructure project. The A/E shall not rely solely on record drawings and shall verify existing conditions before using them as the basis of design. Ensuring all required permits and licenses from federal, state/provincial, or local authorities are obtained for the construction, installation, and operation of the equipment is also part of the A/E s responsibilities. The project design will comply with Infection Control and Interim Life Safety Measures. The A/E will provide design drawing, specification, and IGCE submissions at 35% (Schematic Design), 65% (Design Development), 95% (Construction Documents), and Final Bid Documents for all disciplines necessary to complete the project to the VA. END OF SCOPE OF WORK Interested firms must be registered in https://sam.gov with NAICS code 541330 and qualified as a Service-Disabled Veteran Owned small business under NAICS code 541330. Qualified service-disabled veteran owned small businesses are encouraged to respond and required to be registered in with the Small Business Administration (SBA) registry https://veterans.certify.sba.gov on or before the response date. If interested in this opportunity, please provide Capability Statement via email. The Capability Statement is designed to inform the Department of Veteran Affairs of any prospective construction contractors' project execution capabilities. The submission is limited to 10 pages which shall include the following information: 1) Offeror's name, address, point of contact, phone number, e-mail address, and Unique Entity ID. 2) Offeror's interest in bidding on the solicitation when it is issued. 3) Offeror's capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years - brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project - provide at least 1, but no more than 3 completed construction examples. 4) Offeror's CVE certification as a Veteran owned business. 5) Please provide Socio-economic status for NAICS code 541330. 6) Offeror's Joint Venture information if applicable - existing and potential. No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. There is no guarantee, expressed or implicit, that market research for this acquisition will result in a particular set-aside, or any other guarantee of award or acquisition strategy. Responses must be received by 2:00 PM Central on December 21, 2026 via e-mail to the Contracting Officer at Matthew.Finley@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: Project 589-27-108 Correct Electrical Deficiencies in Bldg. 26," IN THE SUBJECT LINE and cover sheet. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://beta.sam.gov/. The Contract Opportunities website is the only official site to obtain these documents. Contracting Office Address: Department of Veterans Affairs; Network 15 Contracting Office; 3450 S. 4th Street, Leavenworth, KS 66048 Point of Contact(s): Matt Finley, Contracting Officer, e-mail address: Matthew.Finley@va.gov | 64% | Market Research | 12/01/2026 |
PRESOLICITATION NOTICE Request for Architectural and Engineer (A/E) 330 submission Solicitation: 36C25526R0020 Upgrade Pharmacy & Pharmacy Compounding Suite HVAC MC, Project No. 589-26-472 CONTRACT INFORMATION Project 589-26-472, Upgrade Pharmacy & Pharmacy Compounding Suite HVAC This A-E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected based on demonstrated competence and qualifications for the required work. This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with FAR Subpart 36.6. This is not a Request for Proposal and an award will not be made with this announcement. This announcement is a request for SF 330 s from qualified Architectural and Engineer (A&E) contractors that meet the professional requirements. The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and are listed below. All factors are listed in descending order of importance. The completed SF 330 will be evaluated by the Kansas City VA Medical Center Evaluation Board in accordance with FAR 36.602-3 and the selection report shall serve as the final selection list, which will be provided directly to the Contracting Officer. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. The contract is anticipated to be awarded no later than April 30, 2026. Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted to David Sterrett via e-mail to: david.sterrett@va.gov. Personal visits to discuss this announcement will not be allowed. The NAICS Code for this procurement is 541330 Engineering Services and small business size standard of $25.5 M. Award of a Firm Fixed Price contract is anticipated. Anticipated time for completion of design is approximately 345 calendar days including time for VA reviews. The A/E firm shall also be required to perform construction services if award of a construction project contract is made. In accordance with FAR 36.204 and VAAR 836.204, the estimated magnitude of the construction project being designed is anticipated to be between $2,000,000.00, and $5,0000,000.00. DATABASE REGISTRATION INFORMATION: VERIFICATION OF STATUS OF APPARENTLY SUCCESSFUL OFFEROR. THIS ACQUISITION IS 100% SET-ASIDE FOR QUALIFIED SERVICE-DISABLED VETERAN OWNED SMALL BUSINESS AE FIRMS IN COMPLIANCE WITH VAAR 852.219-73 ONLY BUSINESSES VERIFIED AND LISTED AS CERTIFIED IN THE SBA CERTIFICATION DATABASE AT https://veterans.certify.sba.gov, SHALL BE CONSIDERED. SYSTEM FOR AWARD MANAGEMENT (SAM): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM) database at www.sam.gov and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM prior to submitting their qualifications package. