Notice ID: 608bd75c0b784b0d84c9fdf0a38e4232Award NoticeAwarded
C1DA--508 A-E IDIQ Contract - Atlanta VA Health Care System
Awarded on July 28, 2023. Full description on SAM.gov.
Awarded tounder 36C24723D0050 (source: SAM.gov award notice)• $0
Overview
- Posted
- July 28, 2023
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541330: Engineering Services
- Agency
- Department of Veterans Affairs
Notice details
- Place of performance
- Atlanta VA Health Care System 1670 Clairmont Rd, Decatur, GA, 30033
- Last updated
- Sep 9, 2025
- Award date
- Jul 28, 2023
- Award amount (SAM.gov award notice)
- $0
Identifiers
- Solicitation number
- 36C24723R0021
- Notice ID
- 608bd75c0b784b0d84c9fdf0a38e4232
- Award number (PIID)
- 36C24723D0050
Description
ARCHITECT-ENGINEERING (A/E) DESIGN SERVICES: The Atlanta VA Medical Center, Decatur, GA is seeking qualified Architectural and Engineering Firms for an Indefinite Delivery/Indefinite Quantity (IDIQ) contract for multi-discipline A-E engineering and design services for the Department of Veteran Affairs, Atlanta VA Health Care System (AVAHCS), located at 1670 Clairmont Road, Decatur, GA 30033, and other off-site locations within the AVAHCS. The selected A/E firm shall provide professional provide professional architectural/engineering services necessary for various multidiscipline projects, AVAHCS master planning; field survey; site and facility investigation; preparation of special technical studies; analyses of structural systems; feasibility and concept studies; material investigation and color studies; preparation of engineering studies and/or investigation and preparation of A-E documents, reports, and construction bid documents for projects with associated Structural, Civil, landscaping, Mechanical, Electrical, Historic Preservation, Environmental subsurface soil investigations and incidental work; Regulatory Compliance Reviews/Assessments; Preparation of design documents to include building and ground alteration, maintenance, repair, and minor construction; cost and schedule estimates; and Construction Period Services (CPS) or Construction Administration Services including monitoring and evaluating the construction progress for conformance to plans and specifications including review of required submittals by the contractor. (Please see Statement of Work, bullet point 4 listed below for detailed Types of Services to be provided by the A/E) To be selected, the A/E firm is required to have a registered Architect and Professional Engineer on staff. Any required engineering (Electrical, Mechanical, Civil, Structural, Fire Protection) as well as the Industrial Hygienist, Landscape Architecture or Interior Design services may be obtained on a consultant basis through a professional engineering firm. The period of performance for the resultant contract shall begin on the date of contract award for one (1) year, with the option to extend up to four (4) additional years for multi-discipline Architectural Design and usual and customary services; subject to a cumulative contract amount not to exceed $6,250,000.00. The guaranteed minimum amount for this IDIQ contract is $5,000.00 over the life of the contract. Individual task orders will not exceed $1,250,000.00. Multiple task orders may be awarded with similar completion schedules and overlapping delivery. Issuance of a task order shall not be affected until agreement has been reached by the Architect/Engineer (A/E) and the Contracting Officer. Work to be performed shall begin after issuance of the task order. Task orders may include, but are not limited to the following: 1) Planning Phase: to include but not limited to making site investigations, collecting data, performing analysis, making presentations, and conducting other factfinding studies as might be necessary to support the procurement of the design contracts for the design-bid-build contracts or for the design-build contracts of the project(s) or the serve as the design team. Task orders may include economic analysis and feasibility studies and developing scopes for programmed projects. Under this contract, the A-E may be required to furnish multi-discipline engineering services for reports, planning, and programming studies, investigations, site selection, design concepts, tentative design, working drawings and specifications, environmental compliance reviews and reports. Services may also include additional consultant services as necessary based on specific project scope. 2) Design Development: may include engineering calculations and analysis, complete design, samples, working drawings, specifications, and statements of probable cost. Drawings are to be completed on Auto-CAD® Release 2022, or later version, compatible with the existing CADD System and software. 3) Construction Documents: to provide complete detailed construction documents for final review that are of such quality and completeness that they can be competitively bid by contractors. 