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at www.sam.gov for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all of their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) A-E firms are required to respond if interested by submitting one (1) completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486) Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions must be in pdf, no larger than 20 Megabytes(MG), and emailed. Completed package shall be delivered electronically on or before Friday, December 5, 2025 at 2:00 pm Central Standard Time (CST) to the NCO 15 Contracting Office, Attn: David Sterrett, Contracting Officer, to the following email address: david.sterrett@va.gov Email subject line shall clearly identify Solicitation number: 36C25526R0020 and project name, Upgrade Pharmacy and Pharmacy Compounding Suite HVAC, Kansas City, Project No. 589-26-472 The SF330 submission must be a pdf document, must be below 20 megabytes (MG), and is not to exceed sixty (60) pages. Photographs or other graphics will be included in the 60-page count. Title pages and tables of contents, if applicable, are excluded from the page count limitation. Pages submitted in excess of the limitations specified in this notice will not be evaluated. The following is an example of how this standard will be enforced- if Company A submits their SF330 that is 100 pages, and the limit is 60 pages, only pages 1-60 will be submitted to the selection team for evaluation and pages 61-100 will be removed from Company A s SF330 document prior to being submitted for evaluation. Note: Signed Attachment 1, VAAR 852.219-75 VA Notice of Limitations on Subcontracting, must be included with your SF330 package or the SF330 will not be evaluated. PROJECT INFORMATION The mission of the Veterans Affairs Kansas City VA Medical Center is to provide the highest quality health care to our nation s veterans. In order to accomplish this mission Kansas City Facility Engineering Service (FES) intends to partner with an Architect/Engineer (A/E) or Engineer Firm for a design completion for Project 589-26-472, Upgrade Pharmacy and Pharmacy Compounding Suite HVAC. General Statement: The U.S. Department of Veterans Affairs (VA) requires Architectural and Engineering (A/E) services to produce stand-alone Construction Documents, Reports, and Specifications for Project: 589-26-472 Upgrade Pharmacy and Pharmacy Compounding located at the Kansas City VA Medical Center. This project will provide a dedicated AHU for the inpatient & outpatient pharmacy suite, repair floors ceiling grid, provide a dedicated AHU and exhaust for the Pharmacy compounding suite, and provide a temporary AHU during construction for continued pharmacy operations. Pharmacy and Pharmacy Compounding Suite are in Valor Building (Bldg. 26) on the second floor. It is approximately 5,500 SF. Drawings showing the primary area of work on the 2nd floor(HVAC and Pharmacy), first floor and in the basement (HVAC) are included. The design team is expected to be knowledgeable about current Pharmacy regulations that the VA is required to follow and the current officially approved USP797/USP800. In addition, VA current requirements from the Technical Information Library related to Pharmacy and HVAC design must be followed. The construction magnitude of this project is estimated to be between $2,000,000 and $5,000,000. EVALUATION FACTORS: Selection Criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as necessary. SF 330 submissions including any additional pages are not to exceed sixty (60) pages. Each page cannot exceed 8-1/2 x 11 in size. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required and SF 330 submissions including any additional pages are not to exceed sixty (60) pages. All pages above 60 pages will not be included in the evaluation. SF 330 must be submitted as a PDF to david.sterrett@va.gov and cannot exceed 20 MB in size. Refer to CONTRACT INFORMATION section points o. r. for additional submittal requirements and instructions. Qualifications (SF330) submitted by each firm for Upgrade Pharmacy & Pharmacy Compounding Suite HVAC, Project Number 589-26-472, will be reviewed and evaluated based on the following six (6) evaluation criteria listed below. The evaluation factors are listed in descending order of importance. The SF 330 selection criteria descriptions (1 through 6) are provided below: SF 330 Evaluation Factors (1 through 6) PROFESSIONAL QUALIFICATIONS Provide brief resumes of proposed team members who will specifically serve as the Project Manager(s), Designers of Record, and Quality Control Manager(s). In addition, provide resumes of other relevant team members or frequent subcontractors who will perform technical tasks under this contract including their record of working together. Designers and other team members include, but are not limited to: Architects, Engineers (Civil, Structural, Mechanical, Electrical, Plumbing, Fire Protection/Life Safety, Commissioning), Cost Estimators, Environmental Safety & Health, Industrial Hygiene, BIM/CAD Tech, and Third Party Fire Protection/Life Safety Design Review. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline in the state of Missouri or in a state which Missouri has recognized their license. Provide all required professional credentials for each Designer of Record that allows them to sign and seal drawings in the state of Missouri or in a state which Missouri has recognized their license. Each resume shall include a minimum of three (3) and a maximum of five (5) specific completed projects in the past five (5) years that best illustrate the individual team members experience relevant to this contract scope. Resume shall state the role the specific individual played in the project. SPECIALIZED EXPERIENCE & TECHNICAL COMPETENCE Specialized experience and technical competence in health care facilities (to include joint ventures), including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. This factor evaluates the amount of experience the AE firm has in designing similar types of work/facilities and