4) Bid Documents: to provide completed detailed, signed drawings, specifications and documents complete and ready for issuance to prospective contractors. A/E firms will prepare drawings and specifications in sufficient detail such that qualified outside General Contracting companies can prepare accurate and timely proposals for the desired work. A/E firms are responsible for ensuring that the specifications and drawings supplied fully represent all of the work described in the Request for Proposal (RFP). The Medical Center must remain operational throughout the construction period and a detailed sequence of work will be provided by the A/E to minimize impact of the construction. 5) Construction Period Services: may include commissioning services, consultation and visits, design work as related to inquiries and modifications, hazardous material abatement plans, preparation of cost estimates including contractor bid analysis and recommendations, and participation in any pre-bid and preconstruction conferences. All Task Orders shall remain open until after the competition of the construction contract to allow for the full use of construction period services. (Please refer to Statement of Work, bullet point 5, for more detailed information regarding Task Order Procedures) This is a 100% set-aside for SDVOSB firms only. The firms will need to be Center for Veterans Enterprise (CVE) verified and visible in VIP (VAAR 8041102) when SF330 s are submitted. Failure of a prospective SDVOSB to be verified by the CVE at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to contract award. Prospective Contractors are cautioned that proposal submitted in response to this solicitation must meet the criteria identified by 38CFR, Part 74. The SDVOSB concern agrees that in the performance of the contract, the concern will comply with the limitation on subcontracting requirements in accordance with VAAR Clause 852-219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside. This requirement is being procured in accordance with The Brooks Act of 1972, Federal Acquisition Regulation 36.6 (FAR) and VA Acquisition Regulation 836.6 (VAAR). A Firm Fixed Price A/E Design Service contract is contemplated for each of the task orders. The North American Industry Classification System (NAICS) Code is 541330, Engineering Services, and the small business size standards is $25.5 million respectively. Interested parties shall ensure current state licensing, shall have current registration in the Central Contractor Registration (CCR) database at http://ccr.gov, verified as a SDVOSB in Vet Biz information pages (VIP) at hrrp://vip.vetbiz.gov and reporting to VETS 100 program at https://vets100.dol.gov.vets100login.htm. SDVOSB verification is mandatory to be considered for award. Firms must be registered in SAM (System for Award Management) database, information on registration requirements can be obtained on the Internet at (http://sam.gov) and submit their complete Annual Representation s and Certifications (ORCA) via online at htpp://orca.bpn.gov. Any firm not CVE verified upon submission of their SF330 s will not be evaluated and not considered for award. Please submit a copy of the CVE verification letter with your SF330 package. A/E firms are advised that in accordance with VAAR 836.606-73 the total design services cost of the architect or engineer services contracted for must not exceed six percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR Clause 52.236-22 - Design Within Funding Limitation, will be applicable to any task order or procurement action under this A/E IDIQ. Firms will be evaluated by the A/E Evaluation Board, scored and ranked according to score. The most qualified firms will be invited to interview with the selection board. The number of firms selected to interview will be dependent on the number of firms that submit SF-330s. A minimum of three firms will interview with the selection board and will again be numerically scored and ranked. The firm with the highest score will be selected to negotiate an A/E IDIQ contract in the order of the rankings. Responses should be submitted on an SF330. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP type in SF330 in the "Find a Form" block and click on search. This project includes a requirement for site visits and coordination on design reviews, A/E firms will be required to attend meetings in person on site at the Atlanta VA Medical Center in Decatur, GA. Due to this requirement, the area for consideration for this acquisition is restricted to eligible A/E firms, to include subcontractors, team members, and partners with an operating office located within the local geographic region of the Atlanta VAMC, Decatur, GA. The local geographic location of consideration for this project is: The Eligible prime contractor firms must have a main and/or branch office geographically located within a 600-mile radius of the Atlanta VA Medical Center located at 1670 Clairmont Road, Decatur, GA 30033. Interested firms must include the location of an operating office within the radius in their SF330 package. Failure to comply with this requirement may jeopardize the possibility of receiving an award for the contract due to noncompliance with the terms of the solicitation. Prospective firms shall address all selection criteria factors within their submitted SF330 packages. Submission of information incorporated by reference is not allowed. Interested firms shall submit SF 330 via electronic transmission to the Contracting Officer by the designated date/time specified. No SF 330 hard copies will be accepted. Failure to comply with this requirement may jeopardize the possibility of receiving an award for the contract due to noncompliance with the terms of the solicitation. Submitted SF330s will include the following elements: 1. Standard Form 330 (Rev. 3/2013) Architect-Engineer Qualifications 2. SF330, Section H: Additional Information Firms submitted SF330s will be evaluated by an A/E evaluation board, scored, and ranked according to score. The following evaluation criteria will be used to evaluate SF 330 technical proposals: a. Professional qualifications necessary for satisfactory performance of required service and their record of working together as a team (in-house and/or consultants(s)). Note: The firm and A/E on staff representing the project or signing drawings in each discipline must be registered/licensed to practice in the United States. Provide your information on the SF 330 clearly marked by providing a current architect and/or engineering License numbers AND proof of Licensure. The VA will confirm the individuals are current and in good standing with the respective state license board. b. Specialized experience and technical competence in the type of work required, including but not limited to: Architecture, Civil, Electrical, Plumbing, Mechanical, Fire Protection, Cost Estimation, Project Management and where appropriate, experience in energy conservation, pollution prevention, waste reduction, and demonstrated success in prescribing the use of recovered materials and using waste reduction and energy efficiency in facility design. (Include Government and private Experience on similar projects)). Provide examples of experience and demonstrate the ability to provide professional consulting and design services relevant to hospitals and healthcare organizations; familiarity with applicable codes and ability to incorporate in design documents the requirements of the Joint commission, OSHA, NFPA, IBC, and other such regulatory organizations, and commissioning certification and experience. This includes but is not limited to; safety related requirements as the implementation of interim life safety measures (ILSMs) and infection control risk assessments (ICRAs). c. Capacity of the A/E firm to perform work required within required time frames and budget. Volume of previously awarded contracts and government experience should be demonstrated. d. Past performance on contracts with Government agencies and private industry. Highlight past performance in a hospital environment, including, but not limited to design development, construction cost estimating, cost control, code review and implementation, quality of work, and compliance with performance schedules, etc. e. Location in general geographical area and knowledge of the locality of the project and that your proximity to the general geographical area enables you to respond to emergency calls in person within 24 hours if required. (SF 330 submittal should show your knowledge of the locality of the project.). Eligible prime contractor firms must have a main and/or branch office geographically located within the 600-mile radius. f. Construction Period Services: Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates g. Reputation and standing of the firm and its principal officials with respect to professional performance, national recognition, general management, and cooperation. Record of significant claims against the firm because of improper or incomplete architectural and engineering services (Errors and Omissions). h. The relative utility of alternative methods and feasible ways to prescribe the use of recovered materials and achieve waste reduction and energy-efficiency in facility design. i. Acceptability under other appropriate evaluation criteria, i.e. SF330, Section H: a. Management Plan i. Management Process ii. QA/QC iii. Cost Control iv. Schedule Control b. Proposed Design Approach Each respondent must be able to demonstrate the ability to comply with FAR Clause 52.219-14, Limitations on Subcontracting and all Joint Ventures must be CVE verified, submit agreements that comply with 13 CFR 125.15 prior to contract award. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. THIS IS A PRE-SOLICITATION NOTICE FOR ARCHITECT/ENGINEERING (A/E) DESIGN SERVICES; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330. ONLY THE A/E FIRMS RESPONDING TO THIS ANNOUNCEMENT BY SUBMITTING AN SF330 PACKAGE ON TIME WILL BE CONSIDERED FOR INITIAL EVALUATION. Offerors must submit SF 330s via email to the Contracting Officer, Joseph.Osborn@va.gov. No hard copy SF330s will be accepted. Contracting Officer Contact Information: Email: Joseph.Osborn@va.gov Phone: (205) 561-8857 Firms shall submit SF 330s no later than 10:00 AM CST, Friday, January 27, 2023. All questions regarding this announcement must be e-mailed to the contracting office at Joseph.Osborn@va.gov.