evaluating their technical competence. The factor includes an emphasis, where appropriate, on the firm's experience in energy conservation, pollution prevention, waste reduction and the use of recovered materials. Provide a detailed narrative of a minimum of three (3) and up to five (5) maximum relevant projects that have completed design within the last 10 years AND completed construction within the last 5 years which best illustrate overall team experience relevant to this contract scope. List projects that demonstrate the teams experience with projects of similar size and scope to those to be performed under this contract; Specific design areas to be evaluated within this factor are: VA Hospital or Pharmacy experience incorporating relevant codes. Experience with designing to VA HVAC Design Manual standards and requirements for critical use areas or similar commercial standards. Familiarity with U.S. Pharmacopeia (USP) and its regulations for Pharmacy including but not limited to USP-797, USP-795 and USP-800 as individuals and also as a team working together. Firms that demonstrate this type of relevant past experience will be given a higher rating. Familiarity with and experience incorporating the requirements of current or recent VA guidance documents related to Sustainable Buildings including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. CAPACITY TO ACCOMPLISH WORK The general workload and staffing capacity of the design office that will be responsible for the majority of the design and the ability to accomplish the work in the required time. This factor evaluates ability of the AE firm, given their current projected workload and the availability of their key personnel, to accomplish the design project in the required time. It also requires that all firms submitting a 330 must certify that they can and will comply with VAAR 852.219-75 VA Notice of Limitations on Subcontracting. (See Attachment 1) The general workload and staffing capacity of the design office will be evaluated as follows: Indicate the firms' present workload and future availability of the project team (including sub-consultants) shown by month through, at a minimum, the next 18 months for the specified contract performance period. Describe experience in successfully delivering project submittals per performance schedule, maintaining the same key personnel from design NTP through final construction punch lists, providing timely construction period of services support, and successfully completing multiple projects with similar delivery dates. Describe how the team is going to meet the strict design deadlines for the proposed project of 345 days. In accordance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, you must certify that if awarded the contract your firm will comply with the limitations on subcontracting specified in this clause and in the resultant contract. You must complete, sign and submit Attachment 1- VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction document as part of your SF330 package which states the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73. If this certification is not completed and submitted with the SF 330, your package will not be evaluated, will be eliminated from the selection process, and cannot be awarded a contract. PAST PERFORMANCE NCO 15 will evaluate past performance on recent and relevant contracts with Government agencies (emphasis on VA work) and private industry in terms of construction cost estimating, cost control, quality of work, compliance with performance schedules and a record of significant claims against the firm due to improper or incomplete engineering services (references required). Project past performances that are older than 10 years will receive a lesser rating than those references for projects accomplished within the past 10 years. Past performance evaluations may also be conducted using information obtained from CPARS or PPIRS and any other sources deemed appropriate by the Contraction Officer. Other sources may include, but are not limited to, inquiries of owner representative(s), Federal Awardee Performance, and Integrity Information System (FAPIIS), Electronic Subcontract Reporting System (eSRS), and any other known sources not provided by the Offeror. Provide five (5) completed relevant project Final CPARS, past performance questionnaires, or similar documents as past performance documentation, or provide an explanation for not including 5 relevant Final CPARS or other equivalent documentation. List all projects with a design fee of greater than $400,000.00 designed in the firm s office in the past five (5) years. Include a brief summary of the scope, completion date, contract number, design award amount, construction cost estimate, construction completion date (if completed), customer name, point of contact, and location of work. ESTIMATING EFFECTIVENESS Provide information on the five (5) most recently awarded construction projects that were designed by this A/E team. Provide the project title, brief scope of work, A/E team s construction estimate total and actual construction award price. Provide projects performed in the Kansas City area that have provided your team with knowledge of the local area. Include brief project summary, design to limitation or construction value, and completion date for each project. If the difference is greater than 10% explain why the A/E believes the difference was greater than 10%. If the team does not have any recent projects, provide the same information on projects that the prime A/E for this team was the prime A/E for the past projects. Provide the names, titles and experience of the persons that will perform the design for each discipline; and then has oversight of the entire estimate. CLAIMS, TERMINATIONS, AND