Award Overview
Award Number
36C24723D0050
Award Amount (SAM.gov award notice)
$0
Award Date
Jul 28, 2023
Awardee
Awardee UEI
G9KCR27F65D7
Original Solicitation
Notice ID: 608bd75c0b784b0d84c9fdf0a38e4232
Posted Date: Jul 28, 2023
Original Response Deadline: Not specified
Task Orders Under This IDV
Top 10 by total obligated
- $1.2MSigned May 20, 2026
- $1.2MSigned Sep 29, 2026
- $1.2MSigned Oct 27, 2026
- $1.2MSigned Sep 8, 2025
- $961.4KSigned Feb 4, 2026
- $961.4KSigned Sep 14, 2026
- $961.4KSigned Jun 10, 2026
- $961.4KSigned Nov 5, 2025
- $730.0KSigned Sep 25, 2025
- $730.0KSigned May 23, 2025
More From This Vendor
Top 5 most recent
- $217.2KSigned Oct 28, 2026
- $1.2MSigned Oct 27, 2026
- $227.7KSigned Oct 13, 2026
- $204.9KSigned Oct 9, 2026
- $717.9KSigned Oct 1, 2026
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24723R0021- Pre-Solicitation
- Awarded
This opportunity has been awarded.
- Pre-SolicitationDec 21, 2022
C1DA--508 A-E IDIQ Contract - Atlanta VA Health Care System (VA-23-00022949)
- AwardedCurrentJul 28, 2023
C1DA--508 A-E IDIQ Contract - Atlanta VA Health Care System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
DESCRIPTION: This is a Pre-Solicitation Notice for project number 596A4-27-101 that requires Architect/Engineering (A/E) Design Services to Upgrade Fire Alarm System at the Lexington VA Healthcare System, Troy Bowling Campus. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSALS. ONLY THE A/E FIRMS RESPONDING TO THIS ANNOUNCEMENT BY SUBMITTING AN SF330 PACKAGE ON TIME WILL BE CONSIDERED FOR INITIAL EVALUATION. FOLLOWING INITIAL EVALUATION OF THE A/E FIRMS AND THEIR SF330S, A SOLICITATION FOR A PRICE PROPOSAL WILL BE SENT TO THE HIGHEST TECHNICALLY RATED A/E FIRM TO PROVIDE THE TYPE OF SERVICE(S) REQUIRED. The A/E Services contract that is anticipated to be awarded will be procured in accordance with the Brooks Act (Public Law 92- 582), Federal Acquisition Regulation Part 36.6 and VA Acquisition Regulation 836.6. In accordance with FAR 36.209 Construction Contracts With Architect-Engineer Firms , no contract for the construction of a project shall be awarded to the firm that designed the project or its subsidiaries or affiliates, except with the approval of the head of the agency or authorized representative. A/E DESIGN SERVICES SCOPE SYNOPSIS: The A/E will be required to perform comprehensive field investigations to base their design documents off of, this includes, above ceiling surveys that the VA will assist with access to all required spaces. Project will replace existing fire alarm system at the Troy Bowling Campus to include Building 1, Building 1A and Building 4. Replacement includes hospital space, parking garage as well as crawl space as required per code. Size of existing facility is 537,542 square feet. Existing fire alarm system is required to remain in service until new system is active and ready to be utilized. Phasing of cutover from existing to new system to be determined by A/E. Project will correct FCA Deficiencies 338139, 45058, 49003, 49909, 49035, 49963 and 49935. New fire alarm system will be required to interact with multiple systems throughout the hospital to include, but not limited to: Door magnets, elevators, HVAC systems, kitchen hood systems, sprinkler system, specialty fire suppression systems, door locking systems, smoke dampers, duct detectors and other systems. The estimated magnitude of construction for this A/E requirement is between $10,000,000 and $20,000,000. END OF DESIGN SCOPE SYNOPSIS Digital copies of the as-builts are limited. The consultant will be expected to fully investigate and confirm the validity of hard copy as-builts and other drawings. This will include independent investigation of the VAMC s flat files by the consultant to determine and procure the information required for the complete design. All offerors are advised that in accordance with VAAR 836.606-73 the total cost of the architect or engineer services contracted for must not exceed 6 percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR Clause 52.236-2 (c) - Design Within Funding Limitation, will be applicable to this procurement action. Design limitation costs will be provided to the most highly rated AE firm selected to complete the design. Interested firms should submit their current SF-330 to matthew.whisman@va.gov. The SF-330s are due by December 3, 2026, at 2:00 PM (EST). Security Issues, Late Bids, Unreadable Offers Late submission of offers are outlined at FAR Parts 52.212-1(f), 52.214-7, and 52.215-1(c) (3). Particular attention is warranted to the portion of the provision that relates to the timing of submission. Please see FAR 15.207(c) for a description of the steps the Government shall take with regard to unreadable offers. To avoid rejection of an offer, vendors must make every effort to ensure their electronic submission is virus-free. Submissions or portions thereof submitted and which the automatic system detects the presence of a virus or which are otherwise unreadable will be treated as unreadable pursuant to FAR Parts 14.406 and FAR 15.207(c ). The virus scanning software used by our e-mail systems cannot always distinguish a macro from a virus. Therefore, sending a macro embedded in an e-mail message or an e-mail attachment may cause the e-mail offer to be quarantined. You may send both the spreadsheet and the spreadsheet saved in PDF format to ensure that your proposal is readable. Password protecting your offer is not permitted. The Contracting Officer will file the offer electronically which will allow access only by designated individuals. Important Notice: Apparent successful offerors must be registered in the U.S. Small Business Administration (SBA) site at the time of submission of proposal. Failure to be both VERIFIED by the SBA and VISIBLE at the time of proposal submission, time of interview, and at time of award will result in the offeror s proposal being deemed non-responsive. All offerors are urged to contact the SBA DSBS (https://dsbs.sba.gov/search/dsp_dsbs.cfm) and submit the required documents to obtain verification of their SDVOSB status if they have not already done so. Response Time: The successful A-E shall abide by a four (4) hour response time for Lexington VA Healthcare System, during the design phase and the construction period services (CPS) phase, as appropriate. The VA has no preference on the method utilized by contractors on achieving the four (4) hour response time. The response time will be determined from the moment the request to the A-E to be on site is submitted. The individual or individuals responding can be either the prime contractor or a subcontractor that s part of the design team. The selection process will follow the guidance referenced within 36.602-3 and FAR 36.602-4. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Firms will be selected based on demonstrated competence and qualifications for the required work. Contract Award Procedure: Before a small business is proposed as a potential contractor, they must be certified by SBA DSBS and registered in the System For Award Management (SAM) database. Register via the SAM internet site at https://sam.gov/content/home Failure of a proposed SDVOSB to be certified by the SBA DSBS at the time the SF 330 is submitted shall result in elimination from consideration as a proposed contractor. The proposed services will be obtained by a Negotiated Firm-Fixed Price Contract. The review/design of architectural, structural, mechanical, electrical, civil, or other engineering features of the work shall be accomplished by architects or engineers registered in a State or possession of the United States, or in Puerto Rico or in the District of Columbia. The project drawings/design shall be in compliance with applicable standards and codes described in VA Program Guides and design materials. Master Construction Specifications Index, VA Construction Standards Index, VA Standards Index, and Criteria are available in the Technical Information Library (TIL) on VA Website address: http://www.cfm.va.gov/til/. The awarded A/E firm will prepare drawings and specifications in sufficient detail such that qualified outside General Contracting companies can prepare accurate and timely proposals for the desired work. The awarded A/E firm is responsible for ensuring that the specifications and drawings supplied fully represent all of the work described in the Request for Proposal (RFP). The Medical Center must remain operational throughout the construction period and a detailed sequence of work will be provided by the A/E to minimize impact of the construction. The NAICS code for this project is 541330 with a small business size of $25.5 million. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, type in SF-330 in the Find a Form block and click on search. SELECTION CRITERIA: Selection criteria for this acquisition are listed below; Professional qualifications necessary for satisfactory performance of required services; Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; Capacity to accomplish the work in the required time; Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness; Record of significant claims against the firm because of improper or incomplete architectural and engineering services; and Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. THIS IS NOT A REQUEST FOR PROPOSAL. This is a request for SF 330's Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. No material will be issued and no solicitation package or bidder/plan holder list will be issued. A solicitation will only be issued to the most highly qualified vendor. Electronic Submission Requirements: Unless paper offers are specifically authorized in an individual solicitation, all responses to solicitations must be submitted electronically as described below. Responses submitted in a paper form are unacceptable and will be returned. Failure to comply with this requirement may jeopardize the possibility of receiving an award for the contract due to noncompliance with the terms of the solicitation. You must submit your electronic offer, and any supplemental information (such as spreadsheets, backup data, technical information), using any of