LITIGATION Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined. Provide information on any litigation involvement of the past five (5) years and the outcome. Attachment 1 Request for Architectural and Engineer (A/E) 330 submission Solicitation: 36C25526R0020 Upgrade Pharmacy & Pharmacy Compounding Suite HVAC Project No. 589-26-472 FAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction As prescribed in 819.6011(b), insert the following clause: VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) (a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.] (i) [X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating 18 U.S.C. 1001. Attachment 1 (Continued) Request for Architectural and Engineer (A/E) 330 submission Solicitation: 36C25526R0020 Upgrade Pharmacy & Pharmacy Compounding Suite HVAC Project No. 589-26-472 (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification: I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee: ________________________________________ Printed Title of Signee: _________________________________________ Signature: ___________________________________________________ Date: _____________________ Company Name and Address: ______________________________________ ________________________________________________________________ (End of clause) | 63% | Pre-Solicitation | 12/05/2025 |
Introduction Network Contracting Office 1 (NCO 1), supporting VA New England Healthcare System (VISN 1), is seeking potential sources for an upcoming requirement for Architect and Engineering Services as described in the attached statement of work. THIS NOTICE IS NOT A REQUEST FOR QUALIFICATION STATEMENTS (SF330). This notice is a market research tool and has not been set-aside for any small business category, but the notice is issued to determine appropriate set-aside categories. Responses to this notice, in conjunction with other Government market research resources, will be used by the contracting officer to determine the applicable socio-economic set-aside for the procurement. Failure to respond to this notice will not impact consideration of architect and engineer firms (or joint ventures) which otherwise meet set-aside requirements and submit responses to the follow-up public announcement. Once the appropriate set-aside is determined, a separate public announcement requesting qualification statements (SF330s) will be publicized on Contract Opportunities in accordance with 40 U.S. Code § 1101 and FAR 36.102. General Project Description and NAICS Synopsis of required services (See attachment for full statement of work): provide Architect/Engineer (AE) services to evaluate existing conditions, propose corrective measures, and design a construction project at the VA Maine Health Care System (Togus) in accordance with this scope of work. Scope will include Type A services only with design complete to 35%. AE Part I Investigative Services/Schematic Design/Other Related Services shall include site visits, field investigation, studies and user interviews to prepare drawings, and cost estimates for all facets of work and disciplines/trades to repair Chiller 3 to a condition where it will operate as designed. Design should also include fixes for the reported cooling and oil leaks. This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has a SBA size standard of $22.5 million in average revenue. Information Sought The Government requests a letter of interest (or similar document) with responses to the following: 1. State your firm name (as it appears in SAM.gov), Unique Entity Identifier (UEI) number, and socio-economic status of the firm (i.e. verified SDVOSB, WOSB, SB, large business). 2. Provide a brief narrative on the firm s experience, providing services similar to those described in the attached statement of work. 3. What would be the expected make-up of the firm s team in terms of socio-economic categories and estimated percentage of work to be completed by your firm and each subcontractor? If the procurement is set-aside for any category of small business, generally fifty percent of more of the work would need to be performed by the contractor or a similarly situated subcontractor in terms of percentage of cost. For instance, if set-aside for service-disabled veteran-owned small business (SDVOSB), 50% or more of the contract would need to be performed by verified SDVOSBs no other small business categories would count towards the percentage. If set-aside for small business, 50% of the contract would be required to be performed by small businesses which would include performance by a verified SDVOSB because they are also a small business. If the procurement is not set-aside and reaches certain dollar thresholds, the Government would negotiate an acceptable subcontracting plan to utilize small business concerns. 4. A brief statement of overall interest in the project and capability of performing the work in conjunction with ongoing projects. 5. Any additional capabilities statements or other documentation that you feel will assist the Government in performing market research and determining the appropriate set-aside. Submission Instructions Interested parties are requested to submit the requested information not later than November 20, 2026, to Diane C. Davis via email to diane.davis2@va.gov. Please include 36C24127R0009 Sources Sought Response in the title of the email. the response burden to this notice is expected to be light; lengthy responses are not expected but no maximum page count is assigned. Please keep responses below 7MB or send multiple emails appending to the email subject 1 of n as appropriate. Please contact Diane Davis at the email address above with any questions. Attachments | 63% | Market Research | 11/20/2026 |
Additional Details
Solicitation Number
36C24721R0012
Archive Date
Jan 28, 2021
Office Address