the electronic formats and media described below. Additionally, contractors are notified of the award via an electronic Notice of Award e-mail. The award document will be attached to the Notice of Award e-mail. Acceptable Electronic Formats (Software) for Submission of Offers Files readable using the current Microsoft* Office version Products: Word, Excel, and PowerPoint. Please see security note below for caution regarding use of macros. When submitting construction drawings contractors are required to submit one set in AutoCAD and one set in Adobe PDF. (purpose: contracting can open the PDF version and engineering can open AutoCAD files); Files in Adobe* PDF (Portable Document Format) Files: When scanning documents scanner resolution should be set to 200 dots per inch, or greater; Other electronic format.  If you wish to submit an offer using another format other than described in these instructions, e-mail the Contracting Officer who issued the solicitation.  Please submit your request at least ten (10) calendar days before the scheduled closing date of the solicitation.  Request a decision as to the format acceptability and make sure you receive approval of the alternate format before using it to send your offer; and Submitted SF330 s are not to exceed a total of fifty (50) pages INCLUDING cover page and any other submitted documents. Please note that we can no longer accept .zip files due to increasing security concerns. E-mail Submission Procedures: For simplicity in this guidance, all submissions in response to a solicitation will be referred to as offers. Subject Line: Include the solicitation number, name of company, and closing date of solicitation; Size: Maximum size of the e-mail message shall not exceed five (5) megabytes. Only one email is permitted unless otherwise stated in this paragraph or in writing by a Contracting Officer. Submission is to be no more than a total of fifty (50) pages; and The offer will be date and time stamped by the Microsoft Email system and will be the official record of receipt for the submission. Point of Contact : Matthew Whisman E-mail questions to: matthew.whisman@va.gov VA NOTICE OF TOTAL SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS SET-ASIDE (DEC 2009) (a) Definition. For the Department of Veterans Affairs, Service-disabled veteran-owned small business concern : (1) Means a small business concern: (i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans (or eligible surviving spouses); (ii) The management and daily business operations of which are controlled by one or more service-disabled veterans (or eligible surviving spouses) or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran; (iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document; and (iv) The business has been verified for ownership and control and is so listed in the Vendor Information Pages database, (https://dsbs.sba.gov/search/dsp_dsbs.cfm). (2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16). (b) General. (1) Offers are solicited only from service-disabled veteran-owned small business concerns. Offers received from concerns that are not service-disabled veteran-owned small business concerns shall not be considered. (2) Any award resulting from this solicitation shall be made to a service-disabled veteran-owned small business concern. (c) Agreement. A service-disabled veteran owned small business concern agrees that in the performance of the contract, in the case of a contract for: (1) Services (except construction), at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other eligible service-disabled veteran-owned small business concerns; (2) Supplies (other than acquisition from a non-manufacturer of the supplies), at least 50 percent of the cost of manufacturing, excluding the cost of materials, will be performed by the concern or other eligible service-disabled veteran-owned small business concerns; (3) General construction, at least 15 percent of the cost of the contract performance incurred for personnel will be spent on the concern s employees or the employees of other eligible service-disabled veteran-owned small business concerns; or (4) Construction by special trade contractors, at least 25 percent of the cost of the contract performance incurred for personnel will be spent on the concern s employees or the employees of other eligible service-disabled veteran-owned small business concerns. (d) A joint venture may be considered a service-disabled veteran owned small business concern if (1) At least one member of the joint venture is a service-disabled veteran-owned small business concern, and makes the following representations: That it is a service-disabled veteran-owned small business concern, and that it is a small business concern under the North American Industry Classification Systems (NAICS) code assigned to the procurement; (2) Each other concern is small under the size standard corresponding to the NAICS code assigned to the procurement; and (3) The joint venture meets the requirements of paragraph 7 of the explanation of Affiliates in 19.101 of the Federal Acquisition Regulation. (4) The joint venture meets the requirements of 13 CFR 125.15(b). (e) Any service-disabled veteran-owned small business concern (non-manufacturer) must meet the requirements in 19.102(f) of the Federal Acquisition Regulation to receive a benefit under this program. END OF PRE-SOLICITATION NOTICE | 86% | Pre-Solicitation | 12/03/2026 |
Solicitation 36C24426R0153 | 85% | Special Notice | 09/18/2026 |
This Special Notice is for synopsis 36C26324R0045 Request for Qualifications To alert the public that this MATOC IDIQ has been reviewed by the administration and has been determined to be redundant and is no longer a justified need. Therefore, this synopsis has been cancelled indefinitely. | 78% | Special Notice | 11/20/2026 |
Description: The Department of Veterans Affairs (VA) seeks to retain an independent third-party Commissioning Agent to perform comprehensive commissioning services for the subject project. This project will replace and repair roofing and lighting protection at the Cincinnati VA Medical Center (Building Numbers: 1, 2, 3, 8, 13, 14, 15, 16 and trailers) including main and Fort Thomas Campuses (Building Numbers: 64, 117 and trailers), in accordance with the general items as written (231000 sq-ft). Selection Criteria: (1) Professional qualifications necessary for satisfactory performance of required services; (2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; (3) Capacity to accomplish the work in the required time; (4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; (5) Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; (6) The extent to which potential contractors identify and commit to the use of service-disabled veteran owned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors. SUBMITTAL INSTRUCTIONS All interested and capable contractors must submit an electronic copy of their SF 330s, via email, by the closing time/date of this announcement. Note the following: No hard/physical copies will be accepted. Limit SF 330 packages to 50 pages. Only the first 50 pages will be evaluated. Submit all documentation as one single file. The total size of the electronic submission (email and all attachments) must not exceed 15MB; larger emails may get rejected by the network server and will be considered non-responsive. Cited relevant projects must be within the last five (5) years. Submit packages via email to the contract specialist by the deadline:Â ronald.heidemann@va.gov Subject line must include the notice number: 36C25027R0011 Please include your firm s POC and UEI in the email body. ***End of Presolicitation Notice** | 76% | Pre-Solicitation | 11/05/2026 |
Provide complete design services, including all necessary schematics, design development, surveys, cost estimates, construction drawings and specifications, and construction period services (CPS) for solicitation to replace and repair roofing and lighting protection at the Cincinnati VA Medical Center, 3200 Vine Street, Cincinnati, OH 45220 (Building Numbers: 1, 2, 3, 8, 13, 14, 15, 16 and trailers) and the Fort Thomas Campus, 1000 S. Ft. Thomas Ave, Ft. Thomas, KY 41075 (Building Numbers: 64, 117 and trailers), in accordance with the general items as written (231000 sq-ft - estimated). This project will replace and repair the roofing and lightning protection. Replacement of outdated roofing and lighting protection will reduce overall emergency maintenance, increase facility operation, and provide proper protection. SELECTION CRITERIA The Government will evaluate each potential contractor under the terms of its: A. Professional qualifications necessary for satisfactory performance of required services; B. Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; C. Capacity to accomplish the work in the required time; D. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; E. Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; F. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services, and; G. The extent to which potential contractors identify and commit to the use of service-disabled veteran-owned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors. SUBMITTAL INSTRUCTIONS All interested and capable contractors must submit an electronic copy of their SF 330s, via email, by the closing time/date of this announcement. Note the following: No hard/physical copies will be accepted. Limit SF 330 packages to 50 pages. Only the first 50 pages will be evaluated. Submit all documentation as one single file. The total size of the electronic submission (email and all attachments) must not exceed 15MB; larger emails may get rejected by the network server and will be considered non-responsive. Cited relevant projects must be within the last five (5) years. Submit packages via email to the contract specialist by the deadline:Â ronald.heidemann@va.gov Subject line must include the notice number: 36C25027R0009 Please include your firm s POC and UEI in the email body. ***End of Presolicitation Notice** | 76% | Pre-Solicitation | 11/04/2026 |
Additional Details
Solicitation Number
36C24723R0021
Archive Date
Aug 11, 2023
Office Address
AUGUSTA, GA, 30904